    Solenoid Valve Replacement for 1030/1031 Compressor INTRODUCTION KEISER CORPORATION has always taken pride in designing and engineering the highest quality equipment on the market. This means that you will receive years of low maintenance and minimal repairs from every one of our machines. Only the highest quality products have the KEISER name on t ...

  • Keiser 1031 - page 2

    10-5508 Rev A Service Department (800) 888-7009 2 Solenoid Valve Replacement for 1030/1031 Compressor * WARNING: Unplug compressor before beginning. Before replacing valve, draw all of the air out of the compressor by pressing both the + and – buttons on the exercise equipment. When this is done, shut off valve to exercise equipment by turning th ...

  • Keiser 1031 - page 3

    10-5508 Rev A Service Department (800) 888-7009 3 Step Two: Remove hoses After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose. Unscrew nut counter-clockwise Next, cut the hose to the plastic elbow 3/8 inch from the end of t ...

  • Keiser 1031 - page 4

    10-5508 Rev A Service Department (800) 888-7009 4 Next, remove the lid to the computer control system box by unscrewing the screw on either side. remove two screws on lid Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole. pop out grommet Inside the computer control system box, cut all other zip ties ...

  • Keiser 1031 - page 5

    10-5508 Rev A Service Department (800) 888-7009 5 1030 Circuit Board Diagrams Rev A, B, C Rev D - Current ...

  • Keiser 1031 - page 6

    10-5508 Rev A Service Department (800) 888-7009 6 push on board, pull on wire Pull each of the four wires back out the hole one by one. Save the rubber grommet. There are four steps to Allenair® valve installation: 1 Adjust and mount new valve 2 Install single to double splitter and electrical wires 3 Secure and tie wires and replace lid 4 Test co ...

  • Keiser 1031 - page 7

    10-5508 Rev A Service Department (800) 888-7009 7 Step One: Adjust and mount new valve First, make sure that the valve is open. Try to turn the pet-cock on the valve counter- clockwise. If you cannot turn it further counter-clockwise, it is open. open valve counter-clockwise The new valve allows you to rotate its housing for easy mounting. Use the ...

  • Keiser 1031 - page 8

    10-5508 Rev A Service Department (800) 888-7009 8 Next, remove the compression nut that connects the hose to the valve. Replace it with the original compression nut, attach the hose, and tighten the compression nut finger tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn. Attach the second hose to the plastic elbow by using the needle ...

  • Keiser 1031 - page 9

    10-5508 Rev A Service Department (800) 888-7009 9 Left side valve Right side valve Repeat the process under Step One to mount the second valve. Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into ...

  • Keiser 1031 - page 10

    10-5508 Rev A Service Department (800) 888-7009 10 Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box. Replace the grommet in the hole. Next, install the single to ...

  • Keiser 1031 - page 11

    10-5508 Rev A Service Department (800) 888-7009 11 Take the single to double adapter and turn it so that the two top prongs are pointing to the left hand side of the box. The bent portion with these two prongs should be over the fuse. Replace the connector with the single to double adapter in L1. single to double adapter Reconnect the connector tha ...

  • Keiser 1031 - page 12

    10-5508 Rev A Service Department (800) 888-7009 12 Step Three: Secure and tie wires and replace lid Make sure that all of the slack is inside the computer control system box. Use a zip tie to bind the wires and hoses on the outside of the box. Use the wire cutters to cut off the excess. zip tie all wires and hoses Next, gather the four wires inside ...

  • Keiser 1031 - page 13

    10-5508 Rev A Service Department (800) 888-7009 13 feel for air flow After the flow of air has stopped, wait thirty seconds. Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start. Open the valve by turning the handle counter-clockwise to allow the air to reach the equipment. Open valve by turning counter-clo ...

  • Keiser 1031 - page 14

    10-5508 Rev A Service Department (800) 888-7009 14 2470 S. Cherry Ave. Fresno, CA 93706 1(800) 888-7009 Fax: (559 )256-8100 e-mail: info@keiser.com www.keiser.com ...

メーカー Keiser カテゴリー Air Compressor

Keiser 1031のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1031の取扱説明書
- Keiserの製品カード
- パンフレット
- またはKeiser 1031の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Keiser 1031の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Keiser 1031の取り付け説明書、サービスマニュアル、簡易説明書、またはKeiser 1031のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Keiser 1031の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Keiser 1031デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがKeiser 1031を使用するのを助ける技術的文書のことです。説明書は通常、全てのKeiser 1031ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Keiserの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Keiser 1031の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははKeiser 1031の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Keiser 1031に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Keiser 1031デバイスの基本機能を使うにあたってのヒント。 Keiser 1031のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Keiser 1031に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるKeiser 1031のメーカー/サービスへの連絡先に関する情報。

Keiser 1031についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもKeiser 1031の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがKeiser 1031で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)