Manual Field Controls S2000

16 pages 4.69 mb
Download

Go to site of 16

Summary
  • Field Controls S2000 - page 1

    MODELS S2000 AND S2020 FOR GAS OR OIL FORCED AIR FURNACES, HEA T PUMPS AND ELECTRIC FURNACES has been designed to be simple to Install, Operate and Maintain. Read this manual before you install the Humidifier . Parts included in the Steam Humidifier package ar e: 1. Self Piercing Saddle V alve 2. Installation Instructions and Owners Manual 3. Mount ...

  • Field Controls S2000 - page 2

    SIMPLIFIED INST ALLA TION INSTRUCTIONS DET AILED INST ALLA TION INSTRUCTIONS 1. Insulate the water reservoir . See figure 3. 2. Select the mounting location on the duct and tape on the mounting template. 3. Drill the (8) 1/8" mountings holes. 4. Cut out the humidifier opening in the duct. 5. Insert the humidifier into the opening and screw in ...

  • Field Controls S2000 - page 3

    6. W A TER SUPPL Y - Required Criteria 9. WIRING THE STEAM HUMIDIFIER 7. M O U N T I N G T H E S T E A M H U M I D I F I E R 8. STEAM OPERA TION - Required Criteria A. W A TER SUPPL Y USING THE SADDLE V AL VE FURNISHED WITH UNIT . Important! See page 14. A. INST ALLING AND WIRING THE HUMIDIST A T B. OVERFLOW & DRAIN LINES - Required Criteria In ...

  • Field Controls S2000 - page 4

    Typi ca l Furnace S2000 & S2020 Humidifier Low V oltage T erminal Block G1 R G2 H H Heat only Thermostat W R G W R Heat Only System and Steam Humidifier with standard dry contact Humidistat Dry Contact Humidistat A A FIG. 6 Factory Jumper will stay in place unless a field installed Air Proving Device is used. FIG. 8 Bryant Evolution Furnace SPS ...

  • Field Controls S2000 - page 5

    8 . 0 0 ” 6 . 00 ” 7.50” 8 . 2 5 ” 1 0 . 5 0 ” 1 1 . 6 0 ” the room needed to install the unit in a certain location. The data can also be used to determine the minimum duct size the Steam Humidifier can be inserted into. The Steam Humidifier should not obstruct more than 25% of the cross sectional area of the selected duct. For Example ...

  • Field Controls S2000 - page 6

    F o r R e p l a c e m e n t P a r t s C a l l ( 8 0 0 ) 4 4 6 - 3 1 1 0 0 9 0 2 1 A 0 1 1 8 U . S . P A T E N T N U M B E R 5 7 5 8 0 1 8 s e r i a l n u m b e r E w c 3 8 5 H i g h w a y 3 3 , E n g l i s h t o w n , N J 0 7 7 2 6 C O N T R O L S , I N C . U L ® C U S L I S T E D 1 4 1 V P O W E R D R A I N F I L L H E A T E R B L O W E R T h e r ...

  • Field Controls S2000 - page 7

    It is recommended that humidistat settings of 30-45% not be exceeded. If condensation is noticed on windows during very cold outside temperatures, the humidistat setting should be lowered. RELA TIVE HUMIDITY CHAR T The maximum recommended relative humidity for your home depends upon many factors such as outdoor air temperature, type and placement o ...

  • Field Controls S2000 - page 8

    INITIAL ST AR T -UP * SEQUENCE OF OPERA TION * SER VICE “LED” INDICA TORS 1 1. ST AR T -UP & OPERA TING SEQUENCE Once the Steam Humidifier has been installed and the w a t e r, d r a i n , h u m i d i s t a t a n d b l o w e r i n t e r l o c k connections completed, the humidifier may be started. A. Disconnect the water line. Turn on the w ...

  • Field Controls S2000 - page 9

    14. SERVICE INDICA T ORS Seven LED lamps provided on the front panel indicate the functional status of the humidifier as shown in Figure 7 below . 9 A. L. M. N. O. B. C. D. E. F . G. H. I. J. K. Unplug the power cord from the 120 volt source for S2000 (240 volt for S2020) and allow the water to cool for at least 30 minutes prior to removal. T urn o ...

  • Field Controls S2000 - page 10

    10 A. G. B. C. D. E. F . The green "Power" light does not blink off and on. 1. The S2000 is not connected to an active 120 V AC 15 Amp power source. (S2020, 240 V AC, 10 AMP). 2. Call the T echnical Support Hotline. The "HEA TER" LED does not illuminate. 1. The humidistat is not closed, calling for humidity or the humidistat is ...

  • Field Controls S2000 - page 11

    SERVICE AND REPLACEMENT P ARTS 11 ITEM 1 120 VOL T HEA TER A SSEMBL Y 240 VOL T HEA TER A SSEMBL Y 24 VOL T SOLENOID V AL VE A SSEMBL Y W A TER LEVEL PROBE A SSEMBL Y THERMISTOR PROBE A SSEMBL Y CIRCUIT BOARD A SSEMBL Y DRAIN V AL VE ASSEMBL Y T ANK BAFFLE W A TER HAMMER ARRESTER (not shown) ANODE INSULA TION KIT (not shown) 2002 2003 2007 2008 WH ...

  • Field Controls S2000 - page 12

    Figure 18 12 DRAIN COCK V AL VE "T" ADAPTER, 1/4" NPT OVERFLOW TUBE, .50 ID x 6" LG. BARBED TEE, 1/4-18 NPT TO ½ " JUMPER WIRE, 20GA. X 1.50" LONG MOLEX PLUG BLACK WIRES 18GA. X 18" LONG SOLENOID V AL VE, 24/60 V AC 2 63 0 A irp o rt Ro a d K in s t on , N C 28 5 04 P H : 2 52 . 52 2 . 30 31 FA X : 25 2 . 52 2.02 ...

  • Field Controls S2000 - page 13

    Smart Digital Humidistat Installation and Owner's Manual The 072000 is a digital humidifier control that can automatically adjust the indoor humidity set point as the outside air t em p e r a tu r e c h an g e s . T h is i n t e ll i g e n t control will maintain accurate humidity levels and a more comfortable indoor environment. The actual in ...

  • Field Controls S2000 - page 14

    Z100 A SSEMBL Y INST ALL A TION INSTRUCTIONS & OWNER'S MANUAL Z100 REPL ACEMENT INSTRUCTIONS ELECTRONIC STEAM POWER HUMIDIFIERS MODEL # S2000 AND S2020 APPLICA TION NOTE AN 131 C o p yr igh t © 2 0 1 1 Fi e ld Co n trols A l l Ri g h t s Rese rved . S U P P L E ME N T T O T H E T h e F i el d Co n trol s St e a m H u mi d i fie r no w co ...

  • Field Controls S2000 - page 15

    APPLICA TION NOTE P ART # 2009 AN 151 SC100 - P AR T # 2009 DECORA TIVE COVER S2000/S2020 STEAM HUMIDIFIER SC100 Installation Instructions P/ N 09 0 3 76 A0 15 1 R EV. A Co p yrig h t 2 01 1 © F ie l d Co n t rol s I n c. , Al l Ri g hts Re se rve d S U P P LEM E NT TO TH E ELECTR ON IC S TE A M P OWE R HU M ID IFI E RS M ODEL # S 2 0 0 0 A N D S ...

  • Field Controls S2000 - page 16

    16 Model Number:____________________Serial Number:____________________Date Code:_____________________ Date Purchased:_________________________________________________________________________________ Date Installed: __________________________________________________________________________________ Date Inspected:_____________________________________ ...

Manufacturer Field Controls Category Humidifier

Documents that we receive from a manufacturer of a Field Controls S2000 can be divided into several groups. They are, among others:
- Field Controls technical drawings
- S2000 manuals
- Field Controls product data sheets
- information booklets
- or energy labels Field Controls S2000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Field Controls S2000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Field Controls S2000, service manual, brief instructions and user manuals Field Controls S2000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Field Controls S2000.

A complete manual for the device Field Controls S2000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Field Controls S2000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Field Controls S2000.

A complete Field Controls manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Field Controls S2000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Field Controls S2000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Field Controls S2000, that we can find in the current document
3. Tips how to use the basic functions of the device Field Controls S2000 - which should help us in our first steps of using Field Controls S2000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Field Controls S2000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Field Controls S2000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Field Controls S2000?

Use the form below

If you did not solve your problem by using a manual Field Controls S2000, ask a question using the form below. If a user had a similar problem with Field Controls S2000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)