Napoleon Fireplaces Fireplaceの取扱説明書

22ページ 3.02 mb
ダウンロード

ページに移動 of 22

Summary
  • Napoleon Fireplaces Fireplace - page 1

    1 W415-0619 / B / 03.03.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE. GT8N NA TURAL GA ...

  • Napoleon Fireplaces Fireplace - page 2

    2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION W arranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING V enting Lengths and Air T erminal Locations Vent Installations T ypical V ent Installations - Horizontal T ermination T ypical V ent Installations - V ertical T ermination Minimum Air T erminal Lo ...

  • Napoleon Fireplaces Fireplace - page 3

    3 W415-0619 / B / 03.03.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® e following ma te rials and workmanship in your new NAPO LEON® gas firepla ce are waanted agains t defects for as long as you own the fireplace.  is covers: combus tion chamber , hea t changer , s tainle s t eel burner , gold pla ted par t s agains t tarn ...

  • Napoleon Fireplaces Fireplace - page 4

    4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important to know the speci fi cs that apply to your area, for example: in Massachusetts State: • The fi replace damper must be removed or welded in th ...

  • Napoleon Fireplaces Fireplace - page 5

    5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner . Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! Do not ...

  • Napoleon Fireplaces Fireplace - page 6

    6 W415-0619 / B / 03.03.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning. Under extreme vent con fi gurations, allow several minutes (5-15) for the fl ame to stabilize after igniti ...

  • Napoleon Fireplaces Fireplace - page 7

    7 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - HORIZONT AL TERMINA TION MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) N/A 1 Rise per foot (recommended) 1/4” N/A Rise per foot (allowable) 0” N/A Horizontal run (If vent run does not include vertical rise) 4” 24” 2a Horizontal ru ...

  • Napoleon Fireplaces Fireplace - page 8

    8 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - VERTICAL TERMINA TION 24” MIN. MINIMUM VERITICAL 4” MIN. FIGURE 3a 24” MIN. MINIMUM VERITICAL MAXIMUM HORIZONT AL 5 FT MAX. 15 FT MAX. 4” MIN. MAXIMUM VERTICAL 19 1/2 FT MAX. 4” MIN. MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) ...

  • Napoleon Fireplaces Fireplace - page 9

    9 W415-0619 / B / 03.03.08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL L OCA TION CLEARANCES N D E O FIGURE 4 ...

  • Napoleon Fireplaces Fireplace - page 10

    10 W415-0619 / B / 03.03.08 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high. 1. Apply a bead of caulking all around and place the fi restop ...

  • Napoleon Fireplaces Fireplace - page 11

    11 W415-0619 / B / 03.03.08 1. Stretch the 3” fl exible vent pipe to the required length taking into account the additional length needed for the fi nished wall surface. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied). Slip the fl exible vent pipe a minimum of 2” over the inner sleeve of the air terminal and secur ...

  • Napoleon Fireplaces Fireplace - page 12

    12 W415-0619 / B / 03.03.08 HIGH TEMPERA TURE SEALANT 1 1 / 2 ” OVERLAP SCREWS 1. Install the 3” fl exible vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied). 2. Install the 5” fl exible vent pipe to the fi replace. Attach and seal the joints ...

  • Napoleon Fireplaces Fireplace - page 13

    13 W415-0619 / B / 03.03.08 Do NOT use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TEL Y to have the fi replace inspected for damage to the electrical circuit. IT IS NECESSAR Y T O HARD WIRE THIS FIREPLACE. Permanently framing the fi replace with an enclosure, requires the fireplace junction box to ...

  • Napoleon Fireplaces Fireplace - page 14

    14 W415-0619 / B / 03.03.08 FRAMING FIGURES 21a,b&c NAILING T AB INST ALLA TION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 The has been designed to be installed mid-way up a wall. When installing this unit close to the fi nished fl ...

  • Napoleon Fireplaces Fireplace - page 15

    15 W415-0619 / B / 03.03.08 2” MIN.* 12” MIN. TO COMBUSTIBLES (to ceiling or mantle) 1 1 / 2 ” MIN. * Any protruding finishing material installed in this space (ie. baseboards) must leave 2” of unobstructed clearance to allow for full rotation of the control door . COMBUSTIBLE NON-COMBUSTIBLE 1” 1” 0” IF NON-COMBUSTIBL E FINISHING IS ...

  • Napoleon Fireplaces Fireplace - page 16

    16 W415-0619 / B / 03.03.08 FIGURE 28 RECEIVING SLOTS DOOR STOP CHAIN FRAME/FRONT INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied. Figure 26 2. Install the top trim bracket to the fi rebox using the three #9 ...

  • Napoleon Fireplaces Fireplace - page 17

    17 W415-0619 / B / 03.03.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the fi replace. 2 . Remove the frame from the unit by removing the 2 black securing screws from the top, and the 2 silver hex head securing screws from the bottom. 3 . Lay the frame down on its front, being careful not to scratch the fi ...

  • Napoleon Fireplaces Fireplace - page 18

    18 W415-0619 / B / 03.03.08 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Do not use this fi replace if an ...

  • Napoleon Fireplaces Fireplace - page 19

    19 W415-0619 / B / 03.03.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established. NOTE: It ...

  • Napoleon Fireplaces Fireplace - page 20

    20 W415-0619 / B / 03.03.08 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BURNER 7 W357-0006 IGNITOR 8 W190-0026 CONTROL, MODULE 9* W750-0183 WIRE HARNESS 10* W750-0184 IGNITION CABLE 1 1 W200-0234 IGNITOR COVER 12 W200-0233 BU ...

  • Napoleon Fireplaces Fireplace - page 21

    21 W415-0619 / B / 03.03.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to spark for complete 7 seconds, burner shuts down. Hot and neutral wires are re ...

  • Napoleon Fireplaces Fireplace - page 22

    22 W415-0619 / B / 03.03.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

メーカー Napoleon Fireplaces カテゴリー Indoor Fireplace

Napoleon Fireplaces Fireplaceのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Fireplaceの取扱説明書
- Napoleon Fireplacesの製品カード
- パンフレット
- またはNapoleon Fireplaces Fireplaceの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napoleon Fireplaces Fireplaceの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napoleon Fireplaces Fireplaceの取り付け説明書、サービスマニュアル、簡易説明書、またはNapoleon Fireplaces Fireplaceのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napoleon Fireplaces Fireplaceの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Napoleon Fireplaces Fireplaceデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapoleon Fireplaces Fireplaceを使用するのを助ける技術的文書のことです。説明書は通常、全てのNapoleon Fireplaces Fireplaceユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napoleon Fireplacesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napoleon Fireplaces Fireplaceの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapoleon Fireplaces Fireplaceの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napoleon Fireplaces Fireplaceに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napoleon Fireplaces Fireplaceデバイスの基本機能を使うにあたってのヒント。 Napoleon Fireplaces Fireplaceのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napoleon Fireplaces Fireplaceに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapoleon Fireplaces Fireplaceのメーカー/サービスへの連絡先に関する情報。

Napoleon Fireplaces Fireplaceについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapoleon Fireplaces Fireplaceの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapoleon Fireplaces Fireplaceで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)