Mitsubishi MSZ-GE42VAの取扱説明書

12ページ 関係なし
ダウンロード

ページに移動 of 12

Summary
  • Mitsubishi MSZ-GE42VA - page 1

    SPLIT -TYPE AIR CONDITIONERS INDOOR UNIT MSZ-GE22V A MSZ-GE25V A MSZ-GE33V A MSZ-GE35V A MSZ-GE42V A MSZ-GE50V A English OPERA TING INSTRUCTIONS For user • To use this unit correctly and safely , be sure to read these operating in- structions before use. SG79F320H04_Cover.indd 1 2010/04/29 7:40:27 ...

  • Mitsubishi MSZ-GE42VA - page 2

    En-1 ● OPERATING INSTRUCTIONS ● WARNING Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet. • This may cause overheating, fi re, or electric shock. Make sure the power plug is free of dirt and insert it se- curely into the outlet. • A dirty plug may cause fi re ...

  • Mitsubishi MSZ-GE42VA - page 3

    En-2 CAUTION Do not step on an unstable bench to operate or clean the unit. • This may cause injury if you fall down. Do not pull the power cord. • This may cause a portion of the core wire to break, which may cause overheating or fi re. Do not charge or disassemble the batteries, and do not throw them into a fi re. • This may cause the bat ...

  • Mitsubishi MSZ-GE42VA - page 4

    En-3 ● OPERATING INSTRUCTIONS ● RESET CLOCK • Make sure the polarity of the batteries is correct. • Do not use manganese batteries and leaking batteries. The remote controller could malfunction. • Do not use rechargeable batteries. • Replace all batteries with new ones of the same type. • Batteries can be used for approximately 1 year ...

  • Mitsubishi MSZ-GE42VA - page 5

    En-4 AUTO mode (Auto change over) The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is 2°C away from the set temperature for more than 15 minutes. Note: Auto Mode is not recommended if this indoor unit ...

  • Mitsubishi MSZ-GE42VA - page 6

    En-5 ● OPERATING INSTRUCTIONS ● ● OPERATING INSTRUCTIONS F AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I- SAVE OPERATION Press to select fan speed. Each press changes fan speed in the following order: • T wo short beeps are heard from the indoor unit when set to AUT O. • Use higher fan speed to cool/heat the room more powerfully . It is rec ...

  • Mitsubishi MSZ-GE42VA - page 7

    En-6 E CONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation. The unit performs swing operation vertically in various cycle according to the temperature of the unit. Set temperature is set 2°C higher automatically . Press again to cancel ECONO COOL operation. • ECONO COOL operation also is canceled when the V ANE button ...

  • Mitsubishi MSZ-GE42VA - page 8

    En-7 ● OPERATING INSTRUCTIONS ● Instr uctions: Air outlet and Fan (before cleaning, make sure that the fan is stopped) C LEANING 1 Turn the horizontal vanes down- ward. Then, remove the upper vane as shown in ➀ and ➁ . • Repeat ➀ and ➁ for the lower vane. 2 Swing out the two vertical vanes one by one. 4 Put the vertical vanes back to ...

  • Mitsubishi MSZ-GE42VA - page 9

    En-8 Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer. Symptom Explanation & Check points Indoor Unit The unit cannot be operated. • Is the breaker turned on? • Is the power supply plug connected? • Is the ON timer set? Page 6 All LED lamps on the indo ...

  • Mitsubishi MSZ-GE42VA - page 10

    En-9 ● OPERATING INSTRUCTIONS ● Installation place Avoid installing the air conditioner in the following places. • Where there is much machine oil. • Salty places such as the seaside. • Where sulfi de gas is generated such as a hot spring. • Where oil is splashed or where the area is fi lled with oily smoke. • Where there is high-fr ...

  • Mitsubishi MSZ-GE42VA - page 11

    SG79F320H04_en.indd 10 2010/04/29 7:48:13 ...

  • Mitsubishi MSZ-GE42VA - page 12

    HEAD OFFICE: T OKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN SG79F320H04 SG79F320H04_Cover.indd 2 2010/04/29 7:40:27 ...

メーカー Mitsubishi カテゴリー Air-conditioning

Mitsubishi MSZ-GE42VAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MSZ-GE42VAの取扱説明書
- Mitsubishiの製品カード
- パンフレット
- またはMitsubishi MSZ-GE42VAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi MSZ-GE42VAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi MSZ-GE42VAの取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi MSZ-GE42VAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi MSZ-GE42VAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Mitsubishi MSZ-GE42VAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi MSZ-GE42VAを使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi MSZ-GE42VAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi MSZ-GE42VAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi MSZ-GE42VAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi MSZ-GE42VAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi MSZ-GE42VAデバイスの基本機能を使うにあたってのヒント。 Mitsubishi MSZ-GE42VAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi MSZ-GE42VAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi MSZ-GE42VAのメーカー/サービスへの連絡先に関する情報。

Mitsubishi MSZ-GE42VAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi MSZ-GE42VAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi MSZ-GE42VAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)