  • UltraViolet Devices MP16A - page 1

    375 Marcus Boulevard • Hauppauge, NY 1 1 788 • USA 63 1 .273.0500 • Fax: 63 1 .273.077 1 e-mail: info@ultraviolet.com Extensive Product Information A vailable at: Document No. 98 - 1 123E1 • Revised February 2007 • © 1994-2007 Atlantic Ultraviolet Corporation www .ultraviolet.com ...

  • UltraViolet Devices MP16A - page 2

    2 T ABLE OF CONTENTS S AFETY W ARNINGS .....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................ ...

  • UltraViolet Devices MP16A - page 3

    3 SAFETY W ARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property . This ...

  • UltraViolet Devices MP16A - page 4

    4 PRODUCT APPLICA TION C ONSTRUCTION • The water purifier is designed to mount horizontally . • A drain port on the chamber aids in draining of the purifier . • The water purifier chamber is passivated and electropolished type 316 Stainless S teel. • The ballast housing is a combination of Stainless S teel T ype 304 and Aluminum Alloy . • ...

  • UltraViolet Devices MP16A - page 5

    5 INST ALLA TION L OCA TION 1. The water purifier is intended for indoor use only . The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier , should be between 33  F and 100  F. 2. Electrical power supplied to the water purifier MUST mat ...

  • UltraViolet Devices MP16A - page 6

    6 6 3. The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting holes in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing connections. 4. The water purifier must be connected to the cold water line only . 5. It is reco ...

  • UltraViolet Devices MP16A - page 7

    7 R ECOMMENDED O PTIONS 1 . Guardian ™ Ultraviolet Monitor: V isually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier . The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultra ...

  • UltraViolet Devices MP16A - page 8

    8 MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “ W ater Quality ” in the “ Pr oduct Application ” section. Ordinary mainte- nance consists of; • Lamp replacement is recommended every 10,000 hours of operation, appro ...

  • UltraViolet Devices MP16A - page 9

    9 S tep 2 - Remove End-Cap S tep 3 - W ithdraw Lamp S tep 4 & 5 - Remove Sockets S tep 6 - Remove Lamp L AMP I NST ALLA TION OR R EPLACEMENT Figure 3 - Lamp Replacement 1. Disconnect power to water purifier . 2. Remove both easy-off end caps by pulling each cap of f static gland nut. Slide each end cap along the wire away from the socket. 3. Ca ...

  • UltraViolet Devices MP16A - page 10

    10 1. Disconnect power to water purifier . 2. Shut off water supply to water purifier via inlet and outlet shut of f valves. Drain chamber by removing drain plug. Once the chamber is completely drained, remove any old sealing tape from the threads of the drain plug, rewrap with 1/2" wide T eflon ® thread sealing tape, reinstall and tighten th ...

  • UltraViolet Devices MP16A - page 11

    11 R EPLACEMENT OF B ROKEN Q UARTZ S LEEVE CAUTION: Broken Quartz is SHARP . It is r ecommended that protective goggles and gloves are worn when handling br oken quartz sleeves. 1. Disconnect power to water purifier . 2. Shut off water supply to the water purifier via the inlet and outlet shut of f valves. Drain the chamber by removing the drain pl ...

  • UltraViolet Devices MP16A - page 12

    12 O PTIONAL G UARDIAN ™ ™ U L TRA VIOLET M ONIT OR S ENSOR P ROBE C LEANING Figure 5 - Ultraviolet Monitor and Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity , as shown on the intensity meter , it may be necessary to clean the Ultraviolet Monitor's sensor probe. The senso ...

  • UltraViolet Devices MP16A - page 13

    13 Problem Possible Cause Corrective Action No electrical power… V erify that the purifier is connected to a live power source. Ballast Disconnect the purifier from utility power . Replace lamp. Lamp-out Protection The purifier must remain disconnected from power for (MP16A, MP22A & MP36C) two (2) minutes to reset. Cracked or broken Shut down ...

  • UltraViolet Devices MP16A - page 14

    14 TECHNICAL SPECIFICA TIONS T able 4 - T echnical Specifications Model: MP13A MP16A MP22A MP36C MP49C Flow Rate (GPM): 2 3 6 12 20 InletOutlet Size: 1 / 2 " m NPT 3 / 4 " m NPT 3 / 4 " m NPT 1 " m NPT 1- 1 / 2 " m NPT Number of Lamps: 1 1 1 1 1 Lamp Model No.: GPH212T5L GPH287T5L GPH436T5L G36T6L G48T6L Length: 13- 1 / 2 ...

  • UltraViolet Devices MP16A - page 15

    15 OPTIONAL ACCESSORIES Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. Please specify . Consult Factory for 12v DC or other special input power requirements. T able 5 - Optional Accessories Optional Accessories Available for: Guardian ™ Ultraviolet Monitor - Analog / Digital MP13A through MP49C Sentr ...

  • UltraViolet Devices MP16A - page 16

    16 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP13A, MP16A & MP22A Figure 6 - Exploded V iew MP13A, MP16A & MP22A ...

  • UltraViolet Devices MP16A - page 17

    17 ITEM MP13A MP16A MP22A NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1 108B 2 00-1108B 2 00-1108B 3 Lamp Spacer 2 25-0208A 2 25-0208A 2 25-0208A 4 Lead W ire & Socket 2 05-1219B2 2 05-1219B2 2 05-1219B3 5 Lamp 1 05-1400 1 05-1098 1 05-109 ...

  • UltraViolet Devices MP16A - page 18

    18 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP36C & MP49C Figure 7 - Exploded V iew MP36C & MP49C ...

  • UltraViolet Devices MP16A - page 19

    19 ITEM MP36C MP49C NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1108B 2 00-1 108B 3 Lamp Spacer - - 2 25-0209A 4 Lead W ire & Socket 2 05-1218A2 2 05-1218A2 5 Lamp 1 05-1343 1 05-1334 6 Static Gland Nut 2 25-1492D 2 25-1492D 7 T eflon ® ...

  • UltraViolet Devices MP16A - page 20

    20 W ARRANTY W e warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product’ s total rated life, whichever first occurs. W ithin the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and wh ...

Manufacturer UltraViolet Devices Category Water System

Documents that we receive from a manufacturer of a UltraViolet Devices MP16A can be divided into several groups. They are, among others:
- UltraViolet Devices technical drawings
- MP16A manuals
- UltraViolet Devices product data sheets
- information booklets
- or energy labels UltraViolet Devices MP16A
All of them are important, but the most important information from the point of view of use of the device are in the user manual UltraViolet Devices MP16A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals UltraViolet Devices MP16A, service manual, brief instructions and user manuals UltraViolet Devices MP16A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product UltraViolet Devices MP16A.

A complete manual for the device UltraViolet Devices MP16A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use UltraViolet Devices MP16A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of UltraViolet Devices MP16A.

A complete UltraViolet Devices manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual UltraViolet Devices MP16A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the UltraViolet Devices MP16A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the UltraViolet Devices MP16A, that we can find in the current document
3. Tips how to use the basic functions of the device UltraViolet Devices MP16A - which should help us in our first steps of using UltraViolet Devices MP16A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with UltraViolet Devices MP16A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of UltraViolet Devices MP16A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning UltraViolet Devices MP16A?

Use the form below

If you did not solve your problem by using a manual UltraViolet Devices MP16A, ask a question using the form below. If a user had a similar problem with UltraViolet Devices MP16A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)