Manual SIIG 04-0373C

36 pages 0.39 mb
Download

Go to site of 36

Summary
  • SIIG 04-0373C - page 1

    1 Serial ATA PCI RAID Quick Installation Guide 04-0373C Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers. It achieves burst data transfer rates up to 150MB/s (1.5Gb/s) and supports various brands of hard disk drives with capacities greater t ...

  • SIIG 04-0373C - page 2

    2 System Requirements • Pentium ® or equivalent PC with an available PCI slot • Windows ® 98SE/ME/2000/XP (32-/64-bit)/Server 2003 (32-/64-bit)/Vista (32-/64-bit) Package Contents • Serial ATA PCI RAID board • 2 Serial ATA data cables • Dual Connector Serial ATA power cable • "Y" split power cable • Driver software and use ...

  • SIIG 04-0373C - page 3

    3 Hardware Installation General instructions for installing the card are provided below. Since the design of computer cases and motherboards vary, refer to your computer’s reference manual for further information, if needed. Static Electricity Discharge may permanently damage your system. Discharge any static electricity build up in your body by ...

  • SIIG 04-0373C - page 4

    4 2. Connect the Serial ATA hard disk drive to the system power supply using the included Serial ATA power cable . 3. Connect one end of the Serial ATA data cable to the hard disk drive. Figure 2. Hard disk drive connections 4. Attach the other end of the Serial ATA data cable to the Serial ATA connector on the Serial ATA PCI RAID . Serial ATA cabl ...

  • SIIG 04-0373C - page 5

    5 RAID Arrays RAID arrays are setup in the Serial ATA PCI RAID BIOS. Find your RAID set from the table of contents. Follow the steps in the order in which they appear. Table of Contents RAID 0 (Striping) ........................................... page 5-6 RAID 1 (Mirror) ............................................. page 6-7 Rebuilding a Failed Mi ...

  • SIIG 04-0373C - page 6

    6 6. Press Ctrl+E to exit the BIOS. 7. When asked Are you sure to exit (Y/N)? , press Y to exit and reboot. For Manual Configuration 1. As the BIOS boots press either Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set , then press Enter . 3. Select Striped , then press Enter . 4. Select Manual configurat ...

  • SIIG 04-0373C - page 7

    7 For Existing Hard Drives with Data 1. As the BIOS boots press either Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set , then press Enter . 3. At the next screen select Mirrored then press Enter . 4. Select Manual configuration , then press Enter . 5. Select the Source drive, press Enter . 6. Select t ...

  • SIIG 04-0373C - page 8

    8 3. Select Rebuild Mirror set then press Enter . 4. Select Offline rebuild then press Enter . 5. When asked Are You Sure (Y/N)? , press Y to confirm. 6. The mirror will start to rebuild. When rebuilding finishes, press Ctrl+E to exit. (Rebuilding can take 30-120 minutes depending on the size of the mirror). 7. When asked Are you sure to exit (Y/N) ...

  • SIIG 04-0373C - page 9

    9 Low Level Format Low Level Format is built into the RAID BIOS to make it more convenient to erase the entire contents of a hard disk drive, including data, drive and partition information. The Low Level Format utility works on single hard drives only, before the RAID set is configured. Driver Installation This section provides information on how ...

  • SIIG 04-0373C - page 10

    10 For An Existing Installation 1. Install the board and boot up to Windows. 2. At the Add New Hardware Wizard , click Next to continue. 3. Select Search for the best driver for your device option then click Next . 4. Insert the driver CD, check CD-ROM drive , uncheck the other check boxes, then click Next . 5. Click Next, then Finish . 6. Remove t ...

  • SIIG 04-0373C - page 11

    11 For An Existing Installation 1. Install the board and boot up to Windows. 2. At the Add New Hardware Wizard , insert the driver CD. 3 . Select Automatic search for a better driver (Recommended) , then click Next . 4. Accept the default entry then click OK . 5. Click Finish . 6. Remove the driver CD, shutdown Windows, and setup your RAID array. W ...

  • SIIG 04-0373C - page 12

    12 4. At the Windows 2000 Setup screen, press F6 . 5. When prompted press S to specify the location of the driver. 6. Insert the driver diskette, then press Enter . 7. Select Silicon Image SiI 3x12 SATARaid Controller for Windows NT 4.0 and 2000 , then press Enter . 8. Press Enter to finish driver installation, then follow the on-screen instruction ...

  • SIIG 04-0373C - page 13

    13 2. Follow Microsoft installation procedure to install Windows accordingly. 3. Restart your system when prompted by Windows installation. 4. At the Windows Setup screen, press F6 to install the driver. 5. Insert the driver diskette. Press S then press Enter . 6. Select Silicon Image SiI 3x12 SATARaid Controller for Windows XP/Server 2003/Vista an ...

  • SIIG 04-0373C - page 14

    14 64-bit Windows XP/Server 2003 For A New Installation A new installation of Windows XP/Server 2003 requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the 64bit folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID array prior to Windows installa ...

  • SIIG 04-0373C - page 15

    15 4. Click Finish , remove the driver CD, shutdown Windows, and setup your RAID array. When Windows resumes, go to SATARaid GUI on page 17 and install the RAID monitoring utility. To Verify 2000/XP/Server 2003 Installation 1. Right click My Computer , click Manage , click Device Manager . 2. Double click SCSI and RAID controllers , Silicon Image S ...

  • SIIG 04-0373C - page 16

    16 For An Existing Installation 1. Install the board and boot up Windows. 2. At the Found New Hardware window, click Locate and install the driver automatically (recommended) . 3. Insert the driver CD, click Continue . 4. Click Next , then click Close . 5. Remove the driver CD, shutdown Windows, and setup your RAID array. When Windows resumes, go t ...

  • SIIG 04-0373C - page 17

    17 SATARaid GUI The SATARaid GUI provides the user an easy way to monitor and configure your RAID array. It also offers administrative tools to save, copy, or send via E-mail the current configuration. Installing SATARaid GUI For Windows Vista 1. Place the driver CD into the CD-ROM drive. At the AutoPlay window : click Open folder to view files . I ...

  • SIIG 04-0373C - page 18

    18 For 98SE/ME/2000/XP(32-/64-bit)/Server 2003(32-/64-bit) 1. Place the driver CD into the CD-ROM drive. 2. At the Windows desktop click Start , then Run . 3. Type D:GUIJava SATARaid.exe , then click OK . Follow the on-screen instructions to complete the installation (Change D: to match your CD-ROM drive letter) 4. At the Windows desktop click St ...

  • SIIG 04-0373C - page 19

    19 Using SATARaid GUI During the installation process, the SATARaid GUI was saved in the Windows Startup folder, a small blue SATARaid logo will appear in the right-hand corner of taskbar. To launch the GUI, simply click on the icon or right click icon and choose Open . Upon launching the GUI, the the first window which identifies the computer runn ...

  • SIIG 04-0373C - page 20

    20 By selecting a specific channel the following information is reported. Selecting each different component in the configuration tree provides specific information for that component, such as the chip. ...

  • SIIG 04-0373C - page 21

    21 Selecting a specific drive reports all pertinent information to that drive, including Configuration and Disk Identification information. ...

  • SIIG 04-0373C - page 22

    22 Selecting Sets reports on active RAID sets. By selecting the specific RAID set, such as Set 1 which is a Mirrored Set, the type of RAID set, the number of members and capacity is reported. ...

  • SIIG 04-0373C - page 23

    23 The Members tab reports the device identification (corresponding with the information in the BIOS) and the state of each device. Besides reporting information, the Members tab of a Mirrored Set allows the user to remove a specific drive from that set. However, a drive cannot be removed from a stripe set as this would destroy all the data. ...

  • SIIG 04-0373C - page 24

    24 The device identification, along with the state of each device is also reported in the Members tab window. Note that when a Mirror set is first created, the state of the “destination” drive may report as Rebuild for as much as 30-90 minutes depending on the size of the disk. SMART and Configuration information, as well as Data Identification ...

  • SIIG 04-0373C - page 25

    25 Configuration Menu With the SATARaid GUI running, the small SATARaid icon should appear in the bottom right of the computer screen, next to the clock. By right-clicking on the icon and clicking Configure the user may configure SATARaid including customizing the settings for SMTP, E-mail, Notification, Event Level, Log File, Audio, Popup, TrayIco ...

  • SIIG 04-0373C - page 26

    26 E-Mail Using the E-mail tab in the Configuration Menu, the user may set the default E-mail address and subject line to where the configuration should be sent. This, however, can be overridden at the time of sending the E-mail. Notification When different types of events occur, SATARaid may be configured to send notices to assigned individual E-m ...

  • SIIG 04-0373C - page 27

    27 Event Level There are different types of E-mail notifications that may be sent which are set with the Event Level tab. The different levels are: Disabled - No event logs will be sent Informational - The following events will be sent: - Informational - Warnings - Errors Warning - The following events will be sent: - Warnings - Errors Errors - The ...

  • SIIG 04-0373C - page 28

    28 Log File The log file is used to store event information received from all the RAID drivers. The log file is a text file and can be viewed with Notepad or the SATARaid GUI. Use the Log File tab to set where the log file should be stored and the name of the file as well. Audio The user may set different audio alerts for the different levels of ev ...

  • SIIG 04-0373C - page 29

    29 Popup The popup window is a visual notification that an event occurred. The popup window can be disabled or set to popup for only certain event levels. The different levels are: Disabled - No popup will occur Informational - The popup window will be displayed for the following events: - Informational - Warnings - Errors Warning - The popup windo ...

  • SIIG 04-0373C - page 30

    30 TrayIcon and Event Table The TrayIcon sets which level of events the tray icon will blink for and the Event Table sets which level of events will show in the event table. Event Time The system will monitor the controller in a fixed time interval. Since to small of an interval may impact your computer's performance, please set the proper int ...

  • SIIG 04-0373C - page 31

    31 Menu Commands Advanced Menu Under the Advanced Menu you can create, delete, modify your RAID array, and create and delete a Spare Drive in addition to System View, Configuring SATARaid and Send Configuration via email as discussed earlier. ...

  • SIIG 04-0373C - page 32

    32 RAID Wizard Select your option, click Next and follow the on screen instructions. Options not related to your RAID array will be greyed out. RAID Management In RAID Management you can create, delete, modify your RAID array, and create and delete a Spare Drive using the RAID Wizard. ...

  • SIIG 04-0373C - page 33

    33 SATA RAID Help Menu The SATARaid Help menu gives detailed information on features and benefits and RAID functions to help you get the most out of the Serial ATA PCI RAID controller. ...

  • SIIG 04-0373C - page 34

    34 Blank Page ...

  • SIIG 04-0373C - page 35

    35 Technical Support and Warranty QUESTIONS? SIIG ’ s Online Support has answers! Simply visit our web site at www.siig.com and click Support . Our online support database is updated daily with new drivers and solutions. Answers to your questions could be just a few clicks away. You can also submit questions online and a technical support analyst ...

  • SIIG 04-0373C - page 36

    Serial ATA PCI RAID is a trademark of SIIG, Inc. SIIG and the SIIG logo are registered trademarks of SIIG, Inc. Microsoft, Windows and Windows Vista are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Other names used in this publication are for identification only and may be trademar ...

Manufacturer SIIG Category Computer Hardware

Documents that we receive from a manufacturer of a SIIG 04-0373C can be divided into several groups. They are, among others:
- SIIG technical drawings
- 04-0373C manuals
- SIIG product data sheets
- information booklets
- or energy labels SIIG 04-0373C
All of them are important, but the most important information from the point of view of use of the device are in the user manual SIIG 04-0373C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SIIG 04-0373C, service manual, brief instructions and user manuals SIIG 04-0373C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SIIG 04-0373C.

Similar manuals

A complete manual for the device SIIG 04-0373C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SIIG 04-0373C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SIIG 04-0373C.

A complete SIIG manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SIIG 04-0373C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SIIG 04-0373C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SIIG 04-0373C, that we can find in the current document
3. Tips how to use the basic functions of the device SIIG 04-0373C - which should help us in our first steps of using SIIG 04-0373C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SIIG 04-0373C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SIIG 04-0373C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SIIG 04-0373C?

Use the form below

If you did not solve your problem by using a manual SIIG 04-0373C, ask a question using the form below. If a user had a similar problem with SIIG 04-0373C it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)