  • Dynacord DPA 4410 - page 1

    DPA 4410 POWER AMPLIFIER Features • 4 x 100 W output capacity • off ground potential 100 V outputs (internally configurable to 70 V/50 V or 4 ohms) • all outputs are protected against floating (no load) and short-circuit • mains supply 115/230 V AC or battery operation 24 V DC • mains switch 115/230 V • REMOTE CONTROL start with STANDBY ...

  • Dynacord DPA 4410 - page 2

    The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to ale ...

  • Dynacord DPA 4410 - page 3

    INDICATORS, CONTROLS AND CONNECTIONS 1 LED meters 2 CLIP indicator 3 TEST button for checking and reset 4 STANDBY indicator 5 PROTECT indicator 6 GROUND FAULT indicator 7 READY indicator 8 air inlets 9 POWER on switch 10 AC MAINS INPUT connector 11 mains fuse 12 VOLTAGE SELECTOR switch 13 LEVEL 1- 4 input level controls 14 INPUT 1- 4 XLR-type conne ...

  • Dynacord DPA 4410 - page 4

    TABLE OF CONTENTS FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 INDICATORS, CONTROLS AND CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 19 1. GENERAL NOTES . . . . . ...

  • Dynacord DPA 4410 - page 5

    1. GENERAL NOTES The amplifier DPA 4410 has been specially designed to ensure durable performance and rel iable operation of sound reinforcement systems with several independent speaker circuits. The DPA 4410 is best suited for call and message transmission installations, alert systems, and for gene ral music applications in industrial enterprises, ...

  • Dynacord DPA 4410 - page 6

    4. INPUTS 1 - 4 The inputs 1 - 4 (14) are electronically balanced. With a sensitivity of 775 mV = 0 dB, t hey are meant for the connection of common control pre-amplifiers. In case off ground potential inputs are needed, the amplifier inputs are prepared to be retrofitted with input transformers of the type NRS 9 0208 (per input). Using the ROUTING ...

  • Dynacord DPA 4410 - page 7

    5.2 POWER OUTPUT with 100 V speaker systems The use of speaker systems with a 100 V matching transformer is recommended to reduce the lack in performance when the distance between amplifier and speaker systems exceeds 50 m. This m ethod also offers an easy way of output power distribution. The total power consumption of the max imum amount of the c ...

  • Dynacord DPA 4410 - page 8

    5.4 POWER OUTPUT 100 V with double output capacity If the output power of one output is not sufficient to feed all cabinets that are incorpor ated within a speaker network and it is not possible to divide the speaker chain, doubling the output power can be achieved by coupling the outputs of two DPA 4410. In that case the amplifier inputs are paral ...

  • Dynacord DPA 4410 - page 9

    Diagram 6 Pin-assignment of the REMOTE CONTROL D-Sub connector 6. METERING The green LED indicator (1) permits the continuous monitoring of the output level, provid ing the possibility to prevent the speaker systems from overload situations and damaging. When during progra m peaks the red CLIP LED (2) lights briefly, the maximum distortion-free out ...

  • Dynacord DPA 4410 - page 10

    Diagram 7 Changing the output transformer’s 354030 output voltage 9. ADDITIONAL FUNCTIONS AND FEATURES 9.1 NRS 90206 pilot tone surveillance Using the extension kit NRS 90206, the amplifier channels are automatically and continuous ly monitored. This is achieved by sending an ultra low-level 19 kHz pilot tone through the device. It enters the sig ...

  • Dynacord DPA 4410 - page 11

    Checking the functioning: With built-in NRS 90206 and operational amplifier, the READY indicators (7) have to be lit. Use the TEST button (3) to check and reset the pilot function. When keeping the TEST button pressed, the 19 kHz oscillator is switched off, the READY indicators go out, and the READY fault relay is being reset. After approximately 3 ...

  • Dynacord DPA 4410 - page 12

    Diagram 9 Printed circuit board 81330.1 with inserted input transformers NRS90208 10. INCORPORATION INTO 19" FLIGHTCASES OR 19" RACK SYSTEMS Note Do not operate the DPA 4410 without its enclosure or without parts of the enclosure. When incorporating the DPA 4410 into a 19" flightcase or 19" rack system make sure, that ther e is ...

  • Dynacord DPA 4410 - page 13

    Diagram 10 printed circuit board 85264.2 with inserted DC fuses F502 and F507 Changing the fuses F502 and F503: The battery fuses F 502 and F503 are located on the printed circuit board 85264.2, behind t he AMP battery connections. In case they need to be exchanged, the top cover plate (see also parag raph 8) and the rear cover plate of the applian ...

  • Dynacord DPA 4410 - page 14

    12. SPECIFICATIONS OF THE DPA 4410 Mains supply: Voltage: 115 V / 230 V~ AC, ±10 Frequency: 50 - 60 Protection class: I mains supply Umains [V] Imains [A] Pmains [VA] Pmains [W] Pout [W] Pv [W] floating normal operation (-10 dB) alert (-3 dB) normal operation 230 230 230 230 0.27 1.64 3.25 4.39 62 377 748 1010 35 275 585 815 0 40 200 400 35 235 38 ...

  • Dynacord DPA 4410 - page 15

    Monitor output characteristics: unbalanced Nominal output voltage 2 V = +8.2 dBu Nominal load impedance 600 ohms Overall frequency response 60 Hz … 20 kHz Environmental temperature +5° C … +40° C Technical regulations: This appliance is in accordance with the following regulations: EN 50081-1, EN 50082-1, EN 60065 Dimensions (W x H x D) 19&qu ...

メーカー Dynacord カテゴリー Car Amplifier

Dynacord DPA 4410のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DPA 4410の取扱説明書
- Dynacordの製品カード
- パンフレット
- またはDynacord DPA 4410の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Dynacord DPA 4410の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Dynacord DPA 4410の取り付け説明書、サービスマニュアル、簡易説明書、またはDynacord DPA 4410のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Dynacord DPA 4410の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Dynacord DPA 4410デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDynacord DPA 4410を使用するのを助ける技術的文書のことです。説明書は通常、全てのDynacord DPA 4410ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Dynacordの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Dynacord DPA 4410の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDynacord DPA 4410の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Dynacord DPA 4410に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Dynacord DPA 4410デバイスの基本機能を使うにあたってのヒント。 Dynacord DPA 4410のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Dynacord DPA 4410に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDynacord DPA 4410のメーカー/サービスへの連絡先に関する情報。

Dynacord DPA 4410についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDynacord DPA 4410の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDynacord DPA 4410で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)