Bunn CWA-APSの取扱説明書

25ページ 0.9 mb
ダウンロード

ページに移動 of 25

Summary
  • Bunn CWA-APS - page 1

    OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 10690.0001C 6/00 ©1998 Bunn-O-Matic Corporation CW A-APS,TS CWT A-APS,TS ...

  • Bunn CWA-APS - page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for either pour-over or automatic brewing. The automatic version may include a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf. W ARRANTY Bunn-O-Matic Corp. (“Bunn”) ...

  • Bunn CWA-APS - page 3

    Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. # 00656.0000 ...

  • Bunn CWA-APS - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. "A" Models require 2-wire grounded service rated 230-240 volts ac, 20 amp, single phase, 50 Hz. Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electrici ...

  • Bunn CWA-APS - page 5

    Page 5 Models CWTFA-APS & CWTFA-TS 1. Attach the flare fitting from the short piece of tubing on the flow control (supplied) to the lower water inlet fitting at the left rear of the brewer. 2. Attach the flare fitting from the short piece of tubing on the tee (supplied) to the upper water inlet fitting at the left rear side of the brewer. 3. Fl ...

  • Bunn CWA-APS - page 6

    Page 6 10690.1 063000 7. Place the "ON/OFF" switch in the “ OFF ” (lower) position after water has stopped flowing from the funnel, and let the water in the tank reheat to the proper temperature. 8. Empty the dispenser and proceed as directed: 8A. Models CWA-PS & CWA-TS: The brewer is now ready for use in accordance with the coffe ...

  • Bunn CWA-APS - page 7

    Page 7 OPERA TING CONTROLS Models CWA-APS & CWA-TS: These models function without operating controls. Models CWTA-APS, CWTFA-APS, CWTA-TS & CWTFA-TS: ON/OFF SWITCH Placing the "ON/OFF" switch in the "OFF" (lower) position stops brewing. Stopping a brew cycle after it has been started will not stop the flow of water into ...

  • Bunn CWA-APS - page 8

    Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by ...

  • Bunn CWA-APS - page 9

    Page 9 TROUBLESHOOTING (cont.) Brew cycle will not start (cont.) Water is not hot Inconsistent beverage level in dis- penser PROBABLE CAUSE REMEDY 7. Water strainer/flow control (.222 GPM)(CWTA-APS, CWTFA- APS, CWTA-TS, CWTFA-TS) 1. Tank Heater Switch 2. Limit Thermostat CAUTION - Do not eliminate or bypass limit thermostat. Use only B.O.M. replace ...

  • Bunn CWA-APS - page 10

    Page 10 TROUBLESHOOTING (cont.) Inconsistent beverage level in the dispenser (cont.) Consistently low beverage level in the dispenser Spitting or excessive steaming Dripping from sprayhead 4. Water Pressure (CWTA-APS, CWTFA-APS,CWTA-TS & CWTFA- TS) 1. Timer (CWTA-APS, CWTFA- APS, CWTA-TS & CWTFA-TS) 2. Strainer/flow Control (.222 GPM) 1. Li ...

  • Bunn CWA-APS - page 11

    Page 11 TROUBLESHOOTING (cont.) Water flows into tank continuously (ON/OFF Switch "ON") Water flows into tank continuously (ON/OFF Switch "OFF") Beverage overflows dispenser Weak beverage 1. Timer (CWTA-APS, CWTFA- APS, CWTA-TS & CWTFA-TS) 1. Solenoid Valve (CWTA-APS, CWTFA-APS, CWTA-TS & CWTFA- TS) 1. Dispenser 2. Timer ...

  • Bunn CWA-APS - page 12

    Page 12 TROUBLESHOOTING (cont.) Weak beverage (cont.) Dry coffee grounds remain in the funnel Brewer is making unusal noises Brewer is making unusal noises (CW) 5. Water Temperature 1. Funnel Loading 1. Solenoid (CWTA-APS, CWTFA- APS, CWTA-TS & CWTFA-TS) 2. Plumbing Lines 3. Water Supply 4. Tank Heater 1. Tank Heater Place an empty funnel on an ...

  • Bunn CWA-APS - page 13

    Page 13 ...

  • Bunn CWA-APS - page 14

    Page 14 SERVICE (cont.) CONTROL THERMOSTAT Location: The control thermostat is located inside the trunk on the upper left side of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Locate the blue wire on the control thermostat. 3. With a voltmeter, check the voltage across the blue wire on the control thermo ...

  • Bunn CWA-APS - page 15

    Page 15 SERVICE (cont.) LIMIT THERMOSTAT (CWTA & CWTFA) Location: The limit thermostat is located inside the rear of the hood on the tank lid. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue and black wires from the limit thermostat. 3. With an ohmmeter, check for continuity across the limit thermostat te ...

  • Bunn CWA-APS - page 16

    Page 16 ...

  • Bunn CWA-APS - page 17

    Page 17 SERVICE (cont.) SOLENOID VALVE Location: The solenoid valve is located inside the trunk on the lower center part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white/green wire and black wire from the solenoid valve. With the "ON/OFF" switch in the "ON" (upper ...

  • Bunn CWA-APS - page 18

    Page 18 SERVICE (cont.) START SWITCH P1467.40 Location: The start switch is located in the front of the hood just to the right of center. Test Procedure: 1. Disconnect the brewer from the power supply. 2. Disconnect the white/orange wire from the top switch terminal and the white/yellow wire from the bottom switch terminal. 3. Check for continuity ...

  • Bunn CWA-APS - page 19

    Page 19 ...

  • Bunn CWA-APS - page 20

    Page 20 SERVICE (cont.) TANK HEATER SWITCH P2195.40 Location: The tank heater switch is located on the rear of the brewer on the upper left side of the trunk. Test Procedure: 1. Disconnect the brewer from the power source. 2. Disconnect the black wire from the limit thermo- stat (Automatics only) or the blue wire (Pour Overs only). 3. With the tank ...

  • Bunn CWA-APS - page 21

    Page 21 13. Insert new tank heater switch through the hole in the upper left rear of the trunk and secure with switch indicator/guard bracket, hex facenut and plastic facenut. 14. Refer to Fig. 15 and reconnect the wires to the tank heater switch terminals. 15. Set tank assembly inside the hood on mounting brackets and secure with two #8-32 screws. ...

  • Bunn CWA-APS - page 22

    Page 22 FIG. 17 TIMER TERMINALS P1472 TL1 WHI/RED from ON/OFF Switch(1) TL2 RED to Terminal Block (Red Insert) TL3 WHI/ORN from Start Switch TL4 WHI/GRN from Solenoid TL5 WHI/YEL from Start Switch TIMER (Early Models) FIG. 16 TIMER P1468.40 Location: The timer is located inside the front of the trunk on the component bracket. It consists of the dia ...

  • Bunn CWA-APS - page 23

    Page 23 SERVICE (cont.) DIGITAL BREW TIMER (Late Models) P2195.40 FIG. 18 DIGITAL BREW TIMER Location: The timer is located inside the front of the trunk on the top of the component bracket. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect ...

  • Bunn CWA-APS - page 24

    Page 24 TL1 WHI/RED from ON/OFF Switch(1) TL2 RED to T erminal Block (Red Insert) TL3 WHI/ORN from Start Switch TL4 WHI/GRN from Solenoid TL5 WHI/YEL from Start Switch FIG. 19 DIGIT AL TIMER WIRING P2037 SERVICE (cont.) DIGITAL BREW TIMER (Late Models)(cont.) T imer Setting: NOTE: Prior to setting or modifying volumes, check that the brewer is conn ...

  • Bunn CWA-APS - page 25

    Page 25 ...

メーカー Bunn カテゴリー Coffeemaker

Bunn CWA-APSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CWA-APSの取扱説明書
- Bunnの製品カード
- パンフレット
- またはBunn CWA-APSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bunn CWA-APSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bunn CWA-APSの取り付け説明書、サービスマニュアル、簡易説明書、またはBunn CWA-APSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bunn CWA-APSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bunn CWA-APSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBunn CWA-APSを使用するのを助ける技術的文書のことです。説明書は通常、全てのBunn CWA-APSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bunnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bunn CWA-APSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBunn CWA-APSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bunn CWA-APSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bunn CWA-APSデバイスの基本機能を使うにあたってのヒント。 Bunn CWA-APSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bunn CWA-APSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBunn CWA-APSのメーカー/サービスへの連絡先に関する情報。

Bunn CWA-APSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBunn CWA-APSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBunn CWA-APSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)