    Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide A Guide f or System Administrato rs of Inte l® Server Product s Intel Order Nu mber D67145-00 2 ...

  • Intel SBCEGBESW10 CLI - page 2

    ii Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Disclaimer Inf orm ation in this document is provided in connection with Intel® prod ucts. No license, e xpress or implied, by estoppel or otherwise, to any intellectual proper ty rights is granted by this document. Except as p rovided in Intel's T erm s and ...

  • Intel SBCEGBESW10 CLI - page 3

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide iii Safety Inf ormation Impor tant Safety Instructions Read all caution and safety statements in th is docu ment before performing any of the instructions. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche W arnund Sicherheitshinweise in diesem Dokument, be ...

  • Intel SBCEGBESW10 CLI - page 4

    iv Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Wa r n i n g s Heed safety instructions: Before working with your server product, wheth e r you are using this guide or any oth er resource as a reference, pay close attention to the safety instructions. Y ou must adhere to the assembly instructions in this guide ...

  • Intel SBCEGBESW10 CLI - page 5

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide v Preface About this Manu al Thank you for purchasing and using an Inte l® Blade Server Ethernet Switch Module SBCEGBESW1 or SBCEGBESW10. This manual is written for System Administrators who have knowledge of device management through Command Line Interface (CLI) co ...

  • Intel SBCEGBESW10 CLI - page 6

    vi Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Chapter 15 Port Channel Commands Chapter 16 Port Monitor Commands Chapter 17 QoS Commands Chapter 18 RMON Commands Chapter 19 RADIUS Commands Chapter 20 W eb Server Commands Chapter 21 SNMP Commands Chapter 22 Spanni ng-T ree Commands Chapter 23 SSH Commands Chapt ...

  • Intel SBCEGBESW10 CLI - page 7

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide vii Contents Important Safety Instructions ..................................................... ........................................... i ii Wichtige Sicherheitshinweise .................................................... ....................................... ...

  • Intel SBCEGBESW10 CLI - page 8

    viii Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide show ports security ............................................................ ............................................... ... 37 show ports security addr esses .......................................... .................................................. 3 ...

  • Intel SBCEGBESW10 CLI - page 9

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide ix shutdown ................................................... ................................................................... ....... 80 description ................................................. .............................................................. ...

  • Intel SBCEGBESW10 CLI - page 10

    x Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Chapter 10: IP Address Commands .. ........................................................ ............ 121 ip address ................................................................................................ .................... ...... 121 ip address dhcp ...

  • Intel SBCEGBESW10 CLI - page 11

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide xi show ports monitor ............... ..................................................................................... ........ 163 Chapter 17: QoS Commands .. ................................ ................. ................ .............. 165 qos ........... ...

  • Intel SBCEGBESW10 CLI - page 12

    xii Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide show rmon log ................................................................... .............................................. .. 212 rmon table-size ................................... ........................................................................... ...

  • Intel SBCEGBESW10 CLI - page 13

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide xiii show snmp filters ....................................................................... ...................................... .. 256 show snmp users ....................................... ...................................................................... ...

  • Intel SBCEGBESW10 CLI - page 14

    xiv Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide logging on ................................................................................................ .................... ...... 307 logging ..................................... ............................................................................. ...

  • Intel SBCEGBESW10 CLI - page 15

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide xv end .................................................. ......................................................................... ......... 349 help .................................................. ................................................................. ...

  • Intel SBCEGBESW10 CLI - page 16

    xvi Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide dot1x timeout tx-period ................................. ..................................................................... 3 89 dot1x max-req .............................................................................. ................................... . ...

  • Intel SBCEGBESW10 CLI - page 17

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 1 1 Using CLI Overview This document describes the Comm and Line In ter face (CLI) used to manage the Intel® Blade Server Ethernet Switch Modules SBCEGBESW 1 and SBCEGBESW10. The switches can operate as standalone systems, or can be sta cked together in the same sys ...

  • Intel SBCEGBESW10 CLI - page 18

    Using CLI 2 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The default host name is Conso le unless it has been changed using the hostname command in the Global Configuration mo de. Privileged EXEC Mode Privileged access is password prot ected to prev ent unauthorized use because many of the Privileged commands s ...

  • Intel SBCEGBESW10 CLI - page 19

    Using CLI Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 3 Configuration mode prompt consists of th e device host name followed by (c onfig) and #. 2. T o return from the Global Configuration mode to the Privileged EXEC mode, the user can use one of the following commands: exit end Ctrl+Z The following example il ...

  • Intel SBCEGBESW10 CLI - page 20

    Using CLI 4 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • MAC Access-List — Configure s conditions re quired to allow traffic based on MAC addresses. The mac access-list Global Config uration mode command is used to enter the MAC access-list configuration mode. Star ting the CLI The device can be managed o ...

  • Intel SBCEGBESW10 CLI - page 21

    Using CLI Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 5 There are two instances where help information can be displaye d: • Keyword lookup — The ch aracter ? is ente red in place of a command. A list of all valid commands and corresponding help messag es are is displayed. • Partial keyword lookup — If ...

  • Intel SBCEGBESW10 CLI - page 22

    Using CLI 6 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Nomenc lature When referring to an Ethernet port in a CLI command, the following format is used: For an Ethernet port o n a standalone device: Ethernet_typ e port_number For an Ethernet port on a stacked device : unit_number/Ethernet_type port number The ...

  • Intel SBCEGBESW10 CLI - page 23

    Using CLI Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 7 CLI Command Con ventions When entering commands there are certain command entry standards that apply to all commands. The fol lowing table describes the command convention s. Copying and P asting T ext Up to 1000 lines of text (or commands) ca n be copied ...

  • Intel SBCEGBESW10 CLI - page 24

    Using CLI 8 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 25

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 9 2 AAA Commands aaa authentication login The aaa authentication login Global Configu ration mode command defines login authentication. T o restore defaults, use the no form of this command. Syntax aaa authentication login { default | list-name } method1 [ method2 .. ...

  • Intel SBCEGBESW10 CLI - page 26

    AAA Commands 10 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines The default and optional list names created with the aaa authenti cation login command are used with the login authentication command. Create a list by entering the aaa authentication login list-name method command for a particular pro ...

  • Intel SBCEGBESW10 CLI - page 27

    AAA Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 11 Def ault Configuration If the default list is not set, only the enable passwor d is checked. This has the same effect as the co mmand aaa authentication enable default enable. Command Mode Global Configuration mode User Guidelines The default and opti ...

  • Intel SBCEGBESW10 CLI - page 28

    AAA Commands 12 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax login authentication { default | list-name } no login authentication Pa r a m e t e r s • default — Uses the default list created with the aaa authentication login command. • list-name — Uses the indicated list created with the aaa auth ...

  • Intel SBCEGBESW10 CLI - page 29

    AAA Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 13 Pa r a m e t e r s • default — Uses the default list created with the aaa authentication enable command. • list-name — Uses the indicated list created with the aaa authentication enable command. Def ault Configuration Uses the default set with ...

  • Intel SBCEGBESW10 CLI - page 30

    AAA Commands 14 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • method1 [ method2 ...] — Specify at least one method from the following list: Def ault Configuration The local user database is checked. This has the same effect as the command ip http authentication local . Command Mode Globa ...

  • Intel SBCEGBESW10 CLI - page 31

    AAA Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 15 Pa r a m e t e r s • method1 [ method2 ...] — Specify at least one method from the following list: Def ault Configuration The local user database is checked. This has the same effect as the command ip https authentication local . Command Mode Glob ...

  • Intel SBCEGBESW10 CLI - page 32

    AAA Commands 16 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays the authenticatio n config uration. pass wor d Th ...

  • Intel SBCEGBESW10 CLI - page 33

    AAA Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 17 Pa r a m e t e r s • passwor d — Password for this level. (Range: 1-159 characters) • encrypted — Encrypted pas sword to be entered, copied from another device configuration. Def ault Configuration No password is defined. Command Mode Line Con ...

  • Intel SBCEGBESW10 CLI - page 34

    AAA Commands 18 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration No enable password is defined. Command Mode Global Configuration mod e User Guidelines There are no user guidelines for this command. Example The following example sets a local level 15 pa ssword called `secret' to control ...

  • Intel SBCEGBESW10 CLI - page 35

    AAA Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 19 Command Mode Global Configuration mode User Guidelines User account can be created without a password. Example The following example configures user called bob with password `lee' and user level 15 to the system. Console(config)# username bob pas ...

  • Intel SBCEGBESW10 CLI - page 36

    AAA Commands 20 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 37

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 21 3 Address T able Commands bridge address The bridge address Interface Configuration (VLAN) mode command adds a MAC-layer station source address to the bridge table. T o delete the MAC address, use the no form of this command. Syntax bridge address mac-address {eth ...

  • Intel SBCEGBESW10 CLI - page 38

    Address T able Commands 22 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example adds a permanent static MAC-layer station s ource address 3aa2.64b3.a245 on port 1 to the bridge table. bridge multicast filtering The bridge multicast filtering Gl obal Config uration mode comman d enables fil ...

  • Intel SBCEGBESW10 CLI - page 39

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 23 bridge m ulticast address The bridge multicast address Int erface Configuration (VLAN) mode comman d registers a MAC-layer multicast address in the bridge table and statically adds po rts to the group. T o unregister the MAC addre ss, use ...

  • Intel SBCEGBESW10 CLI - page 40

    Address T able Commands 24 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example registers the MAC address: The following example registers the MA C address and ad ds ports statically . bridge multicast f orbidden ad dress The bridge multicast forbidden address Interface Configur ation (VLA ...

  • Intel SBCEGBESW10 CLI - page 41

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 25 Command Modes Interface Configuration (VLAN) mode User Guidelines Before defining forbid den ports, the multi cast group should be registered. Example In this example, MAC address 0100.5e02.0 203 is forbidden on po rt 2 within VLAN 8. brid ...

  • Intel SBCEGBESW10 CLI - page 42

    Address T able Commands 26 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Interface Configuration (VLAN) mode User Guidelines There are no user guidelines for this command. Example In this example, all multicast packets on port 1 are forwarded. bridge multicast f orbidden f orwar d-all The bridge multicast forbid ...

  • Intel SBCEGBESW10 CLI - page 43

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 27 User Guidelines IGMP snooping dynamically discovers multicast device ports. When a multicast device port is discovered, all th e multicast packets are forw arded to it unconditionally . This command prevents a p ort from becoming a multica ...

  • Intel SBCEGBESW10 CLI - page 44

    Address T able Commands 28 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example In the following example, the bridge aging time is se t to 250 seconds. c lear bridg e The clear bridge Privileged EXE C mode co mmand removes any learned entries from the forwarding database. Syntax clear bridge Def ault Configurat ...

  • Intel SBCEGBESW10 CLI - page 45

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 29 no port security Pa r a m e t e r s • forward — Forwards packets w ith unlearned source addresses, but does not learn the address. • discard — Discards packets with unlearned source addres ses. This is the default if no option is i ...

  • Intel SBCEGBESW10 CLI - page 46

    Address T able Commands 30 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • lock — Saves the current dynamic MAC addresses associated with the port and disables learning, relearning and aging. • mac-addresses — Deletes the current dynam ic MAC addresses a ssociated with the port and lea ...

  • Intel SBCEGBESW10 CLI - page 47

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 31 Def ault Configuration No addresses are defined. Command Mode Interface Configuration (Ethernet, port-channel ) mode. Cann ot be configured for a range of interfaces (range context). User Guidelines The command enable s adding secure MAC a ...

  • Intel SBCEGBESW10 CLI - page 48

    Address T able Commands 32 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines Internal usage VLANs (VLANs that are auto matically allocated on ports with a defined Layer 3 interface) are presented in the VLAN column by a port numbe r and not by a VLAN ID. "Specia ...

  • Intel SBCEGBESW10 CLI - page 49

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 33 • port-channel-num ber — A valid port-channel number . Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example In this e ...

  • Intel SBCEGBESW10 CLI - page 50

    Address T able Commands 34 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • interface — A valid Ethernet port. • port-channel-number — A valid p ort-channel number . Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidel ...

  • Intel SBCEGBESW10 CLI - page 51

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 35 Pa r a m e t e r s • vlan-id — Indicates the VLAN ID. This has to be a valid VLAN ID value. • mac-multicast-address — A va lid MAC multicast address. • ip-multicast-address — A valid IP multicast address. • format ip / mac ? ...

  • Intel SBCEGBESW10 CLI - page 52

    Address T able Commands 36 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide A multicast MAC address maps to multip le IP addresses as shown above. sho w bridg e m ulticast filtering The show bridge multicast filtering Priv ileged EXEC mode co mmand displays the multicast filtering configuration. Syntax show bridge ...

  • Intel SBCEGBESW10 CLI - page 53

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 37 Example In this example, the multicast co nfiguration for VLAN 1 is displayed. sho w por ts security The show ports security Privileged EXEC mode command displays th e port-lock status. Syntax show ports security [ethernet interf ace | por ...

  • Intel SBCEGBESW10 CLI - page 54

    Address T able Commands 38 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example In this example, all classes of entrie s in the port-lock status are displayed: The following table describes the fields shown above. sho w por ts security ad dresses The show ports security addresses Privileged EXEC mode command di ...

  • Intel SBCEGBESW10 CLI - page 55

    Address T able Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 39 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example This example displays dy namic addres ses in all curren tly locked ports. Console# show ports security addresses Port Status Learning ...

  • Intel SBCEGBESW10 CLI - page 56

    Address T able Commands 40 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 57

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 41 4 A CL Commands ip access-list The ip access-list Global Configuration mode co mmand enables the IP-Access Configuration mode an d creates Layer 3 ACLs. T o delete an ACL, use the no form of this command. Syntax ip access-list name no ip access-list name Pa r a m ...

  • Intel SBCEGBESW10 CLI - page 58

    A CL Commands 42 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide permit (ip) The permit IP-Access List Configuration mode co mmand permits traffic if the conditions defined in the permit statement match. Syntax permit { any | pr oto col } { any | { source sour ce -wildcar d }} { any | { destin ation destination-wi ...

  • Intel SBCEGBESW10 CLI - page 59

    A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 43 • dscp — Indicates matching the dscp num ber with the pack et dscp val ue. • ip-pr ecedence — Indicates matching ip-preceden ce with the pack et ip-precedence value. • icmp-type — Specifies an ICMP message type for filtering ICMP packets. ...

  • Intel SBCEGBESW10 CLI - page 60

    A CL Commands 44 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • list-of-flags — Specifies a list of TCP flags that can be triggered. If a flag is set, it is prefixed by “+”. If a flag is not set, it is prefixed by “-”. The possible values are: +urg, +ack, +psh, +rst, +syn, +fin, -urg, -ack, -psh, -r ...

  • Intel SBCEGBESW10 CLI - page 61

    A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 45 deny-tcp deny-udp Pa r a m e t e r s • disable-port — Specifies that the port is disabled. • sour ce — Specifies the IP address or host name from which the packet was sent. Specify any to indicate IP address 0.0.0.0 and mask 255.255.255.255. ...

  • Intel SBCEGBESW10 CLI - page 62

    A CL Commands 46 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • in-port port-num — ( Optional) Specifies the input port of the devise. In case of egress classification this port will be devise input port. • out-port port-num — (Optional) Specifies the output po rt of the devise. • dscp — Indicates m ...

  • Intel SBCEGBESW10 CLI - page 63

    A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 47 Syntax mac access-list name no mac access-list name Pa r a m e t e r s • name — Specifies the name of the ACL. (Range: 0-32 characters) Def ault Configuration The default for all ACLs is deny all. Command Mode Global Configuration mode User Guide ...

  • Intel SBCEGBESW10 CLI - page 64

    A CL Commands 48 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • destination — Specifies the MAC address of the host to which the packet is being sent. • destination-wildcar d — Specifies wildcard bits to be applied to the destination MAC address. Use 1s in bit positi ons to be ignored. • vlan-id — S ...

  • Intel SBCEGBESW10 CLI - page 65

    A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 49 Pa r a m e t e r s • disable-port — Indicates that the port is di sabled if the stat ement is deny . • sour ce — Specifies the MAC address of the host from which the pac ket was sent. • sour ce-wildcar d — (Optional for the first type) Sp ...

  • Intel SBCEGBESW10 CLI - page 66

    A CL Commands 50 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide service-acl The service-acl Interface Configuration mode comm and applies an ACL to the input interface. T o detach an ACL fro m an input interface, use the no form of this command. Syntax service-acl { input acl-name } no service-acl { input } Pa r ...

  • Intel SBCEGBESW10 CLI - page 67

    A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 51 Pa r a m e t e r s • name — The name of the ACL. Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example disp ...

  • Intel SBCEGBESW10 CLI - page 68

    A CL Commands 52 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays ACLs ap plied to the interfaces of a device: Console# show interfaces access-lists Interface Input ACL --------- - ...

  • Intel SBCEGBESW10 CLI - page 69

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 53 5 Cloc k Commands c loc k set The clock set Privileged EXEC mode command ma nually sets the system clock. Syntax clock set hh:mm:ss day month year or clock set hh:mm:ss month day year Pa r a m e t e r s • hh:mm:ss — Current time in hours (military format), min ...

  • Intel SBCEGBESW10 CLI - page 70

    Clock Commands 54 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide c loc k sour ce The clock source Global Co nfiguration mode command co nfigures an external time source for the system clock. Use no form of this command to disable external time sourc e. Syntax clock source { sntp } no clock source Pa r a m e t e r ...

  • Intel SBCEGBESW10 CLI - page 71

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 55 no clock timezone Pa r a m e t e r s • hours-offset — Hours dif ference from UTC. (Range: – 12 hours to +13 ho urs) • minutes-offset — Minutes dif ference from UTC. (Range: 0-59) • acr onym — The acronym of the time zone. (Range: Up t ...

  • Intel SBCEGBESW10 CLI - page 72

    Clock Commands 56 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no clock summer-time r ecurring Pa r a m e t e r s • recurring — Indicates that summer time should start and end on the corresponding specified days every year . • date — Indicates that summer time should start on the first specific date lis ...

  • Intel SBCEGBESW10 CLI - page 73

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 57 Start: Fir st Sunday in April End: Last Sunday in October T ime: 2 am local time EU rule for daylight savings time: Start: Last Sunday in March End: Last Sunday in October T ime: 1.00 am (01:0 0) Example The following example sets summer time start ...

  • Intel SBCEGBESW10 CLI - page 74

    Clock Commands 58 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Multiple keys can be ge nerated. Example The following example defines th e authentication key for SNTP . sntp authenticate The sntp authenticate Global Configuration mode comm and grants authentication for received Simple Network T ...

  • Intel SBCEGBESW10 CLI - page 75

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 59 sntp trusted-ke y The sntp trusted-key Global Configuration mode comm and authenticates the identity of a system to which Simple Ne twork T ime Protocol (SNTP) will synchronize. T o disable authentication of the identity of the system, use the no f ...

  • Intel SBCEGBESW10 CLI - page 76

    Clock Commands 60 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax sntp client poll timer seconds no sntp client poll timer P aramethers • seconds — Polling interval in se conds. (Range: 60-86 400) Def ault Configuration Polling interval is 1024 seconds. Command Mode Global Configuration mod e User Guide ...

  • Intel SBCEGBESW10 CLI - page 77

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 61 Command Mode Global Configuration mode User Guidelines Use the sntp client enable (Interface) Interface Configuration mode command to enable the SNTP client on a specific interface. Example The following exampl e enables the SNTP broadcast clients. ...

  • Intel SBCEGBESW10 CLI - page 78

    Clock Commands 62 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example enables SNTP anycast clients. sntp c lient enable (Interface) The sntp client enable Interface Configuration (Etherne t, port-channel, VLAN) mode command enables the Simple Network T ime Prot oc ol (SNTP) client on an i ...

  • Intel SBCEGBESW10 CLI - page 79

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 63 sntp unicast c lient enable The sntp unicast client enable Global Configuration mo de command enables the device to use the Simple Network T ime Protocol (S NTP) to request and accept SNTP traffic from servers. T o disable requesting and accepting ...

  • Intel SBCEGBESW10 CLI - page 80

    Clock Commands 64 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration Polling is disabled. Command Mode Global Configuration mod e User Guidelines Polling time is determined by the sntp client poll timer Global Configuration m ode command. Example The following example enables polling fo r SNTP ...

  • Intel SBCEGBESW10 CLI - page 81

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 65 Command Mode Global Configuration mode User Guidelines Up to 8 SNTP serv ers can be defined. Use the sntp unicast client enable Global Configuration mode command to enable predefined unicast clients globally . T o enable polling you should also use ...

  • Intel SBCEGBESW10 CLI - page 82

    Clock Commands 66 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines The symbol that precedes the show cl ock display indicates the following: Example The following example displays the time and date from the system clock. sho w sntp configuration The show sntp configuration Privileged E X EC mode com ...

  • Intel SBCEGBESW10 CLI - page 83

    Cloc k Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 67 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displa ys the current SNTP configuration of the device. sho w sntp status The show sntp status Privileged EXEC mode comma ...

  • Intel SBCEGBESW10 CLI - page 84

    Clock Commands 68 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example shows the status of the SNTP . Console# show sntp status ...

  • Intel SBCEGBESW10 CLI - page 85

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 69 6 Configuration and Ima g e File Commands cop y The copy Privileged EXEC mode command copi es files from a source to a destination. Syntax copy sour ce-url destination-url Pa r a m e t e r s • sour ce-url — The source file locatio n URL or reserved keyword of ...

  • Intel SBCEGBESW10 CLI - page 86

    Configuratio n and Image File Commands 70 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines The location of a file system dictates the format of the source or destination UR L. The entire copying proce ...

  • Intel SBCEGBESW10 CLI - page 87

    Configur ation and Image File Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 71 T o load a configur ation file from a network se rver to the runni ng conf iguration file of the device, enter the copy s our ce-url running-config command. The commands in the loaded configuration file are added to those in ...

  • Intel SBCEGBESW10 CLI - page 88

    Configuratio n and Image File Commands 72 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • url — The location URL or reserved ke yword of the file to be deleted. (Range: 1-160 characters) The following table displays keywords and URL prefixes: Def ault Configuration This command has no defa ...

  • Intel SBCEGBESW10 CLI - page 89

    Configur ation and Image File Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 73 Def ault Configuration If the unit number is unspecified, the de fault setting is the master unit number . Command Mode Privileged EXEC mode User Guidelines Use the show bootvar command to find out whic h image is the active ...

  • Intel SBCEGBESW10 CLI - page 90

    Configuratio n and Image File Commands 74 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the contents of the running configuration file. sho w star tup-config The show startup-config Pri vileged EXEC mode command displays the co ntents of the startup configuration file. Synt ...

  • Intel SBCEGBESW10 CLI - page 91

    Configur ation and Image File Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 75 Example The following example displa ys the contents of the ru nning configuration file. sho w backup-config The show backup-config Privileged EXEC mode command displays the contents of the backup confi guration file. Syntax ...

  • Intel SBCEGBESW10 CLI - page 92

    Configuratio n and Image File Commands 76 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the conten ts of the backup configuration file. sho w bootv ar The show bootvar Privileged EXEC mode command displays the active system image file that is loaded by the device at st artu ...

  • Intel SBCEGBESW10 CLI - page 93

    Configur ation and Image File Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 77 Example The following example displays the active system image file th at is loaded by the device at startup. Console# show bootvar Unit Active Image Selected for next boot ---- ------------ ---------------------- 1 image-1 i ...

  • Intel SBCEGBESW10 CLI - page 94

    Configuratio n and Image File Commands 78 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 95

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 79 7 Ethernet Configuration Commands interface ethernet The interface ethernet Global Configuration mode co mmand enters the interface configuration mode to configur e an Ethernet type interface. Syntax interface ethernet interface Pa r a m e t e r s • interface ? ...

  • Intel SBCEGBESW10 CLI - page 96

    Ethernet Configuration Comma nds 80 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax interface range ethernet { port-list | all } Pa r a m e t e r s • port-list — List of v a lid ports. Where mo re than one port is listed, separate the nonconsecutive ports with a comma and no spaces, use a hyphen to desi ...

  • Intel SBCEGBESW10 CLI - page 97

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 81 Def ault Configuration The interface is enabled. Command Mode Interface Configuration (Eth ernet, port-channel ) mode User Guidelines There are no user guidelines for this command. Example The following example disables Ethernet po ...

  • Intel SBCEGBESW10 CLI - page 98

    Ethernet Configuration Comma nds 82 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines There are no user guidelines for this command. Example The following example adds a de scription to Et hernet port 5. speed The speed Interface Con ...

  • Intel SBCEGBESW10 CLI - page 99

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 83 User Guidelines The no speed command in a port-channel context retu rns each port in th e port-channel to its maximum capability . Example The following example conf igures the speed operation of Eth ernet port 5 to 100 Mbps operat ...

  • Intel SBCEGBESW10 CLI - page 100

    Ethernet Configuration Comma nds 84 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example configures the duplex op eration of Ethernet port 1 to full duplex operation. negotiation The negotiation Interface Configuration (Ethernet, port-channel) mode command enables auto-negotiation op erati ...

  • Intel SBCEGBESW10 CLI - page 101

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 85 Example The following example en ables auto-negotiation on Ethernet port 1. flo wcontr ol The flowcontrol Interface Configuration (Etherne t, port-channel) mode com m and configures flow control on a given interface. T o disable fl ...

  • Intel SBCEGBESW10 CLI - page 102

    Ethernet Configuration Comma nds 86 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide mdix The mdix Interface Configuration (Ethernet) m ode command enables cable crossover on a given interface. T o disable cable crossover , use the no form of this command. Syntax mdix {on | auto} no mdix Pa r a m e t e r s • on ? ...

  • Intel SBCEGBESW10 CLI - page 103

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 87 bac k-pressure The b ac k - p re ss u re Interface Configuration (E therne t, port-channel) mode command enables back pr essure on a g iven interface. T o disable back pressure, use the no form of this command. Syntax back-pressur ...

  • Intel SBCEGBESW10 CLI - page 104

    Ethernet Configuration Comma nds 88 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration Jumbo frames are disabled on the device. Command Mode Global Configuration User Guidelines This command is relevant to Giga d evices only . This command takes effect on ly after resetting the device. Example ...

  • Intel SBCEGBESW10 CLI - page 105

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 89 User Guidelines There are no user guidelines for this command. Example In the following example, the coun ters for interface 1 are cleared. set interface active The set interface active Privileged EXEC mode command reactiv ates an ...

  • Intel SBCEGBESW10 CLI - page 106

    Ethernet Configuration Comma nds 90 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w interfaces advertise The show interfaces advertise Privileged EXEC mode command displays auto- negotiation data. Syntax show interfaces advertise [ ethernet interface | port-channel port-channel-number ] Pa r a m e t e r s ? ...

  • Intel SBCEGBESW10 CLI - page 107

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 91 sho w interfaces configuration The show interfaces configuration Privileged EXEC mode command displays the configuration for all configured interfaces. Syntax show interfaces configuration [ ethernet interface | po rt-channel port- ...

  • Intel SBCEGBESW10 CLI - page 108

    Ethernet Configuration Comma nds 92 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w interfaces status The show interfaces status Privileged EXEC mod e command displays the status of all configured interfaces. Syntax show interfaces status [ethernet interface | port-channel port-channel-number |] Pa r a m e t ...

  • Intel SBCEGBESW10 CLI - page 109

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 93 User Guidelines There are no user guidelines for this command. Example The following example disp lays the status of a ll configured interfaces. sho w interfaces description The show interfaces desc ription Privileged EXEC mode com ...

  • Intel SBCEGBESW10 CLI - page 110

    Ethernet Configuration Comma nds 94 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Modes Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays desc riptions of configured ...

  • Intel SBCEGBESW10 CLI - page 111

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 95 • port-channel-number — A valid port-channel num ber . Def ault Configuration This command has no default configuration. Command Modes Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example ...

  • Intel SBCEGBESW10 CLI - page 112

    Ethernet Configuration Comma nds 96 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following example displays counters fo r Ethernet port 1. The following table describes the fields shown i n the display . Console# show interfaces counters ethernet e xt. 1 Port InOctets InUcastPkts InMcastPkts InBcastPkts --- ...

  • Intel SBCEGBESW10 CLI - page 113

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 97 sho w por ts jumbo-frame The show ports jumbo-frame Privileged EXEC mode command displa ys the configuration of jumbo frames. Syntax show ports jumbo-frame Def ault Configuration This command has no default configuration. Command M ...

  • Intel SBCEGBESW10 CLI - page 114

    Ethernet Configuration Comma nds 98 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide por t storm-contr ol include-m ulticast (GC) The port storm-control include-multicast Interface Configuration mode command enables counting multicast packets in the port storm-control br oadcast rate command. T o disable counting m ...

  • Intel SBCEGBESW10 CLI - page 115

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 99 Pa r a m e t e r s • unknown-unicast — Specifies also countin g unknown unicast packets. Def ault Configuration Multicast packets are not counted. Command Modes Interface Configuration (Ethernet) mode User Guidelines There are ...

  • Intel SBCEGBESW10 CLI - page 116

    Ethernet Configuration Comma nds 100 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Use the port storm-control br oadcast rate Interface Configuration (Ethernet) mode command, to set the maximum allowable broadcast rate. Use the port storm-control include-multicast Global Configur ation mode comma ...

  • Intel SBCEGBESW10 CLI - page 117

    Ethernet Configurat ion Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 101 Example The following example configures a port storm-control b roadcast rate 4000 on port 2. sho w por ts storm-contr ol The show ports storm-control Privileged EXEC mode comman d displays the storm control configuration. Syntax ...

  • Intel SBCEGBESW10 CLI - page 118

    Ethernet Configuration Comma nds 102 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide 3 Disabled 3500 Broadcast 4 Disabled 3500 Broadcast 5 Disabled 3500 Broadcast 6 Disabled 3500 Broadcast ...

  • Intel SBCEGBESW10 CLI - page 119

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 103 8 GVRP Commands gvrp enable (Global) GARP VLAN Registration Protocol (GVRP) is an industry-st a ndard protocol designed to propagate VLAN information from de vice to device. With GVRP , a single device is manually configured with all desired VLANs for the network ...

  • Intel SBCEGBESW10 CLI - page 120

    GVRP Commands 104 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax gvrp enable no gvrp enable Def ault Configuration GVRP is disabled on all int e rfaces. Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines An access port does not dynami cally join a VLAN because it is always ...

  • Intel SBCEGBESW10 CLI - page 121

    GVRP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 105 • timer_value — T imer values in milliseconds in multiples of 10. (Range: 10- 214748364 0) Def ault Configuration Following are the default timer values: • Join timer — 200 milliseco nds • Leave timer — 600 milliseconds • Leavall timer ...

  • Intel SBCEGBESW10 CLI - page 122

    GVRP Commands 106 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration Dynamic VLAN creation or modification is enabled. Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines This command forbids dy namic VLAN crea tion from the interface. The creation or modificatio ...

  • Intel SBCEGBESW10 CLI - page 123

    GVRP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 107 User Guidelines There are no user guidelines for this command. Example The following example forbid s dynamic registration of VLA Ns on Ethernet port 1. c lear gvrp statistics The clear gvrp statistics Privileged EXEC mode comma nd clears all GVRP s ...

  • Intel SBCEGBESW10 CLI - page 124

    GVRP Commands 108 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w gvrp configuration The show gvrp configuration Privieged EXEC mode command displays GV RP configuration information, in cluding timer values, whether GVRP and dynamic VLAN creation is enabled, and wh ich ports are ru nning GVRP . Syntax show g ...

  • Intel SBCEGBESW10 CLI - page 125

    GVRP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 109 sho w gvrp statistics The show gvrp statistics Privieged EXEC mode comman d displays GVRP statistics. Syntax show gvrp statistics [ ethernet interface | port-channel port-channel-number ] Pa r a m e t e r s • interface — A valid Ethernet port. ( ...

  • Intel SBCEGBESW10 CLI - page 126

    GVRP Commands 110 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w gvrp error -statistics The show gvrp error -statistics Privieged EXEC mode command displays GVRP error statistics. Syntax show gvrp error -statistics [ ethernet inte rface | port-channel port-c hannel-number ] Pa r a m e t e r s • interface ...

  • Intel SBCEGBESW10 CLI - page 127

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 111 9 IGMP Snooping Commands ip igmp snooping (Global) The ip igmp snooping Global Configuratio n mode command enables Internet Group Management Protoco l (IGMP) snooping. T o disable IGMP snooping, use the no form of this command. Syntax ip igmp snooping no ip igmp ...

  • Intel SBCEGBESW10 CLI - page 128

    IGMP Snooping Command s 112 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax ip igmp snooping no ip igmp snooping Def ault Configuration IGMP snooping is disabled . Command Mode Interface Configuration (VLAN) mode User Guidelines IGMP snooping can only be enabled o n static VLANs. It must not be enabled on P ...

  • Intel SBCEGBESW10 CLI - page 129

    IGMP Snooping Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 113 Command Mode Interface Configuration (VLAN) mode User Guidelines Multicast device ports can be co nfigured statically using the bridge multicast forward- all Interface Configuration (VLAN) mode co mmand. Example The following example enable ...

  • Intel SBCEGBESW10 CLI - page 130

    IGMP Snooping Command s 114 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines The timeout should be at least greater than 2*query_interval+max_response_tim e of the IGMP router . Example The following example configures the host timeout to 300 seconds. ip igmp snooping mr outer -time-out The ip igmp ...

  • Intel SBCEGBESW10 CLI - page 131

    IGMP Snooping Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 115 Example The following example configures the mu lticast device timeout to 200 seconds. ip igmp snooping lea ve-time-out The ip igmp snooping leave-time-out Interface Configuration (VLAN) mode command configures the leave-time-out. If an IGM ...

  • Intel SBCEGBESW10 CLI - page 132

    IGMP Snooping Command s 116 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example configures the host leave timeout to 6 0 seconds. sho w ip igmp snooping mrouter The show ip igmp snooping mrouter Privileged EXEC mo de command displays information on dynamically le arned multicast device in ...

  • Intel SBCEGBESW10 CLI - page 133

    IGMP Snooping Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 117 sho w ip igmp snooping interface The show ip igmp snooping interface Privileged EXEC mode comma nd displays IGMP snooping configuration. Syntax show ip igmp snooping interface vlan-id Pa r a m e t e r s • vlan-id — Specifies the VLAN nu ...

  • Intel SBCEGBESW10 CLI - page 134

    IGMP Snooping Command s 118 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays IGMP snooping information on VLAN 1000. sho w ip igmp snooping groups The show ip igmp snooping groups Privileged EXEC mode co mmand displays multicast groups learned b y IGMP snooping. Syntax show ip ...

  • Intel SBCEGBESW10 CLI - page 135

    IGMP Snooping Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 119 Example The following example sh ows IGMP snooping informatio n on multicast groups. Console# show ip igmp snooping groups Vlan IP Address Querier Ports ---- ----------------- ------- ---------- 1 224-239.130|2.2.3 Yes 1, 2 19 224-239.130|2 ...

  • Intel SBCEGBESW10 CLI - page 136

    IGMP Snooping Command s 120 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 137

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 121 10 IP Ad dress Commands ip address ip address ip-addr ess { mask | pr e fix-length } The ip address Interface Configuration (Eth ernet, VLAN, port-channel) mode command sets an IP address. T o remove an IP ad dress, use the no form of this command. Syntax ip addr ...

  • Intel SBCEGBESW10 CLI - page 138

    IP Address Comm ands 122 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example config ures VLAN 1 with IP add ress 131.108.1.27 and subnet mask 255.255.255 .0 ip address dhcp The ip address dhcp Interface Configuration (Ether net, VLAN, port-chann el) mode command acquires an IP address for ...

  • Intel SBCEGBESW10 CLI - page 139

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 123 If the device is configured to obtain its IP address from a DHCP server, it sends a DHCPDISCOVER message to provide information about itself to the DHCP server on the network. If the ip address dhcp command is used with or withou t the option ...

  • Intel SBCEGBESW10 CLI - page 140

    IP Address Comm ands 124 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines This command is onl y oper ational in Switch mode. Example The following example de fines default gateway 192.168.1. . sho w ip interface The show ip interface Privileged EXEC mode command displays the usability status of conf ...

  • Intel SBCEGBESW10 CLI - page 141

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 125 Example The following example the displays the configured IP interfaces and their types arp The arp Global Configuration mode command ad ds a permanent entr y in the Address Resolution Protocol (ARP) cache. T o remove an entry from the ARP ca ...

  • Intel SBCEGBESW10 CLI - page 142

    IP Address Comm ands 126 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Global Configuration mod e User Guidelines The software uses ARP cache entries to translat e 32-bit IP addresses into 48-bit hardware addresses. Because most hosts support dynami c res olution, static ARP cache entries do not gen ...

  • Intel SBCEGBESW10 CLI - page 143

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 127 User Guidelines It is recommended not to set the timeout value to less than 3600. Example The following example conf igures the ARP timeout to 12000 seconds . c lear arp-cache The clear arp-cache Privileged EXEC mode command de letes all dyna ...

  • Intel SBCEGBESW10 CLI - page 144

    IP Address Comm ands 128 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax show arp Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays entries in the ARP table ...

  • Intel SBCEGBESW10 CLI - page 145

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 129 Def ault Configuration IP Domain Naming System ( DNS)-based host name-to-address translation is enabled. Command Mode Global Configuration mode User Guidelines There are no user guidelines for this command. Example The following example enabl ...

  • Intel SBCEGBESW10 CLI - page 146

    IP Address Comm ands 130 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command. Example The following example defines defa ult domain name www .intel.com . ip name-server The ip name-server Global Configuration mod e command defines the available name servers ...

  • Intel SBCEGBESW10 CLI - page 147

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 131 ip host The ip host Global Configurat ion mode command define s static host name-to-ad dress mapping in the ho st cache. T o remove the name-to-address mapping, use the no form of this command. Syntax ip host name address no ip host name Pa r ...

  • Intel SBCEGBESW10 CLI - page 148

    IP Address Comm ands 132 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • name — Specifies the ho st entry to be removed. (Range: 1-158 characters) • * — Removes all entries. Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guideli ...

  • Intel SBCEGBESW10 CLI - page 149

    IP Address Comm ands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 133 Command Mode Privileged EXEC mode User Guidelines This command is only op erational in Switch mode. This command deletes the ho st name-to-address map ping temporarily until the ne xt renewal of the IP address. Example The following example d ...

  • Intel SBCEGBESW10 CLI - page 150

    IP Address Comm ands 134 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example disp lays host information. . Console# show hosts System name: Device Default domain is gm.com, s ales.gm.com, usa.sales.gm.com(DHCP) Name/address lookup is enab led Name servers (Preference or der): 176.16.1.18 ...

  • Intel SBCEGBESW10 CLI - page 151

    LA CP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 135 11 LA CP Commands lacp system-priority The lacp system-priority Global Co nfiguration mode command configures the system priority . T o return to the de fault configuration, use the no form of this command. Syntax lacp system-priority value no lacp ...

  • Intel SBCEGBESW10 CLI - page 152

    LACP Commands 136 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax lacp port-priority value no lacp port-priority Pa r a m e t e r s • value — Specifies port priority . (Range: 1-65535) Def ault Configuration The default port priority is 1. Command Mode Interface Configuration (Ethernet) mode User Guidel ...

  • Intel SBCEGBESW10 CLI - page 153

    LA CP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 137 • short — Specifies the short timeout value. Def ault Configuration The default port timeout value is long . Command Mode Interface Configuration (Ethernet) mode User Guidelines There are no user guidelines for this command. Example The followi ...

  • Intel SBCEGBESW10 CLI - page 154

    LACP Commands 138 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example display LACP information for Et hernet port 1. Console # show lacp ethernet ext.1 Port 1 LACP parameters: Actor system pri ...

  • Intel SBCEGBESW10 CLI - page 155

    LA CP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 139 sho w lacp por t-channel The show lacp port-channel Privileged EXEC mode command d isplays LACP information for a port-channel. port Oper timeout: LONG LACP Activity: PASSIVE Aggregation: AGGREGATABLE synchronization: FALSE collecting: FALSE distri ...

  • Intel SBCEGBESW10 CLI - page 156

    LACP Commands 140 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax show lacp port-channel [ port_chann el_number ] Pa r a m e t e r s • port_channel_nu mber — V alid port-channel nu mber . Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines ...

  • Intel SBCEGBESW10 CLI - page 157

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 141 12 Line Commands Line The Line Global Configuration mode com m and identiofies a specific line for configuration, and begin s the process. Syntax Line {telnet | ssh} Pa r a m e t e r s • telnet — V irtual terminal fo r remote console access. • ssh — V irt ...

  • Intel SBCEGBESW10 CLI - page 158

    Line Commands 142 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax show line {telnet | ssh} Pa r a m e t e r s • telnet — V irtual terminal fo r remote console access. • ssh — V irtual terminal for secured remote console access. Def ault Configuration This command has no default configuration. Comman ...

  • Intel SBCEGBESW10 CLI - page 159

    Line Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 143 ...

  • Intel SBCEGBESW10 CLI - page 160

    Line Commands 144 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 161

    Management A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 145 13 Mana g ement A CL Commands management access-list The management access-lis t Global Configuration mode comm and configures a management access list and enters the Mana gement Acc ess-list Configuration command mode. T o delete an acce ...

  • Intel SBCEGBESW10 CLI - page 162

    Management A C L Commands 146 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example creates a manageme nt access list called mlist, configures management Eth ernet interfaces 1 and 9 an d makes the new access list the active list. The following example creates a management access list calle ...

  • Intel SBCEGBESW10 CLI - page 163

    Management A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 147 permit (Management) The permit Management Access-List Configuration mode co mmand defines a permit rule. Synt ax permit [ ethernet interface-number | vlan vlan-id | port-channel port-channel-number |] [ service service ] permit ip-sour c ...

  • Intel SBCEGBESW10 CLI - page 164

    Management A C L Commands 148 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide deny (Management) The deny Management Access-List Config uration mode command de fines a deny rule. Synt ax deny [ ethernet interface-number | vlan vlan-id | port-channel port-channel-number |] [ service service ] deny ip-source ip-addre ...

  • Intel SBCEGBESW10 CLI - page 165

    Management A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 149 management access-class The management access-clas s Global Configuration mo de command restricts management connections by de fining the active management access list. T o disable this restriction, use the no form of this command. Synt a ...

  • Intel SBCEGBESW10 CLI - page 166

    Management A C L Commands 150 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide show management access-list The show management acces s-list Privileged EXEC mode command displays management access-lists. Synt ax show management access-list [ name ] Parameters • name — S pecifies the name of a management acce ss ...

  • Intel SBCEGBESW10 CLI - page 167

    Management A CL Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 151 show management access-class The show management access-class Privileged EXEC mode command displays the active management access list. Synt ax show management access-class Default Configur ation This command has no default configuration. ...

  • Intel SBCEGBESW10 CLI - page 168

    Management A C L Commands 152 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 169

    PHY Diagnostics Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 153 14 PHY Diagnostics Commands test copper -por t tdr The test copper - port tdr Privileged EXEC mode command uses T ime Domain Reflectometry (TDR) technology to diagnose th e quality and character istics of a copper cable attached to a port ...

  • Intel SBCEGBESW10 CLI - page 170

    PHY Diagnostics Commands 154 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w copper-ports tdr The show copper -ports tdr User EXEC mode command disp la ys information on the last T ime Domain Reflectometry (TDR) test performed on copper ports. Syntax show copper -ports tdr [ interface ] Pa r a m e t e r s ? ...

  • Intel SBCEGBESW10 CLI - page 171

    PHY Diagnostics Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 155 sho w copper-ports cable-length The show copper -ports cable-length User EXEC mode command displays the estimated copper cable length attached to a port. Syntax show copper -ports cable-length [ interface ] Pa r a m e t e r s • interfac ...

  • Intel SBCEGBESW10 CLI - page 172

    PHY Diagnostics Commands 156 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 173

    P or t Channel Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 157 15 P or t Channel Commands interface por t-channel The interface port-channel Global Configuration mode command enters the interface configuration mode to configure a specific port-cha nnel. Syntax interface port-channel port-channel-numbe ...

  • Intel SBCEGBESW10 CLI - page 174

    P or t Channel Commands 158 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide interface range por t-channel The interface range port-channel Global Configuration mode co mmand enters the interface configuration mode to configure multiple port-channels. Syntax interface range port-channel { port-channel-range | all } ...

  • Intel SBCEGBESW10 CLI - page 175

    P or t Channel Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 159 Syntax channel-group p o rt-channel-number mode { on | auto } no channel-group Pa r a m e t e r s • port-channel_number — Specifies the number of th e valid port-channel for the current port to join. • on — Forces the port to join ...

  • Intel SBCEGBESW10 CLI - page 176

    P or t Channel Commands 160 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • port-channel-numb er — V alid port-cha nnel number . Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command ...

  • Intel SBCEGBESW10 CLI - page 177

    P or t Monitor Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 161 16 P or t Monitor Commands por t monitor The port monitor Interface Configuration mode comm and starts a port monitoring session. T o stop a port monitoring session, use the no form of this command. Syntax port monitor sr c-interface [rx | ...

  • Intel SBCEGBESW10 CLI - page 178

    P or t Monitor Commands 162 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following restrictions apply to po rts configured to be source ports: The port cannot be already con f igured as a destination port. Example The following example copies traffic on port 8 (source port) to port 1 (destination port). por ...

  • Intel SBCEGBESW10 CLI - page 179

    P or t Monitor Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 163 sho w por ts monitor The show ports monitor User EXEC mode command displays the port monitoring status. Syntax show ports monitor Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines ...

  • Intel SBCEGBESW10 CLI - page 180

    P or t Monitor Commands 164 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 181

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 165 17 QoS Commands qos The qos Global Configuration mode command en ables quality of serv ice (QoS) on the device. T o disable QoS on the device, use the no form of this command. Syntax qos [basic | advanced | service] no qos Pa r a m e t e r s • basi ...

  • Intel SBCEGBESW10 CLI - page 182

    QoS Commands 166 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w qos The show qos User EXEC mode command displays the quality of service (QoS) mode for the device. Syntax show qos Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines T rust mode is disp ...

  • Intel SBCEGBESW10 CLI - page 183

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 167 Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are n o user guidelines. Example The following example displays the parameters of the aggregate policer called ‘policer1’. s ...

  • Intel SBCEGBESW10 CLI - page 184

    QoS Commands 168 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration There is no default config uration for this command. Command Mode Privileged EXEC mode User Guidelines If no keyword is specified , port QoS mode (for example., DSCP trusted, CoS trusted, untrusted), default CoS value, DSCP-to- ...

  • Intel SBCEGBESW10 CLI - page 185

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 169 sho w qos map The show qos map User EXEC m ode command displays all QoS maps. Syntax show qos map [ dscp-queue ] Pa r a m e t e r s • dscp-queue — Indicates the DSCP to queue map. Def ault Configuration This command has no default configuration. ...

  • Intel SBCEGBESW10 CLI - page 186

    QoS Commands 170 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays th e DSCP port-queue map . The following table describes the sign ificant fields shown abov e. c lass-map The create-map Global Configuration mode comman d creates or modifies a class ma p and enters the Class-m ...

  • Intel SBCEGBESW10 CLI - page 187

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 171 • match-any — Checks that the packet matches on e or more classification criteria in the class map match stat ement. Def ault Configuration By default, the match-all parameter is selected. Command Mode Global Configuration mode User Guidelines Th ...

  • Intel SBCEGBESW10 CLI - page 188

    QoS Commands 172 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • class-map-name — Specifies the name of the class map to be displayed. Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines There are no user guidelines for this command ...

  • Intel SBCEGBESW10 CLI - page 189

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 173 Command Mode Class-map Configuration mode. User Guidelines There are no user guidelines for this command. Example The following example defines the match crite rion for classifying traffic as an access group called enterprise in a class map called cl ...

  • Intel SBCEGBESW10 CLI - page 190

    QoS Commands 174 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Before configuring policies for classes whose match criteria are defined in a class map, use the policy-map Global Configuration m ode comma nd to specify the name of the policy map to be created or modified. Class policies in a polic ...

  • Intel SBCEGBESW10 CLI - page 191

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 175 Command Mode Policy-map Configuration mode User Guidelines Before modifying a policy for an existing class or creating a policy for a new class, use the policy-map Global Co nfiguration mode command to specify the name of the policy map to which the ...

  • Intel SBCEGBESW10 CLI - page 192

    QoS Commands 176 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode User EXEC mode User Guidelines There are no user guidel ines f or this command. Example The following example displays all policy maps. trust cos-dscp The trust cos-dscp Policy-map Class Configuration mode command configures the trust st ...

  • Intel SBCEGBESW10 CLI - page 193

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 177 User Guidelines Action serviced to a class, so that if an IP packet arrives, the qu eue is assigned per DSCP . If a non-IP p acket arrives, the queue is assigned per CoS (VP T). Example The following example configur es the trust state for a class ca ...

  • Intel SBCEGBESW10 CLI - page 194

    QoS Commands 178 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Policy maps that contain set or trust Policy-map Cla ss Configuration commands or that have ACL classifications cannot be attach ed to an egress interface by using the se rvice- policy (Ethernet, Port-channel) Interfa ce Configuration mode command. T ...

  • Intel SBCEGBESW10 CLI - page 195

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 179 Command Mode Policy-map Class Configuration mode User Guidelines Policing uses a token bucket algorithm. CIR re presents the speed with which the token is removed from th e bucket. CBS represents the depth of t he bucket. Example The following exampl ...

  • Intel SBCEGBESW10 CLI - page 196

    QoS Commands 180 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Only one policy m ap per interface per direction is supported. Example The following example attaches a policy ma p called policy1 to the input interface. qos ag gregate-policer The qos aggregate-policer Global Configuratio n mode com ...

  • Intel SBCEGBESW10 CLI - page 197

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 181 User Guidelines Policers that contain set or trust Policy-map Class Configura tion commands or that have ACL classifications cannot be att ached to an output interface. Define an aggregate policer if the po licer is shared with multiple classes. Poli ...

  • Intel SBCEGBESW10 CLI - page 198

    QoS Commands 182 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines There are no user guidelines. Example The following example displays the parameters of the aggr egate policer called policer1. police ag gre ...

  • Intel SBCEGBESW10 CLI - page 199

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 183 User Guidelines An aggregate policer can be applied to mul tiple classes in the same policy map; An aggregate policer cannot be applied across multiple policy ma ps or interfaces. T o return to the Policy-map Configuration mode, use the exit command. ...

  • Intel SBCEGBESW10 CLI - page 200

    QoS Commands 184 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Cos4 is mapped to queue 5. Cos5 is mapped to queue 6. Cos6 is mapped to queue 7. Cos7 is mapped to queue 8. Command Mode Global Configuration mod e User Guidelines This command can be used to distribute traf fic into dif ferent queues, whe re each qu ...

  • Intel SBCEGBESW10 CLI - page 201

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 185 Def ault Configuration The default WRR weight ratio is one-eighth of the sum of all queue weights (each weight is set to 6). Command Mode Interface Configuration (Eth ernet, port-channel ) mode User Guidelines Use the priority-queue out num-of-queues ...

  • Intel SBCEGBESW10 CLI - page 202

    QoS Commands 186 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no priority-queue out num-of-queues Pa r a m e t e r s • number -of-queues — Specifies the number of expedite queues. Exped ite queues have higher indexes. (Range: 0-8) Def ault Configuration All queues are expedite queues. Command Mode Global Co ...

  • Intel SBCEGBESW10 CLI - page 203

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 187 • excess-burst — Specifies the exces s burst si ze (CBS) in bytes.(Range: 4096- 16769020) • queue-id — Specifies the queue number to whic h the shaper is assigned. (Range: 0-8) Def ault Configuration No shape is defined. Command Mode Interfac ...

  • Intel SBCEGBESW10 CLI - page 204

    QoS Commands 188 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • buffers – Displays the buffer setting for the interface’ s queues. Di splays the queue depth for each queu e and the thresholds for the WRED. • queuing — Displays the queue strategy (WRR or EF), the weight for WRR queues, the CoS to queue ...

  • Intel SBCEGBESW10 CLI - page 205

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 189 qos wrr -queue threshold The wrr -queue threshold Global Conf iguration mode command assigns queue thresholds globally . T o return to the default configuration, use the no form of this command. Syntax qos wrr -queue threshold queue-id thr eshold-per ...

  • Intel SBCEGBESW10 CLI - page 206

    QoS Commands 190 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide qos wrr -queue threshold tengigabitethernet queue-id thr eshold-per centage0 thr eshold- per centage1, thr eshold-per c entage2 no qos wrr -queue thr eshold tengigabitethernet queue-id Pa r a m e t e r s • gigabitethernet — Indicates that the thr ...

  • Intel SBCEGBESW10 CLI - page 207

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 191 Syntax qos map policed-dscp dscp-list to dscp-mark -down no qos map policed-dscp Pa r a m e t e r s • dscp- list — Specifies up to 8 DSCP va lues separated by a spa ce. (Range: 0-63) • dscp-mark-down — Specifies the DSCP value to mark down. ( ...

  • Intel SBCEGBESW10 CLI - page 208

    QoS Commands 192 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • dscp-list — S peci fies up to 8 DSCP values separated by a space. (Range: 0 - 63) • queue-id — S pecifies the queue numbe r to which the DSCP values are mapped. Default Configuration The following table describes the defa ...

  • Intel SBCEGBESW10 CLI - page 209

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 193 Def ault Configuration CoS is the default trust mode. Command Mode Global Configuration mode User Guidelines Packets entering a quality of service (QoS) do main are classified at the edge of the QoS domain. When packets are classified at the edge, th ...

  • Intel SBCEGBESW10 CLI - page 210

    QoS Commands 194 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines There are no user guidelines for this command. Example The following example configures Ethern et port 15 to the default trust state. qos cos The qos cos Interface Co ...

  • Intel SBCEGBESW10 CLI - page 211

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 195 Example The following example conf igures port 15 default CoS value to 3. qos dscp-m utation The qos dscp-mutation Global Configu ration mode command applies the DSCP Mutation map to a system DSCP trusted port. T o return to the trust state with no D ...

  • Intel SBCEGBESW10 CLI - page 212

    QoS Commands 196 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example applies the DSCP Mu tation map to system DSCP trusted ports. qos map dscp-m utation The qos map dscp-mutation Global Configuration m ode command modifies the DSCP to DSCP mutation map. T o return to the de fault DSCP to ...

  • Intel SBCEGBESW10 CLI - page 213

    QoS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 197 ...

  • Intel SBCEGBESW10 CLI - page 214

    QoS Commands 198 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 215

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 199 18 RMON Commands sho w rmon statistics The show rmon statistics Privileged EXEC mode command displays RMON Ethernet statistics. Syntax show rmon statistics { ethernet interface number | port-channel port-channel-number } Pa r a m e t e r s • interface number ? ...

  • Intel SBCEGBESW10 CLI - page 216

    RMON Commands 200 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following table describes the sign ificant fields show n in the display . Fragments: 0 Jabbers: 0 64 Octets: 98 65 to 127 Octets: 0 128 to 255 Octets: 0 256 to 511 Octets: 0 512 to 1023 Octets: 491 1024 to 1518 Octets: 389 Field Description Octe ...

  • Intel SBCEGBESW10 CLI - page 217

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 201 rmon collection history The rmon collection history Interface Configuration (Eth ernet, port-channel ) mode command en ables a Remote Monitoring (RMON) MIB history statistics group on an interface. T o remove a specified RMON history statistics grou ...

  • Intel SBCEGBESW10 CLI - page 218

    RMON Commands 202 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Cannot be configured for a rang e of interfaces (Range context). Example The following example enables a Remote Mo nitoring (RMON) MIB history statistics group on Ethernet port 1 wi th index number 1 and a pollin g interval period of ...

  • Intel SBCEGBESW10 CLI - page 219

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 203 The following example displays all RMON history group statistics. The following table describes the sig n ificant fields shown in the display . sho w rmon histor y The show rmon history Privileged EXEC mode command d isplays RMON Ethernet history st ...

  • Intel SBCEGBESW10 CLI - page 220

    RMON Commands 204 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays RMON Et hernet history statistics for index 1. Console# show rmon history 1 throughput Sample Set: 1 Owner: CLI I ...

  • Intel SBCEGBESW10 CLI - page 221

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 205 The following table describes signif icant fields show n in the example: Console# show rmon history 1 other Sample Set: 1 Owner: Me Interface:1 Interval: 1800 Requested samples: 50 Granted samples: 50 Maximum table size: 500 Time Dropped Collisions ...

  • Intel SBCEGBESW10 CLI - page 222

    RMON Commands 206 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide rmon alarm The rmon alarm Global Configuration mode command configures alarm conditions. T o remove an alarm, use the no form of this command. Syntax rmon alarm index variable interval rthr eshold fthreshold r event fev ent [ type type ] [ startup d ...

  • Intel SBCEGBESW10 CLI - page 223

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 207 • type — Specifies the method used for samplin g the selected variable and calculating the value to be compared against the thresholds. Possible values are absolute and delta . • If the method is absolute , the value of the selected variable i ...

  • Intel SBCEGBESW10 CLI - page 224

    RMON Commands 208 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w rmon alarm-table The show rmon alarm-table Privileged EXEC mode command displays the alarms table. Syntax show rmon alarm-table Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines ...

  • Intel SBCEGBESW10 CLI - page 225

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 209 sho w rmon alarm The show rmon alarm Privileged EXEC mo de command d isplays a larm configuration . Syntax show rmon alarm number Pa r a m e t e r s • number — Specifies the alarm index. (Ran ge: 1-65535) Def ault Configuration This command has ...

  • Intel SBCEGBESW10 CLI - page 226

    RMON Commands 210 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following table describes the sign ificant fields shown in the display: rmon e vent The rmon event Global Configuratio n mode comman d configures an event. T o remove an event, use the no form of this command. Syntax rmon event index type [ comm ...

  • Intel SBCEGBESW10 CLI - page 227

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 211 • community text — If the specified notification t ype is trap , an SNMP trap is sent to the SNMP community specif ied by this oc tet string. (Range: 0-127 characters) • description text — Specifies a comment describing this event. (Range: 0 ...

  • Intel SBCEGBESW10 CLI - page 228

    RMON Commands 212 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command. Example The following example displa ys the RMON event table. The following table describes sign if icant fields shown in the example: sho w rmon log The show rmon lo g Privileged EXEC m ...

  • Intel SBCEGBESW10 CLI - page 229

    RMON Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 213 Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example disp lays the RMON log table. The following table descri ...

  • Intel SBCEGBESW10 CLI - page 230

    RMON Commands 214 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide rmon tabl e-size The rmon table-size Global Con figuration mode command co nfigures the maximum size of RMON tables. T o return to the default configuration, use the no form of this command. Syntax rmon table-size { history entries | log entries } n ...

  • Intel SBCEGBESW10 CLI - page 231

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 215 19 RADIUS Commands radius-server host The radius-server host Global Configuration mode command specifies a RADIUS server host. T o delete the specified RADIUS host, use the no form of this command. Syntax radius-server host { ip-addr ess | hostname } [ auth-port ...

  • Intel SBCEGBESW10 CLI - page 232

    RADIUS Commands 216 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The port number for authentic ation requests is 1812. The usage type is all . Command Mode Global Configuration mod e User Guidelines T o specify multiple hosts, multiple radius-server host commands can be used. If no host-specific timeout, retr i ...

  • Intel SBCEGBESW10 CLI - page 233

    RADIUS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 217 Def ault Configuration The key-string is an empty string. Command Mode Global Configuration mode User Guidelines There are no user guidelines for this command. Example The following example define s the authentication and encr yption key for all R ...

  • Intel SBCEGBESW10 CLI - page 234

    RADIUS Commands 218 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command. Example The following example configures the numb er of times the software searches all RADIUS server hosts to 5 times. radius-server source-ip The radius-server source-ip Global Confi ...

  • Intel SBCEGBESW10 CLI - page 235

    RADIUS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 219 Example The following example configures the source IP address used for communication with all RADIUS servers to 10.1.1.1. radius-server timeout The radius-server timeout Global Configuration mode comm and sets the interval during which the device ...

  • Intel SBCEGBESW10 CLI - page 236

    RADIUS Commands 220 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide radius-server deadtime The radius-server deadtime Global Configuration mode command improves RADIUS response time when servers are unavaila ble. The command is used to cause the unavailable servers to be skip ped. T o restore the default configura ...

  • Intel SBCEGBESW10 CLI - page 237

    RADIUS Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 221 Syntax show radius-servers Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays RADIUS server sett ...

  • Intel SBCEGBESW10 CLI - page 238

    RADIUS Commands 222 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 239

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 223 20 W eb Ser ver Commands ip http server The ip http server Global Configuration mode co mm and enables configuring the device from a browser . T o disable this function, use the no form of this command. Syntax ip http server no ip http serve ...

  • Intel SBCEGBESW10 CLI - page 240

    W eb Ser ver Commands 224 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no ip http port Pa r a m e t e r s • port-number — Port number for use by the HTTP server . (Range: 0-65535) Def ault Configuration The default port number is 80. Command Mode Global Configuration mod e User Guidelines Use the crypto cer ...

  • Intel SBCEGBESW10 CLI - page 241

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 225 Def ault Configuration The default timout is 10 minutes. Command Mode Global Configuration mode User Guidelines This command also configures the exec-timeout for HTTPS in case the the HTTPS timeout was not set. T o specif y no timeout, enter ...

  • Intel SBCEGBESW10 CLI - page 242

    W eb Ser ver Commands 226 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ip https por t The ip https port Global Configuration m ode command specifies the TCP port u sed by the server to configure the device through the W eb browser . T o return to the default configuration, use the no form of this command. Synta ...

  • Intel SBCEGBESW10 CLI - page 243

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 227 no ip https exec-timout Pa r a m e t e r s • minutes — Specifies the numbe r of minutes to wait. • seconds — Specifies the number of seconds to wait. Def ault Configuration The default timout is 10 minutes. Command Mode Global Config ...

  • Intel SBCEGBESW10 CLI - page 244

    W eb Ser ver Commands 228 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • country — Specifies the country name. (Range: 2-2) • days — Specifies number of days cer tification is valid. (Range: 30-3650) Def ault Configuration The Certificate and SSL ’ s RSA key pairs do not exist. If no certificate numbe ...

  • Intel SBCEGBESW10 CLI - page 245

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 229 Pa r a m e t e r s • number — Specifies the c ertificate number . (Range: 1-2) • common- name — Specifies the fully qualified UR L or IP address of the de vice. (Range: 1- 64) • or ganization -unit — Specifies the organization -u ...

  • Intel SBCEGBESW10 CLI - page 246

    W eb Ser ver Commands 230 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example generates and disp lays a certificate request for HTTPS. crypto cer tificate impor t The crypto certificate import Glob al Configuration mode command import s a certificate signed by the Certifica tion Authority ...

  • Intel SBCEGBESW10 CLI - page 247

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 231 The imported certificate must be based on a ce rtificate request created by the crypto certificate request Privi leged EXEC mode comm and. If the public key found in the certificate does not match the device's SSL RSA key , the command ...

  • Intel SBCEGBESW10 CLI - page 248

    W eb Ser ver Commands 232 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration Certificate number 1. Command Mode Global Configuration mod e User Guidelines The crypto certificate generate command should be used to generate HTTPS certificates. Example The following example configures the active c ...

  • Intel SBCEGBESW10 CLI - page 249

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 233 Example The following example di splays the certificate. sho w ip http The show ip http Privileged EXEC mode com mand displays the HTTP server configuration. Syntax show ip http Def ault Configuration This command has no default configuratio ...

  • Intel SBCEGBESW10 CLI - page 250

    W eb Ser ver Commands 234 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the HTTP server configuration. sho w ip https The show ip https Privileged EXEC mod e comman d displays the HTTPS server configuration. Syntax show ip https Def ault Configuration This command has no de ...

  • Intel SBCEGBESW10 CLI - page 251

    W eb Ser ver Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 235 Certificate 2 is inactive Issued by: self-signed Valid from: 8/9/2004 to 8/9/2005 Subject: CN= router.gm.com, 0= General Motors, C= US Finger print: 1873B936 88DC3411 BC8932E F 782134BA ...

  • Intel SBCEGBESW10 CLI - page 252

    W eb Ser ver Commands 236 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 253

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 237 21 SNMP Commands snmp-server community The snmp-server community Global Configura tion mode command config ures the community access string to permit access to the SNMP protocol. T o remove the specified community string, use the no form of this command. Syntax s ...

  • Intel SBCEGBESW10 CLI - page 254

    SNMP Commands 238 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines The view-na m e parameter cannot be specified for su , which has access to the whole MIB. The view-name parameter can be used to restrict th e access rights of a community string. When it is specified: An internal security name is ge ...

  • Intel SBCEGBESW10 CLI - page 255

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 239 • oid-tr ee — Specifies the object identifier of the ASN.1 subtree to be included or excluded from the view . T o iden tify the subtree, specify a text string consisting of numbers, such as 1.3.6.2. 4, or a word, such as system. Replace a single ...

  • Intel SBCEGBESW10 CLI - page 256

    SNMP Commands 240 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no snmp-server gr oup gr oupname { v1 | v2 | v3 [ noauth | auth | priv ]} Pa r a m e t e r s • gr oupname —Specifies the name o f the group (Range: 1-30 characters). • v1 — Indicates the SNMP V ersion 1 se curity model. • v2 — Indicates ...

  • Intel SBCEGBESW10 CLI - page 257

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 241 Example The following example attaches a group called user-group to SNMPv3 and assigns to the group the privacy security level and read access rights to a view called user-view . snmp-server user The snmp-server user Global Con figuration mode co mm ...

  • Intel SBCEGBESW10 CLI - page 258

    SNMP Commands 242 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide if authentication and privacy ar e required, 36 bytes should be entered. Each byte in the hexadecimal character string is two hexadeci mal digits. Each byte can be separated by a period or colon. (20 or 36 bytes) Def ault Configuration No group entr ...

  • Intel SBCEGBESW10 CLI - page 259

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 243 Pa r a m e t e r s • engineid-string —Specifies a character string that identifies the engine ID. (Range: 5- 32 characters) • default —The engine ID is created automati cally based on the device MAC address. Def ault Configuration The engine ...

  • Intel SBCEGBESW10 CLI - page 260

    SNMP Commands 244 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The show running-config Privileged EXEC mode comman d does not display the SNMP engine ID configuration. T o see the SN MP engine ID configuration, en ter the snmp- server engineID local Global Configuration mode command . Example The following exam ...

  • Intel SBCEGBESW10 CLI - page 261

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 245 snmp-server filter The snmp-se rver filter Global Co nfiguration mode comm and create s or updates a Simple Network Management Protocol (SNMP) server filter entry . T o remove the specified SNMP server filter entry , use the no form of this command. ...

  • Intel SBCEGBESW10 CLI - page 262

    SNMP Commands 246 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide snmp-server host The snmp-server host Global Configuration mode comm and specifies the recipient of Simple Network Management Prot ocol V ersio n 1 or V ersion 2 notificatio ns. T o remove the specified host, use the no form of this command. Syntax ...

  • Intel SBCEGBESW10 CLI - page 263

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 247 Command Mode Global Configuration mode User Guidelines When configuring an SNMPv1 or SNMPv2 notif ication recipient, a notificat ion view for that recipient is automatica lly generated for all the MIB. When configuring an SNMPv1 notification recipie ...

  • Intel SBCEGBESW10 CLI - page 264

    SNMP Commands 248 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide • auth — Indicates authentication of a packet without encrypting it. • priv — Indicates authentication of a packet with encryption. • port — Specifies the UDP port of the host to use. If unspecified, the default UDP port number is 162. ( ...

  • Intel SBCEGBESW10 CLI - page 265

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 249 no snmp-server tr ap authentication Def ault Configuration SNMP failed authentica tion traps are enabled. Command Mode Global Configuration mode User Guidelines There are no user guidelines for this command. Example The following example enables SNM ...

  • Intel SBCEGBESW10 CLI - page 266

    SNMP Commands 250 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines Do not include spaces in the text string or pl ace text that includes spaces inside qu otation marks. Example The following example configures the system contact point called Intel_T echnical_Support . snmp-server location The snmp-s ...

  • Intel SBCEGBESW10 CLI - page 267

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 251 Example The following example defi nes the device location as New_Y o rk . snmp-server set The snmp-server set G lobal Configuration mo de command defines th e SNMP MIB value. Syntax snmp-server set variable-name name1 value1 [ name2 value2 … ] Pa ...

  • Intel SBCEGBESW10 CLI - page 268

    SNMP Commands 252 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w snmp The show snmp Privilege d EXEC mode command display s the SNMP status. Syntax show snmp Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for t ...

  • Intel SBCEGBESW10 CLI - page 269

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 253 The following table describes the significant fields shown in the display . sho w snmp engineid The show snmp engineID Privileged EXEC mode command di splays the ID of the local Simple Network Managemen t Protocol (SNMP) engine.Sy ntax show snmp eng ...

  • Intel SBCEGBESW10 CLI - page 270

    SNMP Commands 254 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays the SNMP engine ID. sho w snmp views The show snmp views Privileged EXEC mode command displays t he configuration ...

  • Intel SBCEGBESW10 CLI - page 271

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 255 Example The following example displays the configuration of views. sho w snmp groups The show snmp groups Privileged EXEC mode co mmand displays the configuration of groups. Syntax show snmp groups [ gr oupname ] Pa r a m e t e r s • gr oupn ame ? ...

  • Intel SBCEGBESW10 CLI - page 272

    SNMP Commands 256 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the config uration of views. The following table describes si gnificant fields shown above. sho w snmp filters The show snmp filters Privileged EXEC mode command di splays the configuration of filters. Syntax s ...

  • Intel SBCEGBESW10 CLI - page 273

    SNMP Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 257 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays the configuration of filters. sho w snmp users The show snmp users Privileged EXEC mod e command displays the con ...

  • Intel SBCEGBESW10 CLI - page 274

    SNMP Commands 258 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command.Example The following example displays the configuratio n of users. Console# show snmp users Name Group name Auth Method Remote ------ ------------ -- ------- ------------------------- Jo ...

  • Intel SBCEGBESW10 CLI - page 275

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 259 22 Spanning-T ree Commands spanning-tree The spanning-tree Global Con figuration mode co mmand enables spanning-tree functionality . T o disable the span ning-tree functionality , use the no form of this command. Syntax spanning-tree no spanning-tree Def ault Con ...

  • Intel SBCEGBESW10 CLI - page 276

    Spanning-T ree Commands 260 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no spanning-tr ee mode Pa r a m e t e r s • stp — Indicates that the Spanning T ree Protocol (STP) is enabled. • rstp — Indicates that the Rapid Sp anning T re e Protocol (RSTP) is enabled. • mstp — Indicates that the Multiple ...

  • Intel SBCEGBESW10 CLI - page 277

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 261 Pa r a m e t e r s seconds — T ime in seconds. (Range: 4-30) Def ault Configuration The default forwarding time for the IEEE Sp an ning Tree P rotocol (STP) is 15 seconds. Command Modes Global Configuration mode User Guidelines When conf ...

  • Intel SBCEGBESW10 CLI - page 278

    Spanning-T ree Commands 262 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Modes Global Configuration mod e User Guidelines When configuring the hello time, the following rela tionship should be kept: Max-Age >= 2*(Hello-T ime + 1) Example The following example configures spanning tree bridge hello tim ...

  • Intel SBCEGBESW10 CLI - page 279

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 263 2*(Forward-T ime - 1) >= Max-Age Max-Age >= 2*(Hello-T ime + 1) Example The following example conf igures the spanning tree bridge maximum-age to 10 seconds. spanning-tree priority The spanning-tree priority Global Configuration mode ...

  • Intel SBCEGBESW10 CLI - page 280

    Spanning-T ree Commands 264 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide spanning-tree disable The spanning-tree disable Interface Configuration mode command disables spanning tree on a specific port. T o enable spanning tree on a port, use the no form of this command. Syntax spanning-tree disable no spanning-t ...

  • Intel SBCEGBESW10 CLI - page 281

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 265 Pa r a m e t e r s • cost — Path cost of the port (Range: 1-20 0,000,000) Def ault Configuration Default path cost is determined by port speed and path cos t method (long or short) as shown below: Command Modes Interface Configuration ...

  • Intel SBCEGBESW10 CLI - page 282

    Spanning-T ree Commands 266 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • priority — The priority of the port. (Range: 0-240 in multiples of 16) Def ault Configuration The default port priority for IEEE Spanning T reeProtocol (STP) is 128. Command Modes Interface Configuration (Eth ernet ...

  • Intel SBCEGBESW10 CLI - page 283

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 267 Command Modes Interface Configuration (Eth ernet, port-channel ) mode User Guidelines This feature should be used on ly with interfaces conn ected to end sta tions. Otherwise, an accidental topology loop could cause a data packet loop an d ...

  • Intel SBCEGBESW10 CLI - page 284

    Spanning-T ree Commands 268 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command. Example The following example enables shared spanning-tre e on Ethernet port 15 . spanning-tree pathcost method The spanning-tree pathcost method Global Configuratio n mode com ...

  • Intel SBCEGBESW10 CLI - page 285

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 269 Example The following example sets the default path cost method to long . spanning-tree bpdu The spanning-tree bpdu Global Configuration mode command define s BPDU handling when the spanning tree is disabled globally or on a single interfa ...

  • Intel SBCEGBESW10 CLI - page 286

    Spanning-T ree Commands 270 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide c lear spanning-tree detected-pr otocols The clear spanning-tree detected-pr otocols Privileged EXEC mode command restarts the protocol migration process (fo rces rene gotiation with neighbori ng devices) on all interfaces or on a specifie ...

  • Intel SBCEGBESW10 CLI - page 287

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 271 no spanning-tree mst instance-id priority Pa r a m e t e r s • instance -id— ID of the spanning -tree instance (Range: 1-15). • priority— Device priority for the sp ecified spanning-tree inst ance (Range: 0-61 440 in multiples of 4 ...

  • Intel SBCEGBESW10 CLI - page 288

    Spanning-T ree Commands 272 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration The default number of hop s is 20. Command Mode Global Configuration mod e User Guidelines There are no user guidelines for this command. Example The following example configures the maximum number of hops that a pac ...

  • Intel SBCEGBESW10 CLI - page 289

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 273 User Guidelines There are no user guidelines for this command. Example The following example conf igures the port priority of port g1 to 144. spanning-tree mst cost The spanning-tree mst cost Interface Configuration mode command co nfigure ...

  • Intel SBCEGBESW10 CLI - page 290

    Spanning-T ree Commands 274 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines There are no user guidelines for this command. Example The following example conf igures the MSTP instance 1 path cost for Ethernet port 9 to 4. spanning-tree mst configuration The spanning-tree mst configuration Global Con ...

  • Intel SBCEGBESW10 CLI - page 291

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 275 instance (mst) The instance MST Configuration mode comm and maps VLANS to an MST instance. Syntax instance instance-id {add | remove} vlan vlan-range Pa r a m e t e r s • instance-ID— ID of the MST instance (Range : 1-15). • vlan-ran ...

  • Intel SBCEGBESW10 CLI - page 292

    Spanning-T ree Commands 276 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide name (mst) The name MST Configuration mode command defines the configuration name. T o restore the default setting, use the no form of this command. Syntax name string Pa r a m e t e r s • string — MST configuration name. The name is c ...

  • Intel SBCEGBESW10 CLI - page 293

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 277 Pa r a m e t e r s • value — Configuration revisio n number (Range: 0-65535). Def ault Configuration The default configuratio n revision number is 0. Command Mode MST Configuration m ode User Guidelines There are no user guidelines for ...

  • Intel SBCEGBESW10 CLI - page 294

    Spanning-T ree Commands 278 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode MST Configuration mode User Guidelines The pending MST region configuration take s effect only after exiting the MST Configuration mode. Example The following example displays a pendin g MST region configuration. ex i t ( m s ...

  • Intel SBCEGBESW10 CLI - page 295

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 279 Example The following example exits the MST Co nfiguration mode an d saves changes. abor t (mst) The abort MST Configuration mode command ex its the MST Configuration mode without applying t h e configuration ch anges. Syntax abort Def aul ...

  • Intel SBCEGBESW10 CLI - page 296

    Spanning-T ree Commands 280 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax spanning-tr ee guard root no spanning-tr ee guard root Def ault Configuration Root guard is disabled. Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines Root guard can be enabled when the device oper ...

  • Intel SBCEGBESW10 CLI - page 297

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 281 • port-channel-number — A valid po rt channel number . • detail — Indicates detailed information. • active — Indicates active ports only . • blockedports — Indicates blocked po rts only . • mst-configuration — Indicates ...

  • Intel SBCEGBESW10 CLI - page 298

    Spanning-T ree Commands 282 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Interfaces Name State Prio.Nbr Cost Sts Role PortFast Type ---- ------- -------- ----- --- ---- -------- ---------- 1 Enabled 128.1 20000 F WD Roo t No P2p bound(RSTP) 2 Enabled 128.2 20000 FWD Desg No Shared (STP) 3 Disabled 128.3 20000 - ...

  • Intel SBCEGBESW10 CLI - page 299

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 283 Console# show spanning-tree Spanning tree disabled (BPDU f iltering) mode RSTP Default port cost method: long Root ID Priority N/A Address N/A Path Cost N/A Root Port N/A Hello Time N/A Max Age N/ A Forward Delay N/A Bridge ID Priority 368 ...

  • Intel SBCEGBESW10 CLI - page 300

    Spanning-T ree Commands 284 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Address 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interfaces Name State Prio.Nbr Cost Sts Role PortFast Type ---- ------- -------- ----- --- ---- -------- ---------- 1 Enabled 128.1 20000 F WD Roo t No P2p (RST ...

  • Intel SBCEGBESW10 CLI - page 301

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 285 Console# show spanning-tree detail Spanning tree enabled mode RSTP Default port cost method: long Root ID Priority 32768 Address 00:01:42:97:e0:00 Path Cost 20000 Root Port 1 (1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridg ...

  • Intel SBCEGBESW10 CLI - page 302

    Spanning-T ree Commands 286 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Port 3 disabled State: N/A Role: N/A Port id: 128.3 Port cost: 20000 Type: N/A (configured: auto ) Port Fast : N/A (configured:no) Designated bridge Priority: N/A Address: N/A Designated port id: N/A Designated path cost: N/A Number of tra ...

  • Intel SBCEGBESW10 CLI - page 303

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 287 Console# show spanning-tree ethernet ext.1 Port 1 (1/1) enabled State: Forwarding Role: Root Port id: 128.1 Port cost: 20000 Type: P2p (configured: auto) R STP Port Fast: No (configured:no ) Designated bridge Priority: 32 768 Address: 00:0 ...

  • Intel SBCEGBESW10 CLI - page 304

    Spanning-T ree Commands 288 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Max hops 20 Interfaces Name State Prio.Nbr Cost Sts Role PortFast Type ---- ------- -------- ----- --- ---- -------- ---------- 1 Enabled 128.1 20000 F WD Roo t No P2p Bound (RSTP) 2 Enabled 128.2 20000 FWD Desg No Shared Bound (STP) 3 Ena ...

  • Intel SBCEGBESW10 CLI - page 305

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 289 Console# show spanning-tree detail Spanning tree enabled mode MSTP Default port cost method: long ###### MST 0 Vlans Mapped: 1-9 , 21-4094 CST Root ID Priority 32768 Address 00:01:42:97:e0:00 Path Cost 20000 Root Port 1 (1/1) Hello Time 2 ...

  • Intel SBCEGBESW10 CLI - page 306

    Spanning-T ree Commands 290 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Designated port id: 128.2 Designated path cost: 20000 Number of transitions to fo rwarding state: 1 BPDU: sent 2, received 1706 38 Port 3 enabled State: Forwarding Role: Designated Port id: 128.3 Port cost: 20000 Type: Shared (configured: ...

  • Intel SBCEGBESW10 CLI - page 307

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 291 Port 1 (1/1) enabled State: Forwarding Role: Boundary Port id: 128.1 Port cost: 20000 Type: P2p (configured: auto) B oundary RSTP Port Fast: No (configured:no) Designated bridge Priority: 32 768 Address: 00:02:4b:29:7a:00 Designated port i ...

  • Intel SBCEGBESW10 CLI - page 308

    Spanning-T ree Commands 292 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Console# show spanning-tree Spanning tree enabled mode MSTP Default port cost method: l ong ###### MST 0 Vlans Mapped: 1-9, 21-4094 CST Root ID Priority 32768 Address 00:01:42:97:e0:00 Path Cost 20000 Root Port 1 (1/1) Hello Time 2 sec Max ...

  • Intel SBCEGBESW10 CLI - page 309

    Spanning-T ree Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 293 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Max hops 20 ...

  • Intel SBCEGBESW10 CLI - page 310

    Spanning-T ree Commands 294 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 311

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 295 23 SSH Commands ip ssh por t The ip ssh port Global Configu ration mode command specifies the port to be used by the SSH server . T o restore the default configuratio n, use the no form of this command. Syntax ip ssh port port-number no ip ssh po rt Pa r a m e t ...

  • Intel SBCEGBESW10 CLI - page 312

    SSH Commands 296 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax ip ssh server no ip ssh server Def ault Configuration Device configuration from a SSH server is disabled. Command Mode Global Configuration mod e User Guidelines If encryption keys are not generate d, the SSH server is in standby until the key ...

  • Intel SBCEGBESW10 CLI - page 313

    SSH Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 297 User Guidelines DSA keys are generated in pairs: o n e public DSA key and o n e private DSA key . If the device already has DSA keys, a warning and prompt to replace the existing keys with new keys are displa yed. This command is not saved in th e de ...

  • Intel SBCEGBESW10 CLI - page 314

    SSH Commands 298 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide RSA keys are saved to the backup m a ster . This command may tak e a consider able period of time to execute. Example The following example ge nerates RSA key pairs. ip ssh pubke y-auth The ip ssh pubkey-auth Global Co nfiguration mode command enable ...

  • Intel SBCEGBESW10 CLI - page 315

    SSH Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 299 crypto key pubke y-chain ssh The crypto key pubkey-chain ssh Global Conf iguration mode command enters the SSH Public Key-chain Co nfiguration mode. The mode is used to manually specify other device public keys such as SSH client public keys. Syntax ...

  • Intel SBCEGBESW10 CLI - page 316

    SSH Commands 300 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide user -key The user -key SSH Public Key-string Configuratio n mode command specifies which SSH public key is manually configured . T o remove an SSH public key , use the no form of this command. Syntax user-key usern ame { rsa | dsa } no user-key user ...

  • Intel SBCEGBESW10 CLI - page 317

    SSH Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 301 ke y-string The key-string SSH Public Key-stri ng Configuration m ode command manually specifies an SSH public key . Syntax key-string key-string row key-string Pa r a m e t e r s • row — Indicates the SSH publi c key row by row . • key-string ...

  • Intel SBCEGBESW10 CLI - page 318

    SSH Commands 302 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example enters pu blic key strings for SSH public key clie nt bob . sho w ip ssh The show ip ssh Privileg ed EXEC mode command displa ys the SSH server configuratio n. Syntax show ip ssh Def ault Configuration This command has n ...

  • Intel SBCEGBESW10 CLI - page 319

    SSH Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 303 User Guidelines There are no user guidelines for this command. Example The following example displays the SSH server configuration. The following table describes the significant fields shown in the display . sho w crypto key m ypubke y The show crypt ...

  • Intel SBCEGBESW10 CLI - page 320

    SSH Commands 304 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays th e SSH public RSA keys on the device. sho w cr ...

  • Intel SBCEGBESW10 CLI - page 321

    SSH Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 305 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example display s SSH public keys stored on the device. Console# show crypto key pubkey-chain ssh Username Fingerprint -------- --- ...

  • Intel SBCEGBESW10 CLI - page 322

    SSH Commands 306 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 323

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 307 24 Syslog Commands logging on The logging on Global Configuration mode comman d controls error message logging . This command sends debug or error messages to a logging process, which logs messages to designated locations asynch ronously to the process that gener ...

  • Intel SBCEGBESW10 CLI - page 324

    Syslog Commands 308 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide logging The logging Global Configuration m ode command logs messages to a syslog server . T o delete the syslog server with the specified address from the list of syslogs, use the no form of this command. Syntax logging { ip-addr ess | hostname } ...

  • Intel SBCEGBESW10 CLI - page 325

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 309 Example The following example limits logg ed messages sent to the sysl og server with IP address 10.1.1.1 to severity level critical . logging b uffered The logg ing buffered Global Configu ration mode co mmand limits syslog messages displayed fro ...

  • Intel SBCEGBESW10 CLI - page 326

    Syslog Commands 310 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide logging b uffered size The logging buffered size Global Configuration mode co mmand changes the number of syslog messages stored in the internal buf fer . T o restore the default configuration, use the no form of this command. Syntax logging buffe ...

  • Intel SBCEGBESW10 CLI - page 327

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 311 Syntax clear logging Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example clears message s from the interna ...

  • Intel SBCEGBESW10 CLI - page 328

    Syslog Commands 312 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Global Configuration mod e User Guidelines There are no user guidelines for this command. Example The following example limits syslog messages se nt to the logging file based on severity level alerts . c lear logging file The clear lo ...

  • Intel SBCEGBESW10 CLI - page 329

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 313 aaa logg ing The aaa logging Global Configuration m ode command enables loggin g AAA login events. T o disable logging AAA login events, use the no form of this command. Syntax aaa logging l ogin no aaa logging log in Pa r a m e t e r s • login ...

  • Intel SBCEGBESW10 CLI - page 330

    Syslog Commands 314 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no file-system logging copy file-system logging delete-r ename no file-system logging delete-r ename Pa r a m e t e r s • copy — Indicates logging messages rela ted to file copy operations. • delete-rename — Indicates logging messages rela ...

  • Intel SBCEGBESW10 CLI - page 331

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 315 Pa r a m e t e r s • deny — Indicates logging messages related to deny actions of man a gement ACLs. Def ault Configuration Logging management ACL events is enabled. Command Mode Global Configuration mode User Guidelines Other types of managem ...

  • Intel SBCEGBESW10 CLI - page 332

    Syslog Commands 316 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the state of lo gging and the syslog messages s tored in the internal buffer . Console# show logging Logging is enabled. Console logging: level debu gging. Console Messages: 0 Dropped (severity). Buffer loggi ...

  • Intel SBCEGBESW10 CLI - page 333

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 317 sho w logging file The show logging file Privileged EXEC m ode command displays the state of l ogging and the syslog messages stored in the logging file. Syntax show logging file Def ault Configuration This command has no default configuration. Co ...

  • Intel SBCEGBESW10 CLI - page 334

    Syslog Commands 318 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w syslog-ser vers The show syslog-servers Privileged EXEC mode comma nd displays the settings of the syslog servers. Syntax show syslog-servers Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode ...

  • Intel SBCEGBESW10 CLI - page 335

    Syslog Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 319 Example The following example displays th e settings of the syslog servers. Console# show syslog-servers Device Configuration IP address Port Severity Facility Description ------------ ---- ------------- -------- ----------- 192.180.2.27 514 Infor ...

  • Intel SBCEGBESW10 CLI - page 336

    Syslog Commands 320 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 337

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 321 25 System Management Commands ping The ping User EXEC mode command sends ICMP echo request packets to another node on the network. Syntax ping { ip-address | hostname }[ size packet_size ] [ count packet_count ] [ timeout time_out ] Pa ...

  • Intel SBCEGBESW10 CLI - page 338

    System Management Command s 322 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Destination does n o t respond. If the host does n ot respond, a “no answer from host” appears in ten seconds. Destination unreachable. The gateway for this de sti n ation indicates that the destination is unreachable. Network or h ...

  • Intel SBCEGBESW10 CLI - page 339

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 323 Syntax traceroute { ip-address | hostname }[ size packet_size ] [ ttl max-ttl ] [ count packet_count ] [ timeout time_out ] [ sour ce ip-address ] [ tos tos ] Pa r a m e t e r s • ip-address — IP address of the destination host. ? ...

  • Intel SBCEGBESW10 CLI - page 340

    System Management Command s 324 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The tracer oute command sends ou t one probe at a time. Each outgoing packet may result in one or two error m essages. A "time ex ceeded" error message indicates that an intermediate device has seen and discard ed th e probe. ...

  • Intel SBCEGBESW10 CLI - page 341

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 325 telnet The telnet User EXEC mode command enables logging on to a host that supports T elnet. Syntax telnet { ip-address | hostna me } [ port ] [ keyword1. ..... ] Pa r a m e t e r s • ip-address — IP address of the destination host ...

  • Intel SBCEGBESW10 CLI - page 342

    System Management Command s 326 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Special T elnet Sequences At any time during an active T e lnet session, T elne t commands can be listed by pres sing the Ctrl-shift-6-? keys at the system prompt. A sample of this list follows. Note that the Ct rl-shi ft-6 sequence ap ...

  • Intel SBCEGBESW10 CLI - page 343

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 327 Ports T able This command lists concurrent te lnet connections to remote ho sts that were opened by the current telnet session to the lo cal device. It does not list teln et connections to remote hosts that were opened by other telnet ...

  • Intel SBCEGBESW10 CLI - page 344

    System Management Command s 328 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example display s connecting to 176.213.10.50 v ia T elnet. resume The resume User EXEC mode command enables switching to another open T elnet session. Syntax res u m e [ connection ] Pa r a m e t e r s • connec ...

  • Intel SBCEGBESW10 CLI - page 345

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 329 Syntax rel o a d Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines Caution should be exercised when resetting the device, to ensure that no other activity is being perfo ...

  • Intel SBCEGBESW10 CLI - page 346

    System Management Command s 330 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Global Configuration mod e User Guidelines There are no user guidelines for this command. Example The following example specifies the device host name. sho w users The show users User EXEC mode command displays information ...

  • Intel SBCEGBESW10 CLI - page 347

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 331 sho w sessions The show sessions User EXEC mode command lists open T elnet sessions. Syntax show sessions Def ault Configuration There is no default co nfiguration for this command. Command Mode User EXEC mode User Guidelines There are ...

  • Intel SBCEGBESW10 CLI - page 348

    System Management Command s 332 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide sho w system The show system User EXEC mode command displays system information. Syntax show system Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines There are no user guideli ...

  • Intel SBCEGBESW10 CLI - page 349

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 333 sho w system id The show system id Privilaged EXEC mode command displays the sy stem identity information. Syntax show system id [ unit unit ] Pa r a m e t e r s • unit unit — Unit number . Def ault Configuration This command has n ...

  • Intel SBCEGBESW10 CLI - page 350

    System Management Command s 334 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example sho w system flowcontr ol The show system flowcontrol Interface Configuration mode command displays the flow control state on cascade ports. Syntax show system flowcontr ol Def ault Configuration This command has no default con ...

  • Intel SBCEGBESW10 CLI - page 351

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 335 Example sho w system mode The show system mode Priviledged EXEC mode comm and displays informat ion on features control. Syntax show system mode Def ault Configuration This command has no default configuration. Command Mode Priviledged ...

  • Intel SBCEGBESW10 CLI - page 352

    System Management Command s 336 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax show version Def ault Configuration This command has no default configuration. Command Mode User EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays system version info ...

  • Intel SBCEGBESW10 CLI - page 353

    System Management Command s Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 337 Def ault Configuration Disabled. Command Mode Global Configuration mode User Guidelines Use the show cpu utilization Privileged EXEC command to view information on CPU utilization. Example This example enables measuring CPU utilization ...

  • Intel SBCEGBESW10 CLI - page 354

    System Management Command s 338 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example conf igures the CPU utilizatio n information display. Console# show cpu utilization CPU utilization service is on. CPU utilization ------------------------------------ -------------- five seconds: 5%; one ...

  • Intel SBCEGBESW10 CLI - page 355

    T ACA CS+ Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 339 26 T A CA CS+ Commands tacacs-server host The tacacs-serve r host Global Configuration mode command specifies a T ACACS+ host. T o delete the specifie d name or address, use the no form of this command. Syntax tacacs-server host { ip-addr ess | ...

  • Intel SBCEGBESW10 CLI - page 356

    T ACA CS+ Commands 340 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide If no T ACACS+ server priority is sp ecified, default priority 0 is used. Command Mode Global Configuration mod e User Guidelines Multiple tacacs-server host commands can be used to specify multiple hosts. Example The following example specifie ...

  • Intel SBCEGBESW10 CLI - page 357

    T ACA CS+ Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 341 User Guidelines There are no user guidelines for this command. Example The following example sets th e authentication encryption key . tacacs-server timeout The tacacs-server timeout Global Configuration mode comm and sets the interval during w ...

  • Intel SBCEGBESW10 CLI - page 358

    T ACA CS+ Commands 342 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide tacacs-server source-ip The tacacs-server sour ce-ip Global Configuration mode command configures the source IP address to be used for co mmunication with T ACACS+ server s. T o return to the default configuration, use the no form of this comma ...

  • Intel SBCEGBESW10 CLI - page 359

    T ACA CS+ Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 343 Pa r a m e t e r s • ip-address — Name or IP address of the T ACACS+ server . Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. ...

  • Intel SBCEGBESW10 CLI - page 360

    T ACA CS+ Commands 344 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 361

    User Interf ace Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 345 27 User Interface Commands enable The enable User EXEC mode command ente rs the Privileged EXEC mode. Syntax enable [ privilege-level ] Pa r a m e t e r s • privilege-level — Privilege level to ente r the system. (Range: 1-15) Def aul ...

  • Intel SBCEGBESW10 CLI - page 362

    User Interf ace Commands 346 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Syntax disable [ privilege-level ] Pa r a m e t e r s • privilege-level — Privilege level to ente r the system. (Range: 1-15) Def ault Configuration The default privilege level is 1. Command Mode Privileged EXEC mode User Guidelines T ...

  • Intel SBCEGBESW10 CLI - page 363

    User Interf ace Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 347 User Guidelines There are no user guidelines for this command. Example The following example enters Privileged EX EC mode and logs in with username admin . configure The configure Privileged EXEC mode command ente rs the Global Configurat ...

  • Intel SBCEGBESW10 CLI - page 364

    User Interf ace Commands 348 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide e xit (Configuration) The exit command exits any configuration mode to the next highest mode in the CLI mode hierarchy . Syntax exit Def ault Configuration This command has no default configuration. Command Mode All configuration modes Us ...

  • Intel SBCEGBESW10 CLI - page 365

    User Interf ace Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 349 Command Mode Privileged and User EXEC mode s User Guidelines There are no user guidelines for this command. Example The following exampl e closes an active terminal session. end The end command ends the current configuratio n session and ...

  • Intel SBCEGBESW10 CLI - page 366

    User Interf ace Commands 350 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide help The help command displays a brief description of the help system. Syntax help Def ault Configuration This command has no default configuration. Command Mode All command modes User Guidelines There are no user guidelines for this comm ...

  • Intel SBCEGBESW10 CLI - page 367

    User Interf ace Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 351 Syntax terminal datadump no terminal data dump Def ault Configuration Dumping is disabled. Command Mode User EXEC mode User Guidelines By default, a Mor e prompt is disp layed when the outp ut contains more lines than can be displayed on ...

  • Intel SBCEGBESW10 CLI - page 368

    User Interf ace Commands 352 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode User EXEC mode User Guidelin es The buffer includes executed and unexecuted commands. Commands are listed from the firs t to the most rec ent command. The buffer remains unchange d when entering into and returning from config ...

  • Intel SBCEGBESW10 CLI - page 369

    User Interf ace Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 353 Command Mode Privileged and User EXEC mode s User Guidelines There are no user guidelines for this command. Example The following example displays the current pr ivilege level for the Privileged EXEC mode. do The do command executes an EX ...

  • Intel SBCEGBESW10 CLI - page 370

    User Interf ace Commands 354 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example displays the current pr ivilege level for the Privileged EXEC mode. Console (Config)# do show vlan V LAN Name Ports Type Authorization -------- --------------- ------ ----- -------------- 1 default 1/1-2 Othe ...

  • Intel SBCEGBESW10 CLI - page 371

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 355 28 VLAN Commands vlan database The vlan database Global Configuration mode command enters the VLAN Configuration mode. Syntax vlan database Def ault Configuration This command has no default configuration. Command Mode Global Configuration mode User ...

  • Intel SBCEGBESW10 CLI - page 372

    VLAN Commands 356 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • vlan-range — Specifies a lis t of VLAN IDs to be added. Separate nonconsecutive VLAN IDs with a comma an d no spaces; a hyphen des ignates a range of IDs . Def ault Configuration This command has no default configuration. Co ...

  • Intel SBCEGBESW10 CLI - page 373

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 357 User Guidelines There are no user guidelines for this command. Example The following example conf igures VLAN 1 with IP address 131.108.1.27 an d subnet mask 255. 255.255.0. interface range vlan The interface range vlan Global Configuration mode co ...

  • Intel SBCEGBESW10 CLI - page 374

    VLAN Commands 358 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example grou ps VLANs 221, 228 and 889 to receive the sam e command. name The name Interface Configuration mode command ad ds a name to a VLAN. T o remove the VLAN name, use the no form of this command. Syntax name string no na ...

  • Intel SBCEGBESW10 CLI - page 375

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 359 s w itchpor t pr otected The switchport protected Interface Configuration mode command overrides the FDB decision, and sends all Unicas t, Multicast and Broadcast traf fic to an uplink port. T o disable overriding the FDB decision, use th e no form ...

  • Intel SBCEGBESW10 CLI - page 376

    VLAN Commands 360 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide s witchpor t mode The switchport mode Interface Configuration mode co mmand configures the VLAN membership mode of a port. T o return to the default configuration, use the no form of this command. Syntax switchport mode { access | trunk | general } ...

  • Intel SBCEGBESW10 CLI - page 377

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 361 Syntax switchport access vlan { vlan-id | dynamic } no switchport access vlan Pa r a m e t e r s • vlan-id — Specifies the ID of the VLAN to which the port is configured. • dynami c —Indicates that the port is assigned to a VL AN based on th ...

  • Intel SBCEGBESW10 CLI - page 378

    VLAN Commands 362 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Pa r a m e t e r s • add vlan-list — List of VLAN IDs to b e added. Separate nonconsecutiv e VLAN IDs with a comma and no spaces. A hyphen designates a range of IDs. • rem o v e vlan-list — List of VLAN IDs to be removed. Sepa rate nonconsec ...

  • Intel SBCEGBESW10 CLI - page 379

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 363 Def ault Configuration VID=1. Command Mode Interface Configuration (Eth ernet, port-channel ) mode User Guidelines The command adds the port as a member in th e VLAN. If the port is already a member in the VLAN (not as a native), it shou ld be first ...

  • Intel SBCEGBESW10 CLI - page 380

    VLAN Commands 364 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration If the port is added to a VLAN without specifying tagged or untagg ed, the default setting is tagged. Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines This comman d enables changing the egres ...

  • Intel SBCEGBESW10 CLI - page 381

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 365 User Guidelines There are no user guidelines for this command. Example The following example configures the PVID for Ethernet port 1, when the interface is in general mode. s witchpor t g eneral ingress-filtering disable The switchport general ingre ...

  • Intel SBCEGBESW10 CLI - page 382

    VLAN Commands 366 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide s witchpor t g eneral acceptable-frame-type tag g ed-onl y The switchport general acceptab le-frame-type tagged-only Interface Configuration mode command discards untagged fram e s at ingress. T o return to the default configuration, use the no form ...

  • Intel SBCEGBESW10 CLI - page 383

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 367 Pa r a m e t e r s • add vlan-list — Specifies the list of VLAN IDs to be added. Separate nonconsecutive VLAN IDs with a comma a nd no spaces. A hyphen designates a range of IDs. • rem o ve vlan-list — Specifies th e list of VLAN IDs to be r ...

  • Intel SBCEGBESW10 CLI - page 384

    VLAN Commands 368 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration The software reserves a VLAN as the internal usage VLAN of an interface. Command Mode Interface Configuration (Eth ernet, port-channel) mode User Guidelines An internal usage VLAN is required when an IP interface is config ure ...

  • Intel SBCEGBESW10 CLI - page 385

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 369 • vlan-name — Specifies a VLAN name string. (Range: 1-32 characters) Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The f ...

  • Intel SBCEGBESW10 CLI - page 386

    VLAN Commands 370 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays VLANs used internally by the device. sho w inte ...

  • Intel SBCEGBESW10 CLI - page 387

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 371 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example display s the switchport configuration for Ethernet port 1.map Console# show interface switchport ethe rnet ext.1 Port 1: ...

  • Intel SBCEGBESW10 CLI - page 388

    VLAN Commands 372 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ---- ------- ----------- 1 default untagged 11 VLAN011 tagged 19 IPv6 VLAN untagged 72 VLAN0072 untagged Forbidden VLANS: VLAN Name ---- ---- 73 out Console # show interface switchport e thernet ext.1 Port 1: VLAN Membership mode: General Operating ...

  • Intel SBCEGBESW10 CLI - page 389

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 373 map pr otocol pr otocols-group The map pro tocol protocols-gr oup VLAN database command adds a special protocol to a named group of protocols, which may be used for protocol-based VLAN assignment. T o delete a protocol from a group, use the no form ...

  • Intel SBCEGBESW10 CLI - page 390

    VLAN Commands 374 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode VLAN Database mode User Guidelines The following protocol na mes are reserved: • ip-arp • ipx Example The following example maps protocol ip-arp to the group named "213". s witchpor t g eneral map pr otocols-group vlan The ...

  • Intel SBCEGBESW10 CLI - page 391

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 375 User Guidelines There are no user guidelines for this command. Example The following example sets a proto col-based classification rule of protocol group 1 to VLAN 8. map mac macs-gr oup Use the map mac macs-group VLAN configuration command to map a ...

  • Intel SBCEGBESW10 CLI - page 392

    VLAN Commands 376 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example maps the MAC address 00:13:20:95:2 1:AA to macs group 4. s witchpor t g eneral map macs-gr oup vlan Use the swit chport gener al map macs-group vlan interface configuration command to set a mac- based classification rul ...

  • Intel SBCEGBESW10 CLI - page 393

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 377 map subnet subnets-gr oup Use the map subnet subn ets-group VLAN configuration command to map IP subnet to a group of IP subnets. Use the no form of this command to delete the map. Syntax map subnet ip-address prefix-mask subnet s-group group no map ...

  • Intel SBCEGBESW10 CLI - page 394

    VLAN Commands 378 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide no switchpo rt general map subnets-group group Pa r a m e t e r s • group - Group number . Ran ge: 1 - 2147483647 • vlan-id - Defin e the VLAN ID that is associated with the rule. Def ault Configuration This command has no default configuration. ...

  • Intel SBCEGBESW10 CLI - page 395

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 379 Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays protocols-groups informa tion. sho w vlan macs-groups Use the show vlan prot ocols-group s EXEC command to show p ...

  • Intel SBCEGBESW10 CLI - page 396

    VLAN Commands 380 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example disp lays protocols-groups information. sho w vlan subnets-groups Use the show vlan subnets-gr o ups EXEC command to show subnets-groups information. Syntax show vlan subnets-group s Pa r a m e t e r s • console — C ...

  • Intel SBCEGBESW10 CLI - page 397

    VLAN Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 381 Example The following exam ple shows subnets-groups information. onsole> show vlan subnets-grou ps MAC Prefix Group ------------------------------ ------- 172.16.1.0 255.255.255.01 172.16.2.0 255.255.255.02# ...

  • Intel SBCEGBESW10 CLI - page 398

    VLAN Commands 382 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

  • Intel SBCEGBESW10 CLI - page 399

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 383 29 802.1x Commands aaa authentication dot1x The aaa authentication dot1x Global Configuration mode command specifies one or more authentication, authorization, and acc ounting (AAA) methods for use on interfaces running IEEE 802.1x. T o return to ...

  • Intel SBCEGBESW10 CLI - page 400

    802.1x Commands 384 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example uses the aaa authentication dot1x default command with no authentication. dot1x system-auth-contr ol The dot1x system-auth-control Global Configuration mode command enab les 802.1x globally . T o return to the de faul ...

  • Intel SBCEGBESW10 CLI - page 401

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 385 Syntax dot1x port-control { auto | force-authorized | force-unauthorized } no dot1x port-control Pa r a m e t e r s • auto — Enables 802.1x authentication on the interface and causes the port to transition to the authorized or unauthorized sta ...

  • Intel SBCEGBESW10 CLI - page 402

    802.1x Commands 386 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide dot1x re-authentication The dot1x re-authentication Interface Configuration mode command enab les periodic re-authentication of the client. T o return to the default configuration, use the no form of this command. Syntax dot1x re-authentication no ...

  • Intel SBCEGBESW10 CLI - page 403

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 387 Pa r a m e t e r s • seconds — Number of seconds between re-authentication attempts. (Range: 300-4294967295) Def ault Configuration Re-authentication period is 3600 seconds. Command Mode Interface Configuration (Ethernet) mode User Guidelines ...

  • Intel SBCEGBESW10 CLI - page 404

    802.1x Commands 388 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following command manually initiates a re-a uthentication of 802.1x-enabled Ethernet port 16. dot1x timeout quiet-period The dot1x timeout ...

  • Intel SBCEGBESW10 CLI - page 405

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 389 The default value of this command should only be changed to adjust for unusual circumstances, such as unreliable links or specific behavioral problems with certain clients and authentication servers. T o provide a faster response time to the us er ...

  • Intel SBCEGBESW10 CLI - page 406

    802.1x Commands 390 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines The default value of this command should be changed only to adjust for unusual circumstances, such as unreliable links or specific behavioral problems with certain clients. and authentication servers Example The following command s ...

  • Intel SBCEGBESW10 CLI - page 407

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 391 User Guidelines The default value of this command should be changed only to adjust for unusual circumstances, such as unreliable links or specific behavioral problems with certain clients. and auth entication servers Example The following example ...

  • Intel SBCEGBESW10 CLI - page 408

    802.1x Commands 392 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Example The following example sets the timeout period before retransm itting an EAP-request frame to the client to 3600 seconds. dot1x timeout server -timeout The dot1x timeout server -timeout Interface Configuration mo de command sets the time th ...

  • Intel SBCEGBESW10 CLI - page 409

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 393 sho w dot1x The show dot1x Privileged EXEC mode command d isplays the 802.1x status of the device or specified interface. Syntax show dot1x [ ethernet interface ] Pa r a m e t e r s • interface — V alid Ethernet port. (Full syntax: unit/port ) ...

  • Intel SBCEGBESW10 CLI - page 410

    802.1x Commands 394 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following table describes si gnificant fields shown above: * Port is down or not present. Console# show dot1x ethernet ext.3 802.1x is enabled. Port Admin Mode Oper Mode Reauth Control Reauth Period Username ---- ---------- --------- ------- - ...

  • Intel SBCEGBESW10 CLI - page 411

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 395 sho w dot1x users The show dot1x users Privileged EXEC mode comm and displays active 802.1 x authenticated users for the device. Syntax show dot1x users [ username username ] Pa r a m e t e r s • username — Supplicant username (Range: 1-160 ch ...

  • Intel SBCEGBESW10 CLI - page 412

    802.1x Commands 396 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Def ault Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines There are no user guidelines for this command. Example The following example displays 80 2.1x users. The following table describes ...

  • Intel SBCEGBESW10 CLI - page 413

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 397 sho w dot1x statistics The show dot1x statistics Privileged EXEC mo de command di splays 802.1x statistics for the specified interface. Syntax show dot1x statistics ethe rnet interface Pa r a m e t e r s • interface — V alid Ethernet port. (Fu ...

  • Intel SBCEGBESW10 CLI - page 414

    802.1x Commands 398 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide The following table describes the sign ificant fields shown in the display: AD V ANCED FEA TURES dot1x auth-not-req The dot1x auth-not-req Interface Co nfiguration mode command enables unautho rized devices access to the VLAN. T o disable acce ss ...

  • Intel SBCEGBESW10 CLI - page 415

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 399 Def ault Configuration Access is enabled. Command Mode Interface Configuration (VLAN) mode User Guidelines An access port cannot be a memb er in an unauthenticated VLAN. The native VLAN o f a trunk port cannot be an unauthenticated VLAN. For a gen ...

  • Intel SBCEGBESW10 CLI - page 416

    802.1x Commands 400 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide User Guidelines This command enable s the attachment of multiple client s to a sing le 802.1x-enabled port. In this mode, only one of the attached hosts must be successf ully authorized for all hosts to be granted network access. If th e port b ec ...

  • Intel SBCEGBESW10 CLI - page 417

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 401 No traps are sent. Command Mode Interface Configuration (Ethernet) mode User Guidelines The command is relevant when multiple ho sts is disabled and the user has been successfully authenticated. Example The following example forwards frames with s ...

  • Intel SBCEGBESW10 CLI - page 418

    802.1x Commands 402 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide If the guest VLAN is defined and enabled, the port automatically joins the guest VLAN when the port is unauthorized and leaves it wh en the port becomes authorized. T o be able to join or leave the guest VLAN, t h e port sh ould not be a static me ...

  • Intel SBCEGBESW10 CLI - page 419

    802.1x Commands Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 403 Example The following example enables unauthorized users on Ethernet port 1 to access the guest VLAN. sho w dot1x adv anced The show dot1x adv anced Privileged EXEC mode command display s 802.1x advanced features for the device or specified interf ...

  • Intel SBCEGBESW10 CLI - page 420

    802.1x Commands 404 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide Interface Multiple Hosts Guest VLAN --------- -------------- ---------- 1 D isabled Enabled 2 E nabled Disabled Console# show dot1x advanced etherne t ext.1 Interface Multiple Hosts Guest VLAN --------- -------------- ---------- 1 D isabled Enable ...

  • Intel SBCEGBESW10 CLI - page 421

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 405 Appendix A: Getting Help Wo r l d W i d e W e b http://support.intel.com/support/m otherboards/server/blade.htm . T elephone All calls are billed US $25.00 pe r incident, levied in local curr ency at the applicable credit card exchange rate plus applicable ta xes ...

  • Intel SBCEGBESW10 CLI - page 422

    406 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide In Asia-P acific Region Australia .... 1800 649931 Cambodia .. 63 2 636 9797 (v ia Philippines) China ......... 800 820 1 100 (toll-free) ................... . 8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India ........... 0006517 2 68303634 (manual to ...

  • Intel SBCEGBESW10 CLI - page 423

    Intel® Blade Server Ethernet Switch Mo dules SBCEGBESW1 and SBCEGBESW10 CLI Guide 407 Colombia ... Contact A T&T USA at 01 800 91 1 0010. Once connected, dial 800 84 3 4481 Costa Rica . Contact A T&T USA at 0 800 0 1 14 1 14. Once connected, dial 800 843 4481 Ecuador (Andimate) .... Contact A T&T USA at 1 999 1 19. Once connected, dial ...

  • Intel SBCEGBESW10 CLI - page 424

    408 Intel® Blade Server Ethernet Switch Modul es SBCEGBESW1 and SBCEGBESW10 CLI Guide ...

Manufacturer Intel Category Switch

Documents that we receive from a manufacturer of a Intel SBCEGBESW10 CLI can be divided into several groups. They are, among others:
- Intel technical drawings
- SBCEGBESW10 CLI manuals
- Intel product data sheets
- information booklets
- or energy labels Intel SBCEGBESW10 CLI
All of them are important, but the most important information from the point of view of use of the device are in the user manual Intel SBCEGBESW10 CLI.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Intel SBCEGBESW10 CLI, service manual, brief instructions and user manuals Intel SBCEGBESW10 CLI. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Intel SBCEGBESW10 CLI.

Similar manuals

A complete manual for the device Intel SBCEGBESW10 CLI, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Intel SBCEGBESW10 CLI by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Intel SBCEGBESW10 CLI.

A complete Intel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Intel SBCEGBESW10 CLI - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Intel SBCEGBESW10 CLI, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Intel SBCEGBESW10 CLI, that we can find in the current document
3. Tips how to use the basic functions of the device Intel SBCEGBESW10 CLI - which should help us in our first steps of using Intel SBCEGBESW10 CLI
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Intel SBCEGBESW10 CLI
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Intel SBCEGBESW10 CLI in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Intel SBCEGBESW10 CLI?

Use the form below

If you did not solve your problem by using a manual Intel SBCEGBESW10 CLI, ask a question using the form below. If a user had a similar problem with Intel SBCEGBESW10 CLI it is likely that he will want to share the way to solve it.

Copy the text from the picture