    SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 33 Direct Vent ZERO CLEARANCE By SHERWOOD INDUSTRIES LTD. an after market permanently located OWNERS MANUAL This appliance may be installed in manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with ...

  • Enviro EG 33 - page 2

    SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIROGAS” STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required ...

  • Enviro EG 33 - page 3

    TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Assembly Instruction 3 Deciding where to locate y our stove 4 Mobile Home Information 4 Installation 5-6 Mantle and Vent restrictions 7 Flue Collar Installation and Vent terminal clearances 8 Planning your installation 9-13 Installation of Log Sets and Embers 14 Operating Instructions 15 Maint ...

  • Enviro EG 33 - page 4

    4 DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: Front Width: 36 5/8”/ 93 cm Rear Width: 36 5/8”/ 93 cm Height: 32 1/4”/ 82 cm Depth 13 11/16”/ 34.77 cm Shipping Weight: 132 lbs/59.9 kg CLEARANCES: A. Side wall to stove 2”/ 5 cm B. Rear wall to stove 1”/ 2.5 cm C. Floor to stove 0”/ 0 cm D. Corner clearance 1”/ 2.5 cm Maintain suff ...

  • Enviro EG 33 - page 5

    INSTALLATION: THIS UNIT HAS BEEN DESIGNED TO BE INSTALLED IN MANY LOCATIONS. BECAUSE THIS UNIT IS A ZERO CLEARANCE FIREPLACE IT MAY BE INSTALLED IN A WOOD FRAMED COMBUSTIBLE CHASE, AS SHOWN. FRA MING DIMENSIONS: WIDTH: 35 3/8” (89.85 CM) HEIGHT: 31 3/4” (80.65 CM) (INCLUDING FINISHED HEA RTH HEIGHT) DEPTH: 13 3/4” (34.93 CM) NOTE: When prepar ...

  • Enviro EG 33 - page 6

    Place the unit into the framed opening. Nail or screw the unit to the frami ng using the nailing flanges provided. MA KE SURE THA T THE UNIT IS LEVEL AND PLUMB BEFORE NA ILIN G OR SCREWING TO THE FRA MING MEMBERS. ALSO INSURE THA T THE BOTTOM OF THE UNIT IS L EVEL WITH THE FINISHED HEA RTH HEIGHT. Once the unit has been secured, install all venting ...

  • Enviro EG 33 - page 7

    REQUIRED MANTLE CLEARANCES MAKE SURE THAT THE MANT LE INSTALLATION STAYS WITHIN THE SHADED AREA IN THE DIAGRAM PROVIDED. THE MAXIMUM ALLOWABLE MANTLE WI DTH IS 10” (25.4 CM) THE M INIMUM HEIG HT FROM TH E TOP OF TH E SURROUND PANEL TO A 10” (25.4 CM) WIDE MANTLE IS 11” (27.94 CM) VENT RESTRICTIONS: THIS SECTION IS DESIGNED TO SH OW THE MINIMU ...

  • Enviro EG 33 - page 8

    FLUE COLLAR INSTALLATION THIS UNIT CA N BE VENTED THREE DIFFERENT WA YS: ( HORIZONT AL, VERTICAL/HORIZONTAL OR VERTICALLY) The flue collar has been installed on the rear of the appliance at the factory. It can used in this location or the flue collar can be installed on the top of the firebox for vertical installations. 1. Remove the 6 5/8” outer ...

  • Enviro EG 33 - page 9

    These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT T YPE “GS” PIPE FOR GAS STOVES. Kits are available for vertical venting or hor izontal venting. It is re commended that a bead of RTV High Temperature Silicone be applied to each outer vent joint and MILPAC to eac h inner joint before installation. BEFORE BEGI ...

  • Enviro EG 33 - page 10

    When planning your installation, it w ill be necessary to select the proper length of vent pipe fo r your particular requirements . It is important to note when passing through a w all, the maximum allowable w all thickne ss is 10-inches (254 mm), 1 1/2” inches clearance to combustibles must be maintai ned. Select the amount of vertical rise desi ...

  • Enviro EG 33 - page 11

    F I G - 1 1 F I G - 1 2 F I G - 1 3 FIG-14 NOTES: (1) The four wood screw s provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) For buildings with vinyl siding, a vinyl siding st andoff (950), should be installed between the vent cap and the exterior wall FIG-12. Attach the vinyl sid ...

  • Enviro EG 33 - page 12

    VERTICAL INSTALLATION STEP 1 . Check the instructions for required clearances (air spaces) to combustibles w hen passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combus tible surfaces. Do not pack air spaces with insulation. STEP 2. Set the gas appliance in the desired location. Drop a plum b bob down from the cei ...

  • Enviro EG 33 - page 13

    NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the v ent pipe every 3 feet, to avoid excessive stress on the elbows, and po ssible separation. Wall straps are available for this purpose. FIG-18 (2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbow s. The 45 ° degree elbow ...

  • Enviro EG 33 - page 14

    INSTALLATION OF LOGSET and EMBERS INSTA LLING THE GLOWING EMBERS and LOGSET A bag of ceramic fiber embers is provided for use on the front burner ember tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. Use only a single layer. Do not pile ...

  • Enviro EG 33 - page 15

    OPERATING INSTRUCTIONS FOR YOUR SA FETY READ BEFORE OPERA TING WA RNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by follow ing these instructions exactly. B) BEFORE LIGHTI NG smell a ...

  • Enviro EG 33 - page 16

    ROUTINE MAINTENANCE and TECHNICAL Periodically check to ensure that your sy stem is clean. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no y ellow tips. OPENING THE DOOR Turn unit off and wait until the appliance h ...

  • Enviro EG 33 - page 17

    TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark igniter Defective piezo igniter Check connections to igniter -If igniter connections are good but there is no spark-replace igniter Broken spark electrode -Check for broken ceramic insulation replace, electrode if broken Miss-aligned spa ...

  • Enviro EG 33 - page 18

    GAS LINE CONNECTION WARNING: Only persons licensed to w ork with gas piping may make the necessary gas connections to this appliance. GA S LINE CONNECTION • This stove is equipped with a 3/8” female NPT thread located on the right hand side of the gas valve. Consult your local authorities codes or the CA N/CGA B 149 (1 or 2) installation code i ...

  • Enviro EG 33 - page 19

    ELECTRICAL The ENVIROGAS EG 22.Z/CLEARANCE .DV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be el ectrically connected and grounded in accordanc e w ith local codes or in the absence of l ...

  • Enviro EG 33 - page 20

    FUEL CONVERSION “Warning” This conversion kit shall be installed by a qualified service technician in accordance w ith the manufacturer’s ins tructions and all applicable codes and re quirements of the authority hav ing jurisdiction. If the information in these instructions is no t followed exactly, a fire, explosion or CO poiso ning may resu ...

  • Enviro EG 33 - page 21

    21 WARRANTY Sherwood Industries Ltd. offers a *Lifet ime Warranty on this gas product. T he lifet ime w arranty covers the appliance for a period of seven years from the date of installation. This w arranty applies only to the original owner in the original location Covered under the lifetime warranty are, Surround Panels and Chassis and H eat Exch ...

  • Enviro EG 33 - page 22

    INSTALLATION DATA SHEET The installer for warranty purposes and future reference must re cord the following information. Please keep this information f or your records. Model: EG 33 Zero Clearance Direct Vent Name of Owner: __________________________________________ Address: __________________________________________ _______________________________ ...

Manufacturer Enviro Category Ventilation Hood

Documents that we receive from a manufacturer of a Enviro EG 33 can be divided into several groups. They are, among others:
- Enviro technical drawings
- EG 33 manuals
- Enviro product data sheets
- information booklets
- or energy labels Enviro EG 33
All of them are important, but the most important information from the point of view of use of the device are in the user manual Enviro EG 33.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Enviro EG 33, service manual, brief instructions and user manuals Enviro EG 33. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Enviro EG 33.

A complete manual for the device Enviro EG 33, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Enviro EG 33 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Enviro EG 33.

A complete Enviro manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Enviro EG 33 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Enviro EG 33, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Enviro EG 33, that we can find in the current document
3. Tips how to use the basic functions of the device Enviro EG 33 - which should help us in our first steps of using Enviro EG 33
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Enviro EG 33
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Enviro EG 33 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Enviro EG 33?

Use the form below

If you did not solve your problem by using a manual Enviro EG 33, ask a question using the form below. If a user had a similar problem with Enviro EG 33 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)