UNICOM Electric FEP-30109T-C-SMの取扱説明書

22ページ 1.39 mb
ダウンロード

ページに移動 of 22

Summary
  • UNICOM Electric FEP-30109T-C-SM - page 1

    908 Canada Court City of Industry , C A 91748 U.S.A. Phone: 626.964.7873 or 800.346.6668 F ax: 626.964.7880 www .unicomlink.com e-mail: info@unicomlink.com ©UNICOM 2005. UNICOM and “A Network Systems Solution” ar e trademarks of UNICOM Electric, Inc. All rights reserved. Specifications subject to change without notice. Rev: 09.05 8 Port 10/ 10 ...

  • UNICOM Electric FEP-30109T-C-SM - page 2

    Smart-Switch/801 1 Features  Conforms to IEEE 802.3, 802.3u, and 802.3x Ethernet Standards  Eight auto-sensing 10/100Mbps Ethernet RJ-45 ports  Automatic MDI/MDIX crossover for each 10/100Base-TX port  One Fixed 100Mbps Fiber port (SC/ST-Multi-Mode, SC-Single Mode)  Back-Pressure-Base flow control on Half-duplex mode  Pause-Frame- ...

  • UNICOM Electric FEP-30109T-C-SM - page 3

    Smart-Switch/801 2 Package Contents Unpack the contents of the Smart-Switch/801 and verify them against the checklist below.  Smart-Switch/801 Fast Ethernet Switch  Power Cord  Four Rubber Feet  RS-232 console management cable  User Guide Smart-Switch/801 Power Cord Rubber Feet RS-232 cable User Guide Figure 1-2. Package Contents If ...

  • UNICOM Electric FEP-30109T-C-SM - page 4

    Smart-Switch/801 3 Hardware Description This section describes the hardware of the Smart-Switch/801. The physical dimensions of the Smart-Switch/801 are 250mm x 132mm x 37mm (L x W x H) Front Panel The Front Panel of the Smart-Switch/801 consists of eight auto-sensing 10/100Mbps Ethernet RJ-45 ports with automatic MDI/MDIX, one 100Base- FX fiber po ...

  • UNICOM Electric FEP-30109T-C-SM - page 5

    Smart-Switch/801 4 LED Indicators Figure 2-4. LED Indicators There are three LED Indicators (10/100M, LNK/ACT, FDX/COL) for each UTP port and two LED Indicators (LNK/ACT, FDX/COL) for the fiber port. The following table provides descriptions of the LED status. They provide a real-time indication of systematic operation. UTP Ports LED Status Color D ...

  • UNICOM Electric FEP-30109T-C-SM - page 6

    Smart-Switch/801 5 Fiber Port LED Status Color Description On Green The port is successfully connecting with the device. Blinks Green The port is receiving or transmitting data. LK /ACT Off No device attached. On Orange The port is operating in Full-duplex mode. Blinks Orange Collision of Packets occurring within the port. FDX /COL Off The port is ...

  • UNICOM Electric FEP-30109T-C-SM - page 7

    Smart-Switch/801 6 Rear Panel The Console port and 3-pronged power plugs are located at the Rear Panel of the Smart -Switch/801 as shown in Figure 2-8. This Switch will work with AC in the 100-240V AC, 50-60Hz. Range. Figure 2-5 The Rear Panel of the Smart-Switch/801 Console Port: Configuration is done through the console port connector. This requi ...

  • UNICOM Electric FEP-30109T-C-SM - page 8

    Smart-Switch/801 7 Attaching Rubber Feet A _ Make sure mounting surface on the bottom of the Switch is grease and dust free. B _ Remove adhesive backing from the Rubber Feet. C _ Apply the Rubber Feet to each corner on the bottom of the Switch. These footpads protect the Switch from shock and vibration. Figure 2-6. Attaching Rubber Feet to each cor ...

  • UNICOM Electric FEP-30109T-C-SM - page 9

    Smart-Switch/801 8 Network Application This section provides a few samples of network topology in which the Switch is used. Desktop Application The Smart-Switch/801 can be used as a desktop switch, an ideal solution for a small workgroup. Used as a standalone switch, personal computers, servers, and printer servers are directly connected to form a ...

  • UNICOM Electric FEP-30109T-C-SM - page 10

    Smart-Switch/801 9 Segment Application For enterprise networks where large data broadcast are constantly processed, this switch is ideal for connecting workgroups or departments to the corporate backbone. Figure 3-2. Segment Applications Connect PCs, workstations, and servers to each other by connecting these devices directly to the Smart-Switch/80 ...

  • UNICOM Electric FEP-30109T-C-SM - page 11

    Smart-Switch/801 10 Smart-Switch/801 PRINTER COMPUTER SERVER COMPUTER Smart-Switch/801 Fiber Optic Connection (2km - MM) (30km - SM) 200Mbps Figure 3-3. Use fiber port (Smart-Switch/801) to extend the distance between workgroups In the above illustration, two Smart-Switch/801 switches are used to connect two small workgroups. By using fiber ports t ...

  • UNICOM Electric FEP-30109T-C-SM - page 12

    Smart-Switch/801 11 Network Configuration This Section explains how to configure VLAN features via a direct connection to the console port on the rear panel of the Smart-Switch/801. This port is a female DB-9 connector. From the main menu of the console program, the user can configure various functions of the switch. Connecting a Terminal or PC to ...

  • UNICOM Electric FEP-30109T-C-SM - page 13

    Smart-Switch/801 12 Baud Rate: 9600 bps Data Bits: 8 Parity: none Stop Bit: 1 Flow Control: None Figure 4-2. The settings of communication parameters After you have finished parameter settings, press “ OK “. The main console management menu should appear. (You need to reboot the Switch to show Main Menu) ...

  • UNICOM Electric FEP-30109T-C-SM - page 14

    Smart-Switch/801 13 Console Management Console Configuration enables use of a local console terminal or PC to control ports and VLANs on the Smart-Switch/801. Main Menu The Main Menu shows all available switch configuration options. Figure 4-3. The Main Menu of Console Management Per Port Setting From the Main Menu, choose the 1 st Item by typing ? ...

  • UNICOM Electric FEP-30109T-C-SM - page 15

    Smart-Switch/801 14 Figure 4-4. The default Per Port Setting Figure 4-5. Port statuses to configure Setting VLAN A VLAN (Virtual LAN) is a group of switch ports designated by the switch as belonging to the same broadcast domain. This feature allows workgroups to be defined on the basis of their logical location instead of their physical location. V ...

  • UNICOM Electric FEP-30109T-C-SM - page 16

    Smart-Switch/801 15 Grouping the switch ports into broadcast domains and assigning them to the same VLAN increases performance and network capacity. Moreover, VLAN groups can be modified at any time to add, remove, or change users without any re-cabling. From the Main Menu, choose the second item “ Setting VLAN “ by typing “ 2 “. Follow the ...

  • UNICOM Electric FEP-30109T-C-SM - page 17

    Smart-Switch/801 16 Figure 4-7. The process of creating VLAN group Continue to configure the other ports with another VLAN group. In the following example, we create three VLAN groups (VLAN 1: Port 4, 5, 6; VLAN 2: Port 1, 2, 3, 4; VLAN 3: Port 4, 7, 8, 9) and the 4 th port may be connected to an MIS member. Restore Factory Setup If you make a mist ...

  • UNICOM Electric FEP-30109T-C-SM - page 18

    Smart-Switch/801 17 Troubleshooting This section helps solve the most common problems on the Smart- Switch/801. Incorrect connections  Faulty or Loose Cables Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. If that does not correct the problem, try a different cable.  Non-standard ca ...

  • UNICOM Electric FEP-30109T-C-SM - page 19

    Smart-Switch/801 18 LED Diagnostic Indicators The Switch status can be easily monitored through panel indicators. If the power indicator does not light when the power cord is plugged in, you may have a problem with AC power outlet or power cord. However, if the Switch powers off once running, Check for loose power connections, power losses, or surg ...

  • UNICOM Electric FEP-30109T-C-SM - page 20

    Smart-Switch/801 19 Technical Specifications Standards Compliance IEEE 802.3 10Base-T Ethernet, IEEE 802.3u 100Base-TX/FX Fast Ethernet IEEE 802.3x Flow Control Protocol CSMA/CD Max Forwarding and Max Filtering Rate 14,880 pps per Ethernet port, 148,800 pps per Fast Ethernet port Packet size 64 ~ 1522 bytes LED Diagnostic Indicators Per Port: (10/1 ...

  • UNICOM Electric FEP-30109T-C-SM - page 21

    Smart-Switch/801 20 ...

  • UNICOM Electric FEP-30109T-C-SM - page 22

    908 Canada Court City of Industry , C A 91748 U.S.A. Phone: 626.964.7873 or 800.346.6668 F ax: 626.964.7880 www .unicomlink.com e-mail: info@unicomlink.com ©UNICOM 2005. UNICOM and “A Network Systems Solution” ar e trademarks of UNICOM Electric, Inc. All rights reserved. Specifications subject to change without notice. Rev: 09.05 8 Port 10/ 10 ...

メーカー UNICOM Electric カテゴリー Switch

UNICOM Electric FEP-30109T-C-SMのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FEP-30109T-C-SMの取扱説明書
- UNICOM Electricの製品カード
- パンフレット
- またはUNICOM Electric FEP-30109T-C-SMの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、UNICOM Electric FEP-30109T-C-SMの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、UNICOM Electric FEP-30109T-C-SMの取り付け説明書、サービスマニュアル、簡易説明書、またはUNICOM Electric FEP-30109T-C-SMのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、UNICOM Electric FEP-30109T-C-SMの製品を使用するにあたって最も人気のある説明書を閲覧できます。

UNICOM Electric FEP-30109T-C-SMデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUNICOM Electric FEP-30109T-C-SMを使用するのを助ける技術的文書のことです。説明書は通常、全てのUNICOM Electric FEP-30109T-C-SMユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

UNICOM Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. UNICOM Electric FEP-30109T-C-SMの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUNICOM Electric FEP-30109T-C-SMの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。UNICOM Electric FEP-30109T-C-SMに関してこのドキュメントで見つけることができる全てのヒントの目次
3. UNICOM Electric FEP-30109T-C-SMデバイスの基本機能を使うにあたってのヒント。 UNICOM Electric FEP-30109T-C-SMのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。UNICOM Electric FEP-30109T-C-SMに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUNICOM Electric FEP-30109T-C-SMのメーカー/サービスへの連絡先に関する情報。

UNICOM Electric FEP-30109T-C-SMについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUNICOM Electric FEP-30109T-C-SMの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUNICOM Electric FEP-30109T-C-SMで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)