Lenoxx Electronics Optima 3 FSの取扱説明書

54ページ 4.1 mb
ダウンロード

ページに移動 of 54

Summary
  • Lenoxx Electronics Optima 3 FS - page 1

    INSTALLATION AND OPERATION MANUAL Freestanding Model Advantage  Optima  3 FS * FREESTANDING AND INSERT PELLET FIRED STOVES These appliances must be properly installed and operated in order to prevent the possibility of a house fire. Please read this entire owner's manual before installing and using your pellet stove. Failure to follow th ...

  • Lenoxx Electronics Optima 3 FS - page 2

    IMPORTANT WARNINGS CAUTION: Read this manual thoroughly before starting installati on. For y our safety, follow the installation, op- eration and maintenance instructions exactly without devi ation. Failure to follow these instructions may result in a possible fire hazard and w ill void the w arranty. If this appliance is not properly installed, a ...

  • Lenoxx Electronics Optima 3 FS - page 3

    TABLE OF CONTENTS PAGE 3 Important Warn ings ................................................ 2 Testing / Listing, EPA, Using this Manual ................ 3 Planning Your Inst allation ..................................... 4-9 Manufactured (Mobile) Ho me Installation ................ 9 Installati on ................................................. ...

  • Lenoxx Electronics Optima 3 FS - page 4

    PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood pellet burning appliances are improperly installed. The installer must follow all of the manufac- turers’ instructions. The installation of this a ...

  • Lenoxx Electronics Optima 3 FS - page 5

    PLANNING YOUR INSTALLATION PAGE 5 FLOOR PROTECTION - Optima 2 FS Thi s a ppl ia nce requires noncombustible floor protec- tion. If the floor protection is to be stone, tile, brick, etc., it must be mortared or grouted to form a continuous non-combustible surface. If a chimney connector ex- tends horizontally over the floor, the protection must cove ...

  • Lenoxx Electronics Optima 3 FS - page 6

    PLANNING YOUR INSTALLATION PAGE 6 FLOOR PROTECTION - Optima 3 FS The floor protector must meet or exceed the minimum thermal re- quirements as defined on this page (see Floor Protection/Hearth Ex- tension Using Alternate Material As Floor Pro- tector) . If the floor pro- tection is to be stone, tile, brick, etc., it must be mortared or grouted to f ...

  • Lenoxx Electronics Optima 3 FS - page 7

    PLANNING YOUR INSTALLATION Clearances to combustibles are determined from testing to applicable standards for allow- able heat transfer. The clearances allowed as shown here, do not take into account opera- tion or serviceability requirements. PAGE 7 CLEARANCES Optima 2 FS and Optima 3 FS - Standard residential or manufactured (mobile) home install ...

  • Lenoxx Electronics Optima 3 FS - page 8

    PLANNING YOUR INSTALLATION PAGE 8 MASONRY AND FACTORY BUILT FIREPLACES The model Optima 3 INS is approved for installation into a solid fuel burning fireplace, either a ma sonry fireplace (built to UBC 37 or ULC S628 standards) or an approved factory-built / zero clearance fireplace (built to UL 127 or ULC S610 standards). See pages 20 and 21 for a ...

  • Lenoxx Electronics Optima 3 FS - page 9

    PLANNING YOUR INSTALLATION PAGE 9 Models – Optima 2 FS and Optima 3 FS MANUFACTURED (MOBILE) HOME INSTALLATION Freestanding Models – Optima 2 FS and Optima 3 FS In addition to the standard installation instructions, the following instructions may be required by local, state or federal building codes: • Stove must be permanently bolted to the ...

  • Lenoxx Electronics Optima 3 FS - page 10

    INSTALLATION PAGE 10 REMOVING APPLIANCE FROM PALLET 1. After removing the packaging from the stove, lift the hop- per lid, and remove all pre-packaged items that were shipped in the hopper. Next, open the stove door and remove all pre-packaged items. 2. Using a socket or open end wrench (7/16" for freestand- ing units and 3/8" for the ins ...

  • Lenoxx Electronics Optima 3 FS - page 11

    INSTALLATION PAGE 11 INSTALLING SURROUND ASSEMBLY - Optima 3 INS (to be done after venting sy stem is installed) The surround kit (purchased separately) comes with a set of metal panels that enclose the fireplace opening when fitted together. There is also a trim assembly that frames the surround assembly to give it an attractive fin- ished appeara ...

  • Lenoxx Electronics Optima 3 FS - page 12

    INSTALLATION PAGE 12 Optima 3 INS ( O n l y ) – Install damper rod knob as ex- plained on page 11. Adjustment Procedure: The damper knob should be positioned in the center of the oblong slot for the aver- age installation (see illustration above). If more or less air is needed, then adjust in ¼" increments until opti- mum combustion air flo ...

  • Lenoxx Electronics Optima 3 FS - page 13

    INSTALLATION THERMOSTAT INSTALLATION: NOTE: Alw ays Disconnect Power Before Performing The Thermostat Installation . A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included in your stoves accessory package. It is rec- ommended that the thermostat and ther mostat wire be installed by an aut horized Lennox Hearth Products dealer. ...

  • Lenoxx Electronics Optima 3 FS - page 14

    INSTALLTION PAGE 14 VENTING REQUIREMENTS It is recommended that only an authorized dealer install your pellet stove. The specif ied installation requirements must be followed to ensure conformity with both the safety listing of the appliance and local building codes. All clearances, installation instructions and precautions specified by the vent ma ...

  • Lenoxx Electronics Optima 3 FS - page 15

    INSTALLTION PAGE 15 VENT TERMINATION Do not terminate vent in an enclosed or semi-enclosed area such as: carports, garage, attic, crawl space, under a deck, porch, narrow walkway, closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway etc. Vent surfaces can get hot enough to cause burn ...

  • Lenoxx Electronics Optima 3 FS - page 16

    INSTALLATION PAGE 16 DETERMINING SIZE OF PIPE TO INSTALL To determine what diameter pipe to use in an installation (3” or 4”), first find the “equivalent pipe length” using the follow- ing guidelines, then plot this figure and the altitude on the chart. Fill out the installation chart, and calculate your total equiva lent pipe length. After ...

  • Lenoxx Electronics Optima 3 FS - page 17

    INSTALLATION PAGE 17 INSTALLING YOUR FREESTANDING PELLET STOVE Standard Horizontal Vent Installation 1. Locate the proper positi on for the listed type “PL” wall thimble. Avoid cutting wall studs when installing your pipe. Use a saber saw or keyhole saw to cut the proper diameter hole through the wall to accom- modate the wall thimble. Use extr ...

  • Lenoxx Electronics Optima 3 FS - page 18

    INSTALLATION Standard Horizontal Installation Configurations Note: Horizontal run of pipe requires 1/4” (7 mm) rise per foot. PAGE 18 Optima 3 FS Corner Through the Wall Optima  2 FS and Optima  3 FS Horizontal Vent Through the Wall 3” (75 mm) Mini- mum clearance be- tween wall and pipe. If you vent to the furthest wall, the vent pipe mus ...

  • Lenoxx Electronics Optima 3 FS - page 19

    INSTALLATION ♦ USA & Canada – Requires an approved noncombustible h earth or floor protector, 3/8” / (10 mm) millboard or equivalent (k = .84, r = 1.19) to extend 6” / 150 mm to the front of the glass door. PAGE 19 Standard Vertical Inst allation Configurations Models: Optima 2 FS and Optima 3 FS These freestanding models may be connect ...

  • Lenoxx Electronics Optima 3 FS - page 20

    INSTALLATION - Optima 3 INS Standard Installation Configurations Into and Existing Fireplace – Model: O p t i m a  3 INS IMPORTANT- Make sure the chimney and firebox are clean and free of soot and ashes before installation begins. Fail- ure to do so may result in the transfer of soot into the room by way of the room air blower. ♦ USA & C ...

  • Lenoxx Electronics Optima 3 FS - page 21

    INSTALLATION INSTALLING OPTIMA 3 INS (CONTINUED) IMPORTANT- Make sure the chimney and firebox are clean and free of soot and ashes before installation begins. Fail- ure to do so may result in the transfer of soot into the room by way of the room air blower. Do not block opening at front of insert (below door). ♦ USA & Canada – Requires an a ...

  • Lenoxx Electronics Optima 3 FS - page 22

    CARE AND OPERATION PAGE 22 CONTROL BOARD OPERATION Stove On / Off Button – This button will turn your stove on or off while in Manual or Automatic mode (see page 25 for details). The green on / off light at the top of control board will indicate the on / off status. Heat Output Button – The heat output button has three selection settings, Low, ...

  • Lenoxx Electronics Optima 3 FS - page 23

    CARE AND OPERATION PAGE 23 Note: The control board is equipped w ith an internal memory which w ill recall the last setting and mode the stove was in prior to loss of pow er. Because we individually check each stove prior to packaging, one of the tw o scenarios w ill appear when you first plug in your stov e. 1). The Green LED at the top of the con ...

  • Lenoxx Electronics Optima 3 FS - page 24

    CARE AND OPERATION PAGE 24 Combustion Voltage Trim Steps: 1. Push button “twice” for access voltage calibration mode. 2. Identify the current calib ration setting indicated by one YELLOW LED bar. 3. Push the “HEAT” control button to adjust setting UP. Each push raises the YELLOW LED bar & increases voltage 5%. 4. Push the “BLOWER” c ...

  • Lenoxx Electronics Optima 3 FS - page 25

    CARE AND OPERATION PAGE 25 MANUAL OPERATION Pressing the stove on / off button initiates the start-up cycle. The green on / off light, near the top of the control board, will light up to indicate the “on” status. The fan speeds and pellet feeds are fixed during this time to pro- vide appropriate ignition. The Fast-Fire igniter system will light ...

  • Lenoxx Electronics Optima 3 FS - page 26

    CARE AND OPERATION PAGE 26 DAMPER OPERATION (All models) The damper is a plate that helps control the amount of airflow supplied for combustion. With the damper pushed all the way in the airflow is at its minimum. As the damper is pulled out, more air is allowed to flow. It will be necessary to monitor the appearance of the flame during the first 4 ...

  • Lenoxx Electronics Optima 3 FS - page 27

    CARE AND OPERATION PAGE 27 FUEL Clinkering - Silica (or sand) in the fuel, along with other impurities, can cause clinkering. A clinker is a hard mass of silica formed in the burning process. Clinkering is a function of the fuel, (not the stove), but adversely affects the performance of the stove by blocking off the air pas- sages in the grate. Eve ...

  • Lenoxx Electronics Optima 3 FS - page 28

    ROUTINE MAINTENANCE * Inspect your stov e or insert at minimum frequency st ated until you establish a minimum frequency required for your installation (frequency w ill vary depending upon fuel BT U value / ash content, usage, and misc. installation v ar iab les ). Unplug and Ensure Stove is Cold Before Performing Any Maintenance Work . Include rou ...

  • Lenoxx Electronics Optima 3 FS - page 29

    ROUTINE MAINTENANCE PAGE 29 3. Release both ash pan latches and pull forward. Models Optima 2 FS and Optima 3 FS Model Optima 3 INS 4. Remove the ash pan. Place ashes into a non- combustible container. When finished, close the glass door and slide the ash pan back into the stove and close the ash pan door. Reinstall ash pan cover panel. * (Minimum ...

  • Lenoxx Electronics Optima 3 FS - page 30

    ROUTINE MAINTENANCE PAGE 30 Pull Scraper Rod out & in several times REMOVABLE BAFFLE PLATES (All Models) At least once a year, the baffle plates (located in the firebox below exchange tubes) should be removed for cleaning (vacuum out, then reinstall baffle plates) Removing Baffle Plates The baffle plates contain keyhole slots allowing the screw ...

  • Lenoxx Electronics Optima 3 FS - page 31

    ROUTINE MAINTENANCE PAGE 31 Clean Photoeye Lens Remove Filter and Wipe Clean (Minimum frequency of 4 weeks - 6 months) CAUTION: If the filter is not reinstalled, reflective light in the room may result in a fault, thus shut- ting dow n of the unit. EXHAUST PASSAGES AND VENT PIPE (All Models) Inspect frequently and clean when necessary. Fly ash will ...

  • Lenoxx Electronics Optima 3 FS - page 32

    ROUTINE MAINTENANCE PAGE 32 DOOR ROPE GASKET (All Models) The condition of the rope gasket around the door and windows should be checked periodically and replaced or repaired if necessary. A one-inch strip of paper may be used to perform a test of the integrity of the door seal. Close the door on the paper in at least eight points (see illustration ...

  • Lenoxx Electronics Optima 3 FS - page 33

    ROUTINE MAINTENANCE PAGE 33 SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B Stove Paint, Cata- log # 70K99. Do not touch-up your stove with any other paint. Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth ...

  • Lenoxx Electronics Optima 3 FS - page 34

    SPECIFICATIONS - Optima 2 FS PAGE 34 Flue Size 3” / 76mm Rear Width, Overall 23” / 584mm Depth, Overall 22 3/4” / 578mm Depth, Overall w / 3” tee 28 1/2” / 724mm Height 28 5/8” / 727mm Floor to Rear Flue Center 11 1/4” / 286mm Facing back of unit, outside edge of left side to center of rear flue outlet center 6 1/2” / 165mm Floor to ...

  • Lenoxx Electronics Optima 3 FS - page 35

    SPECIFICATIONS - Optima 3 FS PAGE 35 Flue Size 3” / 76mm Rear Width, Overall 25 7/8” Depth, Overall 24 7/8” Depth, Overall w / 3” tee 30 3/4” Height 31 3/8” Floor to Rear Flue Center 16 7/8” Facing Back of Unit, outside edge on right to center of rear flue outlet 5 1/8” Floor to Rear Outside Air Inlet Located on center- line of pede ...

  • Lenoxx Electronics Optima 3 FS - page 36

    SPECIFICATIONS - Optima 3 INS Note: Dimensions shown are approximations only (+/- ¼”) + Non-combustible floor protection must be used when installed on carpet (see Floor Protection , page 5). ♦ Fuel delivery and burn times will vary depending on size and ty pe of fuel used. Estimated heat input based on fuel value of 8400 BTU per lb. * Fuses a ...

  • Lenoxx Electronics Optima 3 FS - page 37

    COMPONENT DEFINITIONS PAGE 37 AIR WASH To inhibit buildup of soot on the door glass, air is deliv- ered to the glass through an air wash system located in the doorframe surrounding the glass. AUGER It transfers the fuel down the burner tube into the burn grate. AUGER MOTOR Drives the Auger. Motor specif ications are: .4 Amp, 1 rpm (revolutions per ...

  • Lenoxx Electronics Optima 3 FS - page 38

    WIRING DIAGRAM PAGE 38 ...

  • Lenoxx Electronics Optima 3 FS - page 39

    TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 39 PROBLEM CA USE(S) SOLUTIONS 1. Fire burns with a lazy orange flame. Pellets build up in the grate and there is excessive glass soot that is difficult to remove (Ash and soot are a product of combustion with any wood products, so ...

  • Lenoxx Electronics Optima 3 FS - page 40

    TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 40 PROBLEM CA USE(S) SOLUTIONS 4. Blowers w ill not operate when the start button is de- pressed. There is no power to the stove. There is no power to the control board. Check that the stove is plugged in to the wall outlet. Check t ...

  • Lenoxx Electronics Optima 3 FS - page 41

    TROUBLESHOOTING Qualified Technicians Only Unplug Appliance Before Performing Any Troubleshooting or Maintenance PAGE 41 Troubleshooting Notes for Qualified Technicians only: 1.) If a ‘tri-ac’ (switching device within the controls) is blown for a particular component, it is possible for that component to run continuously. The ‘tri-ac’ can b ...

  • Lenoxx Electronics Optima 3 FS - page 42

    REPLACEMENT PARTS LIST PAGE 42 Door Parts & Body Components Ite m # Pa r t N o. / C a t. No . Description Stove Model 2 14650460 Door Assembly, Cast Iron Firebox Optima 2 FS 2 14750458 Door Assembly, Cast Iron Firebox Optima 3 FS & INS 15051547 Gasket Kit, Door, ¾” Rope, (8 Ft.) Optima 2 FS 61051000 Gasket Kit, Door, 1” Rope, (7 Ft.) O ...

  • Lenoxx Electronics Optima 3 FS - page 43

    REPLACEMENT PARTS LIST PAGE 43 Firebox Parts Item # Part # Description Stove Model 29 13640028 Clips, Brick Optima 2 FS 30 11750011 Clips, Brick Optima 3 FS & INS 31 14650011 Firebrick Set, 1 pc. Optima 2 FS 32 14750015 Firebrick Set, 3 pc. Optima 3 FS & INS 33 14650428 H ou s in g, Ig n it er T ube Op ti ma 2 F S 34 14750421 H ou s in g, I ...

  • Lenoxx Electronics Optima 3 FS - page 44

    REPLACEMENT PARTS DIAGRAMS PAGE 44 5 6 8 10 1 3 14 9 12 7 11 ...

  • Lenoxx Electronics Optima 3 FS - page 45

    REPLACEMENT PARTS DIAGRAMS PAGE 45 1 5 1 6 17 1 9 2 0 22 24 2 5 2 6 27 18 23 ...

  • Lenoxx Electronics Optima 3 FS - page 46

    REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 33 34 39 31 32 35 ...

  • Lenoxx Electronics Optima 3 FS - page 47

    REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42 ...

  • Lenoxx Electronics Optima 3 FS - page 48

    OPTIONAL ACCESSORIES DIAGRAMS PAGE 48 Optional Accessories Item # Part # Model Description Stove Model 1 H0448 TKAO2-G Trim Kit, AO2 Gold Optima 2 FS 1 H0449 TKAO2-N Trim Kit, AO2 Nickel Optima 2 FS 1 H0450 TKAO3-G Trim Kit, AO3 Gold Optima 3 FS & INS 1 H0451 TKAO3-N Trim Kit, AO3 Nickel Optima 3 FS & INS 2 14M81 QDPC-4 Quick Disconnect Pip ...

  • Lenoxx Electronics Optima 3 FS - page 49

    INSTALLATION TIPS PAGE 49 ...

  • Lenoxx Electronics Optima 3 FS - page 50

    SIMPLE OPERATING INSTRUCTIONS LABEL PAGE 50 ...

  • Lenoxx Electronics Optima 3 FS - page 51

    SAFETY/LISTING LABEL – Model Optima 2 FS PAGE 51 Note that your stove’s serial number is printed on the safety label, which is located near the inside of the hopper. Your stove’s serial number is preceded by a “WH-”(Example WH-0000000). ...

  • Lenoxx Electronics Optima 3 FS - page 52

    SAFETY/LISTING LABEL – Model Optima 3 FS and Optima 3 INS PAGE 52 Note that your stove’s serial number is printed on the safety label, which is located near the inside of the hopper. Your stove’s serial number is preceded by a “WH-”(Example WH-0000000). ...

  • Lenoxx Electronics Optima 3 FS - page 53

    PAGE 53 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

  • Lenoxx Electronics Optima 3 FS - page 54

    1110 West Taft Avenue Orange, CA 92865 ...

メーカー Lenoxx Electronics カテゴリー Stove

Lenoxx Electronics Optima 3 FSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Optima 3 FSの取扱説明書
- Lenoxx Electronicsの製品カード
- パンフレット
- またはLenoxx Electronics Optima 3 FSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lenoxx Electronics Optima 3 FSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lenoxx Electronics Optima 3 FSの取り付け説明書、サービスマニュアル、簡易説明書、またはLenoxx Electronics Optima 3 FSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lenoxx Electronics Optima 3 FSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lenoxx Electronics Optima 3 FSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLenoxx Electronics Optima 3 FSを使用するのを助ける技術的文書のことです。説明書は通常、全てのLenoxx Electronics Optima 3 FSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lenoxx Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lenoxx Electronics Optima 3 FSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLenoxx Electronics Optima 3 FSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lenoxx Electronics Optima 3 FSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lenoxx Electronics Optima 3 FSデバイスの基本機能を使うにあたってのヒント。 Lenoxx Electronics Optima 3 FSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lenoxx Electronics Optima 3 FSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLenoxx Electronics Optima 3 FSのメーカー/サービスへの連絡先に関する情報。

Lenoxx Electronics Optima 3 FSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLenoxx Electronics Optima 3 FSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLenoxx Electronics Optima 3 FSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)