Emerson Process Management 3500 Transmitterの取扱説明書

12ページ 0.32 mb
ダウンロード

ページに移動 of 12

Summary
  • Emerson Process Management 3500 Transmitter - page 1

    Micro Motion TM Model 3500 T ransmitter (9-wire) or Model 3300 P eripheral Inst allation Inst ructi ons f or Rac k-Mount Quick Refer ence Guide P/N 3300 995, Rev . C Apr il 2003 For online t echnical sup por t, use the EXPER T 2 ™ sys tem at www .ex per t2.com. T o speak to a customer service representati v e, call t he support center ne arest y ...

  • Emerson Process Management 3500 Transmitter - page 2

    1 BEFORE YOU BEGIN This qui ck ref erence gui de e xplains basic install ation guideli nes for mounting the Micr o Motion ® Mode l 3300 /3500 a pplicati ons plat form i n a 19-inch (486,2 mm) rac k. For info rmat ion on I .S. a pplic ation s, re fer to M icro Motio n A T EX, U L, or CSA inst alla tion inst ruction s. F or complet e instruc tions a ...

  • Emerson Process Management 3500 Transmitter - page 3

    2 Europ ean instal lations This Mi cro Motion p roduct compl ies with all a pplicabl e European direc tives when p rope rly i nstal led in acco rdan ce wi th the inst ructi ons in this q uick r efe rence guide . Re fer to t he EC decla rat ion of confo rmit y for direc tives that ap ply to this prod uct. The EC decl aration o f conf ormity , wit h ...

  • Emerson Process Management 3500 Transmitter - page 4

    3 Figure 1 . Space requ irement s for prop er vent ilatio n Dimensions The Model 330 0/3500 h as the follo wing di mension s (see Fig ure 2, page 4): • Height: 128 mm (3 U or 3 HE) • W idt h: 142 mm (28 HP or 28 TE) • Depth: 16 0 mm The Model 330 0/3500 c onforms to DIN stan dard 41494, P art 5 (IEC 297- 3) for 19- inch (486,2 mm) racks . Up ...

  • Emerson Process Management 3500 Transmitter - page 5

    4 Figure 2 . Dimensions for moun ting in r ack Flowmeter cabl e lengths Maximum cable length fr om the s ensor to t he Model 3500 trans mitter i s 1000 feet (300 meter s). If you ar e insta lling the Model 330 0 applica tions per ipher al in comb inat ion w ith a tr ans mitte r , the ma xim um cab le le ngth f rom t he transmi tter’ s freque nc y ...

  • Emerson Process Management 3500 Transmitter - page 6

    5 STEP 2. Instal ling g uide rail s and wir ing co nnectors Guide rai ls Positi ons of g uide r ails and wi ring conne ctors are indi cated in Figure 3, page 6. Centers o f guide ra ils s hould be 27 HP (27 TE) a part, for exa mple, at 1 HP (TE) and 28 HP (TE). Wiring co nnectors The a pplic atio ns pl atform is sh ippe d with a so lder-tail or scr ...

  • Emerson Process Management 3500 Transmitter - page 7

    6 Figure 3 . Positi ons of g uide rail s and wir ing connec tors STEP 3. Instal ling the Mod el 3300/ 3500 in the ra ck 1. Align th e Model 33 00/3500 with the gui de ra ils. 2. Slide t he Model 3 300/3500 in to the rack. Make sure t he pin s on the back pane l mak e conta ct with t he wiring c onnectors . 3. T ight en the supplied capti ve scre ws ...

  • Emerson Process Management 3500 Transmitter - page 8

    7 STEP 4. Connecti ng input an d output wiring Connect i nput an d output wir ing to t he appropri ate ter minals on the input/ output wir ing conn ector , which is t he far right con nector . Refer to T able 1 and to t he car d that is inser ted in to the sl ee v e on the top pan el (shown in F igure 4). • Use 24 to 1 6 A WG (0,25 to 1,5 mm 2 ) ...

  • Emerson Process Management 3500 Transmitter - page 9

    8 1. Identi fy the components s ho wn in Figure 5. Figure 5 . Sensor ca ble to Model 3500 2. Prepare the ca ble accor ding t o the in structi ons in Micro Mot ion’ s 9-W ir e Flowmeter Cabl e Pr eparation and Inst allati on Guide . 3. Ensure t hat th e cable ha s 360° s hielding , conti nuous from t he transmi tter to the sensor ’ s junctio n ...

  • Emerson Process Management 3500 Transmitter - page 10

    9 5. At the t ransmit ter: a. Con nect t he col or- coded wi res to the appro priat e termi nals. T o identi fy the termin als, ref er to Figur e 5, pag e 8. No bar e wires should r emain e xposed. b . If usi ng shie lded or ar mored ca ble, co nnect the cable b raid to t he rear st ud, as d escri bed in Micro Moti on’ s 9-W ire Flow meter Cable ...

  • Emerson Process Management 3500 Transmitter - page 11

    10 Figure 6 . Power suppl y wiri ng terminal s P ower supply wiring term inals T e rmi nal designa tions for AC power T e rmi nal designa tions for DC power ...

  • Emerson Process Management 3500 Transmitter - page 12

    Micro Motion TM Micro M otion E urope Emerson Process Mana gement Wiltonstraat 30 3905 KW V eenend aal The Netherlands T +31 (0) 318 495 670 F +31 (0) 318 495 689 Micr o Motion U nit ed Kingdom Emerson Process Mana gement Limited Horsfield W a y Bredbury I ndustrial Estate Stockpor t SK6 2SU U .K. T 0800 966 180 F 0800 966 181 Micro Mo tion Japan E ...

メーカー Emerson Process Management カテゴリー Satellite Radio

Emerson Process Management 3500 Transmitterのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3500 Transmitterの取扱説明書
- Emerson Process Managementの製品カード
- パンフレット
- またはEmerson Process Management 3500 Transmitterの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson Process Management 3500 Transmitterの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson Process Management 3500 Transmitterの取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson Process Management 3500 Transmitterのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson Process Management 3500 Transmitterの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Emerson Process Management 3500 Transmitterデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson Process Management 3500 Transmitterを使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson Process Management 3500 Transmitterユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emerson Process Managementの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson Process Management 3500 Transmitterの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson Process Management 3500 Transmitterの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson Process Management 3500 Transmitterに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson Process Management 3500 Transmitterデバイスの基本機能を使うにあたってのヒント。 Emerson Process Management 3500 Transmitterのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson Process Management 3500 Transmitterに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson Process Management 3500 Transmitterのメーカー/サービスへの連絡先に関する情報。

Emerson Process Management 3500 Transmitterについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson Process Management 3500 Transmitterの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson Process Management 3500 Transmitterで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)