Manual GE AJCS 06 LZ

32 pages 1.11 mb
Download

Go to site of 32

Summary
  • GE AJCS 06 LZ - page 1

    3 Important Safety Information 8 Installation Instructions Important Electrical Safety Window Installation Through-the-Wall Installation 4 Operating Instructions The Controls on Y our Air Conditioner Care of Product 24 Helpful Information Things That Are Normal 25 If Something Goes Wrong Before Y ou Call for Service GE Service Numbers Warranty GE A ...

  • GE AJCS 06 LZ - page 2

    Welcome to the GE family. We’re proud of our quality products and we believe in dependable service. You’ll see it in this easy-to-use manual and you’ll hear it in the friendly voices of our customer service department. Best of all, you’ll experience these values each time you enjoy the comfort of your air conditioner. That’s important, be ...

  • GE AJCS 06 LZ - page 3

    IMPORT ANT SAFETY INFORMA TION READ ALL SAFETY INFORMATION BEFORE USING • This air conditioner must be properly installed in accordance with the Installation Instructions before it is used. • Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. • Turn the mode control to OFF and unplug your ai ...

  • GE AJCS 06 LZ - page 4

    Your model will look like one of these. 4 The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to COOLER (blue) the indoor air will become cooler. Turn the knob to WARMER (red) and the indoor air will become warmer. HEA T PUMP MODELS Whe ...

  • GE AJCS 06 LZ - page 5

    5 Cooling/Heating Descriptions FOR NORMAL COOLING OR HEA TING Select HIGH COOL or HIGH HEA T with the thermostat at mid point. FOR MAXIMUM COOLING Select HIGH COOL with the thermostat at maximum cool. FOR MAXIMUM HEA TING Select HIGH HEA T with the thermostat at maximum heat. FOR QUIETER & NIGHTTIME COOLING Select LOW COOL or LOW HEA T with the ...

  • GE AJCS 06 LZ - page 6

    6 Operating Instructions Care & Cleaning Turn the air conditioner off and remove the plug from the wall out- let before cleaning. To clean, use water and a mild detergent. Do not use bleach or abrasives. Grille and Case The coils on the outdoor side of the air conditioner should be checked regularly. It is necessary to remove the chassis from t ...

  • GE AJCS 06 LZ - page 7

    T ur n the air conditioner off before cleaning. The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. Clogged filters reduce cool- ing, heating and airflow. Keeping the filter clean will: • Decrease cost of operation. • Save energy. • Prevent clogged heat exchanger coils. • Reduce ...

  • GE AJCS 06 LZ - page 8

    8 • For personal safety, this air conditioner must be properly grounded. • It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists. • Follow National Electrical Code (NEC) or local codes and ordinances. CAUTION: • Do not, under any circumstances, cut o ...

  • GE AJCS 06 LZ - page 9

    Before you begin AJES and AJHS models have filler panels. Directions begin below. The installation instructions for AJCS models with accordion curtains begin on page 17. IMPORT ANT : Be sure to remove the shipping pad inside the air conditioner next to the compressor. • Phillips-head screwdriver • Wood saw • Adjustable wrench • Ruler or tap ...

  • GE AJCS 06 LZ - page 10

    10 Installation Instructions Read completely, then follow step-by-step • These instructions are for a standard double- hung window. You will need to modify them for other types of windows. • The air conditioner can be installed without the filler panels if needed to fit in a narrow window. See the window opening dimensions to the right. • All ...

  • GE AJCS 06 LZ - page 11

    1 Remove the front grille. See the Care and Cleaning section. 2 Find the locking plate located on the front left side. 3 Remove the screw and the locking plate to unlock the air conditioner. 4 Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case. 5 Pull the bottom corners of ...

  • GE AJCS 06 LZ - page 12

    Installation Instructions 1 Assemble the sill supports. Do not fully tighten the spacer mounting screws at this time. 2 Before attaching the sill supports, place them on the window stool. Select the spacer position that will place the spacer near the outermost point on the sill. Tighten the spacer mounting screws. 3 Turn the bolts and tighten the l ...

  • GE AJCS 06 LZ - page 13

    Measur e, Cut and Install the Filler Panels NOTES: • On narrow sills, there may not be enough room to use the lock nut. • A deep offset sill may require a longer adjusting bolt than the standard hex head bolt provided. • On wood sills use the large washer between the bolt head and the sill. This prevents the bolt from digging into the wood. ...

  • GE AJCS 06 LZ - page 14

    Installation Instructions 1 Peel off the backing from the bottom window gasket. 2 Place the gasket on the stool and over the brackets, even with the rear edge, sticky side down. 3 Carefully slide the empty case into the window until the holes in the case line up with the holes in the panel angles. NOTES: • The case should have a 1/8 ² minimum ti ...

  • GE AJCS 06 LZ - page 15

    15 7 Place the vinyl window gasket over the case top gasket. Insert the panel tabs through the slits in the gasket. Cut the gasket on each side to the width of the window. 8 Close the window tightly on the vinyl gasket. Bend the gasket forward to expose the panel tabs. Drill pilot holes into the window sash. Panel tab Vinyl window gasket Attach the ...

  • GE AJCS 06 LZ - page 16

    16 Installation Instructions Replace the Air Conditioner in the Case 1 Carefully slide the air conditioner back into the case. 2 Attach the power cord to the base pan with the clamp. 3 When the wall outlet is to the left, extend the cord under the unit and hold it in place with the clamp. 4 Reinstall the locking plate with the tab behind the wall c ...

  • GE AJCS 06 LZ - page 17

    For models with accordion curtains Par ts Included Air conditioner T ype A (6) T ype B (15) Window locking bracket Foam top window gasket T op mounting rail Accordion curtain (left) Accordion curtain (right) Sill channel • Phillips-head screwdriver • Ruler or tape measure • Level • Scissors or knife • Pencil • Drill T ools Needed 17 ...

  • GE AJCS 06 LZ - page 18

    18 Installation Instructions Read carefully, then follow step-by-step • These instructions are for a standard double- hung window. You will need to modify them for other types of windows. • The air conditioner can be installed without the accordion curtains if needed to fit in a narrow window. See the window opening dimensions to the right. • ...

  • GE AJCS 06 LZ - page 19

    1 Remove the front grille. See the Care and Cleaning section. 2 Find the locking plate located on the front left side. 3 Remove the screw and the locking plate to unlock the air conditioner. 4 Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case. 5 Pull the bottom corners of ...

  • GE AJCS 06 LZ - page 20

    20 Installation Instructions Read carefully, then follow step-by-step 1 Install the top mounting rail with type B screws. 2 Attach the sill channel with type B screws. Align the holes on the bracket of the sill channel with the holes in the case. 3 Slide the right and left accordion curtains into the top mounting rail and sill channel. Secure with ...

  • GE AJCS 06 LZ - page 21

    21 Install the Window Gasket and the Locking Bracket 6 1 Cut the foam top window gasket to the window width. 2 ...

  • GE AJCS 06 LZ - page 22

    22 Installation Instructions 3 When the wall outlet is to the left, extend the cord under the unit and hold it in place with the clamp. 4 Reinstall the locking plate with the tab behind the wall case flange. Tighten the screw. 5 Reattach the front grille. An open ing for the power cord is on the bottom of the front grille. 6 Fill holes and cracks w ...

  • GE AJCS 06 LZ - page 23

    Through-the-Wall Installation Make certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle. The cord length for the 115-volt models is 72 ² to the right and 47 ² to the left. For the 230/208-volt models the cord length is 65 ² to the right and 39 ² to the left. The air conditioner wall case ...

  • GE AJCS 06 LZ - page 24

    24 Helpful Information Things That Are Normal You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. You may hear the thermostat click when the compressor cycles on and off. Water will collect in the b ...

  • GE AJCS 06 LZ - page 25

    25 Air Conditioner Doesn’ t Start Air Conditioner Does Not Cool or Heat as it Should The air conditioner • Make sure the air conditioner plug is is unplugged pushed completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker breaker is tripped box and replace fuse or reset the breaker. P ower failure • If po ...

  • GE AJCS 06 LZ - page 26

    26 Notes ...

  • GE AJCS 06 LZ - page 27

    Notes 27 ...

  • GE AJCS 06 LZ - page 28

    28 Notes ...

  • GE AJCS 06 LZ - page 29

    29 General Electric Company W arranty R egistration Department P .O. Box 34070 Louisville, KY 40232-4070 GE Ser vice Protection Plus ™ GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™ —comprehensive protection on all your appliances— No Matter What Brand! Benefits Include: • Backed by GE ...

  • GE AJCS 06 LZ - page 30

    Consumer Product Ownership R egistration Model Number Serial Number Important Mail T oday! GE Appliances General Electric Company Louisville, Kentucky 40225 First Name Mr. ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Year Zip Code Apt. # Last Name Phone Number _ _ Consumer Product Ownership R ...

  • GE AJCS 06 LZ - page 31

    800.626.2000 TDD 800-833-4322 GE Service Numbers We’ll be there! Open 24 hours a day, 7 days a week. GE Answer Center ® 800-GE-CARES (800-432-2737) We provide expert repair service, scheduled at a time that’s convenient for you. Our factory-trained technicians know your appliance inside and out— so most repairs can be handled in just one vis ...

  • GE AJCS 06 LZ - page 32

    Printed in China AJCS06 AJES08 AJES10 AJES06 AJHS08 AJCS08 AJCS10 What Is Not Covered FULL ONE-YEAR WARRANTY For one year from date of original pur- chase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the room air conditioner that fails because of a manu- facturing defect. FULL FIVE-YEAR WAR ...

Manufacturer GE Category Air Conditioner

Documents that we receive from a manufacturer of a GE AJCS 06 LZ can be divided into several groups. They are, among others:
- GE technical drawings
- AJCS 06 LZ manuals
- GE product data sheets
- information booklets
- or energy labels GE AJCS 06 LZ
All of them are important, but the most important information from the point of view of use of the device are in the user manual GE AJCS 06 LZ.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals GE AJCS 06 LZ, service manual, brief instructions and user manuals GE AJCS 06 LZ. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product GE AJCS 06 LZ.

Similar manuals

A complete manual for the device GE AJCS 06 LZ, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use GE AJCS 06 LZ by users. Manuals are usually written by a technical writer, but in a language understandable to all users of GE AJCS 06 LZ.

A complete GE manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual GE AJCS 06 LZ - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the GE AJCS 06 LZ, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the GE AJCS 06 LZ, that we can find in the current document
3. Tips how to use the basic functions of the device GE AJCS 06 LZ - which should help us in our first steps of using GE AJCS 06 LZ
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with GE AJCS 06 LZ
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of GE AJCS 06 LZ in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning GE AJCS 06 LZ?

Use the form below

If you did not solve your problem by using a manual GE AJCS 06 LZ, ask a question using the form below. If a user had a similar problem with GE AJCS 06 LZ it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)