    RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4 Tel : 905-856-5288 I Fax : 905-856-199 5 I Toll Free: 1-888-264-0006 RuggedSwitch ™ M2100 MIL-STD 19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports Installation Guide www.RuggedCom.com ...

  • RuggedCom M2100 - page 2

    2 © 2008 RuggedCom Inc. All rights re served Rev106 Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limit s are designed to provide reasonable protection against harmful interference w ...

  • RuggedCom M2100 - page 3

    3 © 2008 RuggedCom Inc. All rights re served Rev106 T able of Content s 1 Table of Figur es ............................................................................................................... ....... 4 2 Table of Tables ................................................................................................................ .... ...

  • RuggedCom M2100 - page 4

    4 © 2008 RuggedCom Inc. All rights re served Rev106 1 T able of Figures Figure 1: Ethernet panel LED de scription...................................................................................... .. 7 Figure 2: 10FL ST connector................................................................................................... ........ 8 Figure ...

  • RuggedCom M2100 - page 5

    5 © 2008 RuggedCom Inc. All rights re served Rev106 3 Product Overview 3.1 Functional Overview & Feature Highlights The RuggedSwitch™ M2100 is an MIL-STD hardened, fully managed, modular, Ethernet switch specifically designed to operate reliably in harsh environments. The M2100's superior ruggedized hardware design coupled with the embe ...

  • RuggedCom M2100 - page 6

    6 © 2008 RuggedCom Inc. All rights re served Rev106 • MIL-STD 167 – Vibration • MIL-STD 461 – EMI • MIL-STD 1399 – Magnetic Fiel d (DC Magnetic Exposure) • MIL-STD 810 – Temperature and Humidity Universal Power Supply Options • Fully integrated, dual-redundant (optional) power supplies • Universal high-voltage range: 88-300VDC ...

  • RuggedCom M2100 - page 7

    7 © 2008 RuggedCom Inc. All rights re served Rev106 3.2 Ethernet Panel Description Each Ethernet module is equipped with two LEDs that i ndicate link/activity status information. The LED will be solid for ports with link, and wi ll blink for activity. The diagram in Figure 1 highlights the port and the associated link/activity LED. Figure 1: Ether ...

  • RuggedCom M2100 - page 8

    8 © 2008 RuggedCom Inc. All rights re served Rev106 3.2.1 Fiber Optical Transceive r Orientation and Connection Depending on the order code of the product, the M2000 series products can be equipped with several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be properly connected and matc hed ...

  • RuggedCom M2100 - page 9

    9 © 2008 RuggedCom Inc. All rights re served Rev106 3.3 Display Panel Description The M2000 series products are equipped with a versatile display panel, shown in Figure 5, which is designed to provide quick status information for eac h port, as well as the entire device to allow for simple diagnostics and troubl eshooting. It features: • RS232 c ...

  • RuggedCom M2100 - page 10

    10 © 2008 RuggedCom Inc. All rights re served Rev106 The port-based LEDs can be cycled between three display modes: Status, Duplex, and Speed. Pushing the mode button causes the display mode to be cycled. Mode Colour Description Green (Solid) Link Green (Blinking) Activity Status Off No link Green (Solid) Full-Duplex operation Orange (Solid) Half- ...

  • RuggedCom M2100 - page 11

    11 © 2008 RuggedCom Inc. All rights re served Rev106 4 Inst allation 4.1 Panel Mounting The M2000 series products can be ordered with Panel mount chassis. This option involves the use of the panel adapters to be mounted on each side of the chassis enclosure. See Figure 6 for a Panel mount diagram. Figure 6: M2100 Panel Mounting Diagram ...

  • RuggedCom M2100 - page 12

    12 © 2008 RuggedCom Inc. All rights re served Rev106 4.2 Power Supply Wiring and Grounding Figure 7: M2000 Series Philips Screw Terminal Block The M2000 Family supports dual redundant power s upplies – “Power Supply 1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 and t he fail-safe relay are located on the terminal bloc ...

  • RuggedCom M2100 - page 13

    13 © 2008 RuggedCom Inc. All rights re served Rev106 Terminal # Description Usage 1 PS1 Live / + PS1 Live / + is connected to the posit ive (+) terminal if the power source is DC or to the (Live) terminal if the power source is AC. 2 PS1 Surge Ground PS1 Surge Ground is connected to the Chassis Ground via a jumper on the terminal blo ck. Surge Gro ...

  • RuggedCom M2100 - page 14

    14 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.1 AC Power Supply Wiring Ex am ples Figure 8: AC Power supply wiring examples NOTES: 1. 100-240VAC rated equipment: A 250VAC appropria tely rated circuit breaker must be installed within 3m of unit. 2. Equipment must be installed according to the applicable country wiring codes. 3. When equi ...

  • RuggedCom M2100 - page 15

    15 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.2 DC Power Supply Wiring Ex am ples Figure 9: DC Power supply wiring examples NOTES: 1. 88-300VDC rated equipment: A 300VDC appropria tely rated circuit breaker must be installed within 3m of unit. 2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies. 3. For dual DC ...

  • RuggedCom M2100 - page 16

    16 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.3 Dual Power Suppl ies – DC and AC Inputs Figure 10: DC And AC power supply wiring examples NOTES: 1. 88-300VDC rated equipment: A 300VDC appropria tely rated circuit breaker must be installed within 3m of unit. 2. 100-240VAC rated equipment: A 250VAC appropria tely rated circuit breaker m ...

  • RuggedCom M2100 - page 17

    17 © 2008 RuggedCom Inc. All rights re served Rev106 4.3 Dielectric Strength (HIPOT) Testing For dielectric strength (HIPOT) testing in the fiel d, users must remove the metal jumper located on terminal 2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression circuitry to chassis ground and must be removed i ...

  • RuggedCom M2100 - page 18

    18 © 2008 RuggedCom Inc. All rights re served Rev106 4.4 Failsafe Alarm Relay Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on the M2000 series switches. The contacts are energi zed upon power up of the unit and remain energized until a critical error occurs. Th e proper re ...

  • RuggedCom M2100 - page 19

    19 © 2008 RuggedCom Inc. All rights re served Rev106 4.5 Console Port Wiring A RS232 console port for configuration and m anagement of the device is located on the LED display module shown in Figure 13. This port is intended to be a temporary connection during initial configuration or troubleshoot ing and allows for direct acce ss to the serial-ba ...

  • RuggedCom M2100 - page 20

    20 © 2008 RuggedCom Inc. All rights re served Rev106 4.6 Twisted-Pair Data Ports 4.6.1 Micro-D Twisted-Pair Data Ports The M2100 may have several 10/100/1000BaseTX por ts that allow connection to standard CAT-5 UTP cable with Micro-D connectors. Figure 15 shows the Micro-D port pin configuration. Pi n Si gnal 1T X + 2 No C o nne c t i o n 3 No C o ...

  • RuggedCom M2100 - page 21

    21 © 2008 RuggedCom Inc. All rights re served Rev106 4.6.2 RJ45 Twisted-Pair Data Ports The M2100 series switches may have several 10/100BaseTX ports that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground and can accept shielded CAT-5 cables. If shielded cables ...

  • RuggedCom M2100 - page 22

    22 © 2008 RuggedCom Inc. All rights re served Rev106 4.6.3 Protection on Tw isted-Pair Data Ports RuggedCom does not recommend the use of CAT-5 c abling of any length for critical real-time substation automation applications. However, trans ient suppression circuitry is present on all copper ports to protect against damage from elec trical transie ...

  • RuggedCom M2100 - page 23

    23 © 2008 RuggedCom Inc. All rights re served Rev106 4.7 Gigabit Ethernet 1000Base-T X Cabling Recommendations The IEEE 802.3ab Gigabit Ethernet standard defines 1000Mbit/s Ethernet communications over distances of up to 100 meters using 4 pairs of category 5 (or higher) balanc ed unshielded twisted- pair cabling. For wiring guidelines, system des ...

  • RuggedCom M2100 - page 24

    24 © 2008 RuggedCom Inc. All rights re served Rev106 5 T echnical S pecifications 5.1 Power Supply Specifications Input Range Max. Power Consumption 3 Power Supply Type Min Max Fuse Rating 10/100TX FE Ports Worst Case 12 – 24 VDC 10 VDC 36 VDC 6.3A(F) 2 24 VDC 18 VDC 36 VDC 5A(F) 2 48 VDC 36 VDC 59 VDC 2A(T) 2 HI (125/250 VDC) 1 HI (110/230 VAC) ...

  • RuggedCom M2100 - page 25

    25 © 2008 RuggedCom Inc. All rights re served Rev106 5.3 Networking Standards Supported Parameter 10Mbps Ports 100Mbps Ports 1000Mbps Ports Notes IEEE 802.3 9 10BaseT / 10BaseFL IEEE 802.3u 9 100BaseTX / 100BaseFX IEEE 802.3z 9 1000BaseSX/LX IEEE 802.3ab 9 1000BaseTx IEEE 802.3x 9 9 9 Full Duplex Operation IEEE 802.1D 9 9 9 MAC Bridges IEEE 802.1Q ...

  • RuggedCom M2100 - page 26

    26 © 2008 RuggedCom Inc. All rights re served Rev106 5.5 Fiber Optical Specifications The following sections detail fiber optical specif ications on ports that can be ordered with the M2100 series Ethernet switch. The user determines the type of optic s at time of ordering, and can determine the modules installed on a particular unit by reading th ...

  • RuggedCom M2100 - page 27

    27 © 2008 RuggedCom Inc. All rights re served Rev106 5.5.2 Gigabit Ethernet (1000Mbps) Modul es For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The following t able details fiber optic specifications based on the 2-port modules or pluggable transceiv ers selected at ...

  • RuggedCom M2100 - page 28

    28 © 2008 RuggedCom Inc. All rights re served Rev106 5.6 Type Test Specifications Electrical Safety Levels Comments Dielectric Withstand 2 kV RMS for 1 minute ANSI/IEEE C37.90 (1989) IEC 60255-5 (Section 6) High Voltage Impulse 5 kV peak IEC 60255-5 (Section 8) Insulation Resistance 500 VDC for 1 minute IEC 60255-5 (Section 6 Electrical Environmen ...

  • RuggedCom M2100 - page 29

    29 © 2008 RuggedCom Inc. All rights re served Rev106 5.8 Mechanical Specifications Parameter Value Comments Dimensions 19.00x 14.5 x 2.02 inches (482.6)x (368.3) x (51.3) mm (Length x Width x Height) with mounting brackets installed Weight 11.2 lb (5 Kg) with mounting brackets installed Enclosure 18awg galvanized steel Figure 17: Mechanical Dimens ...

  • RuggedCom M2100 - page 30

    30 © 2008 RuggedCom Inc. All rights re served Rev106 6 Agency Approvals Agency Standards Comments CE EN 60950, EN 61000-6-2 CE Compliance is claimed via Declaration of Self Conformity Route FCC FCC Part 15, Class A Passed CISPR EN55022, Class A Passed FDA/CDRH 21 CFR Chapter 1, Subchapter J Passed IEC/EN EN60825-1:1994 + A11:1996 + A2:2001 Passed ...

メーカー RuggedCom カテゴリー Switch

RuggedCom M2100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- M2100の取扱説明書
- RuggedComの製品カード
- パンフレット
- またはRuggedCom M2100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、RuggedCom M2100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、RuggedCom M2100の取り付け説明書、サービスマニュアル、簡易説明書、またはRuggedCom M2100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、RuggedCom M2100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

RuggedCom M2100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRuggedCom M2100を使用するのを助ける技術的文書のことです。説明書は通常、全てのRuggedCom M2100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

RuggedComの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. RuggedCom M2100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRuggedCom M2100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。RuggedCom M2100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. RuggedCom M2100デバイスの基本機能を使うにあたってのヒント。 RuggedCom M2100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。RuggedCom M2100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRuggedCom M2100のメーカー/サービスへの連絡先に関する情報。

RuggedCom M2100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRuggedCom M2100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRuggedCom M2100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)