Manual Bard W24A to W70A

8 pages 0.22 mb
Download

Go to site of 8

Summary
  • Bard W24A to W70A - page 1

    Form No. S3408-101 1 Supersedes S3408-710 Page 1 of 8 Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standa ...

  • Bard W24A to W70A - page 2

    Form No. S3408-101 1 Supersedes S3408-710 Page 2 of 8 S L E D O M D - 1 A 4 2 W F - 1 A 4 2 W F - 1 L 4 2 W D - 1 A 0 3 WF - 1 A 0 3 WD - 1 A 6 3 WE - 1 A 6 3 W F - 1 A 6 3 W F - 1 L 6 3 W z H 0 5 - g n i t a R l a c i r t c e l E 1 - 0 2 2 / 0 4 2 3 - 0 8 3 / 5 1 4 1 1 - 0 2 2 / 0 4 2 3 - 0 8 3 / 5 1 4 1 1 - 0 2 2 / 0 4 2 3 - 0 0 2 / 0 2 2 3 - 0 8 ...

  • Bard W24A to W70A - page 3

    Form No. S3408-101 1 Supersedes S3408-710 Page 3 of 8 V entilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality r equirements. Standard on all units is the barometric fresh air damper. All packages can be ordered built-in at the factory or can be easily ...

  • Bard W24A to W70A - page 4

    Form No. S3408-101 1 Supersedes S3408-710 Page 4 of 8 ) m m ( s e h c n I - s e c n a r a e l C d n a s s e c c A e c i v r e S r o f d e r i u q e R w o l f r i A r e s n e d n o C e t a u q e d A S L E D O M E D I S T F E L E D I S T H G I R A 6 3 W , A 0 3 W , A 4 2 W L 6 3 W , L 4 2 W ) 0 8 3 ( 5 1) 0 1 5 ( 0 2 A 0 7 W , A 0 6 W , A 8 4 W , A 2 ...

  • Bard W24A to W70A - page 5

    Form No. S3408-101 1 Supersedes S3408-710 Page 5 of 8 NOTE: All wiring must conform to NIC/EIC latest edition. IMPORT ANT : While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wi res in accordance with the National Electrical Code & all local codes. l e d o M d e t a R ...

  • Bard W24A to W70A - page 6

    Form No. S3408-101 1 Supersedes S3408-710 Page 6 of 8 Above data is with 1" (25mm) standard disposable filter and 1" (25mm) washable filter . For optional 2" (51mm) pleated filter - reduce ESP by .15” (37.33Pa). See installation instructions for maximum ESP information on various KW application. P S E s e h c n I n i H 2 O ) a P ( ...

  • Bard W24A to W70A - page 7

    Form No. S3408-101 1 Supersedes S3408-710 Page 7 of 8 1 Below 65°F (18.3C), unit requires a factory or field installed low ambient control. 2 Return air temperature. l e d o M B W / B D 2 2 2 2 2 g n i l o o C y t i c a p a C E R U T A R E P M E T R O O D T U O 1 1 1 1 1 ) C ° 9 . 3 2 ( F ° 5 7 ) C ° 4 . 9 2 ( F ° 5 8 ) C ° 0 . 5 3 ( F ° 5 9 ...

  • Bard W24A to W70A - page 8

    Form No. S3408-101 1 Supersedes S3408-710 Page 8 of 8 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Since 1914 . . . Moving ahead, just as planned. Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency i ...

Manufacturer Bard Category Air Conditioner

Documents that we receive from a manufacturer of a Bard W24A to W70A can be divided into several groups. They are, among others:
- Bard technical drawings
- W24A to W70A manuals
- Bard product data sheets
- information booklets
- or energy labels Bard W24A to W70A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bard W24A to W70A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bard W24A to W70A, service manual, brief instructions and user manuals Bard W24A to W70A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bard W24A to W70A.

Similar manuals

A complete manual for the device Bard W24A to W70A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bard W24A to W70A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bard W24A to W70A.

A complete Bard manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bard W24A to W70A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bard W24A to W70A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bard W24A to W70A, that we can find in the current document
3. Tips how to use the basic functions of the device Bard W24A to W70A - which should help us in our first steps of using Bard W24A to W70A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bard W24A to W70A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bard W24A to W70A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bard W24A to W70A?

Use the form below

If you did not solve your problem by using a manual Bard W24A to W70A, ask a question using the form below. If a user had a similar problem with Bard W24A to W70A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)