Manual Friedrich MR30C3F

27 pages 1.58 mb
Download

Go to site of 27

Summary
  • Friedrich MR30C3F - page 1

    SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type CONTENTS SPECIFICATIONS .................... 1 DIMENSIONS ....................... 2 REFRIGERANT SYSTEM DIAGRAM .... 4 CIRCUIT DIAGRAM .................. 5 ERROR CONTENTS ................ 6 INDOOR PCB CIRCUIT DIAGRAM ..... 9 OUTDOOR PCB CIRCUIT DIAGRAM . . . 14 DISASSEMBLY ILLUSTRATION ....... 1 5 PA ...

  • Friedrich MR30C3F - page 2

    1 2006.03.15 SPECIFICATIONS INDOOR UNIT MW30C3F OUTDOOR UNIT MR30C3F COOLING CAPACITY 30,700 BTU/hr POWER SOURCE 208 V / 230 V FREQUENCY 60 Hz RUNNING CURRENT 15.2 A INPUT WATTS 3,460 W SEER 15.0 MOISTURE REMOVAL 9.7 Pts/hr (4.6 L/hr) AIR CIRCULATION-High 647 cfm (1,100 m 3 /hr) ELECTRICAL DATA COMPRESSOR FAN MOTOR DIMENSIONS TYPE Hermetic motor co ...

  • Friedrich MR30C3F - page 3

    OUTLINE AND DIMENSIONS Unit : inch (mm) INDOOR UNIT Model : MW30C3F 39-1/4" (998) 9" (228) 12-5/8" (320) 2 2006.02.22 ...

  • Friedrich MR30C3F - page 4

    Unit : inch (mm) OUTDOOR UNIT Model : MR30C3F 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 3 2006.03.15 ...

  • Friedrich MR30C3F - page 5

    REFRIGERANT SYSTEM DIAGRAM 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Cooling MW30C3F / MR30C3F Models : Refrigerant pipe diameter Liquid : 3/8" (9.52 mm) Gas : 5/8" (15.88 mm) 4 2006.02.22 ...

  • Friedrich MR30C3F - page 6

    CIRCUIT DIAGRAM 2006.02.22 5 ...

  • Friedrich MR30C3F - page 7

    CN1 1 B07B-9ASK CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 CN6 5P-SAN CN2 SJH20-05WS CN5 SJH20-06WS CN8 B06B-P ASK CN10 B06B-XARK CN3 2P-SCN CN1 2P-SAN CN13 B5P-SHF-1AA 1 2 1 2 1 2 3 4 5 CN3-1 BLACK CN ...

  • Friedrich MR30C3F - page 8

    5V VA 6 470V <TNR> R106 1.0K </2W>8 TM2 (3) D14 DAN202K Q1 1 DTC124EUA 1 2 3 3 2 1 2 3 1 Q10 DTC124EUA C54 0.01 <B> R1 14 390 <1/10W> 10 5 4 3 21 14 18 8 27 6 5 4 I C26-14 I C26-10 3 2 1 I C1-6 I C1-47 I C1-46 R105 10K <1/10W> 5V C50 0.01 <B> (95) R103 390 <1/10W> 280V 5V (90) I C27 PS2501L-1 <KD / KE> ...

  • Friedrich MR30C3F - page 9

    CN201 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261R 5V D201 SLR-325 D203 SLR-325 D202 SLR-325 5 4 6 1 2 3 7 2 1 3 VCC OUT GND INDICA T OR PCB ASSY K05CY -0500HSE-D0 8 2006.03.15 Model : MW30C3F ...

  • Friedrich MR30C3F - page 10

    TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 CAP ACITOR PCB ASSY K05FB-0500HUE-P0 ACTPM CONTROLLER PCB ASSY K05CU-0503HUE-C1 POWER SUPPL Y PCB ASSY K05CW-0503HUE-FL0 INVERTER ASSEMBL Y EZ-00502HUE Model : MR30C3F OUTDOOR PCB CIRCUIT DIAGRAM 9 2006.03.15 ...

  • Friedrich MR30C3F - page 11

    C64 10K <1/10W> C64 10K <1/10W> CONTROLLER PCB ASSY K05CU-0503HUE-C1 Model : MR30C3F 10 2006.03.15 ...

  • Friedrich MR30C3F - page 12

    TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 Model : MR30C3F 11 2006.03.15 ...

  • Friedrich MR30C3F - page 13

    POWER SUPPL Y PCB K05CW-0503HUE-FL0 Model : MR30C3F 2006.02.22 12 ...

  • Friedrich MR30C3F - page 14

    B B W13 VIOLET W12 WHITE R200 220K <2W> C200 C201 C202 C203 + + + + 660 / 450V x 4 SMOOTHING CIRCUIT B B W8 BLUE W7 YELLOW CAP ACITOR PCB ASSEMBL Y K05FB-0500HUE-P0 13 2006.03.15 Model : MR30C3F ...

  • Friedrich MR30C3F - page 15

    ERROR CONTENTS Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oeration Serial signal (forward) error, at operation start up Serial signal (forward) error, during operation Indoor unit thermistor error 2 flash 8 flash ...

  • Friedrich MR30C3F - page 16

    4 2 2 4 6 1 5 5 2006.03.15 15 DISASSEMBLY ILLUSTRATION Model : MW30C3F ...

  • Friedrich MR30C3F - page 17

    2006.02.22 16 Models : MW30C3F 8 31 35 36 34 29 30 27 25 28 32 33 9 ...

  • Friedrich MR30C3F - page 18

    26 23 22 Model : MW30C3F 2006.03.31 17 10 ...

  • Friedrich MR30C3F - page 19

    Model : MW30C3F 18 2006.06.13 46 48 52 55 40 42 41 53 39 37 38 47 ...

  • Friedrich MR30C3F - page 20

    Model : MR30C3F 19 2006.05.12 6 11 7 5 2 4 3 1 ...

  • Friedrich MR30C3F - page 21

    20 2006.05.12 9 8 10 13 15 ...

  • Friedrich MR30C3F - page 22

    21 2006.05.12 24 21 27 25 12 28 17 18 26 20 19 29 23 22 26 ...

  • Friedrich MR30C3F - page 23

    22 2006.06.13 46 47 48 41 34 39 36 38 42 37 45 35 33 40 31 CONNECTOR : BLUE CONNECTOR : ORANGE DISCHARGE TEMP THERMISTOR OUTDOOR TEMP THERMISTOR CONNECTOR : GREEN COMPRESSOR TEMP THERMISTOR CONNECTOR : RED HEA T EXCHANGER THERMIST OR CONNECTOR : RED PRESSURE SWITCH WIRE ...

  • Friedrich MR30C3F - page 24

    3$576/,67 ,1'22581,7 5HI 3DUW1R 2UG 1R 0:&) 4W  )52173$1(/727$/$66<   ,17$.(*5,//($66<   $,5),/7(5   &/$03(5*5,//(   5(&(,9(5:,1'2:  ...

  • Friedrich MR30C3F - page 25

    287'22581,7 5HI 3DUW1R 2UG 1R 05&) 4W  7233$1(/68%$66<   )52173$1(/0   )$1*8$5'   +$1'/(   6(59,&(3$1(/6$   5,*+73$1(/  ...

  • Friedrich MR30C3F - page 26

    9305642045 Remote control unit holder Name and Shape Part No. 9315023018 9315027160 0600185534 0700076046 9310519004 Remote control unit Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket STANDARD ACCESSORIES Tapping screw (small) 0700019036 25 2006.03.15 ...

  • Friedrich MR30C3F - page 27

    0602G3030 ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich MR30C3F can be divided into several groups. They are, among others:
- Friedrich technical drawings
- MR30C3F manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich MR30C3F
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich MR30C3F.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich MR30C3F, service manual, brief instructions and user manuals Friedrich MR30C3F. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich MR30C3F.

Similar manuals

A complete manual for the device Friedrich MR30C3F, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich MR30C3F by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich MR30C3F.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich MR30C3F - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich MR30C3F, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich MR30C3F, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich MR30C3F - which should help us in our first steps of using Friedrich MR30C3F
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich MR30C3F
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich MR30C3F in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich MR30C3F?

Use the form below

If you did not solve your problem by using a manual Friedrich MR30C3F, ask a question using the form below. If a user had a similar problem with Friedrich MR30C3F it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)