Graco Hydra-Clean 800-094の取扱説明書

15ページ 1.27 mb
ダウンロード

ページに移動 of 15

Summary
  • Graco Hydra-Clean 800-094 - page 1

    This manual contains IMPORTANT READ AND RETAlN FOR REFERENCE WARNINGS and INSTRUCTIONS Q P/N 800-093 SERIES "A" - CART MODEL P/N 800-094 SERIES "A" - HANDLE MODEL 800 psi (55 bar) OPERATING PRESSURE 1 100 psi (76 bar) MAXIMUM WORKING PRESSURE ...

  • Graco Hydra-Clean 800-094 - page 2

    UNJECTUON HAZARD Fluids under high pressure from spray or leaks can penetrate the skin and cause extremely serious injury. including the need for amputation. NEVER point the spray gun at anyone or any part of the body. NEVER put hand or fingers over the spray tip. NEVER try to stop or deflect leaks with your hand or body. ' ' MEDICAL TREA ...

  • Graco Hydra-Clean 800-094 - page 3

    .. . . .. ~. j CART MOTOR CONTROL POWER COR0 HANDLE MODEL ADJUSTABLE NOZZLE CONTROL RING 3/4" GARDEN HOSE THREAD SPRAYTIP H6") 4 PRESSURE 4 HIGH PRESSURE AOJUSTMENT HOSE I30 FT.) KNOB Check For Damage Check unit for any damage that may have occurred in shipping. Any damage should be noted and the carrier notified immediately. Check unit&a ...

  • Graco Hydra-Clean 800-094 - page 4

    Connect To Water Supply -CAUTION plumbing codes regarding cross-connection to water supply. Optional backflowpreventorP/N 801-1 33 is available to prevent the back-up of Do not exceed 1 GOOF (70'C) water temperature to pump in a direct supply system. from your city water supply to the units 3/d inch Connect a hose with at least 3/4 inch (19 mm ...

  • Graco Hydra-Clean 800-094 - page 5

    Turn control ring on adjustable nozzle clockwise to cause a drop in pressure. Start pressure washer unit and trigger spray gun. The. injector may draw momentarily as system is filling but actuate injector, turn chemical adjustment knob out. normally will stop as system builds up to full pressure. To counterclockwise. until chemical begins to be dra ...

  • Graco Hydra-Clean 800-094 - page 6

    SERVICE Troubleshooting PROBLEM Low.Pressure rump runs extremely rough, pressure low. iNater leakage from under :he manifold. iNater in pump crankcase. Zrequent or premature 'ailure of the packing. jtrong surging at the inlet Ind low pressure on the lischarge side. hit will not start. :hemica1 injection system oesn't work. r leaks. pray g ...

  • Graco Hydra-Clean 800-094 - page 7

    ... . : .. .. ,. BARBS DRAWING Pressure Washer A 33. WIRING DIAGRAM 801-888 7 ...

  • Graco Hydra-Clean 800-094 - page 8

    PARTS LIST Pressure Washer Assembly, 800-093. 800-094 REF. PART NO. NO. 800-093 800-094 i 800.154 2 800.157 4 801-931 3 801-859 5 801-929 6 801-966 7 801-930 8 801-893 10 801.884 9 801.884 11 801-226 12 801-304 13 801-221 14 801-894 15 801-605 16 801-606 17 801-875 19 801-882 18 801.876 21 801-967 20 *EO1 -883, 22 801.677 23 801-683 24 801-129 25 8 ...

  • Graco Hydra-Clean 800-094 - page 9

    PARTS DRAWING Pump/Motcr Asse PARTS LIST Pump/Motor Assembly, 800-1 54 REF. PART NO. NO. DESCRIPTION QTY DESCRIPTION QTY 1 801-862 MOTOR, 1.5 hp, "C Face .NO. NO. 1 2 801-864 PUMP, T-9791, see parts 16 801-023 WASHER, Flat, 1/4 4 17 801-139 WASHER, Lock. 1/4 drawing, page 11 4 3 801-870 COUPLER HOUSING 1 1 18 801.546 BOLT, Hex Hd., 3/8-16x 1-1 ...

  • Graco Hydra-Clean 800-094 - page 10

    SERVICE Pump (Refer to Parts Drawing, Page 11) MOTE: Three sizes of metric wrenches are M17, and M6 Allen wrench. necessary for servicing the. pump; M30, Valves: 1. Remove the hex plug (5) from manifold (6) using M30 wrench. 2. Examineo-ring(4)underplugandreplace'ifcutsor distortion exist. '3. Remove valve~unit and O-ring (3) from cavity. ...

  • Graco Hydra-Clean 800-094 - page 11

    PARTS DRAWING Pump, 8pl-864 " **PACKING & RETAINER KIT 801 -664 Includes: 'PLUNGER REPAIR REF. NO. QTY. 9 1 NO. KIT 801-474 Includes: REF. 'PACKING KIT *OIL SEAL KIT *VALVE UNIT KIT QTY. 10 1 15 3 801-662 11 1 16 3 12 1 NO. REF. 17 13 3 1 801-658 801 -472 REF. QTV. REF. NO. QTV. NO. 14 3 3 an. Includes: Includes: Includes: 18 3 1 ...

  • Graco Hydra-Clean 800-094 - page 12

    SERVICE Chemical injector The nozzle, check valve, valve seat, and needle valve may be cleaned by disassembling the chemical injector if clogging occurs within. or if downstream restriction increases in any As with any injector, if the spray tip becomes clogged manner, the injector will stop drawing chemical: The restriction should be eliminated be ...

  • Graco Hydra-Clean 800-094 - page 13

    ! NOTE: Hose. Swivel & Spray Tip are not included with Gun Assembly - See Pressure Washer Assembly Pans Drawing/List. page 7. 8. Gun Assembly, 800-1 57 SERVICE Gun, Cartridge Replacement 1. Press access pin (1 2) from gun handle and remove access plate (14) by sliding plate backwards. Remove cartridge (5) from housing (6) by using a 19 mm socke ...

  • Graco Hydra-Clean 800-094 - page 14

    ACCESSORIES (Must be purchased separately) CHEMICAL CLEANING COMPOUNDS: General Purpose Cleaner 800-1 06 Vehicle Wash 800-108 Heavy Duty Degreaser 800-1 07 supply. install upstream from pump. Metal Pretreatment, Phosphatizer 800-109 Paintable Rust Inhibitor 800- 1 10 BACK FLOW PREVENTOR 801 -1 33 Prevent back-up of contaminated water into fresh TEC ...

  • Graco Hydra-Clean 800-094 - page 15

    THE GRACQ WARRANTY Graco Inc. warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship under normal use and service. This warranty extends to the original purchaser for a perid of 12 months from the date of purchase and applies only when the equipment is installed and operated in accordance ...

メーカー Graco カテゴリー Pressure Washer

Graco Hydra-Clean 800-094のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Hydra-Clean 800-094の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco Hydra-Clean 800-094の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Hydra-Clean 800-094の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Hydra-Clean 800-094の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Hydra-Clean 800-094のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Hydra-Clean 800-094の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Hydra-Clean 800-094デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Hydra-Clean 800-094を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Hydra-Clean 800-094ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Hydra-Clean 800-094の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Hydra-Clean 800-094の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Hydra-Clean 800-094に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Hydra-Clean 800-094デバイスの基本機能を使うにあたってのヒント。 Graco Hydra-Clean 800-094のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Hydra-Clean 800-094に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Hydra-Clean 800-094のメーカー/サービスへの連絡先に関する情報。

Graco Hydra-Clean 800-094についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Hydra-Clean 800-094の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Hydra-Clean 800-094で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)