    19.2V 1/2” CORDLESS IMP ACT WRENCH Model 96448 SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read ...

  • Chicago Electric 96448 - page 2

    Page 2 SKU 96448 For technical questions, please call 1-800-444-3353. CONTENTS IMPORT ANT SAFETY INFORMA TION ............................ 3 GENERAL SAFETY RULES ................................................. 4 Work Area ................................................................................... 4 Electrical Safety ...................... ...

  • Chicago Electric 96448 - page 3

    Page 3 SKU 96448 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product ha ...

  • Chicago Electric 96448 - page 4

    Page 4 SKU 96448 For technical questions, please call 1-800-444-3353. GENERAL SAFETY RULES W ARNING! Read all instructions Failure to follow all instructions listed below may result in electric shock, re, and/or serious injury . The term “power tool” in all of the warnings listed below refers to your mains-operated (corded) power tool or bat ...

  • Chicago Electric 96448 - page 5

    Page 5 SKU 96448 For technical questions, please call 1-800-444-3353. Do not overreach. Keep proper footing and balance at all times. d. This en- ables better control of the power tool in unexpected situations. Dress properly . Do not wear loose clothing or jewelry . Keep your hair , cloth- e. ing and gloves away from moving parts. Loose clothes, j ...

  • Chicago Electric 96448 - page 6

    Page 6 SKU 96448 For technical questions, please call 1-800-444-3353. Do not lay the tool down until it has come to a complete stop. Moving parts can 3. grab the surface and pull the tool out of your control. When using a handheld power tool, maintain a rm grip on the tool with both 4. hands to resist starting torque. Do not leave the tool unatt ...

  • Chicago Electric 96448 - page 7

    Page 7 SKU 96448 For technical questions, please call 1-800-444-3353. Only use the included battery to power the Inpact Wrench. Never attempt to use 1 1. a battery from any other powered tool in place of the battery for this tool. The warnings, precautions, and instructions discussed in this instruction manual 12. cannot cover all possible conditio ...

  • Chicago Electric 96448 - page 8

    Page 8 SKU 96448 For technical questions, please call 1-800-444-3353. 3-Prong Plug and Outlet Outlets for 2-Prong Plug Double Insulated T ools: T ools with T wo Prong Plugs T ools marked “Double Insulated” do not require grounding. They have a special 1. double insulation system which satises OSHA requirements and complies with the applicabl ...

  • Chicago Electric 96448 - page 9

    Page 9 SKU 96448 For technical questions, please call 1-800-444-3353. Make sure the extension cord is properly wired and in good electrical condition. 7. Always replace a damaged extension cord or have it repaired by a qualied elec - trician before using it. Protect the extension cords from sharp objects, excessive heat, and damp or wet 8. areas ...

  • Chicago Electric 96448 - page 10

    Page 10 SKU 96448 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Charger Input 120 V~, 60 Hz, 1.8 A Charger Output 7.2 - 24 V , 1.5 A Charge T ime 1-3/4 - 2 Hours. Speed 0-2300 RPM Maximum T orque 220 ft-lb Battery Cell T ype NiCd, 1700 mAh, 1.2 V , Item 96756 UNP ACKING When unpacking, check to make sure that the item is inta ...

  • Chicago Electric 96448 - page 11

    Page 1 1 SKU 96448 For technical questions, please call 1-800-444-3353. T rigger (36): Squeeze the T rigger to turn the Impact Wrench on and release pressure on the T rigger to turn the Impact Wrench of f. Forward/Reverse Switch (32): The Forward/Reverse Switch allows you to change the rotational direction of the Impact Wrench. For a clockwise rota ...

  • Chicago Electric 96448 - page 12

    Page 12 SKU 96448 For technical questions, please call 1-800-444-3353. When the Battery requires recharging, a 1-3/4 hour charge allows the tool to op - 3. erate at full power . Do not recharge the Battery longer than 2 hours, as damage to the Battery and/or Impact Wrench will occur . Slide the Battery off the handle of the Impact W rench. Insert t ...

  • Chicago Electric 96448 - page 13

    Page 13 SKU 96448 For technical questions, please call 1-800-444-3353. When nished, release the T rigger to stop the Impact Wrench. Then, remove the 7. Battery and socket from the tool. Make sure to store the Impact Wrench in a dry , clean location out of reach of chil- 8. dren and other unauthorized people. MAINTENANCE AND SERVICING Risk of ser ...

  • Chicago Electric 96448 - page 14

    Page 14 SKU 96448 For technical questions, please call 1-800-444-3353. When installing the Carbon Brushes, make sure the carbon portion of the Carbon 4. Brushes contact the Motor ’s Rotor and that the springs face away from the Motor . Also, make sure the springs operate freely . After replacement or cleaning, replace the two Brush Holder Caps. 5 ...

  • Chicago Electric 96448 - page 15

    Page 15 SKU 96448 For technical questions, please call 1-800-444-3353. PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUT OR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR W ARRANTY OF ANY KIND T O THE BUYER THA ...

  • Chicago Electric 96448 - page 16

    Page 16 SKU 96448 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts. 38 ...

  • Chicago Electric 96448 - page 17

    Page 17 SKU 96448 For technical questions, please call 1-800-444-3353. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod - uct is free from defects in materials and workmanship for the period of 90 days ...

メーカー Chicago Electric カテゴリー Impact Driver

Chicago Electric 96448のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 96448の取扱説明書
- Chicago Electricの製品カード
- パンフレット
- またはChicago Electric 96448の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Chicago Electric 96448の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Chicago Electric 96448の取り付け説明書、サービスマニュアル、簡易説明書、またはChicago Electric 96448のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Chicago Electric 96448の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Chicago Electric 96448デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがChicago Electric 96448を使用するのを助ける技術的文書のことです。説明書は通常、全てのChicago Electric 96448ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Chicago Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Chicago Electric 96448の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははChicago Electric 96448の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Chicago Electric 96448に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Chicago Electric 96448デバイスの基本機能を使うにあたってのヒント。 Chicago Electric 96448のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Chicago Electric 96448に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるChicago Electric 96448のメーカー/サービスへの連絡先に関する情報。

Chicago Electric 96448についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもChicago Electric 96448の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがChicago Electric 96448で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)