Manual Water Heater Innovations 196284-001

20 pages 0.24 mb
Download

Go to site of 20

Summary
  • Water Heater Innovations 196284-001 - page 1

    1 PRINTED IN U.S.A. 1004 PLACE THESE INSTRUCTIONS ADJACENT T O HEA TER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. COMMERCIAL GAS W A TER HEA TER Glass-Lined T ank-T ype W ater Heater P ART NO. 196284-001 • INST ALLA TION • OPERA TION • SERVICE • MAINTENANCE Thank you for buying this energy efficient water heater . We appreciate your con ...

  • Water Heater Innovations 196284-001 - page 2

    2 FOREWORD The design of models ***-75 and 100 comply with the latest version of ANSI Z21.10.3-CSA 4.3 as automatic storage or automatic circulating tank type water heaters. Installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping necessary . It is hig ...

  • Water Heater Innovations 196284-001 - page 3

    3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDER W A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERA TE HEA TER UNTIL ALL CO ...

  • Water Heater Innovations 196284-001 - page 4

    4 IF YOU EXPERIENCE AN OUT -OF-GAS SITUA TION, DO NOT TR Y T O RELIGHT APPLIANCES YOURSELF , ask your LP delivery person to relight pilots for you. Only trained LP professionals should conduct the required safety checks in accordance with industry standards. EXTENDED NON-USE PERIODS W ARNING HYDROGEN GAS CAN BE PRODUCED IN A HOT W A TER SYSTEM SERV ...

  • Water Heater Innovations 196284-001 - page 5

    5 Drain pans suitable for these heaters are available from your distributor or Apcom Inc., 125 Southwest Parkway , Franklin, TN 37065 or contact them by phone, 615-794-5574 or fax 615-791-0660. W ater heater life depends upon water quality , water pressure and the environment in which the water heater is installed. Water heat- ers are sometimes ins ...

  • Water Heater Innovations 196284-001 - page 6

    6 If the unconfined space is within a building of tight construction (buildings using the following construction: weather stripping, heavy insulation, caulking, vapor barrier , etc.), air for combustion, ventilation and draft hood dilution must be obtained from outdoors. The installation instructions for confined spaces in tightly constructed build ...

  • Water Heater Innovations 196284-001 - page 7

    7 VENT CONNECTION V ent connections must be made to an adequate stack or chimney . Size and install proper size vent pipe. Do not reduce pipe size to less than that of the draft hood outlet. Horizontal runs of vent pipe must have a minimum upward slope toward the chimney of 1/4 inch per foot. Dampers or other obstructions must not be installed in b ...

  • Water Heater Innovations 196284-001 - page 8

    8 Size the main gas line in accordance with T able 1. The figures shown are for straight lengths of pipe at 0.5 in. W .C. pressure drop, which is considered normal for low pressure systems. Note: Fittings such as elbows, tees and line regulators will add to the pipe pressure drop. Also refer to the latest version of the National Fuel Gas Code. TABL ...

  • Water Heater Innovations 196284-001 - page 9

    9 THERMOSTAT FOR NATURAL AND PROPANE GASES FIGURE 6. GAS PRESSURE REGULA TOR The gas pressure regulator is built into the gas valve and is equipped to operate on the gas specified on model and rating plate. The regulator is factory adjusted to deliver gas to burner at correct water column pressure allowing for a nominal pressure drop through the co ...

  • Water Heater Innovations 196284-001 - page 10

    10 FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH W A TER AND AIR PURGED A T F AUCETS . W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. 1. STOP! Read the safety information above on this label. 2. Set the the ...

  • Water Heater Innovations 196284-001 - page 11

    11 FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH W A TER AND AIR PURGED A T F AUCETS . W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. 1. STOP! Read the safety information above on this label. 2. Set the the ...

  • Water Heater Innovations 196284-001 - page 12

    12 TEMPERA TURE REGULA TION DANGER THIS W A TER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL W A TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AUTOMA TIC DISHWASHER AND LAUNDRY USE CAN CAUSE P AINFUL SCALDING WITH POSSIBLE SERIOUS AND PERMANENT INJURY . THE TEMPERA TURE A T WHICH INJUR Y OCCURS V ARIES WITH THE PERSON? ...

  • Water Heater Innovations 196284-001 - page 13

    13 • If the back draft cannot be corrected by the normal method or if a suitable draft cannot be obtained, a blower type flue gas exhauster must be employed to assure proper venting and correct combustion. HIGH TEMPERA TURE LIMIT SWITCH (Auto Reset T ype Energy Cut Off) TO RESET AUT OMA TIC GAS SHUTO FF This water heater is equipped with a automa ...

  • Water Heater Innovations 196284-001 - page 14

    14 T ABLE 3. INPUT CHECK TIME REQUIRED TO CONSUME 1 CU. FT . OF GAS Approx. Time Required T ype of BTU Per T o Consume 1 Cu. Ft. Model Gas Cu. Ft. of G as ***-75 Natural 1050 50.3 sec. Propane 2500 1 19.8 sec. ***-100 Natural 1050 50.3 sec. Propane 2500 1 19.8 sec. Use this formula to “clock” the meter . Be sure that other gas consuming applian ...

  • Water Heater Innovations 196284-001 - page 15

    15 PREVENTIVE MAINTENANCE RECOMMENDED PROCEDURE FOR PERIODIC REMOV AL OF LIME DEPOSITS FROM T ANK TYPE COMMERCIAL W A TER HEA TERS The amount of calcium carbonate (lime) released from water is in direct proportion to water temperature and usage, see chart. The higher the water temperature or water usage, the more lime deposits are dropped out of th ...

  • Water Heater Innovations 196284-001 - page 16

    16 Prepare the Water Heater T o delime the water heater using the Flo-Jug method, first prepare the heater for deliming. Then install the long plastic male adapter fitting into the drain valve opening of the water heater . Use teflon tape and hand tighten only . Do not overtighten. Prepare the Up-N-Down Transfer Kit The next step is the preparation ...

  • Water Heater Innovations 196284-001 - page 17

    17 PLUG THE TEMPERA TURE AND PRESSURE RELIEF V A L VE. Also, the leakage could be due to unusually high water pressures or temperatures in the system, or to a faulty relief valve. Y our dealer or a qualified service technician should be called to determine the cause of the problem and to correct it. 4. If you cannot identify or correct the source o ...

  • Water Heater Innovations 196284-001 - page 18

    18 NOTES ...

  • Water Heater Innovations 196284-001 - page 19

    19 NOTES ...

  • Water Heater Innovations 196284-001 - page 20

    20 ...

Manufacturer Water Heater Innovations Category Water Heater

Documents that we receive from a manufacturer of a Water Heater Innovations 196284-001 can be divided into several groups. They are, among others:
- Water Heater Innovations technical drawings
- 196284-001 manuals
- Water Heater Innovations product data sheets
- information booklets
- or energy labels Water Heater Innovations 196284-001
All of them are important, but the most important information from the point of view of use of the device are in the user manual Water Heater Innovations 196284-001.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Water Heater Innovations 196284-001, service manual, brief instructions and user manuals Water Heater Innovations 196284-001. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Water Heater Innovations 196284-001.

A complete manual for the device Water Heater Innovations 196284-001, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Water Heater Innovations 196284-001 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Water Heater Innovations 196284-001.

A complete Water Heater Innovations manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Water Heater Innovations 196284-001 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Water Heater Innovations 196284-001, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Water Heater Innovations 196284-001, that we can find in the current document
3. Tips how to use the basic functions of the device Water Heater Innovations 196284-001 - which should help us in our first steps of using Water Heater Innovations 196284-001
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Water Heater Innovations 196284-001
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Water Heater Innovations 196284-001 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Water Heater Innovations 196284-001?

Use the form below

If you did not solve your problem by using a manual Water Heater Innovations 196284-001, ask a question using the form below. If a user had a similar problem with Water Heater Innovations 196284-001 it is likely that he will want to share the way to solve it.

Copy the text from the picture