Agilent Technologies N9360Aの取扱説明書

44ページ 1.04 mb
ダウンロード

ページに移動 of 44

Summary
  • Agilent Technologies N9360A - page 1

    Agilent T echnologies Agilent N9360A Multi UE T ester Quick Reference Guide ...

  • Agilent Technologies N9360A - page 2

    Notices © Agilent T echnologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or transla- tion into a foreign language) without prior agreement and written consent from Agilent T echnologies, In c. as governed by United States and in ternational copyright laws. Manual Pa ...

  • Agilent Technologies N9360A - page 3

    N9360A Multi UE Tester Quick Reference Guide iii Preface Thank-you for purchasing the Agilent N9360A mobile communciations tester . • Before using the tester , the user is advised to read this manual carefully to ensure correct usage an d also to fully utilize the tester capability . • This manual is a reference document and the user is advised ...

  • Agilent Technologies N9360A - page 4

    iv N9360A Multi UE Tester Quick Reference Guide THIS P AGE IS INTENTIONALL Y LEF T BLANK. ...

  • Agilent Technologies N9360A - page 5

    N9360A Multi UE Tester Quick Reference Guide v Contents Notation I-iii Notices I-iii T rademarks I-iii 1 Legal Information Legal Information 1-2 Wa r r a n t y 1-2 T echnology Licenses 1-2 Restricted Rights Legend 1-2 Service And Support 1-3 Agilent On The W eb 1-3 Agilent By Phone 1-3 2 Caution and Safety Requirements Safety Information 2-2 Safety ...

  • Agilent Technologies N9360A - page 6

    vi N9360A Multi UE Tester Quick Reference Guide RF Channels 4-7 MS Power Control / Power Class 4-7 RX Level 4-9 RX Quality 4-10 5W - C D M A S y s t e m For Go/No-Go T esting 5-2 For Pinpointing Failures 5-3 For T roubleshooting 5-4 UARFCN 5-5 Mobile Phone Maximum Output Power 5-5 6 cdma2000 System When "CDMA Mode" is set to MC-1x mode 6- ...

  • Agilent Technologies N9360A - page 7

    1-1 Agilent T echnologies 1 Legal Information Wa r r a n t y 1-2 T echnology Licenses 1-2 Restricted Rights Legend 1-2 Service And Support 1-3 Agilent On The W eb 1-3 Agilent By Phone 1-3 ...

  • Agilent Technologies N9360A - page 8

    1-2 N9360A Multi UE Tester Quick Reference Guide 1 Legal Information Legal Information W arranty The material cont ained in th is document is pro vided “as is,” and is subject to being changed, wit h out notice, in future editions. Further , to the m axim um e xte nt p ermit ted b y ap plic able la w , Agilent disclaims all warranties, ei ther ...

  • Agilent Technologies N9360A - page 9

    Legal Information 1 N9360A Multi UE Tester Quick Reference Guide 1-3 Service And Support Any adjustment, maintenance, or repa ir of thi s product must be performed by qualified perso nnel. Contact your customer engineer t hrough y o ur local A gilent Technologies Service Center . Agilent On The W eb Y ou can f ind inf or mation about t echnical and ...

  • Agilent Technologies N9360A - page 10

    1-4 N9360A Multi UE Tester Quick Reference Guide 1 Legal Information THIS P AGE IS INTENTIONALL Y LEF T BLANK ...

  • Agilent Technologies N9360A - page 11

    2-1 Agilent T echnologies 2 Caution and Safety Requirements Safety Summary 2-2 Safety Notices 2-2 W arning Label 2-2 General 2-3 When Operating The T e ster 2-3 ...

  • Agilent Technologies N9360A - page 12

    2-2 N9360A Multi UE Tester Quick Reference Guide 2 Caution and Safety Requirements Safety Information Safety Summary The fo llowing general saf ety pr ecautions must be observed during all phases of operation of t his instr ument. Fa ilure t o compl y wit h t hese precautions or with specif ic war nings else where in t his manual violates safe ty s ...

  • Agilent Technologies N9360A - page 13

    Caution and Safety Requirements 2 N9360A Multi UE Tester Quick Reference Guide 2-3 General When Operating The T ester W ARNING The protection provided by the N9 360A tester may be impaired if the tester is used in a manner not specified by Agilent or the instructions on the display are not followed. W ARNING DO NOT INSTRUMENT COVERS. Operating pers ...

  • Agilent Technologies N9360A - page 14

    2-4 N9360A Multi UE Tester Quick Reference Guide 2 Caution and Safety Requirements THIS P AGE IS INTENTIONALL Y LEF T BLANK. ...

  • Agilent Technologies N9360A - page 15

    3-1 Agilent T echnologies 3 General Operation Using a USB memory device 3-2 Using the Knob on the Front Panel 3-2 Preparation for T ests 3-3 GSM/W -CDMA/cdma2000 Mobile Phone Repair Process 3-4 ...

  • Agilent Technologies N9360A - page 16

    3-2 N9360A Multi UE Tester Quick Reference Guide 3 General Operation Using a USB memory device A USB memor y device can be used to sav e and recall t he test pr oce dure s, to upd ate the firmwa re o f the T ester , and to sa ve screen images as image f iles. Saving and Recalling T est Procedures: All settings f or Au tomatic Te st, Manual Test , T ...

  • Agilent Technologies N9360A - page 17

    General Operation 3 N9360A Multi UE Tester Quick Reference Guide 3-3 Preparation for T ests Figure 3-1 Ty p i c a l Te s t S e t u p Connecting RF Signal: 1 Co nnec t the m obil e pho ne to the T es ter usin g the user -supplied RF Cable, opti onal Antenna Coupler , or optional Shield Case. 2 On the [Loss] screen obt ained from the [Initial], [Conf ...

  • Agilent Technologies N9360A - page 18

    3-4 N9360A Multi UE Tester Quick Reference Guide 3 General Operation GSM/W -CDMA/cdma2000 Mobile Phone Repair Process Figure 3-2 Mobile Phone Repair Process A typical GSM, W-CDMA and cd ma2000 mobile phone repair process at se rvice centers is basically divid ed into two processes, Incoming Ins pection and Mechanical & Module Repair . In each p ...

  • Agilent Technologies N9360A - page 19

    4-1 Agilent T echnologies 4 GSM System For Go/No-Go T esting 4-2 For Pinpointing Failures 4-3 For T roubleshooting 4-5 RF Channels 4-7 MS Power Control / Power Class 4-7 RX Level 4-9 RX Quality 4-10 ...

  • Agilent Technologies N9360A - page 20

    4-2 N9360A Multi UE Tester Quick Reference Guide 4 GSM System For Go/No-Go T esting Figure 4-1 [Automatic T est: Stand-by] Screen 1 Press the Automatic T est softke y on t he [Initial] screen in GSM syst em. 2 Mo ve the cursor t o the “Procedure” f ield, and select a pre-defined t est procedure. 3 Press the St art sof tkey. 4 Tur n th e mobile ...

  • Agilent Technologies N9360A - page 21

    GSM System 4 N9360A Multi UE Tester Quick Reference Guide 4-3 For Pinpointing Failures Figure 4-2 [Automatic T est: Stand-by] Screen 1 P er form the st eps described in “F or Go/No-Go T esting.” 2 Press the Screen>> sof tkey to set screen mode to Detail or Va l u e . T a ble 4-2 GSM Autom atic test sequence Step Action needed Location Upd ...

  • Agilent Technologies N9360A - page 22

    4-4 N9360A Multi UE Tester Quick Reference Guide 4 GSM System 3 Ro t ate th e kn ob to p lace the cu rso r in o ne o f the P ass /Fai l cells on the det ail screen or t est result cells on the value screen. Then, press the knob . 4 One of the follo wing measurement result screens is displa yed according to y our selection in step 3. • T o p rint ...

  • Agilent Technologies N9360A - page 23

    GSM System 4 N9360A Multi UE Tester Quick Reference Guide 4-5 For T roubleshooting Figure 4-4 [ Manual T est (GSM): Stand-by] Screen 1 Press the Manual T est sof tkey on t he [Initial ] screen. 2 Mo v e the cu rsor to the “ Pro ced ure” f iel d an d sel ect a pre-defined t est procedure. 3 Tur n the mobile phone on. 4 W ait for the completion o ...

  • Agilent Technologies N9360A - page 24

    4-6 N9360A Multi UE Tester Quick Reference Guide 4 GSM System Figure 4-5 V arious [Manual T est (GSM) : Stand-by] Screens 7 While “Connection” is hi ghlighted in t he test f low , press the Tr i g g e r softkey t o st art sing le measurement or the Tr i g g e r Sing /Cont softke y t o st ar t continuous measurement. Press the Tr i g g e r S i n ...

  • Agilent Technologies N9360A - page 25

    GSM System 4 N9360A Multi UE Tester Quick Reference Guide 4-7 Press the Tr i g g e r S i n g / Cont sof tk ey again t o ter minate t he continuous measurement. 9 In the graphical display , the marker function is available to read the dat a points by rotating the knob. On t he po wer ramp graph display , t he zoom function is also a vailable. 10 T o ...

  • Agilent Technologies N9360A - page 26

    4-8 N9360A Multi UE Tester Quick Reference Guide 4 GSM System 72 9 22 6 32 4 82 7 32 4 42 2 92 5 42 2 52 0 10 23 5 20 6 18 11 21 6 18 7 16 12 19 7 16 8 14 13 17 8 14 9 12 14 15 9 12 10 10 15 13 10 10 11 8 16 11 11 8 12 6 17 9 12 6 13 4 18 7 13 4 14 2 19 5 14 2 15 0 15 0 GSM 850 / 900 DCS1800 PCS1900 Power Class Max Power Control Level Power Class M ...

  • Agilent Technologies N9360A - page 27

    GSM System 4 N9360A Multi UE Tester Quick Reference Guide 4-9 RX Level T able 4-5 RX levels # RX Level # RX Level # RX Level 0 ≤− 110 dBm 22 –89 to –88 dBm 44 –67 to – 66 dBm 1 –110 to –109 dBm 23 –88 to –87 dBm 45 –66 to –65 dBm 2 –109 to –108 dBm 24 –87 to –86 dBm 46 –65 to –64 dBm 3 –108 to –107 dBm 25 – ...

  • Agilent Technologies N9360A - page 28

    4-10 N9360A Multi UE Tester Quick Reference Guide 4 GSM System RX Quality T able 4-6 RX Quality # RX Quality # RX Quality 0 <0.2 % 4 1.6 to 3.2 % 1 0.2 to 0.4 % 5 3.2 to 6.4 % 2 0.4 to 0.8 % 6 6.4 to 12.8 % 3 0.8 to 1.6 % 7 >12.8 % ...

  • Agilent Technologies N9360A - page 29

    5-1 Agilent T echnologies 5 W- C D M A S y s t e m For Go/No-Go T esting 5-2 For Pinpointing Failures 5-3 For T roubleshooting 5-4 UARFCN 5-5 Mobile Phone Maximum Output Power 5-5 ...

  • Agilent Technologies N9360A - page 30

    5-2 N9360A Multi UE Tester Quick Reference Guide 5 W-CDMA System For Go/No-Go T esting Figure 5-1 [Automatic T est: Stand-by] Screen 1 Press the Automati c T est sof tke y on t he [Initial] screen for W-C D MA s y st em . 2 Mo ve the cursor t o the “Procedure” f ield, and select a pre-defined t est procedure. 3 Press the St art sof tkey. 4 Tu r ...

  • Agilent Technologies N9360A - page 31

    W-CDMA System 5 N9360A Multi UE Tester Quick Reference Guide 5-3 For Pinpointing Failures Figure 5-2 [Automatic T est: Stand-by] Screen 1 P er form the st eps described in “F or Go/No-Go T esting.” 2 Press the Screen>> sof tkey to set screen mode to V alue. 3 Check the values of t he measurement results. T a ble 5-1 W-CDMA Automatic T est ...

  • Agilent Technologies N9360A - page 32

    5-4 N9360A Multi UE Tester Quick Reference Guide 5 W-CDMA System For T roubleshooting Figure 5-3 [Manual T est: Stand-by] Screen 1 Press the Manual T est sof tkey on the [Initial] sc reen. 2 Mo v e the cu rsor to the “ Pro ced ure” f iel d an d sel ect a pre-defined t est procedure. 3 Tur n the mobile phone on. 4 W ait for the completion of Loc ...

  • Agilent Technologies N9360A - page 33

    W-CDMA System 5 N9360A Multi UE Tester Quick Reference Guide 5-5 UARFCN Mobile Phone Maximum Output Power T able 5-2 W -CDMA Frequency Band Band Uplink ; mobile phone transmit Downlink ; mobile phone receive General Additional General Additional I 9612 to 9888 — 10562 to 10838 — II 9262 to 9538 12, 37, 62, 87, 112, 137, 62, 187, 212, 237, 262, ...

  • Agilent Technologies N9360A - page 34

    5-6 N9360A Multi UE Tester Quick Reference Guide 5 W-CDMA System THIS P AGE IS INTENTIONALL Y LEF T BLANK. ...

  • Agilent Technologies N9360A - page 35

    6-1 Agilent T echnologies 6 cdma2000 System When "CDMA Mode" is set to MC-1x mode 6- 2 When "CDMA Mode" is set to 1xEV -DO mode 6-6 ...

  • Agilent Technologies N9360A - page 36

    6-2 N9360A Multi UE Tester Quick Reference Guide 6 cdma2000 System When "CDMA Mode" is set to MC-1x mode For Go/No-Go T esting Figure 6-1 [Auto T est (MC-1x): Stand-by] Screen 1 Press the Automati c T est sof tke y on t he [Initial] screen in cdma2000 system 2 Mo v e the cu rsor to the " Pro cedu re" f iel d, a nd se lect a pre- ...

  • Agilent Technologies N9360A - page 37

    cdma2000 System 6 N9360A Multi UE Tester Quick Reference Guide 6-3 T a ble 6-1 cdma2000 Automatic T est Sequence Step Action Needed Location Update W ait until the Location Update is complete. MS Call (T alk) Dial an arbitrary number and press the Off Hook key on the mobile phone. T alk T alk to the mobile phone to judge its loop back sound quality ...

  • Agilent Technologies N9360A - page 38

    6-4 N9360A Multi UE Tester Quick Reference Guide 6 cdma2000 System For Pinpointing Failures Figure 6-2 [Auto T est (MC-1x): Stand-by] Screen 1 P er form the steps described in "For Go/N o-Go T esting.” 2 Press the Screen>> sof tke y t o set screen mode to V alue. 3 Check the values of t he measurement results. ...

  • Agilent Technologies N9360A - page 39

    cdma2000 System 6 N9360A Multi UE Tester Quick Reference Guide 6-5 For T roubleshooting Figure 6-3 [Manual T est (MC-1x): Stand-by] Screen 1 Press the Manual T est sof tkey on t he [Initial ] screen. 2 Mo v e the c urso r to the " Pro cedu re" fi eld an d sel ect a pre-defined t est procedure. 3 Set the Service Option f ield t o 32. 4 Tur ...

  • Agilent Technologies N9360A - page 40

    6-6 N9360A Multi UE Tester Quick Reference Guide 6 cdma2000 System When "CDMA Mode" is set to 1xEV -DO mode For Go/No-Go T esting Figure 6-4 [Auto T est (1xEV -DO): Stand-by] Screen 1 Press the Automati c T est soft k ey on t he [Initial] screen in cdma2000 system 2 Mo v e the cu rsor to the " Pro cedu re" f iel d, a nd se lect ...

  • Agilent Technologies N9360A - page 41

    cdma2000 System 6 N9360A Multi UE Tester Quick Reference Guide 6-7 For Pinpointing Failures Figure 6-5 [Auto T est (1xEV -DO): Stand-by] Screen 1 P er form the steps described in "For Go/N o-Go" T esting". 2 Press the Screen>> sof tkey to set screen mode to V alue. 3 Check the values of t he measurement results. T a ble 6-2 1xE ...

  • Agilent Technologies N9360A - page 42

    6-8 N9360A Multi UE Tester Quick Reference Guide 6 cdma2000 System For T roubleshooting Figure 6-6 [Manual T est (1xEV -DO): Stand-by] Screen 1 Press the Manual T est sof tkey on t he [Initial ] screen. 2 Mo v e the c urso r to the " Pro cedu re" fi eld an d sel ect a pre-defined t est procedure. 3 Press the UA TI Assign sof tk ey. 4 Tu r ...

  • Agilent Technologies N9360A - page 43

    cdma2000 System 6 N9360A Multi UE Tester Quick Reference Guide 6-9 RF Channel † The BAND15: A WS is available only wh en the Option C03 is installed in the T ester . T a ble 6-3 cdma2000 Frequency Band Radio System Channel Number BAND0: CEL US 1024 ~ 1323 991 ~ 1023 1 ~ 799 BAND1: PCS US 1024 ~ 1323 991 ~ 1023 1 ~ 799 BAND3: Cel JP 1041 ~ 1199 12 ...

  • Agilent Technologies N9360A - page 44

    6-10 N9360A Multi UE Tester Quick Reference Guide 6 cdma2000 System THIS P AGE IS INTENTIONALL Y LEF T BLANK. ...

メーカー Agilent Technologies カテゴリー Network Router

Agilent Technologies N9360Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- N9360Aの取扱説明書
- Agilent Technologiesの製品カード
- パンフレット
- またはAgilent Technologies N9360Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Agilent Technologies N9360Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Agilent Technologies N9360Aの取り付け説明書、サービスマニュアル、簡易説明書、またはAgilent Technologies N9360Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Agilent Technologies N9360Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Agilent Technologies N9360Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAgilent Technologies N9360Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのAgilent Technologies N9360Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Agilent Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Agilent Technologies N9360Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAgilent Technologies N9360Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Agilent Technologies N9360Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Agilent Technologies N9360Aデバイスの基本機能を使うにあたってのヒント。 Agilent Technologies N9360Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Agilent Technologies N9360Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAgilent Technologies N9360Aのメーカー/サービスへの連絡先に関する情報。

Agilent Technologies N9360Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAgilent Technologies N9360Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAgilent Technologies N9360Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)