  • Yeoman YM-W9001FL - page 1

    Fr eestanding Stove INSTRUCTIONS FOR USE, INST ALLA TION AND SERVICING For use in GB & IE (Great Britain and the Republic of Ireland). This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance ...

  • Yeoman YM-W9001FL - page 2

    COVERING THE FOLLOWING MODELS: YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YM-W9001ERLC / YM-W9101FL / YM-W9101LC / YM-W9101ERFL /YM-W9101ERLC / YM-W9102FL/YM-W9102LC / YM-W9102ERFL /YM-W9102ERLC / YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL / YM-W9201ERLC /YM-W9201ERHC / YM-W9202FL / YM-W9202LC / YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC/ YM-W ...

  • Yeoman YM-W9001FL - page 3

    3 3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information. In the unlikely event of a problem, contact your installer or dealer for assistance: Is flue system correct for the appliance YES NO Flue swept and soundness test complete YES NO Smoke test completed on installed appliance YES NO Spi ...

  • Yeoman YM-W9001FL - page 4

    4 4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance. 1.3 Only use for domestic heating in accordance with these operating instructions. 1.4 You must ...

  • Yeoman YM-W9001FL - page 5

    5 5 USER INSTRUCTIONS AIRWASH & PRIMARY AIR CONTROLS 1.14 Use a gloved hand to operate air controls. The opposite end of the door tool can be used to operate Airwash controls. PR7518 Single Door Primary Control Open Two Door Primary Control Open Close Open Primary Air Control Airwash Control Primary Air Control PR7519 Airwash Control Open Close ...

  • Yeoman YM-W9001FL - page 6

    6 6 USER INSTRUCTIONS 3. RECOMMENDED FUELS 3.1 Wood Logs: • Burn only seasoned timber with a moisture content of less than 20% Wood Length Appliance Wood Length Exmoor 250mm Exe 300mm Devon 350mm County 400mm • Dry cut wood for 12 to 18 months before use Poor quality timber: — Causes low combustion efficiency — Produces harmful condensation ...

  • Yeoman YM-W9001FL - page 7

    7 7 USER INSTRUCTIONS • Leave the door slightly open as the fire establishes and the glass warms to avoid the build-up of condensation • Add larger pieces of wood Too many logs may smother the fire. Do not load fuel above the log guard and the secondary combustion holes at the back of the firebox. See Diagram 7 Secondary Combustion holes Log Gu ...

  • Yeoman YM-W9001FL - page 8

    8 8 Secondary Air: Fully Closed Primary Air: Adjust Secondary Air: Fully Closed Primary Air: Adjust Air Wash: 25% Open Air Wash: 25% Open 5.7 De-ash the fire bed before re-fuelling, see Section 7 Ash Removal. • Open the Primary air control fully to establish a glowing bed before adding new fuel • Burn new fuel at high output for a few minutes b ...

  • Yeoman YM-W9001FL - page 9

    9 7. ASH REMOVAL Do not allow ash to build up in the appliance as it will not burn properly and may cause damage. 7.1 Wood : • Open the door • Remove drop-in front plate, Diagram 10 PR7535 10 • Riddle the appliance using a poker or if a multi-fuel kit is fitted move the riddling lever back and forth •Remove ashpan and empty Warning: Heat ca ...

  • Yeoman YM-W9001FL - page 10

    10 c) It is repaired as required before re-use. Use only genuine Stovax replacement parts to keep your appliance in safe and efficient working order. 11. GENERAL CLEANING 11.1 Clean and inspect your appliance regularly, especially in periods of heavy use. Regular cleaning and maintenance will help give many years of safe use. • Allow appliance to ...

  • Yeoman YM-W9001FL - page 11

    11 13. CHIMNEY SWEEPING 13.1 To maintain safe and efficient use of the appliance the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep.* If the appliance is used continuously throughout the year or it is used to burn wood, more frequent sweeping is recommended. The best time to have the chimney swept is at t ...

  • Yeoman YM-W9001FL - page 12

    12 USER INSTRUCTIONS • Lift out the riddling mechanism and remove all ash • Replace riddling mechanism when cleaning is complete 16.3 Glass cracking: Do not over tighten the screws on the glass clips when replacing the glass as this causes stress and the intense temperature changes can cause the glass to crack. For replacement glass contact you ...

  • Yeoman YM-W9001FL - page 13

    YEOMAN EXMOOR/EXE/DEVON/COUNTY 13 TECHNICAL SPECIFICATION MODEL: Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC Devon – YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL / YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / ...

  • Yeoman YM-W9001FL - page 14

    14 SITE REQUIREMENTS YEOMAN STOVE DIMENSIONS PR7509 Description A B C D E F G H (dia) Exmoor FT 523 437 290 100 407 324 89 125 Exmoor LC 667 447 309 100 407 324 89 125 Exe FT 517 595 307 115 402 351 89 150 Exe LC 682 599 319 110 402 351 89 150 Devon FT 565 618 349 118 449 394 115 150 Devon LC 729 599 353 128 449 394 115 150 Devon HC 891 608 353 111 ...

  • Yeoman YM-W9001FL - page 15

    15 1. FLUE & CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks. 1.2 You must check the following: — The construction of the masonry chimneys, flue block ch ...

  • Yeoman YM-W9001FL - page 16

    16 2.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in the diagram opposite. 2.2 The building must have a suitable load-bearing capacity for the hearth and appliance. • Consult a structural engineer for advice before proceeding 2.3 When fitting into an exist ...

  • Yeoman YM-W9001FL - page 17

    17 SITE REQUIREMENTS WALLS NEXT TO HEARTH Solid, non-combustible material e.g. masonry or concrete Thickness W H C C 150mm minimum 150mm minimum PR7511 Position of Appliance & Hearth in relation to walls Requirement for the walls Distance of hearth from wall 'C' Distance of Appliance to wall Min thickness of Wall 'W' Min hei ...

  • Yeoman YM-W9001FL - page 18

    18 PRE-INSTALLATION CHECKS MODEL: Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC Devon – YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL / YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC / YM-W9202HC / YM-W ...

  • Yeoman YM-W9001FL - page 19

    19 PRE-INSTALLATION CHECKS 3.1 This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm 2 per kW of appliance rated output above 5kW. 3.2 Increase air supply provisions where a room contains multiple appliances. 3.3 If vents open i ...

  • Yeoman YM-W9001FL - page 20

    20 INSTALLATION INSTRUCTIONS LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations and standards*, along with any local regulations and working practices that may apply. Should any conflict occur between these instructions ...

  • Yeoman YM-W9001FL - page 21

    21 INSTALLATION INSTRUCTIONS Typical Top Flue Installation PR7515 600mm minimum 1000mm maximum unsupportable weight To chimney connection as detailed in building regulations Flue Pipe 915mm (3ft) Size Stovax Part No. 5" 4502 6" 4602 135 Elbow Size Stovax Part No. 5" 4512 6" 4612 1.3 Rear flue installation PR7512 Cap Self Tapping ...

  • Yeoman YM-W9001FL - page 22

    22 INSTALLATION INSTRUCTIONS PR7525 Baffle Extension Tubes Support Pin Rear Lip 3.2 The front lip of the baffle should point downwards. • Lift the baffle and slide the two baffle extension tubes off of the support pins on the sides of the firebox. The baffle can now be lifted clear of the support pins and rotated out through the front of the appl ...

  • Yeoman YM-W9001FL - page 23

    23 • Place the ashpan under the grate • Refit the drop in front plate • Check that the door closes and seals correctly County Model Rear Grate Front Grate Ashpan 5.3 • Place the rear grate in position on the steel runners as far back as it will go against the rear steel chamber • Place the front grate on the steel runners and locate the b ...

  • Yeoman YM-W9001FL - page 24

    24 COMMISSIONING COMMISSIONING 1.1 To commission: • Replace the firebricks, baffle, and log retainer • Check the door alignment and catch operation, adjust if required, see Maintenance & Servicing Section 8&9. Adjusting Door hinges • Check the soundness of door seals, castings and joints • C heck the operation of the air controls 1. ...

  • Yeoman YM-W9001FL - page 25

    25 25 1. ANNUAL SERVICE 1.1 At the end of the heating season strip, inspect and clean the appliance as detailed: • Allow appliance to cool • Remove all of the following internal parts; drop in front, log guard, baffle, firebricks. For Multi-fuel versions remove the complete grate and ash pan. See sections 2 - 5 on how to remove the log bar, baf ...

  • Yeoman YM-W9001FL - page 26

    26 26 MAINTENANCE and SERVICING 2. REMOVAL OF THE LOG GUARD 2.1 See Section 2 Fitting & Removal of Log Guard in Installation section. 3. FITTING AND REMOVAL OF THE BAFFLE 3.1 See Section 3 Fitting & Removal of The Baffle in Installation section. 4. FITTING AND REMOVAL OF FIREBRICKS 4.1 See Section 4 Fitting & Removal of Firebricks in In ...

  • Yeoman YM-W9001FL - page 27

    27 27 MAINTENANCE and SERVICING PR7531 Seal 12x3 Seal 14mm 2 Door 7.3 Remove the old rope and scrape old glue from the locating grooves. Clean the locating groove with a clean dry cloth to remove all old dust and debris. 7.4 Squeeze a generous bead of fresh Stovax Thermic Seal glue into the rope locating groove (part no. 5037). Press the new Stovax ...

  • Yeoman YM-W9001FL - page 28

    28 County only Exmoor, Exe & Devon Exmoor only 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 13 B 13 A1 9 25 24 22 17 18 19 20 22 23 21 23 28 BASIC SPARE PARTS LIST Exmoor, Exe, Devon, County S e e a S S e m b l y ...

  • Yeoman YM-W9001FL - page 29

    29 BASIC SPARE PARTS LIST D i A g r A m N o D e s c r i p t i o N e x m o o r p r o D u c t c o D e e x e p r o D u c t c o D e D e v o N p r o D u c t c o D e c o u N t y p r o D u c t c o D e 1 Flue Spigot assembly 5" ym-ym74545 6" ym-ym00545 6" ym-ym00545 6" ym-ym00545 2 t op plate CE ym-a9031Fl ym-a9131Fl ym-a9231Fl ym-a9331 ...

  • Yeoman YM-W9001FL - page 30

    30 BASIC SPARE PARTS LIST D i A g r A m N o D e s c r i p t i o N e x m o o r p r o D u c t c o D e e x e p r o D u c t c o D e D e v o N p r o D u c t c o D e c o u N t y p r o D u c t c o D e 1 Glass clamp screw ym-F00001 ym-F00001 ym-F00001 ym-F00001 2 Door Rope Seal Pack 5000 ym-e81001 ym-e81001 ym-e05002 3 Standard glass clamp ym-C00353 ym-C00 ...

  • Yeoman YM-W9001FL - page 31

    31 BASIC SPARE PARTS LIST Exe, Devon, County Double Door 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 21 9 D i A g r A m N o D e s c r i p t i o N e x e p r o D u c t c o D e D e v o N p r o D u c t c o D e c o u N t y p r o D u c t c o D e 1 Glass clamp screw ym-F00001 ym-F00001 ym-F00001 2 Door Rope Seal Pack ym-e82002 ym-e82002 ym-e05002 3 Stan ...

  • Yeoman YM-W9001FL - page 32

    32 32 SERVICE RECORDS 1st SERVICE Date of Service: ..................................... Next Service Due: ................................... Signed: ............................................ Dealer’s Stamp/HETAS Registration Number 3rd SERVICE Date of Service: ..................................... Next Service Due: .......................... ...

  • Yeoman YM-W9001FL - page 33

    33 33 ...

  • Yeoman YM-W9001FL - page 34

    34 34 Greg T aylor T echnical Director ...

  • Yeoman YM-W9001FL - page 35

    A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.com www.yeoman-stoves.co.uk ...

Manufacturer Yeoman Category Cooktop

Documents that we receive from a manufacturer of a Yeoman YM-W9001FL can be divided into several groups. They are, among others:
- Yeoman technical drawings
- YM-W9001FL manuals
- Yeoman product data sheets
- information booklets
- or energy labels Yeoman YM-W9001FL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Yeoman YM-W9001FL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Yeoman YM-W9001FL, service manual, brief instructions and user manuals Yeoman YM-W9001FL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Yeoman YM-W9001FL.

Similar manuals

A complete manual for the device Yeoman YM-W9001FL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Yeoman YM-W9001FL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Yeoman YM-W9001FL.

A complete Yeoman manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Yeoman YM-W9001FL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Yeoman YM-W9001FL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Yeoman YM-W9001FL, that we can find in the current document
3. Tips how to use the basic functions of the device Yeoman YM-W9001FL - which should help us in our first steps of using Yeoman YM-W9001FL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Yeoman YM-W9001FL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Yeoman YM-W9001FL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Yeoman YM-W9001FL?

Use the form below

If you did not solve your problem by using a manual Yeoman YM-W9001FL, ask a question using the form below. If a user had a similar problem with Yeoman YM-W9001FL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)