  • Napco Security Technologies 825 - page 1

    0 1880, NAPCO OPERATING GUIDE FOR YOUR MAGNUM ALERT-825/ MAGNUM ALERT-825HS SECURITY SYSTEM NAPCO ...

  • Napco Security Technologies 825 - page 2

    Please read this guide thoroughly to familiarize yourself with your new security system. Keep this booklet handy for future reference. Note especially the ALARM PLAN on page 15. Your alarm specialist will help you fill it out and explain the various features and operating procedures for your new Magnum Alert-825/825HS. NOTICE You’ll probably find ...

  • Napco Security Technologies 825 - page 3

    Abort Delay A delay period that allows the system to be reset before it reports to a central station. Alarm Plan ldentifies the areas of your premises pro- tected by each zone of protection and lists zone features. (See page 15) Ambush Code A one or two-digit code used before an arm/ disarm code that causes a silent report to be sent to a central s ...

  • Napco Security Technologies 825 - page 4

    lndicator Lights ARMED/MEMORY (Red) l Steady- system is armed. l Flashes - alarm condition. Flashes indicate the number of zone(s) which were violated. (see page 5, Key 2) STATUS (Green) l Steady - system is disarmed, all zones okay. l Flashes - a non-24 hour zone is in trouble. Flashes indicate the number of the zone(s) that are in trouble. Note: ...

  • Napco Security Technologies 825 - page 5

    Keys NOTICE:Keys1 , 2,3,4,5,9 and S must be held down for 2 seconds (until mini-sounder beeps) to per- form their desianated ‘Hold- Down " (“Key”) functions. Key 1: TEST Momentarily sounds the burglar alarm from the battery. If no alarm is heard, or if it is weak, the battery may need replacing. Use this test weekly. (To perform this fun ...

  • Napco Security Technologies 825 - page 6

    Your Magnum Alert-825/825HS Security System has three basic components: 1. Zones Your system is capable of monitoring up to six separate areas of your premises, including Am- bush/Panic and Auxiliary zones. Each zone is an independent cir- cuit that protects a specific area of your premises. For example: your alarm specialist may have set aside a z ...

  • Napco Security Technologies 825 - page 7

    The Digit-Key Keypad All security system operations are carried out at the keypad. Each key hasaspecialfunction o f its own (see “CONTROLS” page 5) plus the ability to arm and disarm the system when they are used in a preselected combination (codes). Personal ( Arm/Disarm) Codes You can choose up to4 four-digit codes which will allow you to arm ...

  • Napco Security Technologies 825 - page 8

    Checking AC Power If the three lights of your keypad are blinking slowly, you have lost AC power. Check to see if there has been a general power outage, or if the Control Center’s trans- former is disconnected. If you must operate without AC power, press Key9 to stop the lights from blink- ing. Next, test your standby battery by pressing Key 1. I ...

  • Napco Security Technologies 825 - page 9

    If trouble is encountered on a zone programmed as a Priority- with-Bypass Zone however, enter your code to silence th e Mini- Sounder and disarm; hold down Reset Key 9 until it beeps (this will bypass the alarm condition); then enter your code to rearm. Disarming When You Return When you enter through the exit/ entry door, the Mini-Sounder will com ...

  • Napco Security Technologies 825 - page 10

    Arming Wlth Selective Zone Shunting Your alarm specialist may have opted for one or more zones that can be selectively shunted (removed) from the system. Since a shunted zone cannot cause an alarm, you may wish to use this feature to turn OFF the interior areas while arming, and keeping your perimeter zones (windows, doors, etc.) active. To arm, ch ...

  • Napco Security Technologies 825 - page 11

    Your Alarm Specialist may have programmed your security system to be monitore d by a central station. The built-in digital communicator can transmit emergency signals to the central station 24 hours a day. EMERGENCY SERVICES (Police, Medical Etc) MONITORS YOUR SYSTEM 24 HOURS PR PREMISES ALERT-825/825HS COMMUNICATOR 11 ...

  • Napco Security Technologies 825 - page 12

    Abort Delay Note which zones on your alarm plan have abort delay. This is a delay that enables you to reset the system before a zone condition report is sent to the central station. Non-24 hour zone reports are aborted by arming and then disarm- ing. 24 hour zones, however, must first be repaired. Opening and Closing Reporting An optional feature t ...

  • Napco Security Technologies 825 - page 13

    The following information is applicable only where local ordinance permits use of your alarm Control Center for fire detection Controlling Your Fire Circuit If your alarm specialist installed smoke detectors or heat sensing thermostats, you have 24 hour fire protection. This optional Fire Pro- tection Zone is always active, even though your system ...

  • Napco Security Technologies 825 - page 14

    Even with the most advanced fire alarm system, adequate protection requires an escape plan. To pre- pare your plan: Draw floorplans of your building. Show two exit s - a front or back door and a window from each room. (Make sure the window works. You may need a special fire escape ladder if the window is high up.) Write down your outside meeting pl ...

  • Napco Security Technologies 825 - page 15

    Zone Area Protected Zone Features Contacts (doom, wlndows, etc.) 1 6 Central Station (Optional) Service Person Telephone Telephone 15 ...

メーカー Napco Security Technologies カテゴリー Home Security System

Napco Security Technologies 825のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 825の取扱説明書
- Napco Security Technologiesの製品カード
- パンフレット
- またはNapco Security Technologies 825の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napco Security Technologies 825の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napco Security Technologies 825の取り付け説明書、サービスマニュアル、簡易説明書、またはNapco Security Technologies 825のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napco Security Technologies 825の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Napco Security Technologies 825デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapco Security Technologies 825を使用するのを助ける技術的文書のことです。説明書は通常、全てのNapco Security Technologies 825ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napco Security Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napco Security Technologies 825の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapco Security Technologies 825の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napco Security Technologies 825に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napco Security Technologies 825デバイスの基本機能を使うにあたってのヒント。 Napco Security Technologies 825のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napco Security Technologies 825に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapco Security Technologies 825のメーカー/サービスへの連絡先に関する情報。

Napco Security Technologies 825についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapco Security Technologies 825の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapco Security Technologies 825で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)