  • Pelco C2622M - page 1

    ® INST ALLA TION FX82051 Unmanaged Ethernet Switch Five 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port C2622M (2/07) ...

  • Pelco C2622M - page 2

    2 C2622M (2/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Overview . . . . . . . . . . . . . . . . . ...

  • Pelco C2622M - page 3

    C2622M (2/0 7) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install n ...

  • Pelco C2622M - page 4

    4 C2622M (2/07) The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NO ...

  • Pelco C2622M - page 5

    C2622M (2/0 7) 5 Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE ...

  • Pelco C2622M - page 6

    6 C2622M (2/07) Product Overview DESCRIPTION The FX82051 unmanaged Ethernet switch provid es five 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the trans port of bidirectional Ethernet data. T wo fi bers are required to transport bidirectional data over th e fiber port. Available in mult imode and single-mode versions, the FX82051 Eth ...

  • Pelco C2622M - page 7

    C2622M (2/0 7) 7 • Designed to meet NEMA TS 2 and Caltrans traff ic signal control equipment standards for ambient operating temperature, mechanical shock and vibrati on, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection NOTE: Conformal coating is required for operati on in environments with relat ...

  • Pelco C2622M - page 8

    8 C2622M (2/07) FRONT PANEL Figure 2 illustrates the front panel of the FX82051 module. Figure 2. Front Panel of FX82051 Module For detailed information about t he front-panel LEDs, refer to T roubleshooting on page 17. ì Reset Button: Restarts the unit î 100BASE-FX Status LED ï Optic Fault LED: Optical signal status/l aser status indicator ñ P ...

  • Pelco C2622M - page 9

    C2622M (2/0 7) 9 REAR PANEL Figure 3 illustrates the rear panel of the FX82051 module. Figure 3. Rear Panel of FX82051 Modul e (SC Fiber Connector Shown) For additional information about r ear -panel connections, refer to Installation on page 10. For detailed information about the RJ-45 LEDs, refer to T roubleshooting on page 17. ì Rack Power/Alar ...

  • Pelco C2622M - page 10

    10 C2622M (2/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82051 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 - 40 x 0.250-inch Phillips pa n head screws with lock wa ...

  • Pelco C2622M - page 11

    C2622M (2/0 7) 11 Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82051 mo dule to automatically negotiate with the device to which the port is connected fo r data rate and duplex modes of operatio ...

  • Pelco C2622M - page 12

    12 C2622M (2/07) Ta b l e A . TX Mode Switch Settings TX Mode Switch Position 10BASE-T/100BASE-TX Modes of Operation 0 Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and 100 Mbps and between half-duplex and full-duplex modes, disable s flow control ( default setting) 1 100 FD/Dis FC: Selects 100 Mbps fu ll-duplex, disables flow control 2 ...

  • Pelco C2622M - page 13

    C2622M (2/0 7) 13 MOUNTING The FX82051 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set t he modes of operation for each 10BASE-T/100BASE-TX port—if r equ ired—befo ...

  • Pelco C2622M - page 14

    14 C2622M (2/07) Mounting the FX82051 Module Using the W all Clip NOTE: Before mounting the FX82051 module to a wall, ens ure that there is adequate space at both ends for viewing the front-panel LEDs and for ma king the various rear- panel cable connections. T o attach the FX82051 module to a wall using the supplied wall clip, refer to Figure 5 an ...

  • Pelco C2622M - page 15

    C2622M (2/0 7) 15 CONNECTIONS Connections to the FX82051 module are made on the rear panel of the modul e (refer to Figure 6). Figur e 6. FX82051 Module Connection s As illustrated in Figure 6, FX82051 c onnections consist of the following: • Power connection NOTES: – A 12 VDC or 24 VA C power supply can be us ed to power the module when used a ...

  • Pelco C2622M - page 16

    16 C2622M (2/07) Figure 7. Fiber Port Connections in Point-to-Point Application ...

  • Pelco C2622M - page 17

    C2622M (2/0 7) 17 T roubleshooting LED indicators on the front and rear panels of the FX82051 module allow you to monitor operational status: • LED indicators on the front panel (refer to Fi gure 2) allow you to moni tor operating power , 100BASE-FX port status, and optic signal/laser status. Refer to T able B for information about the front-pane ...

  • Pelco C2622M - page 18

    18 C2622M (2/07) Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connections. Fiber ...

  • Pelco C2622M - page 19

    C2622M (2/0 7) 19 Ta b l e C . T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possi ble Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to Sett ...

  • Pelco C2622M - page 20

    20 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be established. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device. • Cable is defective. • Cable is not the proper cable type. • C ...

  • Pelco C2622M - page 21

    C2622M (2/0 7) 21 RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10 for information. ...

  • Pelco C2622M - page 22

    22 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10 ...

  • Pelco C2622M - page 23

    C2622M (2/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required. If 10BASE-T half- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port M ...

  • Pelco C2622M - page 24

    24 C2622M (2/07) Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Half-duplex or full-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and a ...

  • Pelco C2622M - page 25

    C2622M (2/0 7) 25 OPTICAL POWER BUDGET , TRANSMISSION DIST ANCE, AND LASER CLASS 1 LIMIT Model Number Wavelength (T ransm it/Receive) Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* Multimode (62.5/125 μm) FX82051MSTR-2 1310/1310 nm 26 dB † 6 km (3.7 mi) ‡ <15.6 mW FX82051MSCR-2 1310/1310 nm 26 dB † 6 km (3.7 mi) ...

  • Pelco C2622M - page 26

    26 C2622M (2/07) Appendix. RJ-45 Connector Pinouts Figure 8 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 8. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts. T able D. RJ-45 MDI/MDI-X Connector Pinouts Pin Number MDI (Normal Mode) MDI-X (Crossed Mode) 1R X + T X + 2R X - T X - 3 TX+ RX+ 4 Not used Not ...

  • Pelco C2622M - page 27

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warranty are as noted below: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr an ...

  • Pelco C2622M - page 28

    ® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ara ...

メーカー Pelco カテゴリー Switch

Pelco C2622Mのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C2622Mの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C2622Mの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C2622Mの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C2622Mの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C2622Mのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C2622Mの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C2622Mデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C2622Mを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C2622Mユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C2622Mの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C2622Mの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C2622Mに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C2622Mデバイスの基本機能を使うにあたってのヒント。 Pelco C2622Mのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C2622Mに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C2622Mのメーカー/サービスへの連絡先に関する情報。

Pelco C2622Mについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C2622Mの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C2622Mで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)