    BLUE FLAME VENT -FREE PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors ...

  • Vanguard Heating VP2000BTD - page 2

    2 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These i ...

  • Vanguard Heating VP2000BTD - page 3

    3 104401 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Prote ...

  • Vanguard Heating VP2000BTD - page 4

    4 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. D ...

  • Vanguard Heating VP2000BTD - page 5

    5 104401 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas ...

  • Vanguard Heating VP2000BTD - page 6

    6 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® Figure 3 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" o ...

  • Vanguard Heating VP2000BTD - page 7

    7 104401 OWNER’S MANUAL INST ALLA TION WARNING: A qualified ser- vice person must install heater. Follow all local codes. CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have t ...

  • Vanguard Heating VP2000BTD - page 8

    8 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® Models VP2800BTD Models VP2000BTD Figure 8 - Mounting Bracket Clearances WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clear- ances from floor and joining wall. 18 3/4" Min. 11" Min. 16" Adjoining Wall Only Insert Mounting Screws Through Last Hole On ...

  • Vanguard Heating VP2000BTD - page 9

    9 104401 OWNER’S MANUAL Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater. Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket ont ...

  • Vanguard Heating VP2000BTD - page 10

    10 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® Figure 14 - Gas Connection * A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories , page 17. INST ALLA TION Continued CON ...

  • Vanguard Heating VP2000BTD - page 11

    11 104401 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator . 2. Cap of f open end of gas pipe w ...

  • Vanguard Heating VP2000BTD - page 12

    12 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figur e 7, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Procedures . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights. 4. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. Afte ...

  • Vanguard Heating VP2000BTD - page 13

    13 104401 OWNER’S MANUAL Figure 20 - Incorrect Pilot Flame Pattern INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermo ...

  • Vanguard Heating VP2000BTD - page 14

    14 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode positio ...

  • Vanguard Heating VP2000BTD - page 15

    15 104401 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit REMEDY 1. Clean burner (see Cleaning and Mainte- nance , page ...

  • Vanguard Heating VP2000BTD - page 16

    16 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach y ...

  • Vanguard Heating VP2000BTD - page 17

    17 104401 OWNER’S MANUAL TECHNICAL SER VICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190. You can also visit DESA International’s technical service web site at www.desatech.com. SPECIFICA TIONS SER VICE HINTS When Gas Pr ...

  • Vanguard Heating VP2000BTD - page 18

    18 104401 BLUE FLAME PROP ANE/LP GAS HEA TER ® ODS/Pilot Assembly 12-1 ILLUSTRA TED PA R T S BREAKDOWN VP2000BTD VP2800BTD 12-2 1 2 3 4 5 6 8 9 10 10 11 12 13 14 15 17 19 20 21 22 23 16 24 7 18 ...

  • Vanguard Heating VP2000BTD - page 19

    19 104401 OWNER’S MANUAL P ARTS LIST VP2000BTD VP2800BTD This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY PART NUMBER FOR NO. VP2000BTD VP2800BTD DESCRIPTION QTY. 1 098304-01 098304-01 Screw, #10 x 3/8" 2 2 098742-13 098742-14 ...

  • Vanguard Heating VP2000BTD - page 20

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased 104401-0 ...

メーカー Vanguard Heating カテゴリー Gas Heater

Vanguard Heating VP2000BTDのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VP2000BTDの取扱説明書
- Vanguard Heatingの製品カード
- パンフレット
- またはVanguard Heating VP2000BTDの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vanguard Heating VP2000BTDの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vanguard Heating VP2000BTDの取り付け説明書、サービスマニュアル、簡易説明書、またはVanguard Heating VP2000BTDのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vanguard Heating VP2000BTDの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vanguard Heating VP2000BTDデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVanguard Heating VP2000BTDを使用するのを助ける技術的文書のことです。説明書は通常、全てのVanguard Heating VP2000BTDユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vanguard Heatingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vanguard Heating VP2000BTDの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVanguard Heating VP2000BTDの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vanguard Heating VP2000BTDに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vanguard Heating VP2000BTDデバイスの基本機能を使うにあたってのヒント。 Vanguard Heating VP2000BTDのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vanguard Heating VP2000BTDに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVanguard Heating VP2000BTDのメーカー/サービスへの連絡先に関する情報。

Vanguard Heating VP2000BTDについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVanguard Heating VP2000BTDの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVanguard Heating VP2000BTDで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)