Manual NuTone VX1000C

40 pages Not applicable
Download

Go to site of 40

Summary
  • NuTone VX1000C - page 1

    B UIL T -IN CENTRAL CLEANING SYSTEM INST ALLA TION INSTR UCTIONS F or P ower Unit Models VX475, VX550, VX1000, VX475C , VX550C , and VX1000C Broan-NuT one LLC Har tf ord, Wisconsin www .nutone .com 888-336-3948 T o register this product, visit www .nutone .com P ar t No . 30042322 rev . 08 ...

  • NuTone VX1000C - page 2

    T ABLE OF CONTENTS SYSTEM PLANNING AND LA Y OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • NuTone VX1000C - page 3

    THE RANCH STYLE HOUSE Here the power unit is mounted in the garage. The intake and e xhaust tubing, the only e xposed tubing in the installation, runs up the garage wall and into the attic. The trunk line runs horizontally through the attic from the power unit to the f ar thest inlet location. Branch lines spread throughout the attic, connecting th ...

  • NuTone VX1000C - page 4

    THE SPLIT -LEVEL HOUSE Like the tw o-stor y house , the split le vel installation commonly calls f or a two-le v el trunk line. Here, the power unit is located in the garage. The intake tubing runs e xposed up the garage wall and into the g round le vel section's attic. T wo branch lines connect this par t of the trunk line to inlet lines whic ...

  • NuTone VX1000C - page 5

    5 W ORKING WITH PLASTIC TUBING Cutting the T ubing Bef ore you cut a length of tube , accurately measure the length you need. Allow 5/8” of tubing for inserting into fittings and 1 ½” f or placing into fle xible tubing. Cut the plastic tubing with a hacksa w , making sure that the cut is e xactly square. (Y ou can use a tube cutter if one is a ...

  • NuTone VX1000C - page 6

    6 Making a Joint Inser t the tube into the fitting, aligning the two parts as they will be installed. Mar k the tube and the fitting so that y ou can quickly realign the joint. See Figure 7. Apply cement only to the outside of the tube. Dab the cement generously in an inch-wide band. Inser t the tube into the fitting with the alignment marks a quar ...

  • NuTone VX1000C - page 7

    7 MODEL CF361 & CF361F (For Use with CI370 and 360 Inlets) 3. Ref er to Figure 10. Nail brack et to the side of the stud so that the front edge of the brac ket is flush to the front of the stud. (The brack et ma y also be nailed to the front edge of the stud. See face mounting illustrated. F or f ace mounting, use locating tabs on brac ket f or ...

  • NuTone VX1000C - page 8

    INST ALLING THE TUBING Use the f ollowing installation guidelines when installing tubing. 1. Start tubing installation at far thest inlet and work tow ard the power unit. 2. T ubing r un to the po wer unit should be as straight as possible . 3. When assembling sections with elbo ws and tees, mak e sure the cur v e in the fitting is aligned so that ...

  • NuTone VX1000C - page 9

    9 W ALL INLET INST ALLA TION Model CI370 W all Inlet (CF361 and CF361F Rough-In) 1. Remove the cardboard plaster guard. 2. Ref er to Figure 20. For some drywall or panel construction, the plaster frame will extend be y ond the finished wall. In this case, remo ve plaster fr ame from mounting brac ket b y removing mounting scre ws. NO TE : When usin ...

  • NuTone VX1000C - page 10

    10 CI390 & CI395 ELECTRA V AL VE ™ ELECTRIFIED INLET INST ALLA TION (CI395RK R OUGH-IN) 1. See Figure 27. F asten the mounting plate to a stud within three studs (48") of an electrical outlet box. Measure and mark the wire 10" from the plug (A). F eed the wire through the top hole in the mounting plate (just abov e the circular open ...

  • NuTone VX1000C - page 11

    11 SAFETY INSTR UCTIONS FOR HOUSEHOLD USE ONL Y . INST ALL ONL Y ON A NOMINAL 120 V , 60 Hz, 7 A SUPPL Y PRO TECTED BY A MAXIMUM 15 A O VERCURRENT PRO TECTIVE DEVICE. THE PIN CONNECT OR ON THIS TYPE A W ALL V AL VE IS INTENDED FOR USE ON A NOMINAL 120 V , 60 Hz, 7 A SUPPL Y ONL Y . IT IS REQUIRED T O BE WIRED BY A QU ALIFIED ELECTRICIAN AND IS REQU ...

  • NuTone VX1000C - page 12

    LOCA TING A CCESS KEYS IN EXISTING CONSTR UCTION Unless your home is a r anch-style house where a single trunk line can r un directly through the attic or basement, y ou should first inv estigate y our house to find the ke y to running your tubing from le vel to le vel. Look f or an accessible area free from obstructions that will accommodate the 2 ...

  • NuTone VX1000C - page 13

    INST ALLING THE INLET TUBING When your planning is complete , you will ha v e to determine where all the inlets and the power unit will be located. Y ou hav e also mapped out the location of y our trunk line and f ound the access you need to run vertical tubing from one le vel of y our house to another le v el. Y ou should have acquainted yourself ...

  • NuTone VX1000C - page 14

    Drilling the Access Holes Once you are certain that you’ve located the center of the wall directly abo ve the inlet location, use a 2½” hole saw to cut the access hole through the wall plate or header and into the wall ca vity . (A 1/2” drill is recommended.) Carefully remov e the drill from the hole. Now , use a flashlight to inspect the wa ...

  • NuTone VX1000C - page 15

    Whate ver the case , inser t the completed inlet line into the access hole and thread it down inside the w all. The inlet line should be long enough so that it e xtends abov e the joists in the attic; at this height, it can be easily connected to the branch and truck lines . When cutting the inlet tubing to length, remember that your inlet will be ...

  • NuTone VX1000C - page 16

    Use an awl or icepic k to punch pilot holes where you mark ed the two hole locations. Now , dr ill tw o 3⁄8” diameter holes, using the pilot holes as the centers. Locate and drill these holes e xactly as marked with the template. Also drill four pilot holes in the f our corners of the marked area. Make sure these holes are located inside the ma ...

  • NuTone VX1000C - page 17

    Hold the assembly in place f or a fe w minutes as the cement sets; allow 5 minutes f or the cement to completely dr y . Now , strip the ends of the two low v oltage wires, and then connect the wires to the screw terminals on the back of the inlet cov er . Mak e sure the wires are tightly secured under the terminal screws. When the wiring is complet ...

  • NuTone VX1000C - page 18

    Inser t the bottom scre w into the inlet cov er and through the other par ts . Give the screw a few tu rn s un til it f ir mly engages in the mounting plate. Now , le vel and slightly lo wer the assembly . Make sure the wall is sandwiched between the inner and outer par ts—y ou’ll be able to f eel if mounting plate is firmly centered on the ins ...

  • NuTone VX1000C - page 19

    5. Attach the lo w v oltage wires to terminal screws on back of wall inlet (Figure 35). If using 361 Rough-in with CI370 Series Inlets, ref er to instructions on page 7, step 3, shown in Figure 10. 6. Inser t w all inlet into brack et and secure with the two screws pro vided (Figure 36). MODEL 330 & CI335 SERIES W ALL INLET INST ALLA TION CF329 ...

  • NuTone VX1000C - page 20

    FLOOR INLET INST ALLA TION IN NEW & EXISTING CONSTR UCTION Model CI370 or 360 Series Inlets (361 Rough-In) 1. Ref er to Figures 41 and 42. After floor inlet location has been selected, cut a 3 1 ⁄ 16 " x 2 9 ⁄ 16 " square hole in floor . Center line of inlet must be located at least 2½" from wall to allow co ver to be opened ...

  • NuTone VX1000C - page 21

    21 ORIGINAL V A CP AN ™ INST ALLA TION INSTR UCTIONS NO TE: Please read instr uctions prior to installation. INST ALLA TION TIPS • Plan the location of your ORIGINAL V ACP AN to be conv eniently located f or s weeping clean-ups . • Also consider ease of access of vacuum tube piping connections during installation. • The leading edge of the ...

  • NuTone VX1000C - page 22

    IN W ALL INST ALLA TIONS Ref er to Figure 47. • ORIGINAL V ACP AN can be installed between wall studs in side walls . • ORIGINAL V ACP AN should be located tight to one side in stud space. • Once the ORIGINAL V ACP AN location is determined, cut a 6¾” long x 1¾” high slot in the wall and baseboard to accept the ORIGINAL V ACP AN. • Th ...

  • NuTone VX1000C - page 23

    23 ORIGINAL V A CUSWEEP ® INLET V AL VE INST ALLA TION INSTR UCTIONS CONNECTION FR OM B ELO W Ref er to Figure 48. 1. T ur n the po wer to the v acuum unit OFF . Measure distance (X) between the kic kplate f ace and the inside edge of the cabinet. Then, add 2¾” to the measured distance. See Figure 48-1. Measure out the new distance (X+2¾”) f ...

  • NuTone VX1000C - page 24

    24 CONNECTION FR OM BEHIND Ref er to Figure 49. 1. T ur n the po wer to the v acuum unit OFF . Choose a location under the cabinet f or the V acuSweep ® Inlet V alve so that it can be connected to the centr al vacuum pipe. Measure distance (X) between the kic kplate f ace and the inside edge of the cabinet. Then add 2¾” to the measured distance ...

  • NuTone VX1000C - page 25

    25 wire/string to temporarily hold the pipe and elbow in place, insert the V acuSweep ® Inlet V alv e into the opening at the base of the wall and elbo w . DO NO T glue this connection (Designed f or friction fit). See Figure 50-5. 6. Remov e the wire/string. With the door in an open position, secure the V acuSweep ® Inlet V alv e to the wall usi ...

  • NuTone VX1000C - page 26

    Once you ha v e installed all your inlets , y ou can complete the network of tubing that connects your inlets to the power unit. This network consists of the f ollowing parts: 90° Elbows – Used for connecting the inlet lines to the branch lines. Also used f or making smooth 90° turns in branch lines or tr unk lines . 45° Elbows – Used f or a ...

  • NuTone VX1000C - page 27

    Joining Straight Lengths of T ubing Both branch lines and the trunk lines may require lengths of tubing longer than those 8´ sections supplied. Use stop couplings to join two straight lengths of tubing. Inser t one end of the tubing into the stop coupling; join the second length of tubing into the other end of the stop coupling. Stop couplings are ...

  • NuTone VX1000C - page 28

    Circumventing an Obstac le Where ver possib le the branch lines should connect to the trunk line in straight paths. The f e wer turns in a tubing system, the more efficient air flow . Accordingly , you should locate the inlets to av oid zig-zags in the branch lines . But, sometimes, when y ou just can’t av oid an obstacle, you are required to con ...

  • NuTone VX1000C - page 29

    Connecting the Low V oltage Wiring Ideally , you will run the wiring and make all the wiring connections after you ha v e completed the tubing system. Of course, the inlet wiring must be run at the time the inlet tubing is threaded through the walls . Run the low v oltage wiring along the trunk line; at appro ximately 12˝-18˝ inter v als , use el ...

  • NuTone VX1000C - page 30

    Attach the tubing to the joists or ceiling with either perf orated metal or suppor t str apping (suppor t strapping is av ailab le from NuT one). Make all br anch line connections in the same wa y y ou would an attic installation. Make sure that all branch lines enter the trunk line at an angle that is at least lev elled with the trunk line. Make s ...

  • NuTone VX1000C - page 31

    Ref er to page 4 f or information on locating the power unit. MOUNTING This section ref ers to Figures 51 and 52. Y our power unit mounts to the wall using a mounting system. The wall mounting brac k et, provided with y our power unit, mounts to the wall. It has 4 fingers at the top and 4 others at the bottom. The pow er unit has 4 upper openings a ...

  • NuTone VX1000C - page 32

    TUBING CONNECTIONS A T PO WER UNIT This section ref ers to Figures 53 and 54. Y our VX Series power units are capable of being connected to the intake v acuum trunk line from either side. Select the intake connection to be used. On some installations, you ma y connect the vacuum air intak e into both intak es. 1. Using provided coupling (par t no . ...

  • NuTone VX1000C - page 33

    WIRING This section ref ers to Figures 55 and 56. Grounding Instructions—This appliance must be grounded. If it should malfunction or break down, grounding pro vides a path of least resistance f or electric current, to reduce the r isk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding ...

  • NuTone VX1000C - page 34

    Be sure all inlets are closed and soil bag (f or VX475, VX550 & VX1000 models) is in place. Check switch on po wer unit f or manual on/off operation. Check that indicator light on side of power unit is lit and is in g reen mode. Check each w all inlet to be sure contacts activate po wer unit when hose is inser ted and s witched on, if applicab ...

  • NuTone VX1000C - page 35

    T wo-Year Limit ed W ar r anty W ARRANTY OWNER: NuT one warrants to the original consumer purchaser of its products that such products will be free from defects in materials and workmanship for a period of two (2) years from the date of original purchase. THERE ARE NO OTHER W ARRANTIES, EXPRESSED OR IMPLIED, INCLUDING , BUT NOT LIMITED TO, IMPLIED ...

  • NuTone VX1000C - page 36

    36 T roub le 1. Loss or decrease of vacuum occurs. 2. P ower unit does not star t, or shuts off during nor mal operation with no LED showing red or illuminated. 3. Po wer unit f ails to stop when the hose is remov ed. 4. P ower unit shuts off during normal operation, lights on unit, wall v alv e and hose are all red. 5. F or VX550 & VX1000 Seri ...

  • NuTone VX1000C - page 37

    37 P ossible Remedy 1a. Remove disposab le filter bag or empty debris buc ket as described in Homeowner’ s Guide and install replacement. 1b . Inser t handle end of hose into utility v alv e at power unit. T ur n unit on. This will re verse normal air flow through the hose and dislodge any clogs . 1c. Inser t hose end into any inlet with pow er u ...

  • NuTone VX1000C - page 38

    38 NO TES ...

  • NuTone VX1000C - page 39

    39 NO TES ...

  • NuTone VX1000C - page 40

    W ARRANTY All VX P ow er Units are cov ered b y a NuT one 2, 4, or 8 year warranty . Ref er to y our Model Number f or which warranty y ou have . T ools and Accessories warranted f or one y ear from date of purchase. See page 35 for details . Product specifications subject to change without notice. 926 W EST S TAT E S TREET , H ARTFORD , WI 53027 W ...

Manufacturer NuTone Category Vacuum Cleaner

Documents that we receive from a manufacturer of a NuTone VX1000C can be divided into several groups. They are, among others:
- NuTone technical drawings
- VX1000C manuals
- NuTone product data sheets
- information booklets
- or energy labels NuTone VX1000C
All of them are important, but the most important information from the point of view of use of the device are in the user manual NuTone VX1000C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals NuTone VX1000C, service manual, brief instructions and user manuals NuTone VX1000C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product NuTone VX1000C.

Similar manuals

A complete manual for the device NuTone VX1000C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use NuTone VX1000C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of NuTone VX1000C.

A complete NuTone manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual NuTone VX1000C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the NuTone VX1000C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the NuTone VX1000C, that we can find in the current document
3. Tips how to use the basic functions of the device NuTone VX1000C - which should help us in our first steps of using NuTone VX1000C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with NuTone VX1000C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of NuTone VX1000C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning NuTone VX1000C?

Use the form below

If you did not solve your problem by using a manual NuTone VX1000C, ask a question using the form below. If a user had a similar problem with NuTone VX1000C it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)