    W415-0594 / A / 02.15.07 1 W415-0442 / C / 09.01.03 ...

  • Napoleon Fireplaces NZ6000 - page 2

    W415-0594 / A / 02.15.07 2 WARNINGS & SAFETY PRECA UTIONS ...

  • Napoleon Fireplaces NZ6000 - page 3

    W415-0594 / A / 02.15.07 3 T ABLE of CONTENTS PLEASE RET AIN THIS MANU AL FOR FUTURE REFERENCE PG 2 -6 INTRODUCTION Warnings and safety precautions Warranty General Instructions General Information Care of Glass & Plated Parts 7 HI-EFFICIENCY HEA TING 7- 14 INST ALLA TION / FRAMING Location & Clearance Framing Outside Combustion Air Mantel ...

  • Napoleon Fireplaces NZ6000 - page 4

    W415-0594 / A / 02.15.07 4 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a q ...

  • Napoleon Fireplaces NZ6000 - page 5

    W415-0594 / A / 02.15.07 5 INTRODUCTION GENERAL INSTRUCTIONS 1. Combustion and dilution air is brought into the unit through the fresh air intake collars located on the top rear of the unit. 2. The combustion air is brought into the firebox through many small holes in the airwash located at the top and sides of the opening. 3. The dilution air is i ...

  • Napoleon Fireplaces NZ6000 - page 6

    W415-0594 / A / 02.15.07 6 If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fire will clean the glass. The most common reasons for dirty glass include: not using sufficient fuel to get the stove thoroughly hot, using green or wet wood, closing the draft so far that there is insuf- ficient air for ...

  • Napoleon Fireplaces NZ6000 - page 7

    W415-0594 / A / 02.15.07 7 4 3 / 8 " 19 3 / 8 " 25 3 / 16 " 51 1 / 2 " 50 1 / 4 " 43" 6 1 / 2 " 29 1 / 2 " 48 5 / 8 " 27 1 / 2 " 41 " 49 1 / 2 " 30 3 / 4 " 8 " 15 " 24 3 / 4 " 10 3 / 4 " 6 5 / 8 " 24 " 30 3 / 4 " 61 1 / 2 " 50 " 30 3 / 4 &q ...

  • Napoleon Fireplaces NZ6000 - page 8

    W415-0594 / A / 02.15.07 8 Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clear- ance to combu ...

  • Napoleon Fireplaces NZ6000 - page 9

    W415-0594 / A / 02.15.07 9 The fireplace face and enclosure ceiling must be framed using 2x4 metal studs. The minimum enclosure ceiling height is 7 feet. Non-combustible materials (cement board and metal studs) must be used. WHEN USING A SOLID P ACK CHIMNEY WHEN USING AN AIR COOLED CHIMNEY ...

  • Napoleon Fireplaces NZ6000 - page 10

    W415-0594 / A / 02.15.07 10 The Napoleon Model NZ6000 takes outside air directly into the fireplace through the openings in the left and right hand sides. Decide on the most convenient lo- cation for the fresh air inlet ducts and hoods which may be installed above or below floor level. The fresh air inlet ducts and hoods must be The fresh air inlet ...

  • Napoleon Fireplaces NZ6000 - page 11

    W415-0594 / A / 02.15.07 11 An acceptable 61½" x 20" non-combustible (ie: brick, stone or ceramic tile) hearth extension must be installed. Hearth must extend 20" in front of the faceplate when it is not elevated (see local building codes). Hearth must extend a minimum of 6" to both sides of the unit (61 ½"). Hearth must ...

  • Napoleon Fireplaces NZ6000 - page 12

    W415-0594 / A / 02.15.07 12 HEARTH EXAMPLES ELEV A TED HEARTH RAISED HEARTH ELEV A TED / RAISED HEARTH ...

  • Napoleon Fireplaces NZ6000 - page 13

    W415-0594 / A / 02.15.07 13 FA CE PLA TE, UPPER GRILL, KEY ST ONE & DOOR INST ALLA TION 1 Remove the facing template held in place with the 12 screws shown. Dis- card the screws and template. 2 Mount the keystone and upper grill to the face- plate, as shown, using the 4 nuts supplied. Secure the faceplate to the unit, using the 12 screws suppli ...

  • Napoleon Fireplaces NZ6000 - page 14

    W415-0594 / A / 02.15.07 14 A raised hearth together with the fireplace built on a raised platform is recommended for easier wood loading and fire viewing. The diameter of the chimney is 8". A chimney venting the fireplace shall not vent any other appliance . The minimum overall chimney height from the top of the fireplace is 15 feet. The maxi ...

  • Napoleon Fireplaces NZ6000 - page 15

    W415-0594 / A / 02.15.07 15 4 ELBOWS 2 ELBOWS STRAIGHT UP No Off-Set. Minimum overall chim- ney height is 15 feet. Single off-set with two 15°, 30° or 45° elbows. Minimum overall chimney height is 15 feet. Double off-set with four 15°, 30° or 45° elbows. Minimum overall chim- ney height is 15 feet. * The first flue offset closest to the top o ...

  • Napoleon Fireplaces NZ6000 - page 16

    W415-0594 / A / 02.15.07 16 The first flue offset closest to the top of the unit must be a minimum distance of 12" from the top of the fireplace. Attach an elbow to the chimney section, angled toward the offset. Secure with 3 - #8X1/2" sheet met al screws. T o achieve the minimum offset, attach and secure a second elbow . T o achieve long ...

  • Napoleon Fireplaces NZ6000 - page 17

    W415-0594 / A / 02.15.07 17 The Napoleon Model NZ6000 may be connected to either a lined or unlined masonry chimney . IF THE CHIMNEY IS LINED, the flues must be made of vitrified clay and be in sizes of 8" square or 8" round (inside diameters) or 8"x12" with a minimum height of 15 feet above the fireplace. Eight inch round flues ...

  • Napoleon Fireplaces NZ6000 - page 18

    W415-0594 / A / 02.15.07 18 The door latch is adjusted by moving the washer from one side of the latch to the other . T ighten the outer nut to secure the latch. FINISHING Install the air control threaded rod and knob. A TT ACHING THE HANDLE AND AIR CONT OL KNOB AIR COOLED CHIMNEY INST ALLA TION 1. Remove the knock out. 2. Cut away the insulation t ...

  • Napoleon Fireplaces NZ6000 - page 19

    W415-0594 / A / 02.15.07 19 FIREBRICK AND BAFFLE INST ALLA TION OPTIONAL NZ64 BL O WER KIT INST ALLA TION Route a 120 V olt, 60Hz electrical supply (not supplied) from the electrical box on the side of the unit to the electrical box on the blower housing. The unit comes complete with a safety switch and a ther- mally activated switch. For complete ...

  • Napoleon Fireplaces NZ6000 - page 20

    W415-0594 / A / 02.15.07 20 3. Connect the 6” collar to the blower opening located on the side of the unit. An optional opening is covered on the other side of the unit. If this location is preferred, switch the cover plate and collar . Secure by reaching through the collar and bending the tabs. Use sealant to ensure that the connection is air ti ...

  • Napoleon Fireplaces NZ6000 - page 21

    W415-0594 / A / 02.15.07 21 6. Insert the filter into the grill. Foam gasket ( 1 / 2 ” weather stripping) between the grill and blower housing is recom- mended, but not supplied. The blower filter is washable. 7. The bottom lip of the grill latches over the bottom lip of the housing. Use two screws to secure the top of the grill to the facing. 5. ...

  • Napoleon Fireplaces NZ6000 - page 22

    W415-0594 / A / 02.15.07 22 NZ64 BLOWER REPLACEMENT 1. Remove the grill and filter by removing the 2 securing screws. 2. Remove the nut securing the blower bracket to the hous- ing. 3. Lift the handles to pull the blower and bracket off of the stud. 4. Slide the bracket and blower out of the housing. 5. Disconnect the wire connector from the blower ...

  • Napoleon Fireplaces NZ6000 - page 23

    W415-0594 / A / 02.15.07 23 Roll up some newspaper , light it and place it near the fire- place flue until the chimney begins to draw . When a fire is burning, open the door slowly to avoid drawing smoke into the room. A properly installed Napoleon fireplace should not smoke. If yours does, check the following: Has the chimney had time to get hot? ...

  • Napoleon Fireplaces NZ6000 - page 24

    W415-0594 / A / 02.15.07 24 5. T o maintain a brisk fire, a hot coal bed must be estab- lished and maintained. 6. Slowly add larger wood (2x4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between, so that the primary air can flow directly into this trench and ignite the fuel above. 7. When the f ...

  • Napoleon Fireplaces NZ6000 - page 25

    W415-0594 / A / 02.15.07 25 Can't get the fireplace operating? Use more kindling and paper . Assuming the chimney and vent are sized correctly and there is sufficient combustion air , the lack of sufficiently dry quantities of small kindling is the problem. Thumb size is a good gauge for small kindling diameter . Can't get heat out of the ...

  • Napoleon Fireplaces NZ6000 - page 26

    W415-0594 / A / 02.15.07 26 A bed of ashes approximately 1 inch deep should be left on the firebox bottom to help maintain a hot charcoal bed. When the fire has burned down and cooled, remove any excess ashes. T o remove the ash, follow the directions below . 1. A fter the last coal has extinguished, let the fireplace cool at least two hours. 2. Op ...

  • Napoleon Fireplaces NZ6000 - page 27

    W415-0594 / A / 02.15.07 27 At the end of each burning season inspect the door gasket ensuring that it is not worn or loose. Replace with proper fibreglass rope. The purpose of door gasketing is to seal the firebox. If the doors are not sealed, air leaks into the firebox, creating a quick burning fire. This situation is not desireable for overnight ...

  • Napoleon Fireplaces NZ6000 - page 28

    W415-0594 / A / 02.15.07 28 When wood is burned slowly , it produces t ar and other organic vapours which combine with expelled moisture to form creosote. These vapours condense in the relatively cooler chimney flue of a slow burning fire and when ig- nited, make an extremely hot fire. Check your chimney for creosote and soot build-up monthly until ...

  • Napoleon Fireplaces NZ6000 - page 29

    W415-0594 / A / 02.15.07 29 # P ART N O. DESCRIPTION 1 W300-0069 DOOR GLASS 2* W562-0035 DOOR OR GLASS GASKET 3* W562-0036 DOOR GASKET - CENTRE 4* W010-1225 GLASS & GASKET 5* W690-0005 120V THERMOSTA T 6 W090-0099 REAR FIREBRICK 7 W090-0101 BOTTOM RIGHT FIREBRICK 8 W090-0100 BOTTOM LEFT FIREBRICK 9 W090-0098 RIGHT SIDE FIREBRICK 1 0 W090-0097 L ...

  • Napoleon Fireplaces NZ6000 - page 30

    W415-0594 / A / 02.15.07 30 ...

  • Napoleon Fireplaces NZ6000 - page 31

    W415-0594 / A / 02.15.07 31 Smoke enters the room during start- up. Cold air blockage. - burn a piece of newspaper to establish a draft. Close the doors. - if the flame is not getting enough air , first make sure the air control is open. If additional air is needed, open the doors a small crack only . - open the by-pass damper TR OUBLE SHOO TING GU ...

  • Napoleon Fireplaces NZ6000 - page 32

    W415-0594 / A / 02.15.07 32 RA TING PLA TE RA TING PLA TE IS LOCA TED BEHIND THE FIREPLA CE F ACEPLA TE. ...

メーカー Napoleon Fireplaces カテゴリー Indoor Fireplace

Napoleon Fireplaces NZ6000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NZ6000の取扱説明書
- Napoleon Fireplacesの製品カード
- パンフレット
- またはNapoleon Fireplaces NZ6000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napoleon Fireplaces NZ6000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napoleon Fireplaces NZ6000の取り付け説明書、サービスマニュアル、簡易説明書、またはNapoleon Fireplaces NZ6000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napoleon Fireplaces NZ6000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Napoleon Fireplaces NZ6000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapoleon Fireplaces NZ6000を使用するのを助ける技術的文書のことです。説明書は通常、全てのNapoleon Fireplaces NZ6000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napoleon Fireplacesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napoleon Fireplaces NZ6000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapoleon Fireplaces NZ6000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napoleon Fireplaces NZ6000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napoleon Fireplaces NZ6000デバイスの基本機能を使うにあたってのヒント。 Napoleon Fireplaces NZ6000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napoleon Fireplaces NZ6000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapoleon Fireplaces NZ6000のメーカー/サービスへの連絡先に関する情報。

Napoleon Fireplaces NZ6000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapoleon Fireplaces NZ6000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapoleon Fireplaces NZ6000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)