Baldor MN754の取扱説明書

26ページ 0.32 mb
ダウンロード

ページに移動 of 26

Summary
  • Baldor MN754 - page 1

    High Resolution Analog Input / Output Expansion Board Catalog No. EXBHH005A01 2/06 MN754 Installation and Operating Manual ...

  • Baldor MN754 - page 2

    Any trademarks used in this manual are the property of their respective owners. ...

  • Baldor MN754 - page 3

    T able of Contents T able of Contents i Section 1 General Information 1‐1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 1‐1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limited W arranty 1‐2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Notice 1‐3 . . . . . . . . ...

  • Baldor MN754 - page 4

    ii T able of Contents ...

  • Baldor MN754 - page 5

    Section 1 General Information General Information 1‐1 Introduction The Baldor controls represent the latest technology in microprocessor based motor controls. In addition to the user programmable parameters available in every control, many different expansion boards are available from Baldor to further customize the control to most any applicatio ...

  • Baldor MN754 - page 6

    1‐2 General Information Limited W arranty For a period of two (2) years from the date of original purchase, BALDOR will repair or replace without charge controls and accessories which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, a ...

  • Baldor MN754 - page 7

    General Information 1‐3 Safety Notice This equipment contains voltages that may be as great as 1000 volts! Electrical shock can cause serious or fatal injury . Only qualified personnel should attempt the start‐up procedure or troubleshoot this equipment. This equipment may be connected to other machines that have rotating parts or parts that ar ...

  • Baldor MN754 - page 8

    1‐4 General Information W ARNING: Improper operation of control may cause violent motion of the motor shaft and driven equipment. Be certain that unexpected motor shaft movement will not cause injury to personnel or damage to equipment. Peak torque of several times the rated motor torque can occur during control failure. W ARNING: Motor circuit m ...

  • Baldor MN754 - page 9

    Section 2 Expansion Board Description Description 2‐1 Introduction High Resolution Analog Expansion Board Catalog No. EXBHH005AXX. When this board is installed, two high resolution analog inputs are provided in addition to the two standard analog outputs. Features: T wo (2) Analog Inputs T wo (2) Analog Outputs 16 Bit Digital Resolution The Analo ...

  • Baldor MN754 - page 10

    2‐2 Description T able 2‐1 Characteristics High Resolution Inputs Number of Inputs Tw o Input Signal Levels +5VDC, +10VDC, 0-20 mA or 4-20mA Maximum Digital Resolution 16 bits High Resolution Outputs Number of Outputs Tw o Output Signal Levels 0-5VDC, +5VDC, 0-10VDC, +10VDC, 0-20 mA or 4-20mA Maximum Digital Resolution 16 bits T able 2‐2 Sign ...

  • Baldor MN754 - page 11

    Section 3 Installation Installation 3‐1 Caution: Before you proceed, be sure to read and become familiar with the safety precautions at the beginning of this manual. If you have any questions, seek expert advise before you proceed. Do not proceed if you are unsure of the safety precautions or any procedure. This section describes the expansion bo ...

  • Baldor MN754 - page 12

    3‐2 Installation 3. Be sure drive operation is terminated and secured. 4. Remove all power sources from the control. 5. W ait at least 5 minutes for internal capacitors to discharge. 6. Refer to the control manual and remove the enclosure cover . 7. Open the control cover and locate Slots 1 & 2, see Figure 3‐1. Note: Slot 3 is reserved for ...

  • Baldor MN754 - page 13

    Installation 3‐3 Jumper Definitions The settings for jumpers J2 to J5 are shown in Figure 3‐2. Figure 3‐2 Jumper and T erminal Locations (T op V iew) 1 Chassis Ground 2 Analog Input 1 (+) 3 Analog Input 1 (-) 4 Analog Input 2 (+) 5 Analog Input 2 (-) 6 Analog Ground 7 Analog Ground 8 Analog 1 Output 9 Analog 2 Output 10 Chassis Ground 1 1 Not ...

  • Baldor MN754 - page 14

    3‐4 Installation Figure 3‐3 High Resolution Input Connections Analog to Digital Converter EXBHH005AXX Control Board Micro Processor Analog Input1 Analog Input2 2 3 1 5 4 - + - + T erminal tightening torque is 2 lb‐in (0.24 Nm) maximum. Figure 3‐4 High Resolution Output Connections Digital to Analog Converter EXBHH005AXX Control Board Micro ...

  • Baldor MN754 - page 15

    Section 4 Software Setup Setup 4‐1 Overview Programming setup is accomplished using the keypad of the control. General programming steps are defined in the appropriate control manual. T o install the expansion board see Section 3 of this manual. 1. Install EXBHH005 expansion board. If the board is in Slot 1 , the OP1 inputs and outputs are used. ...

  • Baldor MN754 - page 16

    4‐2 Setup Hi RES Parameters Level 1, Input Setup Block Parameter P# Adjustable Range Factory User Setting COMMAND SOURCE 1402 3-KEYP AD 4-NETWORK 5- Opt1 Ana In1 6- Opt1 Ana In2 7- Opt2 Ana In1 8- Opt2 Ana In2 9-EXB PULSE FOLL 1 OP1 ANA IN1 TYPE 1451 0-None, 1-(-10V to+10V), 2-(-5V to+5V), 3-(4to20mA), 4-(0to20mA) 1 OP1 ANA IN1 Invert 1452 0-OFF ...

  • Baldor MN754 - page 17

    Setup 4‐3 Hi RES Parameters Continued Level 1, Input Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP2 ANA IN1 TYPE 1463 0-None, 1-(-10V to+10V), 2-(-5V to+5V), 3-(4to20mA), 4-(0to20mA) 1 OP2 ANA IN1 Invert 1464 0-OFF , 1-ON 0 OP2 ANA IN1 Gain 1465 0.0% TO 300.0% 100.0 OP2 ANA IN1 Offset 1466 -100.0% TO 100.0% 0.0 OP2 A ...

  • Baldor MN754 - page 18

    4‐4 Setup Hi RES Parameters Continued Level 1, Output Setup Block Parameter P# Adjustable Range Factory User Set‐ ting ANA OUT1 Signal 151 1 18-CONTROL TEMP 19-ANALOG INPUT1 20-ANALOG INPUT2 21- OPT1 ANA IN1 22- OPT1 ANA IN2 23- OPT2 ANA IN1 24- OPT2 ANA IN2 29 ANA OUT2 Signal 1514 18-CONTROL TEMP 19-ANALOG INPUT1 20-ANALOG INPUT2 21- OPT1 ANA ...

  • Baldor MN754 - page 19

    Setup 4‐5 Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP1 ANAOUT1 Signal 1552 0-SPEED REF 1-SPEED DEMAND 2-ACC/DEC 3-MOT OR CURRENT 4-MAG CURRENT 5-MAG CURRENT COMMAND 6-LOAD CURRENT 7-LOAD CURRENT COMMAND 8-POWER 9-PH1 CURRENT 10-PH2 CURRENT 1 1-PH3 CURRENT 12-MOT OR VOL T ...

  • Baldor MN754 - page 20

    4‐6 Setup Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Set‐ ting OP2 ANAOUT1 T ype 1557 0-(0V to+10V), 1-(0V to+5V), 2-(-10V to+10V), 3-(-5V to+5V), 4-(4to20mA), 5-(0to20mA) 2 OP2 ANAOUT2 T ype 1560 2 OP2 ANAOUT1 Gain 1559 0 ‐ 200.0% 100.0 OP2 ANAOUT2 Gain 1562 100.0 ...

  • Baldor MN754 - page 21

    Setup 4‐7 Hi RES Parameters Continued Level 1, Output Setup Block Continued Parameter P# Adjustable Range Factory User Setting OP2 ANAOUT1 Signal 1558 0-SPEED REF 1-SPEED DEMAND 2-ACC/DEC 3-MOT OR CURRENT 4-MAG CURRENT 5-MAG CURRENT COMMAND 6-LOAD CURRENT 7-LOAD CURRENT COMMAND 8-POWER 9-PH1 CURRENT 10-PH2 CURRENT 1 1-PH3 CURRENT 12-MOT OR VOL T ...

  • Baldor MN754 - page 22

    4‐8 Setup Hi RES Parameters Continued Level 2, Miscellaneous Block Parameter P# Adjustable Range Factory User Setting Filter Source 2310 4-Analog IN2, 5-Opt1 ANA1, 6-Opt1 ANA2, 7-Opt2 ANA1, 8-Opt2 ANA2 0 Level 2, Process Control Block Continued Parameter P# Adjustable Range Factory User Setting Process Feedback 2603 5-Network, 6-Opt1 ANA1, 7-Opt1 ...

  • Baldor MN754 - page 23

    Section 5 T roubleshooting T roubleshooting 5‐1 Overview The Main Menu “Diagnostic” option is used to view the diagnostic screen. Diagnostic Screen At the keypad, from the Main menu the Diagnostic screens are accessed and the Option Boards display shows what boards are installed and recognized by the software. If the installed board is not di ...

  • Baldor MN754 - page 24

    5‐2 T roubleshooting ...

  • Baldor MN754 - page 25

    Baldor District Offices ...

  • Baldor MN754 - page 26

    E 2005 Baldor Electric Printed in USA 2/06 MN754 BALDOR ELECTRIC COMP ANY World Headquarters P .O. Box 2400 Fort Smith, AR 72901-2400 (479) 646-471 1 Fax (479) 648-5792 www .baldor .com ...

メーカー Baldor カテゴリー Music Mixer

Baldor MN754のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MN754の取扱説明書
- Baldorの製品カード
- パンフレット
- またはBaldor MN754の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Baldor MN754の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Baldor MN754の取り付け説明書、サービスマニュアル、簡易説明書、またはBaldor MN754のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Baldor MN754の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Baldor MN754デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBaldor MN754を使用するのを助ける技術的文書のことです。説明書は通常、全てのBaldor MN754ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Baldorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Baldor MN754の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBaldor MN754の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Baldor MN754に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Baldor MN754デバイスの基本機能を使うにあたってのヒント。 Baldor MN754のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Baldor MN754に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBaldor MN754のメーカー/サービスへの連絡先に関する情報。

Baldor MN754についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBaldor MN754の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBaldor MN754で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)