  • Master Lock B100 - page 1

    R G 011 Models: B30, B70, B100, B150 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. 150 SIDE PV 004 100 SIDE PV 002 POR T ABLE FORCED AIR HEA TERS O WNER’S MANU AL ...

  • Master Lock B100 - page 2

    100743 2 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ........................................... ...

  • Master Lock B100 - page 3

    3 100743 SAFETY INFORMA TION ! W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. ! D ANGER Carbon monoxide poisoning may lead ...

  • Master Lock B100 - page 4

    100743 4 Fuel Cap Lower Shell Power Cord Upper Shell Figure 3 - 150,000 BTU/Hr Model Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 30/70,000 BTU/Hr Models Side Cover Fuel Tank Lower Shell Fuel Cap Fan Guard Power Cord Upper Shell PR ODUCT IDENTIFICA TION Upper Shell Hot Air Outlet Hot Air Outlet Hot Air Outlet Air Filter End Cover Fan ...

  • Master Lock B100 - page 5

    5 100743 UNP A CKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 90,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles. Wheels, handles, and ...

  • Master Lock B100 - page 6

    100743 6 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion cham ...

  • Master Lock B100 - page 7

    7 100743 VENTILA TION ! W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater. Provide a fresh air opening of at least three square feet (2800 square cm) for each 100,0 ...

  • Master Lock B100 - page 8

    100743 8 OPERA TION Continued Figure 8 - Flame-Out Control Reset Button, 150,000 BTU/Hr (Optional Extra) Continued PREVENT A TIVE MAINTENANCE SCHEDULE Item How Often How To Fuel tank Flush every 150-200 hours See Storage above. of operation or as needed. Air output and Replace every 500 hours of See Air Output, Air Intake , lint fi lters operation ...

  • Master Lock B100 - page 9

    9 100743 Continued Item How Often How To Spark plug Clean and regap every 600 See Spark Plug , pages 12 and 13. hours operation or replace as needed. Fan blades Clean every season or as needed. See Fan , page 19. Motor Not required/permanently lubricated TR OUBLE- SHOO TING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, ...

  • Master Lock B100 - page 10

    100743 10 150 SHELL REMOVAL EA/EB Euro PV 020 Upper Shell Fan Guard Figure 12 - Fuel Filter Removal, 30/70,000 BTU/Hr Models Figure 11 - Upper Shell Removal, 150,000 BTU/Hr Model Figure 9 - Upper Shell Removal, 30/70,000 BTU/Hr Models Figure 10 - Upper Shell Removal, 90,000 BTU/Hr Model Side Cover Fuel Filter (30/70,000 BTU/Hr Models) 1. Remove sid ...

  • Master Lock B100 - page 11

    11 100743 150 FUEL FILTER REMOVAL PFA/P 043 Fuel Filter (90,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean fuel and replace in tank. 6. Atta ...

  • Master Lock B100 - page 12

    100743 12 Spark Plug (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut-driver and remove burner strap. 6. Place hex-body of spark plug into vise and tighten. 7. Remove spa ...

  • Master Lock B100 - page 13

    13 100743 Spark Plug (70/90/150,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes to .055" (1.4 mm) gap. 6. Install spark plug in burner head. 7. Attach ...

  • Master Lock B100 - page 14

    100743 14 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8). 6. Replace filter end cover. 7. Replace ...

  • Master Lock B100 - page 15

    15 100743 Nozzle (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assem- bly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using ...

  • Master Lock B100 - page 16

    100743 16 Nozzle (70/90,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head ...

  • Master Lock B100 - page 17

    17 100743 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen flare nut using 3/4" open-end wrench. Push fuel tube down. 6. Remove air line hose from burner head. 7. Remove t ...

  • Master Lock B100 - page 18

    100743 18 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. If ...

  • Master Lock B100 - page 19

    19 100743 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened wi ...

  • Master Lock B100 - page 20

    100743 20 WIRING DIA GRAMS Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R Red Blue White Blue White Red Red Orange Terminal Board Motor Green/ Yellow Red Motor Start Relay Black S or 2 M or 3 L or 1 230V/50Hz Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button ...

  • Master Lock B100 - page 21

    21 100743 WIRING DIA GRAMS Blue Green/Yellow 230V/50Hz White Red Orange Terminal Board Ignitor Spark Plug Motor Green/ Yellow Brown Red Orange Figure 40 - Wiring Diagram, 30,000 BTU/Hr EEI Model Ignitor Brown Green/Yellow 230V/50Hz Spark Plug Blue White Red Red Orange Terminal Board Motor Green/ Yellow Red Motor Start Relay Black S or 2 M or 3 L or ...

  • Master Lock B100 - page 22

    100743 22 A CCESSORIES Purchase accessories from your local dealer. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 30/70,000 BTU/Hr models. STANDARD WHEELS AND HANDLE KIT - HA1206 Makes heater ...

  • Master Lock B100 - page 23

    23 100743 ILLUSTRA TED PA R T S BREAKDO WN WHEELS AND HANDLES FOR 90,000 AND 150,000 BTU/Hr MODELS KEY PART PART 90,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2205 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10-24 8 8 ...

  • Master Lock B100 - page 24

    100743 24 ILLUSTRA TED PA R T S BREAKDO WN 30,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-18 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11 12 13 42 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 35 36 37 38 39 14 10 11-1 11-2 11-3 11-4 11-5 33 34 40 41 ...

  • Master Lock B100 - page 25

    25 100743 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 30,000 BTU/Hr KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 M15823 ...

  • Master Lock B100 - page 26

    100743 26 ILLUSTRA TED PA R T S BREAKDO WN 70,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-7 18-8 18-9 18-10 18-11 18-12 18-14 18-15 18-16 18-18 18-17 18-6 PFA/P 007 MOTOR & PUMP 70 EAI/EBI 18-13 Motor and Pump Assembly BURNER HEAD 70 EAI/EBI PFA/P 018 10-1 10-2 10-3 10-4 10-5 10-7 10-6 Burner Head Assembly 1 2 4 3 5 6 7 8 10 11 12 44 14 15 16 (2) 17 ...

  • Master Lock B100 - page 27

    27 100743 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 M15823 ...

  • Master Lock B100 - page 28

    100743 28 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 (2) 17 18 19 20 25 26 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 6 21 22 23 24 45 44 27 28 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED PA R T S BREAKDO WN 90,000 BTU/Hr 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly B ...

  • Master Lock B100 - page 29

    29 100743 P ARTS LIST 90,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-61 Upper Shell 1 2 M15823-27 Screw, #10-16 x 1 ...

  • Master Lock B100 - page 30

    100743 30 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 9 23 24 25 26 27 28 29 30 31 13 32 9 32 33 34 9 35 36 37 40 41 42 43 9 45 47 9 48 44 49 50 51 32 52 6 39 38 21 53 9 54 55 46 BURNER HEAD 150 EAI/EBI PFA/P 028 ILLUSTRA TED PA R T S BREAKDO WN 150,000 BTU/Hr 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 22-9 22-10 22-11 22-12 22-13 22-14 22-15 ...

  • Master Lock B100 - page 31

    31 100743 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-58 Upper Shell 1 2 098068-01 Heat De fl ecto ...

  • Master Lock B100 - page 32

    100743 32 W ARRANTY AND REP AIR SER VICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. DESA International&ap ...

メーカー Master Lock カテゴリー Air Conditioner

Master Lock B100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- B100の取扱説明書
- Master Lockの製品カード
- パンフレット
- またはMaster Lock B100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Master Lock B100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Master Lock B100の取り付け説明書、サービスマニュアル、簡易説明書、またはMaster Lock B100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Master Lock B100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Master Lock B100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMaster Lock B100を使用するのを助ける技術的文書のことです。説明書は通常、全てのMaster Lock B100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Master Lockの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Master Lock B100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMaster Lock B100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Master Lock B100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Master Lock B100デバイスの基本機能を使うにあたってのヒント。 Master Lock B100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Master Lock B100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMaster Lock B100のメーカー/サービスへの連絡先に関する情報。

Master Lock B100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMaster Lock B100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMaster Lock B100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)