Manual AquaStar 125B NG

16 pages 0.87 mb
Download

Go to site of 16

Summary
  • AquaStar 125B NG - page 1

    W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc ...

  • AquaStar 125B NG - page 2

    2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar . This same flow opens the gas valve, and the burners are ignited by th ...

  • AquaStar 125B NG - page 3

    3 ...

  • AquaStar 125B NG - page 4

    4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potable water , (b) toxic chemicals such as those commonly used for boiler treatment to prevent corrosion and freezing must not be introduced into the syste ...

  • AquaStar 125B NG - page 5

    5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any p ...

  • AquaStar 125B NG - page 6

    6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C. Back 0 inches D. Sides 4 inch (102mm) E. Bottom 12 inches (306 mm) Clearance from vent is ...

  • AquaStar 125B NG - page 7

    7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws. See figure 3 Fig. 3 - Flue Adaptor for High Altitude Installati ...

  • AquaStar 125B NG - page 8

    8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater an ...

  • AquaStar 125B NG - page 9

    9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate. If you don’t smell gas, ...

  • AquaStar 125B NG - page 10

    10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet ...

  • AquaStar 125B NG - page 11

    11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight. T o test the thermocouple, disconnect the thermocouple lead to the ECO. Insert a multi ...

  • AquaStar 125B NG - page 12

    12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure. However when the water valve opens, an ...

  • AquaStar 125B NG - page 13

    13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10. W ater valve 1 1. T emperature adjustment selector 12. Gas inlet gas pressure test nipple 3 ...

  • AquaStar 125B NG - page 14

    14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST ...

  • AquaStar 125B NG - page 15

    15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5 Draft divertor ¤ 8 705 505 354 6 Heat exchanger ¤ 8 705 406 235 7 Hot water pipe ¤ 8 700 705 556 8 Cold water pipe ¤ 8 700 705 294 9 Heat exchang ...

  • AquaStar 125B NG - page 16

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu ...

Manufacturer AquaStar Category Water Heater

Documents that we receive from a manufacturer of a AquaStar 125B NG can be divided into several groups. They are, among others:
- AquaStar technical drawings
- 125B NG manuals
- AquaStar product data sheets
- information booklets
- or energy labels AquaStar 125B NG
All of them are important, but the most important information from the point of view of use of the device are in the user manual AquaStar 125B NG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals AquaStar 125B NG, service manual, brief instructions and user manuals AquaStar 125B NG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product AquaStar 125B NG.

Similar manuals

A complete manual for the device AquaStar 125B NG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use AquaStar 125B NG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of AquaStar 125B NG.

A complete AquaStar manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual AquaStar 125B NG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the AquaStar 125B NG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the AquaStar 125B NG, that we can find in the current document
3. Tips how to use the basic functions of the device AquaStar 125B NG - which should help us in our first steps of using AquaStar 125B NG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with AquaStar 125B NG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of AquaStar 125B NG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning AquaStar 125B NG?

Use the form below

If you did not solve your problem by using a manual AquaStar 125B NG, ask a question using the form below. If a user had a similar problem with AquaStar 125B NG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)