    Homeowner ’ s Installation and Operating Manual SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJURY OR EVEN DEA TH. CONT ACT LOCAL BUIL ...

  • Vermont Casting 1695CE - page 2

    2 V er mont Castings Intrepid Multi-Fuel 2000970 All of us at CFM Corporation Save These Instructions For Future Reference T able of Contents Specifications .................................... 3 Installation ......................................... 4 Assembly ......................................... 1 1 Operation ............................... ...

  • Vermont Casting 1695CE - page 3

    3 V er mont Castings Intrepid Multi-Fuel 2000970 Specifications Intrepid Multi-Fuel, Model 1695CE, 1696CE, 1697CE 546 mm (21  ") 508 mm (20") 641 mm (25  ") T op exit flue collar height 540 mm (21  ") 635 mm (25") 181 mm (7  ") 546 mm (21  ") C L 540 mm 21  &q ...

  • Vermont Casting 1695CE - page 4

    4 V er mont Castings Intrepid Multi-Fuel 2000970 Installation SAFETY NOTICE: IF YOUR STOVE IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AREA. Before you ...

  • Vermont Casting 1695CE - page 5

    5 V er mont Castings Intrepid Multi-Fuel 2000970 Masonry Chimneys An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney . The chimney should have no cracks, loose mortar , other signs of deterioration, or blockage. Repair any defects before using the chimney with your stove. Seal any unused openings in an ex ...

  • Vermont Casting 1695CE - page 6

    6 V er mont Castings Intrepid Multi-Fuel 2000970 the stove and chimney . Using connectors and chim- neys from the same manufacturer makes the assembly and installation straightforward. NOTE: For installations using double-wall con- nectors, minimum clearances must conform to the listed clearances in the clearance chart on Page 9. Single-wall Chimne ...

  • Vermont Casting 1695CE - page 7

    7 V er mont Castings Intrepid Multi-Fuel 2000970 Fireplace Chimney Installations - Through a Fireplace If your fireplace height is at least 635 mm (25”), you may install an Intrepid Multi-fuel with standard legs through the fireplace opening using a 90° T ee kit avail- able from your local dealer . This positive connection kit ensures a tight ...

  • Vermont Casting 1695CE - page 8

    8 V er mont Castings Intrepid Multi-Fuel 2000970 Hearths This appliance must be installed on to hearth that meets the requirements of Part J of the Building Regu- lations 2000 (Combustion Appliances and Fuel Storage Systems). This can be achieved by ensuring that the hearth is constructed and sized in accordance with the guidelines included in sect ...

  • Vermont Casting 1695CE - page 9

    9 V er mont Castings Intrepid Multi-Fuel 2000970 Costructional Hearth Dimensions as below At least 300 mm At least 150 mm or to a suitable heat resistant wall At least 150 mm Hearth Surface Free of Com- bustible Material Perimeter should be clearly marked e.g. edge of superimposed hearth Perimeter should be clearly marked e.g. edge of superimposed ...

  • Vermont Casting 1695CE - page 10

    10 V er mont Castings Intrepid Multi-Fuel 2000970 Connecting Flue Pipe - Clearances Single wall connecting fluepipes can reach extremely high temperatures; therefore, clearances from the con- necting fluepipe (chimney connector) must comply with the requirements of Part J of Building Regulations 2000 (Combustion Appliances and Fuel Storage System ...

  • Vermont Casting 1695CE - page 11

    1 1 V er mont Castings Intrepid Multi-Fuel 2000970 Clean the Griddle Before Use At the factory we coat the griddle with vegetable oil to prevent rusting while the stove is in transit and storage. Remove the oil with a dry rag or paper towel before you use the stove. Set Up the Stove Remove the griddle, front grate bar , the bottom grate, the side b ...

  • Vermont Casting 1695CE - page 12

    12 V er mont Castings Intrepid Multi-Fuel 2000970 ST516 Attach  gr iddle handle 11/17/00 djt ST516 Fig. 16 Attaching the griddle handle. ST517 Intrepid II  Ther mostat  positions  11/17/00 djt High Heat Low Heat ST517 Fig. 18 The thermostat handle may be positioned anywhere between the two extremes for different heat levels. Re ...

  • Vermont Casting 1695CE - page 13

    13 V er mont Castings Intrepid Multi-Fuel 2000970 ST519 Intrepid II damper 11/20/00 djt Open (Updraft Mode) Closed (Bypass Mode) ST519 Fig. 19 The damper is either open or closed. There are no intermediate positions. Side View The damper has no intermediate positions. When closing the damper , push firmly until you feel the mechanism enga ...

  • Vermont Casting 1695CE - page 14

    14 V er mont Castings Intrepid Multi-Fuel 2000970 Use the Air Control Settings that Work Best for Y ou No single air control setting will fit every situation. Set- tings will differ depending on the quality of the fuel, the amount of heat desired, and how long you wish the fire to burn. The control setting also depends on your particular installa ...

  • Vermont Casting 1695CE - page 15

    15 V er mont Castings Intrepid Multi-Fuel 2000970 Once the draft is established, open the front door and light the rest of the fuel from the bottom. Do not light the main bed of fuel until the chimney begins drawing, and repeat the procedure as often as necessary if the initial attempt is unsuccessful. 4. If your stove has been broken-in previously ...

  • Vermont Casting 1695CE - page 16

    16 V er mont Castings Intrepid Multi-Fuel 2000970 Draft Management A stove is part of a system, which includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well. Wood stove operation depends on natural (unfo ...

  • Vermont Casting 1695CE - page 17

    17 V er mont Castings Intrepid Multi-Fuel 2000970 - so use whatever combination of installation features and operational steps will encourage good draft and minimize creosote production. Because letting the smoke cool off and slow down is one of the keys to creosote production, it makes sense to line a chimney to match the stove’s outlet size, fo ...

  • Vermont Casting 1695CE - page 18

    18 V er mont Castings Intrepid Multi-Fuel 2000970 Place the gasket in its channel; make sure that its outer edge fits against the cast iron surround ridge. 3. Install the glass. Lay the glass on the inner gasket with the coated side down (toward the outside of the door). T ighten the screws snugly , but loose enough to allow for a little movement ...

  • Vermont Casting 1695CE - page 19

    19 V er mont Castings Intrepid Multi-Fuel 2000970 How to Adjust the Door Latch Over time, the gasketing around the doors will com- press, and the latch may need adjustment. T o adjust the latch, loosen the small locking nut, extend the striker screw one turn while keeping the striker screw from turning. (Fig. 27) Keep making adjustments a little at ...

  • Vermont Casting 1695CE - page 20

    20 V er mont Castings Intrepid Multi-Fuel 2000970 7. For doors, replace the doors and close them on a piece of waxed paper to keep the cement from migrating onto the stove front, or tap other parts with the rubber mallet (or hammer/block of wood). 8. Clean excess cement from around the channel. Let the cement that holds the new gasket dry thoroughl ...

  • Vermont Casting 1695CE - page 21

    21 V er mont Castings Intrepid Multi-Fuel 2000970 Stove Serial No. __________________________ Dealer _________________________________ ________________________________________ ________________________________________ Phone __________________________________ Date Purchased __________________________ Installer ___________________________ ____________ ...

  • Vermont Casting 1695CE - page 22

    22 V er mont Castings Intrepid Multi-Fuel 2000970 1 2 3 4 5 6 7 8 9 10 12 13 20 21 22 23 24 9 25 26 29 30 28 27 25 50 51 52 53 54 16 1 1 12 9 55 0970 Intrepid Multi-fuel 1695 8/02 35 49 45 45 46 56 56 14 57 0970 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at an ...

  • Vermont Casting 1695CE - page 23

    23 V er mont Castings Intrepid Multi-Fuel 2000970 0970 60 61 62 63 64 65 66 67 68 69 85 75 84 94 93 92 91 90 59 70 71 94 95 86 83 66 0970 Intrepid MultiFuel Model 1695 parts 8/02 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Intrepid ...

  • Vermont Casting 1695CE - page 24

    24 V er mont Castings Intrepid Multi-Fuel 2000970 Intrepid Multi-Fuel Heater Model 1695CE (continued) Shell Enamel Parts - Intrepid Multi-Fuel Model 1695CE Part Name Classic Green Red T op 1308657 2318657 2328657 Bottom 1306764 2316764 2326764 Left Side 1308656 2318656 2328656 Front 1308647 2318647 2328647 Left Door 1308649 2318649 2328649 Right Do ...

  • Vermont Casting 1695CE - page 25

    25 V er mont Castings Intrepid Multi-Fuel 2000970 ...

  • Vermont Casting 1695CE - page 26

    26 V er mont Castings Intrepid Multi-Fuel 2000970 ...

  • Vermont Casting 1695CE - page 27

    27 V er mont Castings Intrepid Multi-Fuel 2000970 Exclusions & Limitations 1. This warranty is transferable; however , proof of original retail pur- chase is required. 2. This warranty does not cover misuse of the stove. Misuse includes overfiring which will result if the stove is used in such a manner as to cause one or more of the plates to ...

  • Vermont Casting 1695CE - page 28

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

メーカー Vermont Casting カテゴリー Electric Heater

Vermont Casting 1695CEのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1695CEの取扱説明書
- Vermont Castingの製品カード
- パンフレット
- またはVermont Casting 1695CEの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vermont Casting 1695CEの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vermont Casting 1695CEの取り付け説明書、サービスマニュアル、簡易説明書、またはVermont Casting 1695CEのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vermont Casting 1695CEの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vermont Casting 1695CEデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVermont Casting 1695CEを使用するのを助ける技術的文書のことです。説明書は通常、全てのVermont Casting 1695CEユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vermont Castingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vermont Casting 1695CEの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVermont Casting 1695CEの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vermont Casting 1695CEに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vermont Casting 1695CEデバイスの基本機能を使うにあたってのヒント。 Vermont Casting 1695CEのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vermont Casting 1695CEに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVermont Casting 1695CEのメーカー/サービスへの連絡先に関する情報。

Vermont Casting 1695CEについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVermont Casting 1695CEの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVermont Casting 1695CEで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)