Graco 3A0410Dの取扱説明書

24ページ 3.4 mb
ダウンロード

ページに移動 of 24

Summary
  • Graco 3A0410D - page 1

    Operation Husky ® 3300 Air -Operated Diaphra gm Pump 3A0410D EN Heavy-duty 3-inc h pump with large flo w paths for fluid transf er applications, inc luding high-viscosity materials. For professional use onl y . See page 4 for model inf ormation, including appr ov als. 125 psi (0.86 MP a, 8.6 bar) Maximu m Wo rking Pressure, Alumin um or Stainless ...

  • Graco 3A0410D - page 2

    Related Manua ls 2 3A0410D Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T o Order a New Pump . . . . . . . . . . . . . . . . . . . . . . . 3 T o Order Replacement Parts . . . . . . . . . . . . . . . . . 3 Distributor Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Configuration Number Matrix . . . ...

  • Graco 3A0410D - page 3

    To Find Your Nearest Distributor 3A0410D 3 T o Find Y our Nearest Distrib utor 1. Visit www .graco .com . 2. Click on Where to Buy and use the Distributor Locator . T o Specify the Configuration of a Ne w Pump Please call y our dist ribut or . OR 1. Use the Online Husky Sel ector T ool at wwwd.graco .com/training/husky/inde x .html. 2. If the link ...

  • Graco 3A0410D - page 4

    Configuration Numb er Matrix 4 3A0410D Configuration Number Matrix Chec k the identification plate (ID) f or the 20-digit Configuration Number of y our pump . Use the follo wing matrix to define the components of y our pump . Sample Configuration Number: 3300A-A01AA1 TP A CTPBN * Models with Buna-N, FKM Flu oroelastomer or TPE se ats do not use o-r ...

  • Graco 3A0410D - page 5

    Warnings 3A0410D 5 Wa r n i n g s The f ollowing w arnings are fo r the setup , use , grounding, maint enance, and repair of this equipment. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols ref er to procedure-specific risks. When these symbols appear in the body of this man ual, ref er ba c k to these W ar ...

  • Graco 3A0410D - page 6

    Warnings 6 3A0410D EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury . • Do not oper ate the unit when fa tigued or under th e influence of drugs or alcohol. • Do not e xceed the maxim um working pressure or te mperature r ating of the lo west r ated system component. See T echnical Da ta in all equipment man uals. • Use fluids ...

  • Graco 3A0410D - page 7

    Warnings 3A0410D 7 T O XIC FLUID OR FUMES HAZARD T o xic fluids or fumes can cause serious injur y or death if splashed in the e y es or on skin, inhaled, or swa ll ow e d . • Read MSDSs to kno w the specific hazards of the fluids y ou are using. • Route e x haust a wa y from work area. If diaphr agm ruptures, f luid ma y be e xhausted into t h ...

  • Graco 3A0410D - page 8

    Installation 8 3A0410D Installation Overview The T ypical Installation shown in F IG . 1 is only a guide f or selecting and installing system components. Contact your Gr aco distributor f or assistance in planning a sys- tem to suit your needs. Reference letters in the text, f or e xample (A), r ef er to the callouts in the figures. Key: Accessorie ...

  • Graco 3A0410D - page 9

    Installation 3A0410D 9 Tighten F asteners Bef ore mountin g and using the pump f or the first time, chec k and retorq ue all e xternal f asteners . F ollo w T orque Instructio ns , page 14, o r see the torque tag on yo ur pump . After the f irst da y of opera tion retorque the f asteners . Mount the Pump 1. V er ify that the bolts ho lding the pump ...

  • Graco 3A0410D - page 10

    Installation 10 3A0410D Solvent container s used when flushing: F ollow local code. Use only conductiv e metal containers, placed on a grounde d surf ace. Do not place the container on a non- conductive surface , such as paper or cardboard, which interrupts groun ding continuity . Check yo ur syste m electr ical cont inuity after th e initial insta ...

  • Graco 3A0410D - page 11

    Installation 3A0410D 11 Air Exhaust V e ntilation . T o provide a remote exhaust: 1. Remov e the muffler (U) from the pu mp air e xhaust por t (K). 2. Install a grou nded air e xhaust hose (S) a nd connect the muff ler (U) to the othe r end of the hose . Use muffler PN 111897, sold separ ately . The minimum size f or the air e xhaust hose is 1 in . ...

  • Graco 3A0410D - page 12

    Operation 12 3A0410D Operation Pressure Relief Pr ocedure 1. Shut off the air supply to th e pump . 2. Open the dispensing v alv e, if used. 3. Open the fluid dr ain v alv e (F) to relie v e fluid pres- sure. Ha ve a container r eady to catch the dr ainage . Flush the Pump Bef ore Fir st Use The pump w as tested in wa ter . If water could contami- ...

  • Graco 3A0410D - page 13

    Operation 3A0410D 13 Pump Shutdown At the end of the w ork shift and bef ore y ou chec k, adjust, clean or repair the system, follow the Pressure Relief Pr ocedure , page 12. Maintenance Maintenance Schedule Estab lish a pre v entiv e maintenance schedule ba sed on the pump’ s ser vice histor y . Scheduled maintenance is especially impor tant to ...

  • Graco 3A0410D - page 14

    Operation 14 3A0410D T or que Instructions See F IG . 5 fo r fluid cov er and air valv e fastener s. See F IG . 6 f or manif old fasten ers. NO TE: Fluid cov er and manifold f asteners on the poly- propylene pumps hav e a thread-locking adhesive patch applied to the threads. If this pa tch is excessiv ely wor n, the f asteners ma y loosen during op ...

  • Graco 3A0410D - page 15

    Operation 3A0410D 15 F IG . 6. T orque Instructions - Manifold F asteners Polypropylene ti16564a 10 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1-8 Aluminum ti16559a 12 11 10 9 14 13 15 16 1-8 12 5 1 4 8 10 11 6 3 2 7 9 Stainless Steel ti17457a ...

  • Graco 3A0410D - page 16

    Aluminum Pump Dimension s 16 3A0410D Aluminum Pump Dimensions ti16557a ti16558a ti16559a A B D C E F G Air Inlet (opposite side from muffler) H J K L M A 24.50 in. (62. 2 cm) B 28.63 in. (72. 7 cm) C 4.13 in. (10.5 cm) D 32.56 in. (82. 7 cm) E 12.04 in. (30. 6 cm) F 24.08 in. (61. 2 cm) G 19.70 in. (50 .0 cm) H 8.25 in. (21.0 cm) J 16.91 in. (42 .9 ...

  • Graco 3A0410D - page 17

    Polypropylene Pump Dimensi ons 3A0410D 17 P olypr opylene Pump Dimensions ti16562a ti16563a ti16564a A B C D H J K L E F G Air Inle t (opposite side from muffler) M A 36.80 in. (93. 5 cm) B 41.40 in. (105.2 cm) C 45.34 in. (115.2 cm) D 4.60 in. (11.7 cm) E 14.56 in. (37. 0 cm) F 29.12 in. (74. 0 cm) G 26.69 in. (67. 8 cm) H 8.30 in. (21.1 cm) J 16. ...

  • Graco 3A0410D - page 18

    Stainless Steel Pump Dimension s 18 3A0410D Stainless Steel Pump Dimensions ti17455a ti17456a ti17457a A B C D H J K L E F G M Air Inlet (opposite side from muffler) A 23.8 in. (60.5 cm) B 27.88 in. (70. 8 cm) C 30.5 in. (77.5 cm) D 4.5 in. (11.4 cm ) E 12.34 in. (31. 3 cm) F 24.68 in. (62. 7 cm) G 19.38 in. (49 .2 cm) H 8.25 in. (21.0 cm) J 16.91 ...

  • Graco 3A0410D - page 19

    Performance Charts 3A0410D 19 Pe r f o r m a n c e C h a r t s T est Conditions: Pump tested in wate r with inlet submerged . A B C D How to Read the Charts 1. Locate fluid f low r ate along bottom of chart. 2. F ollow v er tical line up to intersection with selec ted operating air pressure curve . 3. Follow left to scale to read fluid outlet press ...

  • Graco 3A0410D - page 20

    Technica l Data 20 3A0410D T echnical Data Husky 3300 US Metric Maxim um fluid w orking pressure Aluminum or Stainle ss Steel with Aluminum Center Sectio n 125 psi 0.86 MPa, 8.6 bar P olypropylene or Stainless Steel with P olypropylen e Center Section 100 psi 0.7 MP a, 7 bar Air pressure operating range** Aluminum or Stainle ss Steel with Aluminum ...

  • Graco 3A0410D - page 21

    Technical Data 3A0410D 21 Inlet/Outlet Si zes Fluid inlet - P olyprop ylene 3 in. ANSI/DIN flange Fluid inlet - Aluminum 3 in.-8 npt or 3 in. -11 bspt with 3 in. ANSI/DIN flange Fluid inlet - Stainless St eel 3 in.-8 npt or 3 in.-1 1 bspt Air Inlet - all p umps 3/4 in. npt( f) We t t e d p a r t s All pumps Materials chosen f or seat, ball, and dia ...

  • Graco 3A0410D - page 22

    Technica l Data 22 3A0410D Fluid T emperature Range * Th e maximum tempe rature liste d is based on the A TEX standard f or T4 temperature cla ssification. If y ou are operat ing in a non-e xplosiv e en vironment, FKM f luoroelastomer’ s maximum fluid temper ature in alumin um pumps is 320°F (160°C). NO TICE T emperature limits are ba sed on me ...

  • Graco 3A0410D - page 23

    Technical Data 3A0410D 23 ...

  • Graco 3A0410D - page 24

    All written and visual data con tained in th is document reflects the late st product information availabl e at the time of publica tion. Graco reserves the right to make changes at any time without notice. Original instructions. This manua l contains English. MM 3A0410 Graco Headquarters: Minneapoli s Internationa l Offices: Belgium, China, Japan, ...

メーカー Graco カテゴリー Heat Pump

Graco 3A0410Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3A0410Dの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 3A0410Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 3A0410Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 3A0410Dの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 3A0410Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 3A0410Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 3A0410Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 3A0410Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 3A0410Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 3A0410Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 3A0410Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 3A0410Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 3A0410Dデバイスの基本機能を使うにあたってのヒント。 Graco 3A0410Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 3A0410Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 3A0410Dのメーカー/サービスへの連絡先に関する情報。

Graco 3A0410Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 3A0410Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 3A0410Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)