  • Keating Of Chicago 2000 - page 1

    MIRACLEAN ® 2000 GAS GRIDDLE INST ALLA TION MANUAL USER OPERA TION and MAINTENANCE SER VICE INSTRUCIONS 1-800-KEA TING www .keatingofchicago.com “Serving Those Who Serve The Very Best” ® READ AND SA VE THIS MANUAL FOR FUTURE REFERENCE Record the Model No. and Serial No. of this Miraclean® Griddle in the space provided below . Serial No. Mode ...

  • Keating Of Chicago 2000 - page 2

    Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. W ARNING IF NOT INST ALLED, OPERA TED AND MAINT AINED IN ACCORDANCE WITH THE MANUF ACTURER'S INSTRUCTIONS, THIS ...

  • Keating Of Chicago 2000 - page 3

    INTRODUCTION Instructions in this manual should be read thoroughly before attempting to operate this Miraclean® Griddle. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel. Service information for Keating equipment has been prepared for use by qu ...

  • Keating Of Chicago 2000 - page 4

    GAS CONNECTIONS AND PIPE SIZE The Miraclean® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the Miraclean® Griddle manifold. Low gas pressure will cause slow recovery and/or delayed ignition. If you have a qu ...

  • Keating Of Chicago 2000 - page 5

    PLACING MIRACLEAN® GRIDDLE IN OPERA TION (When all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnect or piping from the building gas supply pipe. a. Gas pressure at manifold NA TURAL GAS – 4.0 in. W .C. b. Gas pressure at manifol ...

  • Keating Of Chicago 2000 - page 6

    4 becomes thicker . It becomes more of a meat cake than a hamburger . Therefore, the hamburger sp atula has a strong cutting edge. An egg spatula is shown in this illustration. An egg spatula has a long very thin blade so that it can be slipped under the egg without damaging it or breaking the yolk. This sp atula can also be used for chopping the s ...

  • Keating Of Chicago 2000 - page 7

    PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily , weekly , monthly and yearly intervals as necessary . Following preventive maintenance procedures will help keep your MIRACLEAN® Griddle working efficiently . Proper care and servicing will lead to years of quality performance. PREVENTIVE MAINTENANCE CLEANING CHART A VOID SERVI ...

  • Keating Of Chicago 2000 - page 8

    CLEANING CABINET The front, back and sides of the cabinet should be kept clean for sanitary reasons. CARE OF THE MIRACLEAN® SURF ACE The Miraclean® surface is very hard. With proper care, the MIRACLEAN® surface and its unique cooking properties will last for many years.  NEVER USE A GRIDDLE ST ONE, BRICK OR SCREEN TO CLEAN THE MIRACLEAN® SUR ...

  • Keating Of Chicago 2000 - page 9

    P ARTS LIST MIRACLEAN® Griddle ITEM DESCRIPTION P/N 1 CONTRON P ANEL FRAME 1-800-KEA TING 2 GREASE DRA WER 30" & 36" Deep 052505 3 SWITCH, ROCKER 035030 4 SP ARK IGNITER WITH ELECTRODE (NO BRACKET) 008327 5 CONTROL P ANEL INSERT 1-800-KEA TING 6 THERMOST A T 400°F 037088 THERMOST A T 550°F 023897 7 THERMOST A T KNOB 400°F 004163 T ...

  • Keating Of Chicago 2000 - page 10

    GAS V AL VE REGULA TOR ADJUSTMENT Recommended gas pressure at manifold (4.0" W .C. Natural gas 10.0" W .C. Prop ane gas) Adjustment of the gas valve pressure regulator is not normally necessary since it has been preset at the factory . During installation, the gas pressure should be checked at each gas valve with all burners operating. Ad ...

  • Keating Of Chicago 2000 - page 11

    9 MILLIVOL T CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONL Y ) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation. 2. The thermost at leads a ...

  • Keating Of Chicago 2000 - page 12

    B. THERMOPILE OUTPUT CHECK (“B” Reading. Thermost at contact s OPEN - Main burner OFF .) 1. Thermopile system - 325 millivolt s minimum. If the minimum millivolt reading is not obtainable, readjust thermopile for maximum millivolt output. If millivolt reading is still below minimum specified, replace thermopile. C. THERMOST A T RESIST ANCE CHEC ...

  • Keating Of Chicago 2000 - page 13

    11 Pilot on but no main a. ON/OFF switch is in “OFF” a. Put ON/OFF switch to “ON” position. burner ignition position. b. Gas valve is in “pilot” position. b. T urn knob to “ON” position. c. Thermost at is not turned on. c. T urn thermostat to desired temperature. d. Low gas pressure. d. Set manifold pressure to 4”. e. Gas valve fa ...

  • Keating Of Chicago 2000 - page 14

    L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp®, Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after Jun ...

  • Keating Of Chicago 2000 - page 15

    13 SER VICE INFORMA TION If you have a service related question call 1-800-KEA TING . Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEA TING OF CHICAGO, INC. Phone: (708) 544-6500 F AX: (708) 544-6505 T oll Free 1-800-KEA TING (In U.S. and C ...

Manufacturer Keating Of Chicago Category Griddle

Documents that we receive from a manufacturer of a Keating Of Chicago 2000 can be divided into several groups. They are, among others:
- Keating Of Chicago technical drawings
- 2000 manuals
- Keating Of Chicago product data sheets
- information booklets
- or energy labels Keating Of Chicago 2000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Keating Of Chicago 2000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Keating Of Chicago 2000, service manual, brief instructions and user manuals Keating Of Chicago 2000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Keating Of Chicago 2000.

A complete manual for the device Keating Of Chicago 2000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Keating Of Chicago 2000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Keating Of Chicago 2000.

A complete Keating Of Chicago manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Keating Of Chicago 2000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Keating Of Chicago 2000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Keating Of Chicago 2000, that we can find in the current document
3. Tips how to use the basic functions of the device Keating Of Chicago 2000 - which should help us in our first steps of using Keating Of Chicago 2000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Keating Of Chicago 2000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Keating Of Chicago 2000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Keating Of Chicago 2000?

Use the form below

If you did not solve your problem by using a manual Keating Of Chicago 2000, ask a question using the form below. If a user had a similar problem with Keating Of Chicago 2000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)