  • Agilent Technologies 34980A - page 1

    How your 3499A/B/C T est System Benefits From Upgrading to the New 34980A Switch/Measure/Control System Application Note This application not e will describe differences and advant ages of t he new 34980A as compared to the 3499A/B/C. The 34980A Switch/Measure System masters switching, measurement, and control features by offering a superior select ...

  • Agilent Technologies 34980A - page 2

    2 List of 34980A Measurement Capabilities • T emperature measured with Thermocouples, RTDs and Thermistors • DC and AC volts • 2- and 4-wire Resistance • Frequency and Period • DC and AC current • 4 alarms for High/Low or both limits for each channel • Digital I/O • Analog outputs (DAC) The 34980A mainframe also includes f our 2-wir ...

  • Agilent Technologies 34980A - page 3

    3 Modules The 34980A implements a superior selection of switch topologies. The 34980A swit ch topologies are similar t o 3499A/B/C switch modules and include multiplex ers, matrixes, high-po w er , general purpose, and RF/micro wav e switches. Ho wev er , the 34980A modules hav e utilized the new est swit ch technology which enables a higher densit ...

  • Agilent Technologies 34980A - page 4

    4 Module T ype 34980A 3499A/B/C Multiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A 34922A 70 Ch armature 300V 1A N2266A 40 Ch reed 200V .5A 34923A 40 Ch reed 200V .5A N2270A 10 Ch 1000V 1A 34924A 70 Ch reed 80V .5 44470A 10 Ch armature 250V 2A 34925A 40 Ch FET +/-80V .5A 44470D 20 Ch armature 250V 2A General Purpose 34937A 28 C ...

  • Agilent Technologies 34980A - page 5

    5 User Interface The 34980A of fers the most modern instr ument I/O options for inter facing a controller PC wit h the switch system: GPIB, USB and L AN. All three Input/Output inter face connections come standard with the 34980A mainframe. If you choose t o modify or upgrade your test system I/O, the 34980A is system ready. Y ou can also easily co ...

  • Agilent Technologies 34980A - page 6

    6 W eb Page Interface The 34980A comes wit h a built-in detailed instr ument w eb page that allo ws you t o remot ely connect and communicate with the mainframe and installed modules. Y ou establish a L AN connection, eit her directly between t he 34980A and PC, or from the 34980A to an existing Local Area Netw ork. The instrument W eb page resides ...

  • Agilent Technologies 34980A - page 7

    7 T able 4. Command comparisons 34980A 3499A/B/C Close channel 10 on the module in slot 3 ROUT e:CLOS (@3010) [ROUT e:]CLOS (@310) Scan channels 0 through 40 on the module in slot 1 ROUT e:SCAN (@1001:1040) [ROUT e:]SCAN (@100:140) and channel(s) rat her than only three digits as the 3499A/B/C uses. Also, for t he 3499A/B/C t he [ROUT e] in the com ...

  • Agilent Technologies 34980A - page 8

    8 Scan Feature The scan feature is a sequence of alternating swit ch closures and measurements. This feature is pro vided by bot h the 34980A and a 3499A/B/C combined wit h a DMM or ot her measurement instrument. The 34980A increases the measurement scan abilities and offers more than twice the number of scanned channels within one scan list compar ...

  • Agilent Technologies 34980A - page 9

    9 Monitor Feature The 34980A monit or feature allo ws you t o monit or readings acquired by the switch/measure system. Y ou can also monitor readings acquired wit h t he 34980A internal DMM. T o monitor a measurement from the front panel, simply select the channel and press eit her t he Measure [DMM] or [Channel] button to see a continually updated ...

  • Agilent Technologies 34980A - page 10

    10 Switch and Measurement Connections Most often, t est syst ems must be f lexible enough to be easily mov ed to a new location or modified for different devices under test. Having a remo vable wiring ter minal block or a pre-wired cable is optimal in t hese situations. The module’s terminal and/or cable can sim ply be remov ed and replaced with ...

  • Agilent Technologies 34980A - page 11

    11 Summary Although the 3499A/B/C Switch/Control system has been a great addition to many test systems, the new 34980A now offers an even better module selection plus measurement capability , standard PC connections f or communication, and is easy to connect to modules. The wide of fering of plug-in modules f or t he 34980A enables you to select a ...

  • Agilent Technologies 34980A - page 12

    12 Appendix A – Command Reference/Comparison 34980A Commands ABORt CALCulate :A VERage:AVERage? :A VERage:CLEar :A VERage:COUNt? :A VERage: MAXimum? :A VERage:MAXimum:TIME? :A VERage:MINimum? :A VERage:MINimum:TIME? :A VERage:PTPeak? :LIMit:LOW er :LIMit:LOW er? :LIMit:LOW er:ST A T e :LIMit:LOW er:ST A T e? :LIMit:UPPer :LIMit:UPPer? :LIMit:UPPe ...

  • Agilent Technologies 34980A - page 13

    13 :CURRent:AC :CURRent[:DC] :DIGital:ST A T e :DIGital:WIDTh :FREQuency :FRESistance :PERiod :RESistance :TEMPerature :TOT alize [:VOL T age]:AC [:VOL T age][:DC] CONFigure? DA T A :LAST? :POINts:EVENt:THReshold :POINts:EVENt:THReshold? :POINts? :REMove? DIAGnostic :DMM:CYCLes:CLEar :DMM:CYCles? :RELay CYCles:CLEar :RELay:CYCLes? DISPlay [:ST A T ...

  • Agilent Technologies 34980A - page 14

    14 :CURRent:AC? :CURRent[:DC]? :DIGital[:<width>]? :DIGital[:BYTE]:BIT? :FREQuency? FRESistance? :PERiod? :RESistance? :TEMPerature? :TOT alize? [:VOL T age]:AC? [:VOL T age][:DC]? MEMory :ST A T e:CA T alog? :ST A T e:DELete :ST A T e:NAME :ST A T e:NAME? :ST A T e:RECall:AUTO :ST A T e:RECall:AUTO? :ST A T e:RECall:SELect :ST A T e:RECall:S ...

  • Agilent Technologies 34980A - page 15

    15 :SCAN :SCAN:ADD :SCAN:REMove :SCAN:SIZE? SAMPle :COUNt :COUNt? SENSe :CURRent:AC :BANDwidth :BANDwidth? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :CURRent[:DC] :APERture:ENABled? :APERture :NPLC :NPLC? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :DIGital:DA T A[:<width>]? :DIGital:DA T A[BYTE]:BIT? :FREQuency ...

  • Agilent Technologies 34980A - page 16

    16 :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :FUNCtion :FUNCtion? :PERiod:APERture :PERiod:VOL T age:RANGe :VOL T age:RANGe? :VOL T age:RANGe:AUTO :VOL T age:RANGe:AUTO? :PERiod:ZERO:AUTO :RESistance:APERture :APERture? :ALPERture:ENABled? :NPLC :NPLC? :OCOMpensated :OCOMpensated? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESoluti ...

  • Agilent Technologies 34980A - page 17

    17 [:DC]:NPLC? [:DC]:RANGe [:DC]:RANGe? [:DC]:RANGe:AUTO [:DC]:RANGe:AUTO? [:DC]:RESolution [:DC]RESolution [:DC]:ZERO:AUTO [:DC]:ZERO:AUTO? SOURce :CURRent[:LEV el] :CURRent[:LEV el]? :DIGital:DA T A[:<width>] :DIGital:DA T A[BYTE]:BIT :DIGital:ST A T e? :FUNCtion:CLOCk:EXT ernal:DIVisor :CLOCk[INT ernal]:PERiod :CLOCk:SOURce :CURRent:GAIN : ...

  • Agilent Technologies 34980A - page 18

    18 :ALARm:ENABle? :ALARm[:EVENt]? :MODule:ENABle :MODule:EVENt? :MODule:SLOT[n]:CONDition? :MODule:SLOT[n]:ENABle :MODule:SLOT[n][:EVENt]? :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :OPERation[:EVENt]? :PRESet :QUEStionable:CONDition? :QUEStionable:ENABle :QUEStionable:ENABle? :QUEStionable[:EVENt]? SYST em :ABUS:INT erlock:SIMulate ...

  • Agilent Technologies 34980A - page 19

    19 :TIME? :TIME:SCAN? :VERSion? TRACe:CA T alog? [:DA T A] [:DA T A]:DAC [:DA T A]:FUNCtion :DELete:ALL :DELete[:NAME] :FREE? :POINts? TRIGger :COUnt :COUNt? :DELay :DELay? :DELay:AUTO :DELay:AUTO? :SOURce :SOURce? :TIMer :TIMer? UNIT :TEMPerature :TEMPerature? IEEE-488.2 Common Commands *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *PSC *PSC? *RCL *RST * ...

  • Agilent Technologies 34980A - page 20

    Agilent T echnologies ’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can ...

Manufacturer Agilent Technologies Category Switch

Documents that we receive from a manufacturer of a Agilent Technologies 34980A can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 34980A manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 34980A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 34980A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 34980A, service manual, brief instructions and user manuals Agilent Technologies 34980A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 34980A.

A complete manual for the device Agilent Technologies 34980A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 34980A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 34980A.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 34980A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 34980A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 34980A, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 34980A - which should help us in our first steps of using Agilent Technologies 34980A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 34980A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 34980A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 34980A?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 34980A, ask a question using the form below. If a user had a similar problem with Agilent Technologies 34980A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)