    IMPOR T ANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SA VE THESE INSTRUCTIONS Installation and User's Guide ThermalFlo ™ Heat Pump ...

  • Pentair ThermalFlo - page 2

    © 2006 Pentair W ater Pool and Spa, Inc. All rights reserved. This document is subject to change without notice. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles A ve., Moorpark, CA 93021 • (805) 553-5000 T rademarks and Disclaimers .The Pentair W ater Pool and Spa logo, IntelliT ouch and EasyT ouch are registered t ...

  • Pentair ThermalFlo - page 3

    i ThermalFlo Installation and User ’ s Guide Contents Important Safety Precautions .............................................................................................. i i i Section 1: Introduction ..................................................................................................... 1 ThermalFlo Overview ................ ...

  • Pentair ThermalFlo - page 4

    ii ThermalFlo Installation and User ’ s Guide Contents, continued Section 3: Operating the ThermalFlo ............................................................................... 15 Initial Start-up Precautions ...................................................................................... 1 5 Operating the C ontroller ................. ...

  • Pentair ThermalFlo - page 5

    iii ThermalFlo Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS Codes and Standards The ThermalFlo HP heat pump is listed by ETL as complying with the latest edition of the “UL Standard for Safety for Heating and Cooling Equipment”, UL 1995 and CSA C22.2 No. 236. All Pentair W ater heat pumps must be installed in accordance with t ...

  • Pentair ThermalFlo - page 6

    iv ThermalFlo Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS (continued) Consumer Information and Safety The ThermalFlo series of heat pumps are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual and the installation codes r ...

  • Pentair ThermalFlo - page 7

    v ThermalFlo Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS (continued) Swimming Pool Energy Saving Tips It is important to note that a heat pump will not heat a pool as fast as a large gas or electric pool heater. If the pool water is allowed to cool significantly, it may take several days to return to the desired swimming temperat ...

  • Pentair ThermalFlo - page 8

    vi ThermalFlo Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS (continued) General Installation Information 1. Installation and service must be performed by a qualified installer or service agency , and must conform to all national, state, and local codes. 2. The ThermalFlo heat pump gets electrical power from an external source and p ...

  • Pentair ThermalFlo - page 9

    1 ThermalFlo Installation and User ’ s Guide Section 1 Introduction ThermalFlo Overview The ThermalFlo heat pump gets electrical power from an external source and provides a dual electronic thermostat control system for pool/spa combinations or preheat convenience. ThermalFlo HP heat pumps transfer the heat from the outside air to your pool, prov ...

  • Pentair ThermalFlo - page 10

    2 ThermalFlo Installation and User ’ s Guide General Features • Dual digital thermostats offer precise temperature control to maintain the desired separate water temperatures in pool/spa combinations without overheating or wasting energy . • Long-life corrosion resistant composite cabinet stands up to severe climates and pool chemicals. • H ...

  • Pentair ThermalFlo - page 11

    3 ThermalFlo Installation and User ’ s Guide Section 2 Installation The following general information describes how to install the ThermalFlo heat pump. Note: Before installing this product, read and follow all warning notices and instructions starting on page iii. Installing the ThermalFlo Only a qualified service person should install the Therm ...

  • Pentair ThermalFlo - page 12

    4 ThermalFlo Installation and User ’ s Guide ThermalFlo Heat Pump Dimensions 38.7" A 4.5" 9.25" 1 1.25" 32.0" 30.7" 18.0" 6.5" .5" PRODUCT SPEC LABEL PART N UMBE R SERIAL NO. CONTAINER ID ETL LISTED CONFORMS TO UL STD 1995 3044065 CERTIFIED TO CAN/CSA STD C2 2.2 NO. 236 C US ThermalFlo™ HP WATER PRES ...

  • Pentair ThermalFlo - page 13

    5 ThermalFlo Installation and User ’ s Guide Clearances All criteria given in the following sections reflect minimum clearances. However , each installation must also be evaluated, taking into account the prevailing local conditions such as proximity and height of walls, and proximity to public access areas. The heat pump must be placed to provid ...

  • Pentair ThermalFlo - page 14

    6 ThermalFlo Installation and User ’ s Guide HEA T PUMP CLAMPS HEA T PUMP CLAMPS Figure 4. Drainage and Condensation Condensation will occur from the evaporator coil while the unit is running and drain at a steady rate, usually three to five gallons per hour , depending upon ambient air temperature and humidity . The more humid the ambient condit ...

  • Pentair ThermalFlo - page 15

    7 ThermalFlo Installation and User ’ s Guide HEA T PUMP ANCHOR CLAMP AIR COIL GUARD AIR COIL BOL T ANCHOR (installer provided) HEA T PUMP BASE 1-3/8" HEX BOL T (installer provided) CONCRETE EQUIPMENT P AD Figure 5. POOL HEA TER CHEMICAL LOOP 2 LB. CHEMICAL RESIST ANT CHECK V AL VE CHEMICAL FEEDER TO POOL OR SP A POOL PUMP FROM POOL OR SP A M ...

  • Pentair ThermalFlo - page 16

    8 ThermalFlo Installation and User ’ s Guide W ater Connections at the Heat Pump T wo inch Quick Connect fittings have been installed on the water inlet and outlet connections, see Figure 7. Filtered cool water is plumbed to the inlet, located on the right side of the heat pump front panel. Heated water flows through the outlet, located on the le ...

  • Pentair ThermalFlo - page 17

    9 ThermalFlo Installation and User ’ s Guide Multiple Unit Installation Heat Pump, Heater and/or Solar Combination In certain regions of the country it may be more economical to run a heat pump during the warmer months and a gas heater during the cooler months. In some situations it may be desirable to run the heat pump in the “Chiller” mode, ...

  • Pentair ThermalFlo - page 18

    10 ThermalFlo Installation and User ’ s Guide Multiple Heat Pump Connections All plumbing on multiple heat pump installations must be done in parallel see Figures 9 and 10. An equal flow of water to each heat pump is important for optimum operation. NOTE: It may be necessary to adjust water pressure switch if a unit is installed below the water l ...

  • Pentair ThermalFlo - page 19

    11 ThermalFlo Installation and User ’ s Guide Electrical Connections W ARNING — Risk of electrical shock or electrocution. This heat pump contains wiring that carries high voltage. Contact with these wires could result in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to pr ...

  • Pentair ThermalFlo - page 20

    12 ThermalFlo Installation and User ’ s Guide Wiring Diagram 4730 73 Con tact or Comp re ssor Incoming 220 VAC Power Connecti on R C S REMO TE 10K Thermistor 1 2 3 4 5 6 Capa citor NC NO Fan Relay COM Fan Gre en Water Pres Sw Lo Re f Pres Sw Hi R e f Pr es Sw 460812, 46081 3, 46081 4, 46081 5, 46082 2, 46080 4 TBL TBR Optional Reversing Valve on ...

  • Pentair ThermalFlo - page 21

    13 ThermalFlo Installation and User ’ s Guide Relay Remote Controls Electrical wiring must be in accordance with the latest edition of the NEC (NFP A 70) in the United States and CEC (CSA 22.1) in Canada, unless local code requirements indicate otherwise. T o connect remote control equipment to the heat pump, perform the following steps: 1. Turn ...

  • Pentair ThermalFlo - page 22

    14 ThermalFlo Installation and User ’ s Guide Connecting the ThermalFlo to the IntelliT ouch ® or EasyT ouch ® Load Center T o connect the ThermalFlo cable to the Personality Board in the IntelliT ouch or EasyT ouch Load Center: 1. Turn of f the main system power before making any connections. 2. Unlatch the front door spring latche(s), and ope ...

  • Pentair ThermalFlo - page 23

    15 ThermalFlo Installation and User ’ s Guide Section 3 Operating ThermalFlo This section describes how to operate the ThermalFlo heat pump. Initial Start-up Precautions CAUTION — Do not use this heat pump if any part has been under water . Immediately call a qualified service technician to inspect the heater and replace any part of the control ...

  • Pentair ThermalFlo - page 24

    16 ThermalFlo Installation and User ’ s Guide Operating the Controller An advanced microprocessor based controller that provides a sophisticated yet simple interface to operate your heat pump for maximum efficiency and enjoyment of your pool, controls the ThermalFlo HP heat pump. It will control incoming water temperature between a minimum of 60? ...

  • Pentair ThermalFlo - page 25

    17 ThermalFlo Installation and User ’ s Guide Indicator Lights / LEDs Nine lights can be seen from the front of the control panel. Five are system indicators and four are mode indicators. These lights help the operator and service person understand the operation of the heat pump and aid in troubleshooting problems. System Indicator LEDs 1. WATER ...

  • Pentair ThermalFlo - page 26

    18 ThermalFlo Installation and User ’ s Guide Operation T emperature Setting The heat pump comes factory set at 78º F . for POOL mode and 100º F . for SP A mode. Start by selecting either the POOL or SP A mode to turn the heater on, then using the “ Up ” and “ Down ” arrows, you can set the thermostat anywhere between a minimum temperat ...

  • Pentair ThermalFlo - page 27

    19 ThermalFlo Installation and User ’ s Guide T roubleshooting The control panel contains a three digit LED display . These LEDs display temperatures, lock out status and error codes. The error codes are listed below: E D O CE M A NE S U A C 1 0 E e r u s s e r P t n a r e g i r f e R w o L. n e p o h c t i w s e r u s s e r p t n a r e g i r f e ...

  • Pentair ThermalFlo - page 28

    20 ThermalFlo Installation and User ’ s Guide W ater Pressure Switch Adjustment CAUTION — The water pressure switch should be adjusted to turn the heater off when the pump is off. Setting the switch to close at too low of a flow can damage the appliance. Adjust the switch to turn the heater off, not on. The pressure switch is preset at the fact ...

  • Pentair ThermalFlo - page 29

    21 ThermalFlo Installation and User ’ s Guide Section 4 General Maintenance W ater Chemistry Proper chemical balances are necessary for sanitary bathing conditions as well as ensuring your heat pump’ s long life. Be sure to keep your chemical and mineral concentration levels within the values indicated in T able 1. Failure to maintain proper wa ...

  • Pentair ThermalFlo - page 30

    22 ThermalFlo Installation and User ’ s Guide Spring Start-Up If your heat pump has been winterized, perform the following steps when starting the system in the Spring: 1. Uncover the heat pump and inspect the top and sides for any debris or structural problems. 2. Connect the water inlet and outlet unions located on the lower front panel of the ...

  • Pentair ThermalFlo - page 31

    23 ThermalFlo Installation and User ’ s Guide Professional Maintenance and Service The Pentair ThermalFlo Heat Pump is one of the most efficient ways to heat a pool or spa. The heat pump transfers heat from the outside air to the pool or spa water by means of an internal heat exchanger . When the fan is turned on, warm air is drawn through the R4 ...

  • Pentair ThermalFlo - page 32

    24 ThermalFlo Installation and User ’ s Guide ...

  • Pentair ThermalFlo - page 33

    25 ThermalFlo Installation and User ’ s Guide Section 5 T roubleshooting Use the following troubleshooting information to resolve possible problems with your ThermalFlo heat pump. W ARNING — RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Improperly installation will create an electrical hazard which could result in death or serious injury to pool u ...

  • Pentair ThermalFlo - page 34

    26 ThermalFlo Installation and User ’ s Guide Remote, Pool or Spa light ON. Water Pressure light ON. Thermostat light OFF . EO1 Error Unit will not run. Remote, Pool or Spa light ON. Water Pressure light ON. Thermostat light ON. Unit is cycling on & off. Remote, Pool or Spa light ON. Water Pressure light ON. Thermostat light ON. Fan is not tu ...

  • Pentair ThermalFlo - page 35

    27 ThermalFlo Installation and User ’ s Guide Compressor will not start. Fan comes on, compressor attempts to start but unit shuts all the way off (and or circuit breaker trips). Water running from the bottom of the heater when it is running. OR The heater seems to have a water leak. Heat pump does not run and control board display shows HIGH REF ...

  • Pentair ThermalFlo - page 36

    28 ThermalFlo Installation and User ’ s Guide Section 6 Replacement Parts Illustrated Parts DET AIL A SEE DET AIL A ...

  • Pentair ThermalFlo - page 37

    29 ThermalFlo Installation and User ’ s Guide Replacement Parts List Item No. Part No. Part Description 1 4704 39 NUT , 10-32 SS ACORN 2 473368 GUARD, F A N 3 4704 41 F ASTENER KIT , F AN GUARD (1 SET) 4 470289 MOTOR & ACORN NUT KIT , F A N 5 473 285 NUT , 1/4-20 SS ACORN 6 473134 TOP 7 470 159 SCREW , #10 X .75" P AN HEAD PHILLIPS, ALMO ...

  • Pentair ThermalFlo - page 38

    30 ThermalFlo Installation and User ’ s Guide Notes ...

  • Pentair ThermalFlo - page 39

    TF ...

  • Pentair ThermalFlo - page 40

    P/N 473426 Rev . C 10/19/06 ...

Manufacturer Pentair Category Heat Pump

Documents that we receive from a manufacturer of a Pentair ThermalFlo can be divided into several groups. They are, among others:
- Pentair technical drawings
- ThermalFlo manuals
- Pentair product data sheets
- information booklets
- or energy labels Pentair ThermalFlo
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pentair ThermalFlo.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pentair ThermalFlo, service manual, brief instructions and user manuals Pentair ThermalFlo. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pentair ThermalFlo.

A complete manual for the device Pentair ThermalFlo, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pentair ThermalFlo by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pentair ThermalFlo.

A complete Pentair manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pentair ThermalFlo - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pentair ThermalFlo, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pentair ThermalFlo, that we can find in the current document
3. Tips how to use the basic functions of the device Pentair ThermalFlo - which should help us in our first steps of using Pentair ThermalFlo
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pentair ThermalFlo
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pentair ThermalFlo in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pentair ThermalFlo?

Use the form below

If you did not solve your problem by using a manual Pentair ThermalFlo, ask a question using the form below. If a user had a similar problem with Pentair ThermalFlo it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)