    OWNERS MANUAL INST ALLA TION AND OPERA TING INSTRUCTIONS REP AIR P ARTS LIST Self Prime Frame Mounted Centrifugal Pump Dir ect Coupling Drive/ Belt Driven/Hydraulic Drive B4ZRKS B3TRKS B2XRKS B2ZRKL IMPORT ANT For best possible performance and continuous, satisfactory operation, read these instructions before installing your new pump. Should servic ...

  • Berkley B2XRKS - page 2

    Page 2 F00633 General Information Safety First Pump Location READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: warns about hazards that will cause serious personal injury, death o ...

  • Berkley B2XRKS - page 3

    F00633 Page 3 General Information Installation FOUNDA TION: Refer to illustration on Page 4. Heavy weights; risk of bodily harm due to crushing. Use care and proper lifting equipment when handling pump for installation. Size and weight of some units will require hoists for safe handling. Pump should be set on a concrete foundation which is sufficie ...

  • Berkley B2XRKS - page 4

    Page 4 F00633 Pump Foundation Installation T ypical Installations Drainage Drainage Pump or Motor Frame 1/2" or thicker Sole Plate tapped for hold down bolts Anchor Bolts Pump or Motor Frame Shims for alignment Anchor Bolt Steel Channel Concrete Foundation Grout Dam Drainage Wedges Various Heights Concrete Foundation Shims Pump and Motor Base ...

  • Berkley B2XRKS - page 5

    F00633 Page 5 Centerline 2112 1095 Caliper Straight Edge "B" Parallel "A" Angular Table I Distance from Centerline Maximum Allowable T.I.R. 4.00 inches 3.00 inches 2.00 inches 1.00 inch 0.035 inches 0.070 inches 0.105 inches 0.140 inches Rotating shaft can catch and trap clothing or body. Coupling guard must ALWAYS be in place w ...

  • Berkley B2XRKS - page 6

    Page 6 F00633 ALIGNMENT Drive belt can catch and trap clothing or body. Belt guard must ALWAYS be in place when pump is running. Belt guard is not shown for pictorial clarity. • Drive and pump shaft centerlines (A) must be parallel as shown. Belt centerlines (B) must be straight as shown. • When installing belts, move the driver toward the pump ...

  • Berkley B2XRKS - page 7

    F00633 Page 7 Electric Motor / Hydraulic Motor Installation Mounting Hydraulic Motor and Adapter Installation 2116 1195 AMP TIME Incoming Power L1 L2 L3 AUTO OFF HAND START NEMA 3R Enclosure 4 5 3 2 1 Protect Your Investment pp g p prior to installation. 1. Contactor 2. Lightning Arrestor 3. Loss of Prime Protection 4. Fuseable Disconnect 5. Starte ...

  • Berkley B2XRKS - page 8

    Page 8 F00633 Suction Connection Installation Suction Lift Short length of straight pipe after reducer. ( 2 times pipe diameter minimum ) Suction Gauge Straight run, short as possible but at least 6 times pipe diameter ("D") after elbow to stabilize flow. As close as possible Pipe diameter ("D") 4 x "D" minimum 1 x &qu ...

  • Berkley B2XRKS - page 9

    F00633 Page 9 Suction Connection Installation Suction Lift Do not use Concentric Reducer. Concentric Reducer causes high spots along the suction line resulting in air pockets. Do not install valves in suction line. Long run not recommended Unsupported pipe causes excessive stress on pump and fittings. Excess use of pipe fittings means potential air ...

  • Berkley B2XRKS - page 10

    Page 10 F00633 Suction Connection Installation When Flooded Suction Exists Recommended See foundation section. Pump driven by remote power source, direct coupling or pulley/belt connection. 2214 0196 Water under pressure Support pipe as required Short run of straight pipe after reducer (2 times pipe diameter). Eccentric Reducer flat side up. Isolat ...

  • Berkley B2XRKS - page 11

    F00633 Page 11 Suction Connection Installation When Flooded Suction Exists Not Recommended 2215 0196 Water under pressure Inverted Eccentric Reducer may result in air pocket. Do not leave valve partially closed. Check Valve in suction pipe not needed. Unsupported pipe causes excessive stress on pump and fittings. Concentric Reducer may cause air po ...

  • Berkley B2XRKS - page 12

    Page 12 F00633 Discharge Connection Installation Use Concentric Reducer to mimimize friction losses. Isolation Valve Support piping as required Non-Slam or spring loaded check valve. Isolation valve to permit servicing of check valve or pump. Align piping to minimize flange stress. Pressure Gauge Discharge pipe diameter at least one nominal pipe si ...

  • Berkley B2XRKS - page 13

    F00633 Page 13 Discharge Connection Installation Do not use Gate Valve to throttle flow. Avoid abrupt change in pipe size. Avoid undersized pipe diameter. Do not force alignment that can cause flange stresses. Do not leave pipe unsupported. Avoid check valves that may cause hydraulic shock. 2119 1195 Not Recommended • Avoid excess friction loss c ...

  • Berkley B2XRKS - page 14

    Page 14 F00633 CHECK ROT A TION: Before pump is put into operation, rotational direction must be checked to assure proper performance of pump. Refer to illustration below to varify proper rotational direction for each model covered in this manual. Hazardous voltage. Can shock, burn, or cause death. Disconnect power to pump before servicing. Do not ...

  • Berkley B2XRKS - page 15

    F00633 Page 15 LUBRICA TION: LIQUID END of pump requires no lubrication. Wear rings, packing rings, and models using a mechanical shaft seal, are lubricated by the liquid being pumped. Do not run dry! BEARING FRAME - add approximately 2 ounces of a lithium-based NGLI No. 2 extra pressure ball bearing grease to each bearing during quarterly inspecti ...

  • Berkley B2XRKS - page 16

    Page 16 F00633 Packing Ring Replacement Maintenance Removal Packing Hooks Packing Ring Shaft 2239 0196 Packing Gland 1 2 x Scale 2 • Unfasten hardware holding Packing Gland in place and slide back on shaft to expose packing rings. • Remove packing rings from Stuffing box using two commercially available Packing Hooks as shown. • Slide Lantern ...

  • Berkley B2XRKS - page 17

    ROUTINE MAINTENANCE A well maintained pumping system will extend the life of the unit and will require fewer repairs. This means less down time which can be very critical when a constant delivery of water is required. A routine maintenance and inspection schedule should be set up on a weekly, quarterly, and annual basis with records kept of these a ...

  • Berkley B2XRKS - page 18

    Page 18 F00633 General Information Pump Nomenclature ORDERING REPLACEMENT P ARTS: Locate the Berkeley nameplate on the pump, plate is normally on the bearing bracket. Information found on this plate is shown below. To be sure of receiving correct parts, provide all nameplate data when ordering. The BM (Bill of Material) number is most important. Wr ...

  • Berkley B2XRKS - page 19

    F00633 Page 19 Parts Breakdown Self Prime Bearing Frame Pump Nomenclature 2135N 1195 Bearing Frame Shaft Case Gasket Pump Case (Volute) Impeller Impeller Washer Impeller Screw Suction Flange (Check Valve) Suction Flange Gasket Clamp Washer Rubber Clack Lantern Ring Shaft Sleeve Packing Ring Assembly Packing Gland Inner ...

  • Berkley B2XRKS - page 20

    Page 20 F00633 Tr oubleshooting Maintenance Electrical Drive Pumps CAUSE CORRECTIVE ACTION I. ELECTRICAL A. No voltage in power system Check phase-to-phase on line side of starter contactor. Check circuit breaker or fuses. B. No voltage on one phase Check phase voltage on line side of starter contactor. Isolate open circuit (Three Phase Units) (cir ...

  • Berkley B2XRKS - page 21

    F00633 Page 21 Tr oubleshooting Maintenance Engine Drive Pumps CAUSE CORRECTIVE ACTION I. ENGINE A. Speed too low Refer to engine manufacturer’s manual. B. Rotating and/or Refer to engine manufacturer’s manual. reciprocating parts drag C. Speed too high Refer to pump and engine power curves. Adjust. D. Loose or broken parts Refer to engine manu ...

  • Berkley B2XRKS - page 22

    Page 22 F00633 I. QUARTERL Y INSPECTION Inspect all system piping connections for leakage or possible misalignment. Check pump foundation for soundness and see that all hold-down bolts are secure. Complete any lubrication requirements as dictated by pump and driver owner’s manual. Inspect packing or mechanical seal for possible replacement. Exami ...

  • Berkley B2XRKS - page 23

    F00633 Page 23 Notes Maintenance ...

  • Berkley B2XRKS - page 24

    Page 24 F00633 Wa rranty Berkeley Berkeley/Wicor Canada, Inc. (“Wicor”) warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship. If within twelve (12) months from the date of installation or twenty-four (24) months from the date of manufacture any such product shal ...

メーカー Berkley カテゴリー Water Pump

Berkley B2XRKSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- B2XRKSの取扱説明書
- Berkleyの製品カード
- パンフレット
- またはBerkley B2XRKSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Berkley B2XRKSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Berkley B2XRKSの取り付け説明書、サービスマニュアル、簡易説明書、またはBerkley B2XRKSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Berkley B2XRKSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Berkley B2XRKSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBerkley B2XRKSを使用するのを助ける技術的文書のことです。説明書は通常、全てのBerkley B2XRKSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Berkleyの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Berkley B2XRKSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBerkley B2XRKSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Berkley B2XRKSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Berkley B2XRKSデバイスの基本機能を使うにあたってのヒント。 Berkley B2XRKSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Berkley B2XRKSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBerkley B2XRKSのメーカー/サービスへの連絡先に関する情報。

Berkley B2XRKSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBerkley B2XRKSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBerkley B2XRKSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)