    Room Air Conditioner Ser vice and P ar ts Man ual CP10 - CP12 Svc Parts 2010 (0 5/ 10 ) C P 1 0 F10 C P 12F10 0 F Power Mode Timer 0n/ 0 ff Fan Speed Temp Cool Money Saver ® Fa n Only Dry hr Auto Swing 1 15V olts ...

  • Friedrich CP12F10 - page 2

    2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......................................................................................................... ...

  • Friedrich CP12F10 - page 3

    Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. Incorrect ope r ation due to igno r ing inst r uctions will cause ha r m or damag e . The se r iousness is classified b y the f ollowing indications.  Meanings of symbols ...

  • Friedrich CP12F10 - page 4

    4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause elect r ic sho c k or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire. Do not damage or use an unspecified power cor d. • It will cause electric shock or fire. Do n ...

  • Friedrich CP12F10 - page 5

    Ser vice Manual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main body of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine. Do not clean the air conditioner with water . • Water ma y ...

  • Friedrich CP12F10 - page 6

    6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner . This symbol indicates special notes. NOTICE Symbols Used in this Manual 353(13 7 / 8 ") 470(18 1 / 2 ") 525(20 11 / 16 ") ...

  • Friedrich CP12F10 - page 7

    Se r vice Ma n ual Specfications Pr oduct Specifications Ser 7 Pr oduct Specifications Ser Pr oduct Specifications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (BTU/W . h) INDOOR ( F) OUTDOOR ( F) REFRIGERANT (R410) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN ...

  • Friedrich CP12F10 - page 8

    0 F Power Mode Timer 0 n / 0 f f Fan Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 2 3 4 5 7 A i r P u r i f i e r P o w e r T e m p Mo d e T i m e r A S wi n g F a n S pe e d 1 2 4 3 5 Auto Swing 6 6 6. A UT O SWING This button can automatically control the air flow direction. 7 Se r vice Ma n ual 8 ...

  • Friedrich CP12F10 - page 9

    Disassembly Disassem b l y Mechanical Parts Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. F R ONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. 5. Re-install the component ...

  • Friedrich CP12F10 - page 10

    10 Room Air Conditioner Disassembly Air Handling P ar ts 1. AIR GUIDE AND BL O WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator. 7. Move the evaporator forward and pulling it upward slightly. (See F ...

  • Friedrich CP12F10 - page 11

    Se r vice Ma n ual 1 1 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from the mount motor. (See Figure 7 ) 8. Remove the motor. 9. Re-install ...

  • Friedrich CP12F10 - page 12

     MODEL : TOUCH & REMOTE CONTROL TYPE MODEL Disassembly 1 2 Room Air Conditioner 1. Remove the control box. 2. Remove the screw which fasten control panel from control box. 3. Remove the screw which located in the front. 4. Open the bottom side of control box. 5. Remove the screw and the clamp which fastens the capacitor. 6. Disconnect all th ...

  • Friedrich CP12F10 - page 13

    13 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after se ...

  • Friedrich CP12F10 - page 14

    Se r vice Ma n ual 14 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SID ...

  • Friedrich CP12F10 - page 15

    Se r vice Ma n ual 15 Schematic Diagr am Cir cuit Diagram  MODEL : TOUCH & REMOTE CONTROL TYPE MODEL LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.W.B ASSEMBLY MAIN P.W.B ASSEMBLY THERMISTOR CAPACITOR OWERLOAD PROTECTOR (SMPS) 250V/T2A (250V/T3.15A) MEZ62420717 W ...

  • Friedrich CP12F10 - page 16

    16 Room Air Conditioner Electr onic Control De vice Schematic Diagram ...

  • Friedrich CP12F10 - page 17

    17 Room Air Conditioner T roubleshooting Guide T r oubleshooting Guide Piping System Figure 15 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle. MOTOR COMPRESSOR OIL (LIQUID R ...

  • Friedrich CP12F10 - page 18

    Se r vice Ma n ual 18 T roubleshooting Guide T r oubleshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling ...

  • Friedrich CP12F10 - page 19

    19 Room Air Conditioner T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start. Defect of compressor capacitor. Replacement of compressor (Motor damaged). Irr ...

  • Friedrich CP12F10 - page 20

    Se r vice Ma n ual 20 T roubleshooting Guide ■ MODEL : BG8000ER, WG8000RY4, WG1000RY4 ELECTRIC P AR TS TROUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC ...

  • Friedrich CP12F10 - page 21

    21 Room Air Conditioner T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.W.B Ass'y. Is the voltage N0.7 of IC01M DC 5V? • Check the RY-COMP. • Chec ...

  • Friedrich CP12F10 - page 22

    Se r vice Ma n ual 22 T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern. • Connect connector to CN-DISP1 exactly. NO NO NO YES YES YES P o ...

  • Friedrich CP12F10 - page 23

    23 Room Air Conditioner T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V Y D E M E R E S U A C T N I A L P M O C Fan motor will not run. No power Check voltage at outlet. Correct if none. Wire disconnected or Connect wire. Refer to wiring diagram for connection loose terminal ide ...

  • Friedrich CP12F10 - page 24

    Se r vice Ma n ual 24 T roubleshooting Guide Y D E M E R E S U A C T N I A L P M O C , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I n a F . e s i o n r o t o m n a F replace it. , g n i s s i m y l l a i t r a p r o , e c n a l a b f o t u o , d e k c a r c f I r e w o l B replace it. Loose set screw Tighten it. ...

  • Friedrich CP12F10 - page 25

    25 Room Air Conditioner COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) Co ...

  • Friedrich CP12F10 - page 26

    Se r vice Ma n ual 26 Exploded View Exploded Vi e w 249950 238310 237200 359011 135500 W0CZZ 567480 264110 268711-1 268711-2 146812 731273 267110 749740 148000 34681 1 W48602 352380 349600 149980 359012 W48602 349001 349480 152302 135303 147581 130410 135312 550140 567502 130910 147582 ...

  • Friedrich CP12F10 - page 27

    27 Room Air Conditioner Rep l a c em e n t P a r t s l i s t LocNo DESCRIPT ION CP10F10 CP12F10 130410 Base Assem bly ,Single 67305518 67305518 130910 Cabinet Assembly,Si ngle 67303716 67303716 135303 Grille,Inlet 67306112 67306112 135312 Grille Assem bly ,Front(Indoor) 67306019 67306019 135500 Cover 67304701 67304701 146812 Motor,AC 67300902 67300 ...

  • Friedrich CP12F10 - page 28

    Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts... CP10 - CP12 Svc Parts 2010 (0 5/ 10 ) ...

メーカー Friedrich カテゴリー Air Conditioner

Friedrich CP12F10のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CP12F10の取扱説明書
- Friedrichの製品カード
- パンフレット
- またはFriedrich CP12F10の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Friedrich CP12F10の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Friedrich CP12F10の取り付け説明書、サービスマニュアル、簡易説明書、またはFriedrich CP12F10のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Friedrich CP12F10の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Friedrich CP12F10デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFriedrich CP12F10を使用するのを助ける技術的文書のことです。説明書は通常、全てのFriedrich CP12F10ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Friedrichの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Friedrich CP12F10の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFriedrich CP12F10の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Friedrich CP12F10に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Friedrich CP12F10デバイスの基本機能を使うにあたってのヒント。 Friedrich CP12F10のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Friedrich CP12F10に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFriedrich CP12F10のメーカー/サービスへの連絡先に関する情報。

Friedrich CP12F10についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFriedrich CP12F10の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFriedrich CP12F10で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)