    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 908-200 Regency WarmHearth High Efficiency EPA Certified Fireplace MODEL: Z2510L W armHearth Fireplace Owners & Inst allation Manual 10/06/04 Tested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner. Homeown ...

  • Regency Wraps Z2510L - page 2

    Regency Z2510 WarmHearth 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certified by the Environmental Protection Agency of the United States. This means that it meets the strictest standards in providing you wi ...

  • Regency Wraps Z2510L - page 3

    Regency Z2510 WarmHearth 3 TABLE OF CONTENTS Safety Label Safety Label .......................................................................... 4 Installation Parts, Product Details and Options ..................................... 5 Before You Install the Regency WarmHearth ......................... 6 Dimensions and Specifications .............. ...

  • Regency Wraps Z2510L - page 4

    Regency Z2510 WarmHearth 4 Copy of Safety Label for Z2510L This is a copy of the label that accompanies each Regency WarmHearth. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review. SAFETY LABEL NOTE: Regency units are constantly being improved. Check the label on the unit and ...

  • Regency Wraps Z2510L - page 5

    Regency Z2510 WarmHearth 5 THE REGENCY WARMHEARTH 1) Optional 24 Karat Gold-plated Louvers 2) Clean Glass Air Wash System 3) High Safety Ceramic Glass 4) Optional 24 Karat Gold-plated Door 5) Andirons 6) Convection Air Inlet 7) Optional 150 CFM 2-speed Blower 8) Convection Chamber 9) Secondary Air Source 10) Primary Air Source 11) 7-inch Flue Pipe ...

  • Regency Wraps Z2510L - page 6

    Regency Z2510 WarmHearth 6 Unit Dimensions INST ALLA TION 8) NEVER leave children unattended when there is a fire burning in the fireplace. 9) Allow the fireplace to cool before servicing. Always shut off any electricity to the fire- place while working on it. This will prevent any possible electrical shock. 10) Regency is not responsible for any s ...

  • Regency Wraps Z2510L - page 7

    Regency Z2510 WarmHearth 7 Framing Specifications No Combustibles on Face of Unit Combustibles May Not Extend to Unit Face Do not notch wallboard around standoffs Clearances to Combustibles INST ALLA TION normal construction materials. The chimney requires a minimum 2 in. (50 mm) clearance. A combustible mantle (to a depth of 10 in.) may be install ...

  • Regency Wraps Z2510L - page 8

    Regency Z2510 WarmHearth 8 HEARTH EXTENSION NOTE: When the unit is raised 4 inches above the floor the Regency Hearth Extension (Part# 000-910) is not required. If you plan to raise the fireplace and hearth extension, build the plat- form assembly then position fireplace and hearth extension on top. If you are not raising the unit, check that you w ...

  • Regency Wraps Z2510L - page 9

    Regency Z2510 WarmHearth 9 Ventilated Chase Pan In Canada: Any factory built chimney listed and certified to ULC-S629. Also any of the following chimney covered by ULC-S610 or ULC S604. 1) GSW Heating Products Model JFC 2) Oliver McLeod Ltd. Model PRO-JET 3103 3) Security Chimney Ltd. Model ASHT 4) Selkirk Metalbestos Model SS 5) ICC Excel 103 HT 6 ...

  • Regency Wraps Z2510L - page 10

    Regency Z2510 WarmHearth 10 INST ALLA TION ASSEMBL Y STEPS Note: The following steps represent the normal sequence of installation. Each installation is unique, howev- er, and might require different steps. Each step is dealt with in detail in the following pages. 1) Install stand-offs and insulation strip to the unit. See Page 10. 2) Complete Fram ...

  • Regency Wraps Z2510L - page 11

    Regency Z2510 WarmHearth 11 uous floor or platform for support and to pre- vent cold air from entering the room from under the fireplace, if against an outside wall. The fireplace may be positioned and then the framing built around it, or the framing may be constructed and the fireplace positioned into the opening. The minimum ceiling height is 7 f ...

  • Regency Wraps Z2510L - page 12

    Regency Z2510 WarmHearth 12 ular operation because the unit uses out- side air for combustion, not room air. 2 ) Multiple Terminations. When you in- stall more than one chimney in the same chase or within the same general area, we suggest that their terminations be separat- ed by at least 16 in. (410 mm) horizontally and 18 in. (460 mm) vertically. ...

  • Regency Wraps Z2510L - page 13

    Regency Z2510 WarmHearth 13 INST ALLING THE OUTSIDE AIR KIT Combustion air is fed to the firebox through a connection on the rear lower left side of the unit. A free flowing supply of air must be available to this opening at all times. Combustion air may be taken from inside the building if the local building code allows, but performance may suffer ...

  • Regency Wraps Z2510L - page 14

    Regency Z2510 WarmHearth 14 INST ALLA TION GRA VITY AIR FEED KIT OPTION The Gravity Air Feed Kit is designed to extend the heat output vent above the WarmHearth or to the front or the side. The upper louver opening is blocked off and flex duct is connected to the vent holes in the top of the unit and run to vent grills installed above the unit or t ...

  • Regency Wraps Z2510L - page 15

    Regency Z2510 WarmHearth 15 Central Heat Option Use high temperature silicone to seal the block-off plate to the unit. If necessary drill extra holes in the plate and the unit and secure with extra screws. NOTE: Make sure the block-off plate is flush and fastened tightly to the WarmHearth. Important: A tight joint between ma- sonry and the fireplac ...

  • Regency Wraps Z2510L - page 16

    Regency Z2510 WarmHearth 16 Typical Floor Register INST ALLA TION be at the top so they lie flat. Bend out the lower edge of the valve at 4 places inside the fireplace with pliers so that it can't be pulled out again. Diagram 2. 6) Connect the inlet of the blower to the outlet of the valve using 8 inch diameter metal ducting (rigid or flex). A ...

  • Regency Wraps Z2510L - page 17

    Regency Z2510 WarmHearth 17 Framing Metal Edging . . . . . . . . . . . . . . . . Extend unit past studs so it is flush with sheeting. Drill & T ap screws INST ALLA TION FINISHING THE WARMHEARTH Completing the Facing Facing materials must be thin veneer (non-self supporting facades) or self supporting facades. If you are installing a thin veneer ...

  • Regency Wraps Z2510L - page 18

    Regency Z2510 WarmHearth 18 Top View Top View INST ALLA TION Top View 4) Place side metal filler strips in between stove and framing to cover the stand-off space. Fit the strips behind "A" so that they cover the stand-offs, and will prevent mor- tar from falling through the mesh. 5) Center door arch edge, mark and drill holes. Note the to ...

  • Regency Wraps Z2510L - page 19

    Regency Z2510 WarmHearth 19 INST ALLA TION MASONR Y LINER/ BRICKS Insulated refractory panels are included to extend the life of the fireplace and help radiate heat more evenly. Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place. Insulation batt, 1 in. thick is placed above the top brick baffle. ...

  • Regency Wraps Z2510L - page 20

    Regency Z2510 WarmHearth 20 MAINTENANCE MAINTENANCE Gold Plated Doors and Louvers The optional gold electroplated finish on the doors and louvers requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Keep doors and louvers of ...

  • Regency Wraps Z2510L - page 21

    Regency Z2510 WarmHearth 21 PARTS LIST PARTS LIST - FIREBOX & BODY Part # Description Part # Description 20) 948-102 Spring Handle - Small 21) 000-198 Hearth Extension Connector 22 ) * Shell Inner Sides & Back 23 ) * Insulation - Right 24 ) * Insulation - Rear 25 ) * Insulation - Rear - 6" wide 26 ) * Insulation - Left 27 ) * Insulatio ...

  • Regency Wraps Z2510L - page 22

    Regency Z2510 WarmHearth 22 PARTS LIST PARTS LIST - BAFFLES, DOOR, OPTIONS Part # Description 1 ) 000-920 Masonry Retainer Kit (Optional) 846-911 Door Assembly- Gold 846-917 Door Assembly- Black 3 ) 846-300 Glass - Replacement 4 ) 936-243 7/8" Adhesive Tape 5 ) 846-920 Glass Retainer Clips (set of 8) 6 ) * Screw 1/4-20 x 3/8" 7 ) 948-174/ ...

  • Regency Wraps Z2510L - page 23

    Regency Z2510 WarmHearth 23 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency P ...

  • Regency Wraps Z2510L - page 24

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

メーカー Regency Wraps カテゴリー Indoor Fireplace

Regency Wraps Z2510Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Z2510Lの取扱説明書
- Regency Wrapsの製品カード
- パンフレット
- またはRegency Wraps Z2510Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Regency Wraps Z2510Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Regency Wraps Z2510Lの取り付け説明書、サービスマニュアル、簡易説明書、またはRegency Wraps Z2510Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Regency Wraps Z2510Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Regency Wraps Z2510Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRegency Wraps Z2510Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのRegency Wraps Z2510Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Regency Wrapsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Regency Wraps Z2510Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRegency Wraps Z2510Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Regency Wraps Z2510Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Regency Wraps Z2510Lデバイスの基本機能を使うにあたってのヒント。 Regency Wraps Z2510Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Regency Wraps Z2510Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRegency Wraps Z2510Lのメーカー/サービスへの連絡先に関する情報。

Regency Wraps Z2510Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRegency Wraps Z2510Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRegency Wraps Z2510Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)