Honeywell L8104Bの取扱説明書

20ページ 1.03 mb
ダウンロード

ページに移動 of 20

Summary
  • Honeywell L8104B - page 1

    1 68-0063—3 J. H. • Rev. 6-95 • ©Honeywell Inc. 1995 L8104A,B,C,D Electr onic W ater Heater Contr ollers The L8104A,B,C,D Electronic Controllers pro- vide temperature control and ECO limit action for gas water heaters. L8104B with Potentiometer Remote Potentiometer Sensing Bulb ■ L8104A,B are used in standing pilot and electronic ignition ...

  • Honeywell L8104B - page 2

    68-0063—3 2 L8104A,B,C,D SPECIFICATIONS • ORDERING INFORMATION Specif ications IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and cali- brated under closely controlled conditions, and some m ...

  • Honeywell L8104B - page 3

    3 68-0063—3 L8104A,B,C,D SPECIFICATIONS DIMENSIONS: L8104: Fig. 1. L8104A,B: Fig. 2. L8104C,D: Fig. 3. APPROVALS: Underwriters Laboratories Inc. Component Recognized: File No. MP466, Guide No. MBPR2. American Gas Association Certified: Report No. 70-22A. Canadian Gas Association Certified: Report No. 1029- CC/T-6849. OTHER SYSTEM COMPONENTS (Orde ...

  • Honeywell L8104B - page 4

    68-0063—3 4 L8104A,B,C,D SPECIFICATIONS ACCESSORIES: L8104A: 4074ENP Potentiometer Assembly: 199075A Poten- tiometer: Clockwise turn increases temperature, two 18 in. [46 cm] leadwires with 1/4 in. quick connects. Washer and nut. 4074ENS Potentiometer Assembly: 199053A Potenti- ometer: Counterclockwise turn increases tempera- ture, two 18 in. (46 ...

  • Honeywell L8104B - page 5

    5 68-0063—3 L8104A,B,C,D INSTALLATION Installation WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a ...

  • Honeywell L8104B - page 6

    68-0063—3 6 L8104A,B,C,D INSTALLATION Fig. 5—L8104A with board-mounted potentiometer in a standing pilot application. M131C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1/4 IN. TAB TERMINALS (3). 3/16 IN. TAB TERMINALS (3). SENSING BULB WITH ECO SWITCH 1 2 2 2 3 3 3 L1 (HOT) L2 1 2 3 1 4 0 120 160 180 100 L8104A B ...

  • Honeywell L8104B - page 7

    7 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 7—L8104B with remote potentiometer in a standing pilot application. Fig. 8—L8104B with board-mounted potentiometer in an electronic ignition application. M130C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY JUMPER INSTALLED, DO NOT REMOVE. 1/4 IN. TAB TERMINALS (3 ...

  • Honeywell L8104B - page 8

    68-0063—3 8 L8104A,B,C,D INSTALLATION Fig. 9—L8104C with remote-mounted potentiometer in an electronic ignition application. SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE. ...

  • Honeywell L8104B - page 9

    9 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 10—L8104D with remote-mounted potentiometer in an electronic ignition application SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE. ...

  • Honeywell L8104B - page 10

    68-0063—3 10 L8104A,B,C,D SETTING AND CHECKOUT Setting and Check out SET CONTROL TEMPERATURE If the potentiometer is mounted on the control module, turn the selector knob to the desired temperature. If the potentiometer is remotely mounted, the position of the flat part of the shaft determines the approximate control temperature. Fully counterclo ...

  • Honeywell L8104B - page 11

    11 68-0063—3 L8104A,B,C,D SETTING AND CHECKOUT • OPERATION TABLE 2—THERMISTOR RESISTANCE AT VARIOUS TEMPERATURES IN CELSIUS. Operation L8104A,D When the temperature at the sensing bulb drops below the setting on the potentiometer, the relay contacts in the electronic control module make to open the gas control or turn on the ignition module. ...

  • Honeywell L8104B - page 12

    68-0063—3 12 L8104A,B,C,D TROUBLESHOOTING DISCONNECT SENSOR LEADS FROM ELECTRONIC CONTROL MODULE AND MEASURE RESISTANCE OF SENSOR(S) WITH OHMMETER. IS RESISTANCE BETWEEN 700K AND 30K OHMS (SEE TABLE 1)? SENSOR(S) OK. DISCONNECT ECO LEADS AND MEASURE RESISTANCE WITH OHMMETER. IS WATER TEMPERATURE GREATER THAN 210˚F AND ECO RESISTANCE LESS THAN 10 ...

  • Honeywell L8104B - page 13

    13 68-0063—3 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. SENSOR(S) MAY BE SHORTED OR OPEN. CHECK FOR LOOSE, BROKEN OR SHORTED WIRES. REPLACE SENSING BULB(S) IF NECESSARY. REPLACE ELECTRONIC CONTROL MODULE. RECONNECT A ...

  • Honeywell L8104B - page 14

    68-0063—3 14 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. NO YES CHECK VOLTAGE AT 24V TERMINALS OF ELECTRONIC CONTROL MODULE. IS THIS AN ELECTRONIC IGNITION SYSTEM WITH 100 PERCENT LOCKOUT? DISCONNECT 24V POWER AT IGNI ...

  • Honeywell L8104B - page 15

    15 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...

  • Honeywell L8104B - page 16

    68-0063—3 16 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...

  • Honeywell L8104B - page 17

    17 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...

  • Honeywell L8104B - page 18

    68-0063—3 18 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...

  • Honeywell L8104B - page 19

    19 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...

  • Honeywell L8104B - page 20

    68-0063—3 20 L8104A,B,C,D MATERIAL SAFETY DATA SHEET Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 Printed in U.S.A. customer.honeywell.com ...

メーカー Honeywell カテゴリー Water Heater

Honeywell L8104Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- L8104Bの取扱説明書
- Honeywellの製品カード
- パンフレット
- またはHoneywell L8104Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Honeywell L8104Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Honeywell L8104Bの取り付け説明書、サービスマニュアル、簡易説明書、またはHoneywell L8104Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Honeywell L8104Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Honeywell L8104Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHoneywell L8104Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのHoneywell L8104Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Honeywellの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Honeywell L8104Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHoneywell L8104Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Honeywell L8104Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Honeywell L8104Bデバイスの基本機能を使うにあたってのヒント。 Honeywell L8104Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Honeywell L8104Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHoneywell L8104Bのメーカー/サービスへの連絡先に関する情報。

Honeywell L8104Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHoneywell L8104Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHoneywell L8104Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)