Manual Metrologic Instruments IS1650

52 pages 5.73 mb
Download

Go to site of 52

Summary
  • Metrologic Instruments IS1650 - page 1

    METROLOGIC INSTRUMENTS, INC. IS1650 Focus E ™ Area Imaging Bar Code Scanner Installation and User’s Guide ...

  • Metrologic Instruments IS1650 - page 2

    Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark ...

  • Metrologic Instruments IS1650 - page 3

    ii T ABLE OF C ONTENTS I NTRODUCTION Product Over view ............................................................................................. 1 Key Product F eatures ....................................................................................... 1 Applications an d Protoc ols .......................................................... ...

  • Metrologic Instruments IS1650 - page 4

    iii T ABLE OF C ONTENTS Visual Indi cators ............................................................................................. 23 Failure Modes ................................................................................................. 24 Depth of Field by Minimum Bar Code Elem ent Width .................................... 25 IR Ac ...

  • Metrologic Instruments IS1650 - page 5

    1 I NTRODUCTION P RODUCT O VERVIEW The IS1650 is a high performance ar ea imag ing bar code scann er that utilizes a high-resolution CMOS imaging sensor for un rivaled image quality. T he IS1650 is the choice of 2D imaging scanners that deliv ers superior performance for presentation and fixed-mount applications. T he IS1650 employs Omniplanar, Inc ...

  • Metrologic Instruments IS1650 - page 6

    2 I NTRODUCTION A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 14 RS232 (TX, RX, RTS, CTS, DTR) 38 Low Speed USB and RS232 Transmit/Receive 47 Keyboard Wedge, Stand-Alon e Keyboard and RS232 Transmi ...

  • Metrologic Instruments IS1650 - page 7

    3 I NTRODUCTION S CANNER AND A CCESSORIES B ASI C K IT Part # Description IS1650 Area Imaging Bar Code Scanner 00-02544 MetroSelect ® Singl e-Line Configur ation Guide* 00-02281 Area Imaging Supplement al Confi guration Guide* 00-02287 IS1650 Series Area Imaging Bar Cod e Scanner Installation and User’s Guide* * Also available for download on th ...

  • Metrologic Instruments IS1650 - page 8

    4 I NTRODUCTION S CANNER AND A CCESSORIES O PTIONAL A CCESSORIES Part # Description IS1650 Scanner Interface Sp ecific Cables 59-59000-3 RS232 PowerLink Cable with Built in Power Jack, straight, black 54-54002-3 Keyboard Wedge PowerLink Cabl e with Adapter Cable, straight, black 54-54020-3 Stand Alone Keyboard PowerLink C able, straight, black 59-5 ...

  • Metrologic Instruments IS1650 - page 9

    5 I NTRODUCTION S CANNER AND A CCESSORIES O PTIONAL A CCESSORIES Part # Description 00-02001 IS1650 Series Stand Installation Guide 46-00710 Flex Stand, Kit Flex Stand, Kit Components a. Stand Ba se ............................................................................... Qty. 1 b. Flexible Shaft .............................................. ...

  • Metrologic Instruments IS1650 - page 10

    6 I NTRODUCTION D ESIGN S PECIFICATIONS IS1650 D ESIGN S PECIFICATIONS O PER AT IO N AL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output of an Osram LED: Maximum 85 mA emits 3,120 mlm Depth of Scan Field: 0 mm – 254 mm (0 " – 10 " ) for 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9 " W x ...

  • Metrologic Instruments IS1650 - page 11

    7 I NTRODUCTION D ESIGN S PECIFICATIONS (C ONT .) IS1650 D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Operation = 330 mA (Typical) Current: Idle / Standby = 160 mA (Typical) DC Transformer: Class 2; 5.2VDC @ 1 AMP ...

  • Metrologic Instruments IS1650 - page 12

    8 B ASE M ODEL C HARACTERISTICS IS1650 S CANNER Components Figure 1. Scanner Components Item Description 1 Red W indow LED Aperture 2 Blue LED See Visual Indicators (on page 23) 3 White LED See Visual Indicators (on page 23) 4 Yellow LED See Visual Indicators (on page 23) 5 Trigger Initiates Bar Code Read 6 Speaker See Audible Indica tors (on page ...

  • Metrologic Instruments IS1650 - page 13

    9 B ASE M ODEL C HARACTERISTICS IS1650 S CANNER Dimensions Figure 2. Scanner Dimensions Figure 3. M3 Mounting Hole Dimensions Caution: The depth of each mounting hole is 12 mm (0.5 " ). For fixed mount, the mounting screws should not be over-tightened or go deeper than 10 mm ( 0.4 " ) passing the bottom surface of the unit. Going further ...

  • Metrologic Instruments IS1650 - page 14

    10 B ASE M ODEL C HARACTERISTICS IS1650 S CANNER Caution and Serial Number Labels Each scanner has a label loc ated on the bottom of the unit, as well as text embedded into the bottom casing. This l abel provides the u nit’s model number, date of manufacture, serial number, CE and caution information. T he following figure gives an example of the ...

  • Metrologic Instruments IS1650 - page 15

    11 I NSTALLATION T HE P OWER L INK C ABLE Connecting Important: If the PowerLink cable is not fully ‘latched’, the unit can power intermittently. Figure 5. Figure 6. Disconnecting Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disco nnected from the PowerL ...

  • Metrologic Instruments IS1650 - page 16

    12 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) RS232 IS1650-14 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. 3. Connect the 9-pin D-type connector of the communication cable to the proper COM ...

  • Metrologic Instruments IS1650 - page 17

    13 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) Keyboard Wedge IS1650-47 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the IS1650. There will be an audibl e click when the connector lock engages. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” ends ...

  • Metrologic Instruments IS1650 - page 18

    14 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) Stand Alone Keyboard IS1650-47 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. 3. Plug the other end of the communication cable into the host’s k ...

  • Metrologic Instruments IS1650 - page 19

    15 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) IBM 46xx RS485 IS1650-1 06 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the h ...

  • Metrologic Instruments IS1650 - page 20

    16 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) Integrated USB: Low Speed IS1650-38 Full Speed IS1650-106 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the IS1650. There will be an audibl e click when the connector lock engag es. 3. Plug the USB type A end (locking with powe ...

  • Metrologic Instruments IS1650 - page 21

    17 I NSTALLATION F LEX S TAND I NSTALL ATIO N (O PTIONAL ) Metrologic provides two #8 wood scre ws for securing the stand base to the counter top. The following figure provides th e pilot hole dimensions for sec uring the stand base. Figure 13. Stand Base Hole Pattern (Not to Scale) ...

  • Metrologic Instruments IS1650 - page 22

    18 I NSTALLATION F LEX S TAND I NSTALL ATIO N (O PTIONAL ) Figure 14. Assembling the Stand ...

  • Metrologic Instruments IS1650 - page 23

    19 S CANNER C ONFIGURATION C ONFIGURATION M ODES The IS1650 Series scanner has three mod es of configuration. • Bar Codes The IS1650 can be configur ed by scanning the bar codes i ncluded in the Metrologic Single-Line Config uration Guide ( MLPN 00-0254 4) or the Supplemental Configuration Guide ( MLPN 00-02 281). These manuals can be downloaded ...

  • Metrologic Instruments IS1650 - page 24

    20 S CANNER C ONFIGURATION The IS1650 Focus E is part of Metrologic's lin e of scanners with flash upgradeable firm ware. The upgrade proces s requires a new firmware file supplied to the customer by a customer service representati ve  and Metrologic's MetroSet 2 software  . A personal computer running Windo ws 95 or greater with ...

  • Metrologic Instruments IS1650 - page 25

    21 S CANNER O PERATION M ODES OF O PERATION * Presentation Mode, Fixed-Moun t or In-Stand (Default) 1. The IR detects an object in the IR activation range an d the scanner’s light output automatically starts to flash as it attempts to scan the bar code. 2. The scanner continuously attempts to scan the bar code un til either it succeeds or the bar ...

  • Metrologic Instruments IS1650 - page 26

    22 S CANNER O PERATION A UDIBLE I NDICATORS When the IS1650 is in operati on, it pr ovides audible feedback. These sounds indicate the status of the scanner. Eight settings are availab le for the tone of the beep (normal, 6 alternate tones and no t one). T o change the tone, refer to the MetroSelect Single-Line Confi guration Guide ( MLPN 00-0254 4 ...

  • Metrologic Instruments IS1650 - page 27

    23 S CANNER O PERATION V ISUAL I NDICATORS The IS1650 has three LED indicators ( yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or constant activity of the LEDs indicates the status of the curr ent scan and the scanner. No LEDs are Illuminated The LEDs will not illuminat e if the scanner is not recei ...

  • Metrologic Instruments IS1650 - page 28

    24 S CANNER O PERATION F AILURE M ODES Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scan ner for repair. Short Razzberry Tone – During Scanning An invalid bar code has been scanned when in configuration. ...

  • Metrologic Instruments IS1650 - page 29

    25 S CANNER O PERATION D EPTH OF F IELD BY M INIMUM B AR C ODE E LEMENT W IDTH M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .191 .254 .330 .533 .254 .381 mils 5.2 7.5 10.4 13 21 10 15.9 Figure 17. Depth of Field by Minimum Bar Cod e Element Width Specifications are subjec t to change without notice. ...

  • Metrologic Instruments IS1650 - page 30

    26 S CANNER O PERATION IR A CTIVATION R ANGE The IS1650 has a built in obje ct detecti on sensor that instantly turns on the scanner when an object is presented with in the scanner’s IR activation Area. Figure 18. IR Activation Area Specifications are subjec t to change without notice . ...

  • Metrologic Instruments IS1650 - page 31

    27 M AINTENANCE D AILY M AINTENANCE Smudges and dirt on the unit's windo w c an interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non- abrasive cleaning cloth th en gently wipe the windo w clean. If the ...

  • Metrologic Instruments IS1650 - page 32

    28 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. All Interfaces IS1650 Series Troubleshooting Sy mptom / Solution Chart Symptoms Possible Causes Solution No power is being supplied to the scanner. Check tr ...

  • Metrologic Instruments IS1650 - page 33

    29 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep. The bar code symbology tryi ng to be scanned is not enabled. UPC/EAN, Code 39, interleave ...

  • Metrologic Instruments IS1650 - page 34

    30 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The bar code may have been printed incorrectly. Check if it is a check digit/character/or border problem. The scanner is not configured correctly for this type of bar code. Check if check digits are set properly. The unit beeps at some bar codes and NOT for others of the same bar code sym ...

  • Metrologic Instruments IS1650 - page 35

    31 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Alpha characters show as lower case. The computer is in Caps Lock mo ...

  • Metrologic Instruments IS1650 - page 36

    32 D EFAULT S ETTINGS Many functions of the scanner can be “confi g ured” – that is, enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then the defau ...

  • Metrologic Instruments IS1650 - page 37

    33 D EFAULT S ETTINGS PARAMETER DEFAULT RS232 IBM 46XX RS485 KBW & KEYBOARD USB Maxicode     Aztec     Postals     Mod 43 Check on Code 39     MSI-Plessy 10/10 Check Digit     MSI-Plessy Mod 10 Check Digit *     Paraf Support ITF     ITF Symbol Lengths Variable ...

  • Metrologic Instruments IS1650 - page 38

    34 D EFAULT S ETTINGS PARAMETER DEFAULT RS232 IBM 46XX RS485 KBW & KEYBOARD USB Transmit lead zero on UPC-E     Transmit UPC-A number system *     Transmit UPC-A Manufacturer ID# *     Transmit UPC-A Item ID# *     Transmit Codabar Start/Stop C haracters     CLSI Editing (Enabl e)  ...

  • Metrologic Instruments IS1650 - page 39

    35 D EFAULT S ETTINGS PARAMETER DEFAULT RS232 IBM 46XX RS485 KBW & KEYBOARD USB XON/XOFF Handshaking  ACK/NAK  Two Digit Supplements     Five Digit Supplements     Bookland     977 (2 digit) Supple mental Requirement     Supplements are not Required *     Two Digit Redundancy * ? ...

  • Metrologic Instruments IS1650 - page 40

    36 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS IS1650-14 RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The IS1650 scanner interface s terminate to a 10-pin, RJ45 Female Socket. The serial number label indicates the interface enabled wh ...

  • Metrologic Instruments IS1650 - page 41

    37 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS IS1650-38 Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D+ 7 V USB 8 USB D- 9 +5VDC 10 Shield Ground IS1650-106 IBM 46xx RS485 / Full Speed USB Pin Function 1 Ground 2 RS232 T ransmit Output 3 RS23 2 Receive Input 4 ...

  • Metrologic Instruments IS1650 - page 42

    38 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS (H OST E ND ) “Standard” PowerLink Cable 59-59000-3, Straight Pin Function 1 Shield Ground 2 RS232 T ransmit Output 3 RS232 Rece ive Input 4 DT R Input/Light Pen Source 5 Po wer/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 +5VDC Stand Alone PowerLink Keyboard Cable 54 ...

  • Metrologic Instruments IS1650 - page 43

    39 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS (H OST E ND ) Keyboard Wedge Cable 54-54002-3, Straight Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect Metrologic will supply an adap ter cable with a 5-pin DI ...

  • Metrologic Instruments IS1650 - page 44

    40 R EGULATORY C OM PLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or pe rformance of procedu res other than tho se specified he rein may result in h azardous radiation exposure. Under no cir cumstanc es should t he customer attempt ...

  • Metrologic Instruments IS1650 - page 45

    41 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the part y responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The follo wing is applicab le when the scanner c able is gre ater in le n ...

  • Metrologic Instruments IS1650 - page 46

    42 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the part y responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.8 feet) in length w hen full y extended: Les instructions ci-de ssous s’a ...

  • Metrologic Instruments IS1650 - page 47

    43 P ATENTS This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No.: 7,086,595; 7,128,266; 7,213,762; 7,216,81 0; 7,225,988; 7,225,989; 7,237,722; 7,240,844; 7,240,844; 7,243,847; 7,255,279; 7,267,282; 7,270,272; 7,273,180; 7,278,575; 7,281,661; 7,284,705; 7,293,714; 7,299,986; 7,3 2 ...

  • Metrologic Instruments IS1650 - page 48

    44 L IMITED W ARRANTY The IS1650 series scanners are manu factured by Metr olo gic at its Suzhou, C hina facility . The IS1650 series scanners hav e a two (2) y ear limited warranty fr om the date o f manufacture. Me trologic warrants and represents tha t all IS1650 serie s scanners are free o f all defects in ma terial, workman ship and design, an ...

  • Metrologic Instruments IS1650 - page 49

    45 I NDEX A AC ................................. 3, 7, 12–16 Accessori es ................................... 3 Adapter .................................... 3, 39 Apertu re......................................... 8 Audible Indica tor .............. 20, 23–24 B Bar Code ..................... 6, 19, 28–31 Bar Code Element ..................... ...

  • Metrologic Instruments IS1650 - page 50

    46 I NDEX M Maintenanc e ................................ 27 Meteor ......................................... 20 MetroSelect ....................... 2, 19, 22 MetroSet2 .............................. 20, 21 Mode of Oper ation ....................... 21 Mounting......................... See Stand N Notice s ........................................ 4 ...

  • Metrologic Instruments IS1650 - page 51

    47 ...

  • Metrologic Instruments IS1650 - page 52

    March 2008 Printed in the USA 00 - 02287 D ...

Manufacturer Metrologic Instruments Category Barcode Reader

Documents that we receive from a manufacturer of a Metrologic Instruments IS1650 can be divided into several groups. They are, among others:
- Metrologic Instruments technical drawings
- IS1650 manuals
- Metrologic Instruments product data sheets
- information booklets
- or energy labels Metrologic Instruments IS1650
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic Instruments IS1650.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic Instruments IS1650, service manual, brief instructions and user manuals Metrologic Instruments IS1650. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic Instruments IS1650.

A complete manual for the device Metrologic Instruments IS1650, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic Instruments IS1650 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic Instruments IS1650.

A complete Metrologic Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic Instruments IS1650 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic Instruments IS1650, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic Instruments IS1650, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic Instruments IS1650 - which should help us in our first steps of using Metrologic Instruments IS1650
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic Instruments IS1650
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic Instruments IS1650 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic Instruments IS1650?

Use the form below

If you did not solve your problem by using a manual Metrologic Instruments IS1650, ask a question using the form below. If a user had a similar problem with Metrologic Instruments IS1650 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)