  • Trane GAT2A0C60S51SA - page 1

    Modular Multi-position Air Handler s GA T2A0B42S31SA GA T2A0C48S41SA GA T2A0C60S51SA PUB. NO . 22-1857-03 ...

  • Trane GAT2A0C60S51SA - page 2

    2 Pub . No. 22-1857-03 Featur es and Benefits © 2012 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.2 Insulating V alue (A vg. Insulating V alue R-8.2) - Composite F oamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cl ...

  • Trane GAT2A0C60S51SA - page 3

    Pub . No . 22-1857-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 GA T2A0B42S31SA 6 GA T2A0C48S41SA 6 GA T2A0C60S51SA 6 P erformance Data 7 Electrical Data 10 Wiring Diagrams 13 Field Wiring 15 Con ver tibility 17 Dimensions 18 ...

  • Trane GAT2A0C60S51SA - page 4

    4 Pub . No. 22-1857-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEAA C05BK1A Electric Heater , 5kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C05LG1A Electric Heater , 5kW , Lugs, 24V Control, 1 Ph A to C BA YEAA C08BK1A Electric Heater , 8kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C08LG1A Electric Heater , 8kW , ...

  • Trane GAT2A0C60S51SA - page 5

    Pub . No . 22-1857-03 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connections e Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s w Compact 20.8” Depth with Doors Remo ved 1 Unique Cabinet Design 2 Precision Durable Door Seals 0 Thermal Expansion V alve (TXV) 3 Refrigeration Connections 8 All Aluminum Coil r Safety Door ...

  • Trane GAT2A0C60S51SA - page 6

    6 Pub . No. 22-1857-03 General Data 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI ST ANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for perf ormance data. 2 3/4" Male Plastic Pipe (Ref .: ASTM 1785-76) 3 Constant torque Motor PRODUCT SPECIFICA TIONS MODEL R ...

  • Trane GAT2A0C60S51SA - page 7

    Pub . No . 22-1857-03 7 General Data AIRFLO W PERFORMANCE GA T2A0B42S31SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.2 1546 1421 1313 1449 1260 1120 0.3 1488 1380 1280 1401 1233 1099 0.4 1425 1329 1233 1348 119 ...

  • Trane GAT2A0C60S51SA - page 8

    8 Pub . No. 22-1857-03 Per for mance Data GA T2A0C48 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C48S41SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1904 1711 1541 1652 1455 1305 0.1 1881 1687 1529 1640 1450 1288 0.2 1844 1666 1511 1619 1425 1271 0.3 1806 1637 148 ...

  • Trane GAT2A0C60S51SA - page 9

    Pub . No . 22-1857-03 9 Per for mance Data GA T2A0C60 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C60S51SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 5 4 † 3 2 1 5 4 † 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582 0. ...

  • Trane GAT2A0C60S51SA - page 10

    10 Pub . No . 22-1857-03 Per for mance Data WIRING D A T A GA T2A0B42S31SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.7** 3 15 - - 2 ...

  • Trane GAT2A0C60S51SA - page 11

    Pub . No . 22-1857-03 11 Per for mance Data WIRING D A T A GA T2A0C48S41SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 3.1** 4 15 - - 3 ...

  • Trane GAT2A0C60S51SA - page 12

    12 Pub . No . 22-1857-03 Per for mance Data DIST ANCE FROM BELL Y B AND T O SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel is centered in Blower Housing MODEL DIM "A" GA T2A0B42S31SA 3 GA T2A0C48S41SA 2-13/16 GA T2A0C60S51SA 2-1/4 WIRING D A T A GA T2A0C60S51SA H ...

  • Trane GAT2A0C60S51SA - page 13

    WIRING DIA GRAM FOR GA T2A0B42 AND GA T2A0C48 AIR HANDLERS ...

  • Trane GAT2A0C60S51SA - page 14

    WIRING DIA GRAM FOR GA T2A0C60 AIR HANDLERS ...

  • Trane GAT2A0C60S51SA - page 15

    Pub . No . 22-1857-03 15 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED COOLING • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. Air Handler Hook-up Diagra m Cooling Red Y ellow Green White Blue Y ellow Green White Blue B B - Blue Blue W G Y Y - Y ellow Y ellow R Red O Oran ...

  • Trane GAT2A0C60S51SA - page 16

    16 Pub . No . 22-1857-03 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat Air Handler Hook-up Diagra m HP Red Y ellow Green White Blue Orange Y ellow Green White Blue B B - Blue R - Red W G Y Y - Y ellow R Red O Orang ...

  • Trane GAT2A0C60S51SA - page 17

    Pub . No . 22-1857-03 17 GA T2 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Horizontal Left* V er tical Upflow* (as shipped) Horizontal Right* Horizontal Left Condensate Drains Refrigerant Connections Horizontal Right Condensate Drains Refrigerant Connections * Note: No internal ...

  • Trane GAT2A0C60S51SA - page 18

    18 Pub . No . 22-1857-03 Dimensions GA T2 AIR HANDLER DIMENSIONAL D A T A D H W Model No . H W D GA T2A0B42 55.7 21.3 21.75 GA T2A0C48 56.9 23.5 21.75 GA T2A0C60 61.7 23.5 21.75 GA T2 AIR HANDLERS ARE ALL TWO PIECE CABINETS. ...

  • Trane GAT2A0C60S51SA - page 19

    Pub . No . 22-1857-03 19 GA T2 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE GA T2A0B42 55.7 45.5 18.4 21.3 18.4 9.2 24.8 TXV 7/8 GA T2A0C48 56.9 46.7 20.5 23.5 20.5 10.3 24.2 TXV 7/8 GA T2A0C60 61.7 51.5 20.5 23.5 20.5 10.3 27.0 TXV 7/8 ...

  • Trane GAT2A0C60S51SA - page 20

    T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 03/12 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. ...

Manufacturer Trane Category Air Conditioner

Documents that we receive from a manufacturer of a Trane GAT2A0C60S51SA can be divided into several groups. They are, among others:
- Trane technical drawings
- GAT2A0C60S51SA manuals
- Trane product data sheets
- information booklets
- or energy labels Trane GAT2A0C60S51SA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Trane GAT2A0C60S51SA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Trane GAT2A0C60S51SA, service manual, brief instructions and user manuals Trane GAT2A0C60S51SA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Trane GAT2A0C60S51SA.

Similar manuals

A complete manual for the device Trane GAT2A0C60S51SA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Trane GAT2A0C60S51SA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Trane GAT2A0C60S51SA.

A complete Trane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Trane GAT2A0C60S51SA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Trane GAT2A0C60S51SA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Trane GAT2A0C60S51SA, that we can find in the current document
3. Tips how to use the basic functions of the device Trane GAT2A0C60S51SA - which should help us in our first steps of using Trane GAT2A0C60S51SA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Trane GAT2A0C60S51SA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Trane GAT2A0C60S51SA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Trane GAT2A0C60S51SA?

Use the form below

If you did not solve your problem by using a manual Trane GAT2A0C60S51SA, ask a question using the form below. If a user had a similar problem with Trane GAT2A0C60S51SA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)