Manual SUPER MICRO Computer SSE-G48-TG4

27 pages 1.47 mb
Download

Go to site of 27

Summary
  • SUPER MICRO Computer SSE-G48-TG4 - page 1

    Release: 1.0c 1 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 2

    Release: 1.0c 2 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 3

    Release: 1.0c 3 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  The information in this User’s Manual has been carefully rev iew ed and is believed to be accurate. The vendor assumes no respon si bility for any inaccuracies that may be contained in this document, ma kes no co mmitment to update or to keep curr ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 4

    Release: 1.0c 4 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Contents 1 Introduction ................................................................................................................ . 5 2 Basic Configurations ..................................................................................... ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 5

    Release: 1.0c 5 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  1 Introduction This document is designe d to provide Supermicro switch users with the information required to configure the basic functionalities on the switch th rough its Web gra phical user in terface (GUI). Supermicro Switch products can be conf ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 6

    Release: 1.0c 6 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2 Basic Configurations 2.1 Login Page When you type the switch IP address into the bro wser, the following Login page appe ars. Fig 1: Login page Enter the User Name and Password and click on the Login butto n. This User Name and Password are both u ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 7

    Release: 1.0c 7 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide   Middle Configuration Links Table Except for the Page Top LED Display section, the Home page is same for all the switch product s SSE-G48-TG4, SSE-G24-TG4, SSE-X24S, SSE-X24SR, SSE-X3348S, SSE-X3348SR, SSE- X3348T, SSE-X3348TR, SBM-GEM-X2C, SBM- ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 8

    Release: 1.0c 8 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  The Logout link provides a means of signing out of the manageme nt web application. It returns to the login screen requesting a user name and password for login. 2.2.2 Page Top LED Display This part of the screen displays the port status of the swit ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 9

    Release: 1.0c 9 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.2.3 Left Side Tree The Left Side Tree display on the left side of t he page provide s qui ck acce ss to configuration pages. This tree is organized based on the featur es supported in th e swit ch. The main features are categorized as follows:  ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 10

    Release: 1.0c 10 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.3 Management IP Address Note : The default management IP address fo r all Supermicro switch produ cts i s: 192.168.100.102 . Swit ch Management IP Interface SSE-G24-TG4 SSE-G48-TG4 The management IP address is configured for VLAN 1. All front 1-G ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 11

    Release: 1.0c 11 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.3.1 Changing the Management IP Address & Gateway The management IP address and defaul t gateway can be configured in the System M gmt  Management IP page . Fig 3: Management IP Page  IP Address Mode – For a static IP addresse s use th ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 12

    Release: 1.0c 12 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.4 User Accounts The default administrative user name for all Super micro switch es is ADMIN and the pa ssword for all these switches is also ADMIN. The passwor d for this ADMIN user can b e ch anged in the page System Mgmt  Management Security ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 13

    Release: 1.0c 13 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.5 Interface MTU and Jumbo Frames The interface MTU can be change d in Layer2 M gmt  Port Manager  Basic Settings page. The default MTU is 1500 bytes. The ma ximum MTU supported is 9202. The Supermicro switch M TU refers only to the layer 2 ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 14

    Release: 1.0c 14 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Interfaces can be given a description o r name in te xt. This helps users to identify or rememb er the interface connections with other co mpone nts on the network. The interfa ce description can be configured in Layer2 Mgmt  Port Manager  Ba ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 15

    Release: 1.0c 15 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.7 Stacking The SSE-G24-TG4 and SSE-G48-TG4 switches support stacking of up to 16 switches. SBM- GEM-X2C, SBM-GEM-X2C+ sup port stacking of up to 8 swit ches. Stacking can be conf igured from the System Mgmt  Stack  Stack Settings page . Fig ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 16

    Release: 1.0c 16 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Note: 1. Do not use the same switch ID for mul t iple switches on the stack. 2. All switches in the stack can only be configured through the master switch. 3. Make sure all stacked switches run the same ve rsion of firm ware ! 4. Only the same swit ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 17

    Release: 1.0c 17 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  In the Upstream Interfaces field and Do wnstream Interfaces fields, list the po rts as comma separated without space chara cters. For example to choose port s gi0/1 to gi0/5 and gi0/10 as downstream ports, configure the Downstream Interfaces field ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 18

    Release: 1.0c 18 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.9 Saving Configurations Switch configurations can be save d on the System Mgmt  File Management page. You can save a currently running swit ch configuration in one of thre e ways.  Save Startup Config – This option saves the current runni ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 19

    Release: 1.0c 19 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.10 Upgrading Firmware Switch firmware can be upgraded in the System Mgmt  Firmware Upgrade page. Flash Area – The default selection is Normal to upgrade firmware i n normal flash area. To upgrade firmware in the fallback flash area, choose F ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 20

    Release: 1.0c 20 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  2.11 Resetting to Factory Defaults Supermicro switches can be rese t to factory defaults in the System M gmt  System Settings page. This page has a button that you c an press to allow a “Reset To Fa ctory Defaults”. This will clear all infor ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 21

    Release: 1.0c 21 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  3 VLAN Configurations The SSE-G24-TG4, SSE-G48-TG4, SBM-GEM -X2C, SBM-GEM-X2C+ and SB M-GEM-X3S+ switches support 1024 static VLANs. The SSE-X24S, SSE-X24SR, SSE-X3348S, SSE-X3348SR, SSE-X3348T, SSE-X3348TR and SBM-XEM -X10SM switches support 4K st ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 22

    Release: 1.0c 22 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide   Member Ports – Provide all the member ports of thi s VLAN including tagged and untagged member ports.  Untagged Ports – These are the member po rts that need to be configured as u ntagge d ports. If all the ports of this VLAN are untagge ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 23

    Release: 1.0c 23 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  4 Link Aggregation (LA) Link Aggregation (LA) is a method of combinin g multiple parallel physi cal conn ections into a single logical connection(tr unk), thus all owing increased bandwidt h for a particular network path beyond what a single conn e ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 24

    Release: 1.0c 24 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Fig 13: LA Status Page 4.2 Creating a Port Channel A port channel can be created in the Layer2 Mgmt  LA  Interface Setting s page. ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 25

    Release: 1.0c 25 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  Fig 14: Port Channel Page To create any port channel, enter the Port Channel ID in the page-top dialog bo x and click Add . ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 26

    Release: 1.0c 26 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  4.3 Associating a Port Channel with Ports Once a port channel is created in the port chan nel page, it can be asso ciated with the require d physical ports. This can be done in the L ayer2 Mgmt  LA  Port Settings page. Configure Port Channel ...

  • SUPER MICRO Computer SSE-G48-TG4 - page 27

    Release: 1.0c 27 / 27 Supermicro  Switch  Web  GUI  Quick  Configuration  Guide  4.4 Configuring Port Channel Parameters Once a port channel is created and associate d with the required ports, y ou can config ure the port channel parameters. If necessary configure the MTU of the port cha nnel in the Port Cha nnel page (Fig 14). ...

Manufacturer SUPER MICRO Computer Category Switch

Documents that we receive from a manufacturer of a SUPER MICRO Computer SSE-G48-TG4 can be divided into several groups. They are, among others:
- SUPER MICRO Computer technical drawings
- SSE-G48-TG4 manuals
- SUPER MICRO Computer product data sheets
- information booklets
- or energy labels SUPER MICRO Computer SSE-G48-TG4
All of them are important, but the most important information from the point of view of use of the device are in the user manual SUPER MICRO Computer SSE-G48-TG4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SUPER MICRO Computer SSE-G48-TG4, service manual, brief instructions and user manuals SUPER MICRO Computer SSE-G48-TG4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SUPER MICRO Computer SSE-G48-TG4.

A complete manual for the device SUPER MICRO Computer SSE-G48-TG4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SUPER MICRO Computer SSE-G48-TG4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SUPER MICRO Computer SSE-G48-TG4.

A complete SUPER MICRO Computer manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SUPER MICRO Computer SSE-G48-TG4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SUPER MICRO Computer SSE-G48-TG4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SUPER MICRO Computer SSE-G48-TG4, that we can find in the current document
3. Tips how to use the basic functions of the device SUPER MICRO Computer SSE-G48-TG4 - which should help us in our first steps of using SUPER MICRO Computer SSE-G48-TG4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SUPER MICRO Computer SSE-G48-TG4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SUPER MICRO Computer SSE-G48-TG4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SUPER MICRO Computer SSE-G48-TG4?

Use the form below

If you did not solve your problem by using a manual SUPER MICRO Computer SSE-G48-TG4, ask a question using the form below. If a user had a similar problem with SUPER MICRO Computer SSE-G48-TG4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)