    TECHNICAL GUIDE SPLIT -SYSTEM A IR CONDITIONERS 13 SEER – R-22 MODELS: H*RD018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) H*RD036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) Due to continuous produc t impr ovement, specifications are subject to change without notice. V isit us on th e web at www .york.com A dditional rating informa tion can be f ...

  • York H*RD036 THRU 060 - page 2

    254892-YTG-C-0606 2 Unitary Products Group All dimensions are in inches. They a re subject to change without notice. Ce rtif ied dimensio ns will be provide d upon request. PHYSICAL AND ELECTRICAL DA T A - 1 PHASE MODEL H2RD018S06 H2RD024S06 H2RD030S06 H 2RD036S06 H2RD042S06 H2RD048S06 H 2RD060S06 Unit Supply V olt age 208-230V , 1 φ, 60Hz Normal ...

  • York H*RD036 THRU 060 - page 3

    254892-YTG-C-0606 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for V arious Ma tched Systems - 1 Phase Outdoor Unit H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06 Required TXV 1 TVM2A1 1 TVM2(A,B)1 1 TVM2A1 1 TVM2A1 1 TVM2C1 1 TVM2C1 1 TVM2C1 Factory R-22 Charge, lbs-oz 4 - 9 6 - 3 5 - 13 6 - 0 8 - 13 ...

  • York H*RD036 THRU 060 - page 4

    254892-YTG-C-0606 4 Unitary Products Group H C 1 8 A 3 X 0 2 B + 1 ––––– H C 3 0 A 3 X – 2 A + 0 0 –––– HC36B3X – – 0 0 – – – H C 4 2 C 3 X ––––0 0 – H C 6 0 C 3 X –––––0 0 H D 2 4 A 3 X 0 2 A + 0 ––––– HD36B3X – – 0 0 – – – H D 4 8 C 3 X ––––0 0 – H D 6 0 D 3 X ––? ...

  • York H*RD036 THRU 060 - page 5

    254892-YTG-C-0606 Unitary Products Group 5 PROCEDURES: 1. U nit factory charge listed on the unit nameplate includes refr igerant for the condenser , the smallest evaporator and for 15 feet of inter- connecting line tubing. 2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table. 3. Addition ...

  • York H*RD036 THRU 060 - page 6

    254892-YTG-C-0606 6 Unitary Products Group All dimensions are in inches. They a re subject to change without notice. Ce rtif ied dimensio ns will be provide d upon request. PHYSICAL AND ELECTRICAL DA T A - 3 PHASE MODEL H1RD 030S25 H1RD 036S25 H1RD 042S25 H1RD 048S25 H1RD 060S25 H1RD 030S46 H1RD 036S46 H1RD 042S46 H1RD 048S46 H1RD 060S46 Unit Suppl ...

  • York H*RD036 THRU 060 - page 7

    254892-YTG-C-0606 Unitary Products Group 7 Additional R-22 Charge / Orifice Size for V arious Ma tched Systems - 3 Phase Outdoor Unit H1RD030S(25,46) H1RD036S(25,46) H1RD042S(25,46) H1RD048S(25, 46) H1RD060S(25,46) Required TXV 1 TVM2A1 1 TVM2A1 1 TVM2C1 1 TVM2C1 1 TVM2C1 Factory R-22 Charge, lbs-oz 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 Indoor Coil 1 Ad ...

  • York H*RD036 THRU 060 - page 8

    254892-YTG-C-0606 8 Unitary Products Group PROCEDURES: 1. U nit factory charge listed on the unit nameplate include s refr iger ant for the condenser , the smallest evaporator and for 15 feet of inter- connecting line tubing. 2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table. 3. Additi ...

  • York H*RD036 THRU 060 - page 9

    254892-YTG-C-0606 Unitary Products Group 9 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 & 3 PH 13 SEER AC WITH MA H2RD018S06 MA08B 2,5,8 17 FC/MC18B 600 17.5 1 1.7 13.00 1 1.00 MA08B 2,5,8 17 G*FD024H17 600 17.5 1 1.7 13.00 1 1.00 H2 ...

  • York H*RD036 THRU 060 - page 10

    254892-YTG-C-0606 10 Unitary Products Group — = Not applicable. 1 PH 13 SEER AC WITH A V / SV - V ARIABLE SPEED H2RD018S06 A V24 2,5,8,10,15 17 – 600 18.0 1 1.7 14.00 1 1.50 H2RD024S06 A V24 2,5,8,10,15 17 – 800 23.2 16.5 14.00 1 1.50 H2RD030S06 A V36 5,8,10,15,18 21 – 1000 30.0 21.2 14.00 1 1.50 H2RD036S06 A V36 5,8,10,15,18 21 – 1200 35 ...

  • York H*RD036 THRU 060 - page 11

    254892-YTG-C-0606 Unitary Products Group 11 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL F URNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. H2RD018S06 450 750 14,17 FC/MC/PC/UC18 600 17.5 1 1.7 13.00 1 1.00 14,17 FC/MC/PC/UC24 600 17.7 1 1.9 13.00 1 1.00 14 G*F ...

  • York H*RD036 THRU 060 - page 12

    254892-YTG-C-0606 12 Unitary Products Group H2RD042S06 1200 1600 17,21 FC/MC/PC/UC42 1400 40.5 29.6 13.00 1 1.00 21,24 FC/MC/PC/UC48 1400 41.0 30.2 13.00 1 1.00 17 G*F A042S17 1400 40.5 29.6 13.00 1 1.00 21 G*F A048S21 1400 41.0 29.6 13.00 1 1.00 21 G*FD042H21 1400 40.5 29.6 13.00 1 1.00 17 G*FD046H17 1400 40.5 29.6 13.00 1 1.00 21,24 G*FD048H21,24 ...

  • York H*RD036 THRU 060 - page 13

    254892-YTG-C-0606 Unitary Products Group 13 COOLING CAP ACITY - With V ariable Speed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 H2RD018S06 PV8*A12 FC/MC/PC18A 14 600 17.8 1 1.9 14 .00 1 1.50 PV9*A12 FC/MC/PC18A 14 600 17.8 1 1.8 14 ...

  • York H*RD036 THRU 060 - page 14

    254892-YTG-C-0606 14 Unitary Products Group H2RD036S06 PV8*A12 FC/MC/PC36A 14 1200 35.0 25.4 13.00 1 1.00 PV8*B16 FC/MC/PC36B 17 1200 35.2 25.6 13.75 1 1.00 PV8*C16 FC/MC/PC36C 21 1200 35.2 25.6 14.00 1 1.50 PV8*C20 FC/MC/PC36C 21 1200 35.2 25.6 14.00 1 1.50 PV9*A12 FC/MC/PC36A 14 1200 34.8 25.4 13.00 1 1.00 P(C,V)9*B12 FC/MC/PC36B 17 1200 35.0 25. ...

  • York H*RD036 THRU 060 - page 15

    254892-YTG-C-0606 Unitary Products Group 15 H2RD048S06 PV8*C16 FC/MC/PC48C 21 1500 46.5 34.2 13.00 1 1.00 PV8*C20 FC/MC/PC48C 21 1600 47.0 35.2 13.00 1 1.00 P(C,V)9*C16 FC/MC/PC48C 21 1600 47.0 35.2 13.00 1 1.00 P(C,V)9*C20 FC/MC/PC48C 21 1600 47.0 35.2 13.00 1 1.00 P(C,V)9*D20 FC/MC/PC48D 24 1600 47.0 35.2 13.25 1 1.00 PV8*C16 HC48 21 1500 46.5 33 ...

  • York H*RD036 THRU 060 - page 16

    254892-YTG-C-0606 16 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. HARD ST ART KIT - Provides increased starting torque for areas with low voltage. COMPRESSOR BLANKET - Designed to furth er reduce the normal compressor operating sound. Refer to price pages for specific match-ups. OFF CYCLE TIMER DELA Y - Provi ...

  • York H*RD036 THRU 060 - page 17

    254892-YTG-C-0606 Unitary Products Group 17 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York H*RD036 THRU 060 - page 18

    254892-YTG-C-0606 18 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree ...

  • York H*RD036 THRU 060 - page 19

    254892-YTG-C-0606 Unitary Products Group 19 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York H*RD036 THRU 060 - page 20

    254892-YTG-C-0606 20 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree ...

  • York H*RD036 THRU 060 - page 21

    254892-YTG-C-0606 Unitary Products Group 21 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York H*RD036 THRU 060 - page 22

    254892-YTG-C-0606 22 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree ...

  • York H*RD036 THRU 060 - page 23

    254892-YTG-C-0606 Unitary Products Group 23 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York H*RD036 THRU 060 - page 24

    Subject to change without notice. Printe d in U .S.A. 254892-YTG-C-0606 Copyright © by York International Corp. 2006. All right s reserved. Supersedes: 254892 / 036-21339-002 Rev. B (020 6) Unitary 5005 Norman Product s Y ork O K Group Drive 73069 NOTES ...

メーカー York カテゴリー Air Conditioner

York H*RD036 THRU 060のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- H*RD036 THRU 060の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork H*RD036 THRU 060の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York H*RD036 THRU 060の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York H*RD036 THRU 060の取り付け説明書、サービスマニュアル、簡易説明書、またはYork H*RD036 THRU 060のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York H*RD036 THRU 060の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York H*RD036 THRU 060デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork H*RD036 THRU 060を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork H*RD036 THRU 060ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York H*RD036 THRU 060の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork H*RD036 THRU 060の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York H*RD036 THRU 060に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York H*RD036 THRU 060デバイスの基本機能を使うにあたってのヒント。 York H*RD036 THRU 060のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York H*RD036 THRU 060に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork H*RD036 THRU 060のメーカー/サービスへの連絡先に関する情報。

York H*RD036 THRU 060についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork H*RD036 THRU 060の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork H*RD036 THRU 060で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)