    VORTEX USER MANU AL USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 1 INFORMA TION FOR USE FOR MODELS VORTEX 6, VORTEX 4, V ORTEX 2.6 and V ORTEX 200V VUM_GB_2005-2008-R4_11-2008 © Copyright 2008 by CAMC O Produktions- und V ertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5, D-57482 Wenden, Germany T elephone +49 (0) 2762 408-0 ...

  • Camco 32 dB - page 3

    IMPORT ANT SAFET Y INSTRUCTIONS USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 2 IMPORT ANT SAFETY INSTRUCTIONS 1) Read the information for use (user manual). 2) Please keep this user manual in a safe place during the lifetime of the am- plifi er . The user manual forms an integral part of the amplifi er . Reselling of the amplifi er is only possible ...

  • Camco 32 dB - page 4

    CAUTION – RISK OF ELECTRIC SHOCK – DO NO T OPEN. W ARNING – TO PREVENT FIRE OR SHOCK HAZARD , DO NOT EXPOSE THIS AMPLIFIER T O RAIN OR MOISTURE. CAUTION – HIGH V OL T AGE HAZARDS EXIST WITHIN THIS PRODUCT . REFER ALL SERVICING TO AUTHORISED PERSONNEL. CA UTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALE ...

  • Camco 32 dB - page 5

    SAFET Y USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 4 7. Lightning For added pr otec tion of this amplifi er during lightning storms, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the amplifi er due to lightning and power- line surges. Disconnection from the mains power ...

  • Camco 32 dB - page 6

    EC DECLARA TION OF C ONFORMIT Y USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 5 EC Declaration of Conformity in accordance t o EC Direc tives: electro-magnetic compatibility (Council Directive 89/336/EEC, as amended by Directives 92/31/EEC and 93/68/EEC); low-voltage electrical equipment (Council Directive 73/23/EEC ) Manufacturers Name: CAMC O Produkti ...

  • Camco 32 dB - page 7

    C ONTENTS USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 6 IMPORT ANT SAFETY INSTRUCTIONS EXPLANA TION OF SYMBOLS / SAFET Y EC DECLARA TION OF CONFORMIT Y CONTENTS 1 WEL COME 1.1 Welcome to CAMC O 1.2 Unpacking 1.3 The Amplifi er 2 F ACILITIES 2.1 VORTEX – The F ront 2.2 VORTEX – The Rear 2.3 F ac tory Settings 3 INST ALLA TION 3.1 Mains Supply 3.2 ...

  • Camco 32 dB - page 8

    1 WEL COME USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 7 1.1 Welcome to CAMC O Established in 1983, CAMCO has gained worldwide experience with professional sound reinforcement technology. Within the audio market, CAMCO specialises in the production and marketing of high quality power amplifi ers and sound systems for use both on tour and in static in ...

  • Camco 32 dB - page 9

    1 WEL COME USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 8 1.3 The Amplifi er The VORTEX is a Class-H po wer amplifi er with a power output of : VORTEX 200V 3,2 kW per channel @ 4 Ω 6,4 kW in Mono-Bridge @ 8 Ω 6,4 kW in Parallel-Mono @ 2 Ω VORTEX 6 3 kW per channel @ 2 Ω 6 kW in Mono-Bridge @ 4 Ω 6 kW in Parallel-Mono @ 1 Ω VORTEX 4 2 kW p ...

  • Camco 32 dB - page 10

    12 3 4 5 6 7 8 91 0 1 1 15 14 12 13 16 18 19 20 17 24 22 23 21 MODEL: OUTPUT PWR PER CH/IMP: MADE IN GERMANY SER. NO.: 2 F A CILITIES USER MANUAL VORTEX 6, 4, 2.6 and 200V P. 9 2.1 VORTEX – The F ront 1 On/Off Switch 2 Volume Control – Channel A 3 Volume Control – Channel B 4 On LEDs (multifunctional) 5 Signal LEDs 6 Clip LEDs (multifunctiona ...

  • Camco 32 dB - page 11

    2 F A CILITIES USER MANUAL VORTEX 6, 4, 2.6 and 200V P .10 2.3 F ac tory settings VORTEX amplifi ers are delivered with the following factory settings Fron t panel: On/Off Switch Off Amplifi er is switched off Rear panel Input Ground Lift Grounded Optional Featur e Circle Mode Stereo Limiter SpP Gain 26 dB ...

  • Camco 32 dB - page 12

    MODEL: OUTPUT PWR PER CH/IMP: MADE IN GERMANY SER. NO.: VORTEX-200 V 230 V ~ 50/60 Hz 12 A 1700 W 3200 W/4O h m xxxxxxx MODEL: OUTPUT PWR PER CH/IMP: MADE IN GERMANY SER. NO.: VORTEX-2.6 230 V ~ 50/60 Hz 7,2 A 1005 W 1500 W / 1,8 Ohm xxxxxxx MODEL: OUTPUT PWR PER CH/IMP: MADE IN GERMANY SER. NO.: VORTEX-4 230 V ~ 50/60 Hz 10 A 1450 W 2000 W/2O h m ...

  • Camco 32 dB - page 13

    437,0 mm 446,0 mm 422,0 mm 76,2 mm 10,5 mm 442,0 mm 76,2 mm 88,9 mm 465,0 mm 10,5 mm 3 INST ALLA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .12 Amplifi er switched off Amplifi er switched on (On LED is lighting up) 3.3 Mounting Use four screws and washers when mounting the amplifi er to the front rack rails. For mobile use , the amplifi er sh ...

  • Camco 32 dB - page 14

    DO NO T REMOVE MAINS CONNECT OR GROUND IT IS ILLEGAL AND DANGEROUS to Pin 1 of the XLRs 3 INST ALLA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .13 3.4 Cooling Under normal operation of the power amp, overheating should never be a problem. The air is taken in from the front and out through the back. It is of course essential that while the power a ...

  • Camco 32 dB - page 15

    A (L) B (R) VORTEX Z ≥ *Z min Z ≥ *Z min VORTEX A B Z res ≥ 0,5*Z min Input Ground Lift Input Ground Lift in position: grounded LINK B Input Channel B 2 3 1 1 3 22 3 1 To Channel B To Channel A Input Channel A LINK A 3 1 2 3 INST ALLA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .14 3.8 Mode Selector The switch on the rear panel changes the o ...

  • Camco 32 dB - page 16

    VORTEX A B Z ≥ 2*Z min Bottom SPEAKON Upper SPEAKON Input Channel A Input Channel B 3 INST ALLA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .15 mode is useful when, for example, 3 identical loudspeakers are to be operated with the same power . 3.9.4 Mono-Bridge Operation One-channel mono bridged operation. The second channel processes the same i ...

  • Camco 32 dB - page 17

    3 INST ALLA TION / 4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .16 W ARNING ! SPEAK ON connectors marked with the lightning fl ashes indicate high vol- tages that are potentially life threa tening. Wiring to these terminals requires installa tion by an instruc ted person or the use of ready-made leads or cords. Custom wiring should only b ...

  • Camco 32 dB - page 18

    4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .17 4.1.2 Gain Selector This switch on the rear of the V ORTEX allows the maximum amplifi cation attainable to be set directly in the input stage. The VORTEX amplifi er has a 26 dB and 32 dB voltage gain setting along with a 1,4 V sensitivity setting. 4.1.3 Gain and Input Sensitivity The table ...

  • Camco 32 dB - page 19

    4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .18 4.2.2 Signal LEDs The green Signal LED is illuminated when the voltage lev el at the output reaches approx. 4 V ; this corresponds to a power of approx. 4 W ov er a 4 Ohm resistor . 4.2.3 Clip LEDs (multifunctional) The colour of the bi-coloured (green/r ed) LED changes between red, green and ...

  • Camco 32 dB - page 20

    4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .19 4.3.4 Speaker Protect Limiter Whenever the SOA pr otec tion of the power amp switches back the current rail there could be a small clipping at the output; but the microprocessor is also triggered by this protection and will reduce the signal lev el immediately to minimise the effect. The user ...

  • Camco 32 dB - page 21

    4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .20 4.4.3 Mains F ailure Detec tion Mains F ailure Detec tion is always operative . When the mains supply is interrupted for about 2 mains cycles, the amplifi er will switch off. When the mains voltage returns to a normal v alue, a soft star t occurs. 4.4.4 Fuse P rotection The aver age mains cu ...

  • Camco 32 dB - page 22

    3 4 5 1 2 4 OPERA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .21 VORTEX Filter A ssembly 1 Clip Apertures 2 Injection Moulded Cradle 3 Foam F ilter 4 Injection Moulded Surround 5 Injection Moulded CAMCO Badge 4.7 Filter Cleaning The air intake on the front of your V ORTEX is fi tted with a removable fi lter system. I f the fi lter becomes clog ...

  • Camco 32 dB - page 23

    5 OPTIONS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .22 5.1 E.U.I.2 (Extended User Interface) CAUTION! Alw ays switch off and unplug the V ORTEX from mains, before making alterations to the E.U.I. card. The E.U.I. card contains the Rear XLR Panel as standard. Other input cards are available (See 5.1.1 What A re The Possibilities Using The E.U.I.2?). ...

  • Camco 32 dB - page 24

    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 5 OPTIONS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .23 5.2.2 CAI Address Settings The CAI address selection procedure will not affect the operation of the V ORTEX but whilst this procedure is active, the volume cannot be adjusted by using the pots. Briefl y press the Enter-Swit ch . This push button swit ch c ...

  • Camco 32 dB - page 25

    5 OPTIONS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .24 5.2.3 CAI Status Indicator This green LED indicates the presence of c ommunication between PC and the amp. ...

  • Camco 32 dB - page 26

    Operating Status LED Sequence ( ) = fl ash, (__) = off Description of repeated sequences Normal (no failure) Permanently lit Power F ail (i.e. switch off ) Short 50 ms fl ash + 950 ms pause High T emperature signal attenuation 750 ms fl ash + 250 ms pause Over T emperature main SMPS off 250 ms fl ash + 750 ms pause DC reason unknown 250 ms fl ...

  • Camco 32 dB - page 27

    6 TROUBLESHOO TING USER MANUAL VORTEX 6, 4, 2.6 and 200V P .26 6.2 Problem: No Sound Indication: On LEDs not lit Clip LEDs not lit Check AC plug. Confi rm that AC outlet works by plugging in another devic e. Indication: On LEDs lit Signal LED not lit M ake sure the signal source is operating and try another cable. Check position of V olume Pots. I ...

  • Camco 32 dB - page 28

    6 TROUBLESHOO TING USER MANUAL VORTEX 6, 4, 2.6 and 200V P .27 6.6 Problem: Hiss Unplug the amplifi er input to check that the hiss is coming from the source or from a device upstream. Erratic or popping noises indicate an electronic fault in the offending unit. T o keep the noise fl oor low , oper ate the primar y signal source at full level, wi ...

  • Camco 32 dB - page 29

    7 SPECIFICA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .28 Output Pow er 1 kHz, THD ≤ 0,1 %, in mono-bridge mode VORTEX 2.6 1 x 2600 W @ 4 Ω 1 x 1 500 W @ 8 Ω VORTEX 4 1 x 4000 W @ 4 Ω 1 x 3000 W @ 8 Ω VORTEX 6 1 x 6000 W @ 4 Ω 1 x 4200 W @ 8 Ω VORTEX 200V * 1 x 6400 W @ 8 Ω 1 x 3800 W @ 16 Ω 1 kHz, THD ≤ 0,1 %, both channels ...

  • Camco 32 dB - page 30

    7 SPECIFICA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .29 Frequency Range 20 Hz - 20 kHz ± 0,15 dB 8 Ω , 10 dB below rated pow er Input Impedance 40 k Ω balanced V oltage Gain selectable: 26 dB, 32 dB, or 1,4 V input sensitivity Protection Circuits inrush-current limitation, temperature monitoring of transf ormers and heat-sinks, output DC ...

  • Camco 32 dB - page 31

    Hz Hz -180 +1 80 -135 -90 -45 +0 +4 5 +9 0 +1 35 Hz -110 -10 -100 -90 -80 -70 -60 -50 -40 -30 -20 20 20k 50 100 200 500 1k 2k 5k 10k Hz 20 50 100 200 500 1k 2k 5k 10k 20k 8 MEASUREMENTS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .30 Figure 8.1 Gain vs. frequenc y (Ch1, Ch2 ) (Measurements of a typical performance of a VORTEX 6 ) Figure 8.3 Phase vs. f ...

  • Camco 32 dB - page 32

    Vrm s -120 -20 -11 0 -100 -90 -80 -70 -60 -50 -40 -30 dB 1 00u 5 200u 500u 1m 2m 5m 1 0 m 20m 50m 100m 200m 500m 1 2 Hz dB 20 10k 50 100 200 500 1k 2k 5k -120 -20 -1 10 -100 -90 -80 -70 -60 -50 -40 -30 Hz Ω Hz 0 1000 200 400 600 800 damping factor 8 MEASUREMENTS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .31 Figure 8.6 THD+N vs. input voltage @ 1 kH ...

  • Camco 32 dB - page 33

    Vrm s dB -100 -20 -90 -80 -70 -60 -50 -40 -30 100u 6 200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2 T Vrm s dB -120 -20 -110 -100 -90 -80 -70 -60 -50 -40 -30 100u 6 200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2 8 MEASUREMENTS USER MANUAL VORTEX 6, 4, 2.6 and 200V P .32 Figure 8.9 CCIF diff erence frequency method (10,5 kHz and 11,5 kHz) v ...

  • Camco 32 dB - page 34

    Wat ts Impedance / Ω 2 4 8 0 1000 2000 Distor tion limited output power (0,1 % THD) Pea k p ow er 1305 1760 988 755 450 528 0 1000 2000 3000 4000 5000 Distor tion limited output power (0,1 % THD) Pea k p ow er 4 8 16 2956 3961 2186 1823 1029 11 2 8 Wat ts Impedance / Ω 2 4 8 0 1000 2000 3000 4000 5000 Distor tion limited output power (0,1 % THD ...

  • Camco 32 dB - page 35

    9 W ARRANT Y INFORMA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .34 9.1 Summary O f W arranty CAMC O guarantees the VORTEX amplifi er to be free from defective material and/or workmanship for a period of six (6) years from the date of sale . When a defect occurs under normal installation and use, CAMC O will repair the product under this warrant ...

  • Camco 32 dB - page 36

    10 SERVICE INFORMA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .35 Owner ’ s Information Company Name: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Contact: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Address: __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ _ ...

  • Camco 32 dB - page 37

    1 1 MAINTENANCE INFORMA TION/1 2 DEC OMISSIONING USER MANUAL VORTEX 6, 4, 2.6 and 200V P .36 11 Maintenance Information Cleaning and servicing the inside of the amplifi er must never carry out by un- qualifi ed personnel. The amplifi er must never be opened by unqualifi ed person- nel. Cleaning and servicing work on the inside of the amplifi e ...

  • Camco 32 dB - page 38

    C OMP ANY INFORMA TION USER MANUAL VORTEX 6, 4, 2.6 and 200V P .37 Mailing Address: CAMCO P roduktions- und V er triebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 D-57482 Wenden Germany T elephone: +49 (0) 2762 408-0 F acsimile: +49 (0) 2762 408-10 Internet: www .camcoaudio.com Email: postmaster@camcoaudio .com ...

  • Camco 32 dB - page 39

    NO TICES USER MANUAL VORTEX 6, 4, 2.6 and 200V P .38 ...

  • Camco 32 dB - page 40

    www .c amcoaudio .com ...

Manufacturer Camco Category Stereo Amplifier

Documents that we receive from a manufacturer of a Camco 32 dB can be divided into several groups. They are, among others:
- Camco technical drawings
- 32 dB manuals
- Camco product data sheets
- information booklets
- or energy labels Camco 32 dB
All of them are important, but the most important information from the point of view of use of the device are in the user manual Camco 32 dB.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Camco 32 dB, service manual, brief instructions and user manuals Camco 32 dB. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Camco 32 dB.

Similar manuals

A complete manual for the device Camco 32 dB, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Camco 32 dB by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Camco 32 dB.

A complete Camco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Camco 32 dB - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Camco 32 dB, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Camco 32 dB, that we can find in the current document
3. Tips how to use the basic functions of the device Camco 32 dB - which should help us in our first steps of using Camco 32 dB
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Camco 32 dB
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Camco 32 dB in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Camco 32 dB?

Use the form below

If you did not solve your problem by using a manual Camco 32 dB, ask a question using the form below. If a user had a similar problem with Camco 32 dB it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)