Lennox International Inc. MONTESTの取扱説明書

24ページ 1.58 mb
ダウンロード

ページに移動 of 24

Summary
  • Lennox International Inc. MONTEST - page 1

    EP A Wood-Burning Fireplace P/ N 85 0,0 38 M RE V . C 0 4/ 200 7 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or i ...

  • Lennox International Inc. MONTEST - page 2

    W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flamma ...

  • Lennox International Inc. MONTEST - page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Mo nt ec it o Es ta te ......... Page 3 Fuel ............................................ ...

  • Lennox International Inc. MONTEST - page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air-boost system register is located underneath the door handles. Placed in the f ...

  • Lennox International Inc. MONTEST - page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fire to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELIN ...

  • Lennox International Inc. MONTEST - page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times. C. Do not burn coal. The sulp ...

  • Lennox International Inc. MONTEST - page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door , to the female part, which is on the fireplace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factory ...

  • Lennox International Inc. MONTEST - page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the locatio ...

  • Lennox International Inc. MONTEST - page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Ro of Sup po rt Storm Collar Flashing Dr yw al l or An y Ri gi d Ma te ri al 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Insulate Joists Same As Ceiling Draft Stops Firestop CTDT T ermination Note: Non- Combustible Cha ...

  • Lennox International Inc. MONTEST - page 10

    1. Com bustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 13 ) . MANTEL & F ACING The mantel ...

  • Lennox International Inc. MONTEST - page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield No n- Com bust ibl e Fl am epr oof Fa ci ng 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insula ...

  • Lennox International Inc. MONTEST - page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: - Outside air kit (includes 40 inch flex that goes up to ten (10) feet long) - 4” Adaptor for fireplace connection Outside Air Installation The outside air assembly may be i ...

  • Lennox International Inc. MONTEST - page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or a ...

  • Lennox International Inc. MONTEST - page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. Fro m belo w , inst all a firest op in e ...

  • Lennox International Inc. MONTEST - page 15

    Roof Down Slope Hole Size D EG R E E O F S L O P E S ec u r e T e m p ™ S 21 0 0 + N ov a T e m p ™ HT 6 0 00 + S ec u r e T e m p GX A CB I R oo f Pi t c h 7 ” 7 ” 0 * 1 5” ( 38 0 mm ) 1 5” ( 38 0 mm ) 2 /1 2 1 5- 3 / 8” ( 39 0 m m) 1 5- 3 / 8” ( 39 0 m m) 4 /1 2 1 6- 1 / 8” ( 41 0 m m) 1 6- 1 / 8” ( 41 0 m m) 6 /1 2 1 6- 7 / 8 ...

  • Lennox International Inc. MONTEST - page 16

    OFFSET CHIMNEY INST ALLA TION The minimum chimney height when using elbows is: C h i m n ey Elbow Offset & Height T wo Lengths Between Elbows 8” 12” 18” 24” 36” 8” & 36” 1 2” & 36 ” 1 8” & 3 6 ” 2 4” & 3 6 ” 36” & 36” GX S2 10 0+ HT 60 00 + 7” 15º A 3” (7 6 m m) 4- 1/4 ” (1 08 mm) 5- 3/4 ...

  • Lennox International Inc. MONTEST - page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR ...

  • Lennox International Inc. MONTEST - page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), ...

  • Lennox International Inc. MONTEST - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre ...

  • Lennox International Inc. MONTEST - page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24 ...

  • Lennox International Inc. MONTEST - page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC C h im ne y i s NO T re co m me nd e d at e le va ti o ns a bo ve 4 ,0 0 0 fe e t or i n co ld c li ma te s ( cl im at es w he re t em p er at u re s w il l fa ll b el ow 3 2° F / 0 ° C) . Description Cat./Part No. One of the following adaptors is required if installing an AC chimney syst ...

  • Lennox International Inc. MONTEST - page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fill th ...

  • Lennox International Inc. MONTEST - page 23

    NOTES 23 ...

  • Lennox International Inc. MONTEST - page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . C 04/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Lennox Hearth Products 11 ...

メーカー Lennox International Inc. カテゴリー Stove

Lennox International Inc. MONTESTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MONTESTの取扱説明書
- Lennox International Inc.の製品カード
- パンフレット
- またはLennox International Inc. MONTESTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lennox International Inc. MONTESTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lennox International Inc. MONTESTの取り付け説明書、サービスマニュアル、簡易説明書、またはLennox International Inc. MONTESTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lennox International Inc. MONTESTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lennox International Inc. MONTESTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLennox International Inc. MONTESTを使用するのを助ける技術的文書のことです。説明書は通常、全てのLennox International Inc. MONTESTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lennox International Inc.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lennox International Inc. MONTESTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLennox International Inc. MONTESTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lennox International Inc. MONTESTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lennox International Inc. MONTESTデバイスの基本機能を使うにあたってのヒント。 Lennox International Inc. MONTESTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lennox International Inc. MONTESTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLennox International Inc. MONTESTのメーカー/サービスへの連絡先に関する情報。

Lennox International Inc. MONTESTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLennox International Inc. MONTESTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLennox International Inc. MONTESTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)