Manual Bosch Appliances DS7400XIV4-EXP

40 pages 0.75 mb
Download

Go to site of 40

Summary
  • Bosch Appliances DS7400XIV4-EXP - page 1

    EN User Guide Security System DS7400XiV4-EXP ...

  • Bosch Appliances DS7400XIV4-EXP - page 2

    DS7400XiV4-EXP | User Guide | 1.0 System Overview EN | 2 Bosch Security Systems | 6/05 | 4998154961B Contents 1.0 System Ov erview...................................................... 3 2.0 Conventions Used in This Guide .......................... 3 2.1 Tips, Notes, Cautio ns, and Warnings ....................... 3 2.2 Typographical Co nventions.. ...

  • Bosch Appliances DS7400XIV4-EXP - page 3

    DS7400XiV4-EXP | User Guide | 1.0 System Overview EN | 3 Bosch Security Systems | 6/05 | 4998154961B 1 .0 Syst em Overview A security system usually consists of: • A Control Panel : The control panel is the center of your intrusion/fire alarm system. It supports vital functions such as receiving trouble and alarm signals from detectors, sounding ...

  • Bosch Appliances DS7400XIV4-EXP - page 4

    DS7400XiV4-EXP | User Guide | 3.0 Understanding Areas (Partitions) EN | 4 Bosch Security Systems | 6/05 | 4998154961B 3.0 Underst anding Areas ( Part it ions ) Your alarm system might be partitioned. A partitioned system is a system that is divided into two to eight areas that you can arm and disarm independently. Each keypad and keyfob can be assi ...

  • Bosch Appliances DS7400XIV4-EXP - page 5

    DS7400XiV4-EXP | User Guide | 4.0 Understanding the Text and LED Keypads EN | 5 Bosch Security Systems | 6/05 | 4998154961B 4.0 Underst anding t he T ext and LE D K eypads DS7447E/DS7447V2 are alpha-numeric LCD keypads. DS7445i/DS7445V2 are LED keypads; its LEDs (1 to 16) represent the first 16 zones of the system. Both display information about co ...

  • Bosch Appliances DS7400XIV4-EXP - page 6

    DS7400XiV4-EXP | User Guide | 5.0 Understanding the RF Keypad and Keyfobs EN | 6 Bosch Security Systems | 6/05 | 4998154961B 5.0 Underst anding t he R F Keypad and K ey fobs Figure 2: RF Keypad and Keyfobs RF3341 RF3332/ RF3332E RF3334/ RF3334E 1 2 3 4 5 6 7 8 9 0 # 5.1 General Information Your security system might use keypads or keyfobs that use ...

  • Bosch Appliances DS7400XIV4-EXP - page 7

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 7 Bosch Security Systems | 6/05 | 4998154961B 6.0 Day t o Day Operat ions 6.1 Standard Operations This section describes the standard (those built and programmed into your system at the factory) procedures for arming and disarming your security system. Your installing company can program ...

  • Bosch Appliances DS7400XIV4-EXP - page 8

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 8 Bosch Security Systems | 6/05 | 4998154961B 6.1.2 Perimeter Instant Arming Use perimeter instant arming to arm only the exterior (perimeter) zones when you remain in the building. An exit delay is in effect, but no entry delay is in effect so an alarm does occur upon entry. The green St ...

  • Bosch Appliances DS7400XIV4-EXP - page 9

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 9 Bosch Security Systems | 6/05 | 4998154961B 6.1.3 Perimeter Arming Perimeter arming is used when someone is still in the building, only the exterior (perimeter) zones must be armed, and an entry/exit delay is in effect. The green Status LED must be lit and, if using a text keypad, “Re ...

  • Bosch Appliances DS7400XIV4-EXP - page 10

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 10 Bosch Security Systems | 6/05 | 4998154961B 6.1.4 Custom Arming Custom arming is used to arm zones that you specify and your installer programs into your system. An entry/exit delay is in effect unless otherwise programmed. The green Status LED must be lit and, if using a text keypad, ...

  • Bosch Appliances DS7400XIV4-EXP - page 11

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 11 Bosch Security Systems | 6/05 | 4998154961B 6.1.5 Maximum Security Arming Maximum security arming is used when no one is still in the building, all zones are to be armed, an exit delay is in effect, but no entry delay is in effect so an alarm does occur upon entry. The green Status LED ...

  • Bosch Appliances DS7400XIV4-EXP - page 12

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 12 Bosch Security Systems | 6/05 | 4998154961B 6.1.6 Normal Disarming Please read Section 7.0 Emergency Procedures on page 19 before you are confronted with an emergency event. If you entered the building through a perimeter door, you might hear a steady entry alert tone from the wired ke ...

  • Bosch Appliances DS7400XIV4-EXP - page 13

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 13 Bosch Security Systems | 6/05 | 4998154961B 6.2 Optional Operations 6.2.1 Quick Arming Quick arming allows you to enter some arming commands without first entering a PIN. If quick arming is not used, you must enter a PIN at the beginning of all arming command sequences. Quick arming is ...

  • Bosch Appliances DS7400XIV4-EXP - page 14

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 14 Bosch Security Systems | 6/05 | 4998154961B 6.2.3 Zone Bypass There might be occasions when you need to temporarily bypass one or more zones before arming the system. Bypass commands only work when the control panel is disarmed. For example, an open window can cause the text keypad to ...

  • Bosch Appliances DS7400XIV4-EXP - page 15

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 15 Bosch Security Systems | 6/05 | 4998154961B 6.2.4 Automatic Arming You can program each area to arm automatically once per day. You cannot program automatic arming from an RF (wireless) keypad. Programming automatic arming in Master Keypad mode affects all areas you have access to. If ...

  • Bosch Appliances DS7400XIV4-EXP - page 16

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 16 Bosch Security Systems | 6/05 | 4998154961B 6.2.6 Automatic Disarming You can program each area to disarm automatically once per day. You cannot program automatic disarming from an RF (wireless) keypad. If your program automatic disarming in Master Keypad mode, it affects all areas you ...

  • Bosch Appliances DS7400XIV4-EXP - page 17

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 17 Bosch Security Systems | 6/05 | 4998154961B 6.2.8 Chime Mode Chime Mode causes the keypad sounders to beep each time a Perimeter or Entry/Exit zone is triggered when the control panel is off (disarmed). The [#][7] command is used to turn Chime Mode both off and on. Table 16: Chime Mode ...

  • Bosch Appliances DS7400XIV4-EXP - page 18

    DS7400XiV4-EXP | User Guide | 6.0 Day to Day Operations EN | 18 Bosch Security Systems | 6/05 | 4998154961B 6.2.10 Changing the Date Because you can change the system date only in Master Programming Mode, you cannot program the system date from an RF (wireless) keypad. Record your entries so they are available before you enter Master Programming Mo ...

  • Bosch Appliances DS7400XIV4-EXP - page 19

    DS7400XiV4-EXP | User Guide | 7.0 Emergency Procedures EN | 19 Bosch Security Systems | 6/05 | 4998154961B 7 .0 Emergency Procedures 7.1 Identifying Alarm Sounds Your alarm system might be programmed for a steady alarm sound or a pulsed alarm sound. It is important to learn the difference between a fire alarm sound and an intrusion alarm sound befo ...

  • Bosch Appliances DS7400XIV4-EXP - page 20

    DS7400XiV4-EXP | User Guide | 7.0 Emergency Procedures EN | 20 Bosch Security Systems | 6/05 | 4998154961B To silence the fire trouble tone, enter any [PIN] and press the [Off] key (or enter [PIN ][ #] from an RF3341 Keypad). After the problems are resolved, enter a [PIN] and press the [Off] key ([PIN ][ #] from an RF3341 Keypad) to clear the “Fi ...

  • Bosch Appliances DS7400XIV4-EXP - page 21

    DS7400XiV4-EXP | User Guide | 7.0 Emergency Procedures EN | 21 Bosch Security Systems | 6/05 | 4998154961B Installation Considerations Proper location of detection devices is one of the most critical factors in a fire alarm system. Here are some general considerations: • Do not install smoke detectors in “dead air” spaces or close to ventilat ...

  • Bosch Appliances DS7400XIV4-EXP - page 22

    DS7400XiV4-EXP | User Guide | 7.0 Emergency Procedures EN | 22 Bosch Security Systems | 6/05 | 4998154961B 7.10 Turning OFF (Disarming) Your System under Duress A Duress PIN (refer to Section 8.0 Personal Identification Numbers (PINs) on page 23 and Section 8.4 PIN Authority Levels on page 24) is used when someone demands, by threatening your life ...

  • Bosch Appliances DS7400XIV4-EXP - page 23

    DS7400XiV4-EXP | User Guide | 8.0 Personal Identification Numbers (PINs) EN | 23 Bosch Security Systems | 6/05 | 4998154961B 8.0 P ersonal Ident ificat ion Numbers ( PI Ns) 8.1 General Information When programming personal identification numbers, it is helpful to know these terms: • PIN: Personal Identification Number. Users enter this four- or s ...

  • Bosch Appliances DS7400XIV4-EXP - page 24

    DS7400XiV4-EXP | User Guide | 8.0 Personal Identification Numbers (PINs) EN | 24 Bosch Security Systems | 6/05 | 4998154961B 8.4 PIN Authority Levels 0 = Master Can enter all commands, add or change PINs in assigned areas, change the time and date, bypass, arm, disarm, perform system tests, system reset, and view history. User Number 001 must have ...

  • Bosch Appliances DS7400XIV4-EXP - page 25

    DS7400XiV4-EXP | User Guide | 9.0 Error Displays EN | 25 Bosch Security Systems | 6/05 | 4998154961B 9.0 Error Displays You can read e rror displays only when the control panel is disarmed. Some control panel errors, such as battery trouble and any RF troubles, cause the keypad sounders to beep every 10 seconds. You can silence the keypad sounders ...

  • Bosch Appliances DS7400XIV4-EXP - page 26

    DS7400XiV4-EXP | User Guide | 9.0 Error Displays EN | 26 Bosch Security Systems | 6/05 | 4998154961B 9.1 System Faults System faults are designated as shown in Table 24 : Table 24: System Faults [#][8][7] displays: [#][8][9] displays: RAM Fault System Fault 01 ROM Fault System Fault 02 EEPROM Fault System Fault 03 Ground Fault System Fault 04 2Ph/B ...

  • Bosch Appliances DS7400XIV4-EXP - page 27

    DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 27 Bosch Security Systems | 6/05 | 4998154961B 1 0.0 T est ing Y our Syst em 10.1 Zone Test The zone test confirms that detectors report alarms to the keypad. A zone test works on all zones, except 24-hour zones and fire zones. While the keypad is in a zone test, no control panel alarms ac ...

  • Bosch Appliances DS7400XIV4-EXP - page 28

    DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 28 Bosch Security Systems | 6/05 | 4998154961B 10.2 Battery Tests If a power failure occurs, your control panel has a backup battery that continues to power the control panel for many hours. The control panel automatically recharges the battery when power is restored. In addition to the au ...

  • Bosch Appliances DS7400XIV4-EXP - page 29

    DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 29 Bosch Security Systems | 6/05 | 4998154961B 10.4 Fire Walk Test This test confirms that smoke detectors report alarms to the keypads. The Fire Walk Test tests all fire zones, including verified fire and waterflow. This test requires you to manually alarm each zone. If programmed, a Fire ...

  • Bosch Appliances DS7400XIV4-EXP - page 30

    DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 30 Bosch Security Systems | 6/05 | 4998154961B 10.5 Event History Readback The History Buffer stores the last 400 events in memory. The text keypad can display all of these events. The LED keypad only displays the zones (1 to 16) that alarmed since the last Event History Readback. If you p ...

  • Bosch Appliances DS7400XIV4-EXP - page 31

    DS7400XiV4-EXP | User Guide | 11.0 The Master Keypad (Text Keypad Only) EN | 31 Bosch Security Systems | 6/05 | 4998154961B 1 1 .0 T he Mast er Ke ypad (T ext K eypad Only ) 11.1 General Information Your system can include a Master Keypad. A Master Keypad is a text keypad programmed to provide access to all areas assigned to you, not just the area ...

  • Bosch Appliances DS7400XIV4-EXP - page 32

    DS7400XiV4-EXP | User Guide | 11.0 The Master Keypad (Text Keypad Only) EN | 32 Bosch Security Systems | 6/05 | 4998154961B 11.3 Single Partition Mode Single Partition Mode controls areas on a one by one basis from the Master Keypad. To enter Single Partition Mode, enter your [PIN], then press the [#] key twice. This displays the first area to whic ...

  • Bosch Appliances DS7400XIV4-EXP - page 33

    DS7400XiV4-EXP | User Guide | 11.0 The Master Keypad (Text Keypad Only) EN | 33 Bosch Security Systems | 6/05 | 4998154961B 11.5 Disarming from the Master Keypad Table 32: Disarming from the Master Keypad Type of Disarming Desired Command Sequence Disarming all the areas to which you have access. [PIN][Off] This disarms all the areas to which you h ...

  • Bosch Appliances DS7400XIV4-EXP - page 34

    DS7400XiV4-EXP | User Guide | 12.0 Glossary EN | 34 Bosch Security Systems | 6/05 | 4998154961B 1 2.0 Glossary Access Control PIN An Access Control PIN is a special code to turn electric door locks or other mechanisms connected to the control panel on or off. Area (Partition) An area exists when the system is divided up into 2, 3, 4, 5, 6, 7, or 8 ...

  • Bosch Appliances DS7400XIV4-EXP - page 35

    DS7400XiV4-EXP | User Guide | 13.0 Quick Reference Guide EN | 35 Bosch Security Systems | 6/05 | 4998154961B 1 3.0 Quick Reference Guide Test the system weekly to ensure it is functioning properly. If problems are detected in testing or changes are noticed in normal operation, call your installing company for service. The manufacturer recommends re ...

  • Bosch Appliances DS7400XIV4-EXP - page 36

    DS7400XiV4-EXP | User Guide | 13.0 Quick Reference Guide EN | 36 Bosch Security Systems | 6/05 | 4998154961B Zone Protected Area Zone Protected Area Zone Protected Area Zone Protected Area 129 159 189 219 130 160 190 220 131 161 191 221 132 162 192 222 133 163 193 223 134 164 194 224 135 165 195 225 136 166 196 226 137 167 197 227 138 168 198 228 1 ...

  • Bosch Appliances DS7400XIV4-EXP - page 37

    DS7400XiV4-EXP | User Guide | 14.0 System Features Reference Guide EN | 37 Bosch Security Systems | 6/05 | 4998154961B 1 4.0 Syst em F eat ures Reference Guide Audible Alarm Signaling Device Sounds Intrusion ( ) Pulse ( ) Continuous Fire ( ) Pulse ( ) Continuous Keypad Supplemental Alarm [B] Key ( ) Continuous ( ) Silent This system has the Duress ...

  • Bosch Appliances DS7400XIV4-EXP - page 38

    DS7400XiV4-EXP | User Guide | Notes EN | 38 Bosch Security Systems | 6/05 | 4998154961B Notes ...

  • Bosch Appliances DS7400XIV4-EXP - page 39

    DS7400XiV4-EXP | User Guide | Notes EN | 39 Bosch Security Systems | 6/05 | 4998154961B Notes ...

  • Bosch Appliances DS7400XIV4-EXP - page 40

    © 2005 Bosch Security Systems 4998154961B Bosch Security Systems www.boschsecuritysystems.com ...

Manufacturer Bosch Appliances Category Home Security System

Documents that we receive from a manufacturer of a Bosch Appliances DS7400XIV4-EXP can be divided into several groups. They are, among others:
- Bosch Appliances technical drawings
- DS7400XIV4-EXP manuals
- Bosch Appliances product data sheets
- information booklets
- or energy labels Bosch Appliances DS7400XIV4-EXP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bosch Appliances DS7400XIV4-EXP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bosch Appliances DS7400XIV4-EXP, service manual, brief instructions and user manuals Bosch Appliances DS7400XIV4-EXP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bosch Appliances DS7400XIV4-EXP.

A complete manual for the device Bosch Appliances DS7400XIV4-EXP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bosch Appliances DS7400XIV4-EXP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bosch Appliances DS7400XIV4-EXP.

A complete Bosch Appliances manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bosch Appliances DS7400XIV4-EXP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bosch Appliances DS7400XIV4-EXP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bosch Appliances DS7400XIV4-EXP, that we can find in the current document
3. Tips how to use the basic functions of the device Bosch Appliances DS7400XIV4-EXP - which should help us in our first steps of using Bosch Appliances DS7400XIV4-EXP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bosch Appliances DS7400XIV4-EXP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bosch Appliances DS7400XIV4-EXP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bosch Appliances DS7400XIV4-EXP?

Use the form below

If you did not solve your problem by using a manual Bosch Appliances DS7400XIV4-EXP, ask a question using the form below. If a user had a similar problem with Bosch Appliances DS7400XIV4-EXP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)