  • MIPRO ACT-30T - page 1

    Specifications and design subject to change without notice. MN 014/03 All rights reserved. Do not copy or forward without prior approvals MIPRO. ACT-30T B odypack T ransmitters User Guide 2 C E 3 4 7 F ...

  • MIPRO ACT-30T - page 2

    1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. Do not install near any heat sources such as radiators, heat ...

  • MIPRO ACT-30T - page 3

    0 1 Bodypack Transmitter Bodypack Transmitter 1 Bodypack Controls and Indicators 3 O Display Screen ransmitter Parameters 12 Battery Status 13 15 AF attery R emoval and Installation perating Instructions 4 LCD 5 T MUTE Control Set-Up Input Connections 16 B Contents MUTE Button: T o mute and un-mute the audio signal tempor ary . Audio Input Connecto ...

  • MIPRO ACT-30T - page 4

    Antenna: Flexible 1/4 wave transmitting antenna. Transmitter Housing: Holds PCB board and wires. LCD Panel: Display tr ansmitter parameters. SET Button: Parameter selection button. MODE Button: Allows access to 7 av ailable functions displaying in LCD panel. Power Button: Press and hold 2 seconds to power ON or OFF . ACT IR Port: Align and syncs th ...

  • MIPRO ACT-30T - page 5

    Group and Channel Frequency Sensitivity Level RF Output Power Frequency Band MUTE Mode Par ameters Lock & Unlock Status B A C D E F G Transmitter Parameters MODE SET 07 03 CH GRP 4 5 Bodypack Transmitter Bodypack Transmitter G E A D B C UNLOCK SET LOCK 802.000 MHz FREQUENCY MIC-L AF GAIN 8A BAND MANUAL MUTE MODE RF-LOW RF POWER MODE MODE MODE M ...

  • MIPRO ACT-30T - page 6

    ! Frequency Band, Group & Channel and Frequency are factory pre-set, thus, its parameter values are displayed after it is ACT synced. V alues cannot be changed. ( ) Frequency Band ( ) Group and Channel ( ) Frequency Setting Input Sensitivity Level ! 4 Selectable Sensitivity Levels: LINE 、 MIC-L (MICROPHONE-LOW) 、 MIC-M (MICROPHONE-MID) 、 ...

  • MIPRO ACT-30T - page 7

    Setting RF Output Power ! 2 RF Output P ower Levels: RF-LOW and RF-HI . ! Press MODE button until RF POWER LOW or RF POWER HIGH mode appears. ! Press SET button once to activate function. ! Press SET button to select the desired RF output power . ! Press MODE button to confirm and sav e the change. MUTE MODE ! MUTE MODE: Select from MANUAL and DISA ...

  • MIPRO ACT-30T - page 8

    Setting LOCK 1 0 11 Bodypack Transmitter Bodypack Transmitter LOCK SET LOCK UNLOCK SET LOCK SET LOCKED RF POWER RF-HI RF POWER SET MODE ! Setting LOCK can be switched to LOCK or UNLOCK mode. ! Press MODE button until SET LOCK mode appears. ! Press SET button to select the desired parameter . ! Press MODE button to confirm and sav e the change. ! Pr ...

  • MIPRO ACT-30T - page 9

    1 2 13 Bodypack Transmitter Bodypack Transmitter G E A D B C MUTE Control Set-Up MUTE control enables audio to be muted or un- muted tempor arily . Press MUTE button to mute audio tempor arily . Par ameter v alues can be changed and ACT sync activate during this MUTE mode. Press MUTE button to un-mute. ! ! MUTE AF MUTE AF INPUT UNLOCK SET LOCK AF M ...

  • MIPRO ACT-30T - page 10

    1 4 15 Bodypack Transmitter Bodypack Transmitter AUDIO SHIELD 4 3 2 1 PIN SHIELD AUDIO BIAS 3 4 PIN 1 2 AUDIO SHIELD 1 4 3 2 PIN SHIELD AUDIO 3 2 1 PIN 4 3 2 1 SHIELD AUDIO 1 3 4 2 PIN AF Input Connections (1) 2-Wire Electret condenser microphone Capsule (2) 3-Wire Electret condenser microphone Capsule (3) Dynamic Microphone (5) Line-in (Impedance ...

  • MIPRO ACT-30T - page 11

    Battery Removal and Installation Pushing down both snap locks on the sides to open battery compartment cover . T ake out the two batteries. (Figure 3) Insert two fresh AA batteries (alkaline type is recommended) into the battery compartment according to the correct polarity (- and +) as shown in (Figure 4). Then close the battery compartment cover ...

Manufacturer MIPRO Category AV extender

Documents that we receive from a manufacturer of a MIPRO ACT-30T can be divided into several groups. They are, among others:
- MIPRO technical drawings
- ACT-30T manuals
- MIPRO product data sheets
- information booklets
- or energy labels MIPRO ACT-30T
All of them are important, but the most important information from the point of view of use of the device are in the user manual MIPRO ACT-30T.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals MIPRO ACT-30T, service manual, brief instructions and user manuals MIPRO ACT-30T. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product MIPRO ACT-30T.

Similar manuals

A complete manual for the device MIPRO ACT-30T, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use MIPRO ACT-30T by users. Manuals are usually written by a technical writer, but in a language understandable to all users of MIPRO ACT-30T.

A complete MIPRO manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual MIPRO ACT-30T - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the MIPRO ACT-30T, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the MIPRO ACT-30T, that we can find in the current document
3. Tips how to use the basic functions of the device MIPRO ACT-30T - which should help us in our first steps of using MIPRO ACT-30T
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with MIPRO ACT-30T