Napoleon Fireplaces GDS26Nの取扱説明書

32ページ 4.21 mb
ダウンロード

ページに移動 of 32

Summary
  • Napoleon Fireplaces GDS26N - page 1

    1 W415-0607 / A / 01.18.08 $10.00 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: ANSI Z21.88 • CSA 2.33 FOR VENTED GAS FIREPLACE HEA TERS. INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca GDS ...

  • Napoleon Fireplaces GDS26N - page 2

    2 W415-0607 / A / 01.18.08 • Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove. • Clothing or other fl ammable material ...

  • Napoleon Fireplaces GDS26N - page 3

    3 W415-0607 / A / 01.18.08 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Cer tifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and tes ...

  • Napoleon Fireplaces GDS26N - page 4

    4 W415-0607 / A / 01.18.08 FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST- FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. When ...

  • Napoleon Fireplaces GDS26N - page 5

    5 W415-0607 / A / 01.18.08 35 1 / 2 ” 37” 18 1 / 8 ” 23 5 / 8 ” 4” DIA. 7” DIA. GAS LINE ACCESS ELECTRICAL ACCESS 29 1 / 8 ” DIMENSIONS FIGURE 1a VENTING VENTING LENGTHS AND AIR TERMINAL L OCA TIONS Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components. Minimum and maximum vent le ...

  • Napoleon Fireplaces GDS26N - page 6

    6 W415-0607 / A / 01.18.08 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM TYPICAL VENT INST ALLA TIONS FIGURE 2a FIGURE 3a * Refer to "V enting" Section The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset. In this case zero rise is acceptable. S ...

  • Napoleon Fireplaces GDS26N - page 7

    7 W415-0607 / A / 01.18.08 FIGURE 6 MINIMUM AIR TERMINAL L OCA TION CLEARANCES ...

  • Napoleon Fireplaces GDS26N - page 8

    8 W415-0607 / A / 01.18.08 VENTING APPLICA TION FL O W CHART STOVE VENT EXIT REAR EXIT TOP EXIT Horizontal T ermination V ertical T ermination V ertical T ermination V ertical rise is equal to or greater than the horizontal run V ertical rise is less than horizontal run Horizontal run + verti- cal rise to maximum of 40 feet Horizontal run + verti- ...

  • Napoleon Fireplaces GDS26N - page 9

    9 W415-0607 / A / 01.18.08 90° 90° 90° H 1 V 2 H 2 V 1 Simple venting con fi guration (only one 90° elbow) For vent con fi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet Example 1: V 1 = 3 ft V 2 = 8 ft V T = V 1 + V 2 = 3 + 8 = 1 1 ft H 1 = 2.5 ft H 2 ...

  • Napoleon Fireplaces GDS26N - page 10

    10 W415-0607 / A / 01.18.08 V 2 90° H 3 H 1 90° H 2 H 1 V 1 Simple venting con fi guration (only one 90° elbow) Example 2: V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H T < 4.2 V T ...

  • Napoleon Fireplaces GDS26N - page 11

    11 W415-0607 / A / 01.18.08 See graph to determine the required vertical rise V T for the required horizontal run H T For vent con fi gurations requiring more than two 90° elbows the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet HORIZONT AL VENT RUN PLUS OFFSETS IN FEET H T Example 4: FIGURE 12 The shaded ...

  • Napoleon Fireplaces GDS26N - page 12

    12 W415-0607 / A / 01.18.08 V 1 V 2 90° 45° 90° 90° Simple venting con fi guration (only two 90° elbows) Example 5: V 1 = 4 ft V 2 = 1.5 ft V T = V 1 + V 2 = 4 + 1.5 = 5.5 ft H 1 = 2 ft H 2 = 1 ft H 3 = 1 ft H 4 = 1.5 ft H R = H 1 + H 2 + H 3 + H 4 = 2 + 1 + 1 + 1.5 = 5.5 ft H O = .03(four 90° elbows + one 45° elbow - 90°) = .03(90 + 90 + ...

  • Napoleon Fireplaces GDS26N - page 13

    13 W415-0607 / A / 01.18.08 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . Example 6: V 1 = 5 ft V 2 = 6 ft V 3 = 10 ft V T = V 1 + V 2 + V 3 = 5 + 6 + 10 = 21 ft H 1 = 8 ft H 2 = 2.5 ft H R = H 1 + H 2 = 8 + 2.5 = 10.5 ft H O = .03 (fo ...

  • Napoleon Fireplaces GDS26N - page 14

    14 W415-0607 / A / 01.18.08 VERTICAL THR OUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-linear fl exible vent system running the full length of a masonry chimney . The fl exible vent pipe accommodates any contours of a masonry chimney , however , it is necessary to keep the fl exible vent pipe as straight as poss ...

  • Napoleon Fireplaces GDS26N - page 15

    15 W415-0607 / A / 01.18.08 REAR EXIT CONVERSION FIGURE 19 4” Gasket 7” Cover Plate 7” Gasket 4” Gasket 4” Collar 7” Gasket 7” Collar Outer T op 4” Cover Plate In order to convert the venting con fi guration from a top exit to a rear exit , remove components as illustrated: When reinstalling in the alternate position: Check gaskets ...

  • Napoleon Fireplaces GDS26N - page 16

    16 W415-0607 / A / 01.18.08 1. Determine the air terminal location, cut and frame a 9" square opening in the ceiling and the roof to provide the minimum 1" clearance between the vent pipe / liner and any combustible material. T ry to center the vent pipe location midway between two joists to prevent having to cut them. Use a plumb bob to ...

  • Napoleon Fireplaces GDS26N - page 17

    17 W415-0607 / A / 01.18.08 SCREWS & W ASHERS 4" COUPLER SELF DRILLING #8x1/2" 7" RIGID VENT PIPE SEALANT HIGH TEMPERA TURE 4" FLEXIBLE VENT PIPE 7" RIGID VENT PIPE 1. Attach the telescopic sleeve to the last section of 7" rigid vent pipe. Secure with screws and high temperature sealant W573-0002 (not supplied). 2. ...

  • Napoleon Fireplaces GDS26N - page 18

    18 W415-0607 / A / 01.18.08 RESTRICTING VERTICAL VENTS V ertical termination installations exiting either from the rear or the top flue collar of the stove may display a very active flame. If this appearance is not desirable, the vent exit must be restricted to reduce the velocity of the exhaust gases, thus slowing down the flame pattern and creati ...

  • Napoleon Fireplaces GDS26N - page 19

    19 W415-0607 / A / 01.18.08 FIGURE 30 FIGURE 31 RESTRICTOR PLA TE 1. Remove the front and the door from the stove. 2. Remove the screws securing the baf fl e plate. Figure 31 . Note: The baf fl e rests on two screws that are attached to the back of the fi rebox. 3. Using the screws supplied, attach the restrictor plate as show in Figure 31 . 4. ...

  • Napoleon Fireplaces GDS26N - page 20

    20 W415-0607 / A / 01.18.08 FIGURE 34 MINIMUM MANTEL, SHELF OR CEILING CLEARANCES 1” 2” 47 1 / 2 ” 35 1 / 2 ” 5” BRICK COMBUSTIBLE NON-COMBUSTIBLE 29 1 / 8 ” MINIMUM PLUS RISE * 0” IF NON-COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE. 12” MANTEL, SHELF , OR CEILING REAR EXIT T OP EXIT * HORIZONT AL VENT SECTIONS: A minimum c ...

  • Napoleon Fireplaces GDS26N - page 21

    21 W415-0607 / A / 01.18.08 BL O WER INST ALLA TION ELECTRICAL INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United States. ...

  • Napoleon Fireplaces GDS26N - page 22

    22 W415-0607 / A / 01.18.08 90° FINISHING GLASS DOOR INST ALLA TION AND REMO V AL 1. Lift the top cast piece off of the unit. 2. Pull handle forward and rotate 90º to unlatch the door . Figure 41a. 3. Lift door straight up to remove. Figure 41b. FIGURE41a LOGO PLA CEMENT LOGO 1/2” 1/2” Remove the backing from the logo and position onto the co ...

  • Napoleon Fireplaces GDS26N - page 23

    23 W415-0607 / A / 01.18.08 1. Place the rear log as shown, ensuring the holes on the underside are placed onto the 2 pins of the log support. In order to assemble the log set, the glass door must be removed, see Glass Door Installation and Removal in the FINISHING section of this manual. LOG PLA CEMENT BRACKET FIGURE 45a-d 3. Place the center log ...

  • Napoleon Fireplaces GDS26N - page 24

    24 W415-0607 / A / 01.18.08 FIGURE 46 B A TTERY H OLDER G AS V AL VE P ILOT A SSEMBL Y I GNITION M ODULE P ILOT G AS L INE Orange (I) [through independent conduit] Yellow (S) [through Gas line conduit] AC A DAPTOR B A TTERY R ELA Y Red (3 Volt) Red Black W IRE H ARNESS N OTE : W IRE T AGS ARE BRACKETED Brown (SWI) Black (-) Red (+) Green x2 (TH) Or ...

  • Napoleon Fireplaces GDS26N - page 25

    25 W415-0607 / A / 01.18.08 1. ST OP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE W ALL SWITCH T O OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER TO THE STOVE AND REMOVE BA TTERIES. 4. THIS ST OVE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMA TICALL Y LIGHTS THE PILOT . DO NOT TR Y TO LIGHT THE PILOT BY HAND. 5. TURN MANUAL SH ...

  • Napoleon Fireplaces GDS26N - page 26

    26 W415-0607 / A / 01.18.08 NOTE: Check and adjust, if necessary , the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. T urn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open fl ame. 8. Replace the log set. Then light the pilot and main burner to ensure t ...

  • Napoleon Fireplaces GDS26N - page 27

    27 W415-0607 / A / 01.18.08 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® d ealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER OF STOVE 2. I NST ALLATION DA TE OF STOVE 3. P ...

  • Napoleon Fireplaces GDS26N - page 28

    28 W415-0607 / A / 01.18.08 ATTE NTION-C HAUD CAUTION - HOT 27 44 35 18 6 7 46 17 5 11 1 3 2 23 8 26 29 31 32 34 34 28 34 25 24 33 41 38 37 40 39 21 16 4 ...

  • Napoleon Fireplaces GDS26N - page 29

    29 W415-0607 / A / 01.18.08 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object. T urn the ON/OFF switch to ...

  • Napoleon Fireplaces GDS26N - page 30

    30 W415-0607 / A / 01.18.08 Flames are very ag- gressive. - V enting action is too great. T ighten door clamps Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame. - Blockage in vent. Remove blockage. In really cold conditions, ice buildup may occur on the termin ...

  • Napoleon Fireplaces GDS26N - page 31

    31 W415-0607 / A / 01.18.08 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name ...

  • Napoleon Fireplaces GDS26N - page 32

    32 W415-0607 / A / 01.18.08 NO TES ...

メーカー Napoleon Fireplaces カテゴリー Indoor Fireplace

Napoleon Fireplaces GDS26Nのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GDS26Nの取扱説明書
- Napoleon Fireplacesの製品カード
- パンフレット
- またはNapoleon Fireplaces GDS26Nの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napoleon Fireplaces GDS26Nの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napoleon Fireplaces GDS26Nの取り付け説明書、サービスマニュアル、簡易説明書、またはNapoleon Fireplaces GDS26Nのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napoleon Fireplaces GDS26Nの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Napoleon Fireplaces GDS26Nデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapoleon Fireplaces GDS26Nを使用するのを助ける技術的文書のことです。説明書は通常、全てのNapoleon Fireplaces GDS26Nユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napoleon Fireplacesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napoleon Fireplaces GDS26Nの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapoleon Fireplaces GDS26Nの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napoleon Fireplaces GDS26Nに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napoleon Fireplaces GDS26Nデバイスの基本機能を使うにあたってのヒント。 Napoleon Fireplaces GDS26Nのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napoleon Fireplaces GDS26Nに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapoleon Fireplaces GDS26Nのメーカー/サービスへの連絡先に関する情報。

Napoleon Fireplaces GDS26Nについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapoleon Fireplaces GDS26Nの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapoleon Fireplaces GDS26Nで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)