    DS6300 QUICK REFERENCE GUIDE ...

  • Datalogic Scanning DS6300 - page 2

    CONTENTS DS6300-100-0 10 MASTER/SLA VE MODEL .............................................................................................. ............. 1 DS6300-100-0 11 PROFIBUS MODEL .................................................................................................. ................... 8 DS6300-100- 012 ETHERNE T MODEL .......... ...

  • Datalogic Scanning DS6300 - page 3

    DS6300 MASTER/SLAVE MODEL 1 DS6300-100-010 MA STER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C Main/Aux. I nter fac e 25-pin D- sub Male Connect or 1 Lonworks 9-pi n Male Connect or 2 Lonworks 9-pi n Female Connect or 3 ...

  • Datalogic Scanning DS6300 - page 4

    DS6300 MASTER/SLAVE MODEL 2 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32° to +104 °F) Codabar Code 128 Storage Temperatur e -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) Ambient Light EAN/UPC (includ ...

  • Datalogic Scanning DS6300 - page 5

    DS6300 MASTER/SLAVE MODEL 3 The details of the connector pins ar e indic ated in the following table: 25-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shield connected to ch assis 20 RXAU X Receive data of auxili ary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliar y RS232 (referred t ...

  • Datalogic Scanning DS6300 - page 6

    DS6300 MASTER/SLAVE MODEL 4 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to Externa l Trigger/PS input. DS4600A AUX C-BOX 100 Local Host PWR-120 DS630 ...

  • Datalogic Scanning DS6300 - page 7

    DS6300 MASTER/SLAVE MODEL 5 Multiplexer Layout E N T < < E N T < < 1 RS485 HD Main Interface * P.S. (Presence Sensor) connect ed to Externa l Trigger/PS input. RS232 Master/Slave Layout E N T < < E N T < < 1 Main Serial Interface 2 A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to Externa l Trigger/PS input. ...

  • Datalogic Scanning DS6300 - page 8

    DS6300 MASTER/SLAVE MODEL 6 Local Lonw orks Network Small Synchronized Netw ork with 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** Encoder connect ed to IN2/ENC input. Local Lonw orks Network Small Synchronized Netw ork with more than 2 Readers and Si ngle Power Unit ...

  • Datalogic Scanning DS6300 - page 9

    DS6300 MASTER/SLAVE MODEL 7 Large Synchronize d Network * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to ENC input. Large Synchronized Network w ith DX6X00 and DS6XXX Scanners * ** ...

  • Datalogic Scanning DS6300 - page 10

    DS6300 PROFIBUS MODEL 8 DS6300-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C Prof ibus 9- pin Fema le Connect or (whi te) 1 Lonworks 9-pi n Female Connect or 2 Ma in/Aux. Interface 26-p in D-Su b Ma le Connec to ...

  • Datalogic Scanning DS6300 - page 11

    DS6300 PROFIBUS MODEL 9 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperatur e -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) Ambient Light EAN/UPC (including Ad ...

  • Datalogic Scanning DS6300 - page 12

    DS6300 PROFIBUS MODEL 10 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shi eld connected to chassis 20 RXAU X Receive data o f auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliar y RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive p in 22 OUT 1- Con ...

  • Datalogic Scanning DS6300 - page 13

    DS6300 PROFIBUS MODEL 11 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Remote Host DS6300 C-BOX 100 PG6000 CAB-601X *P. ...

  • Datalogic Scanning DS6300 - page 14

    DS6300 PROFIBUS MODEL 12 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Remote Host Maste ...

  • Datalogic Scanning DS6300 - page 15

    DS6300 ETHERNET MODEL 13 DS6300-100-012 ET HERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Et herne t Int erf ace 1 Lonworks 9-pi n Female Connect or 2 Ma in/Aux. Interface 26-p in D-Su b Ma le ...

  • Datalogic Scanning DS6300 - page 16

    DS6300 ETHERNET MODEL 14 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperatur e -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) Ambient Light EAN/UPC (including A ...

  • Datalogic Scanning DS6300 - page 17

    DS6300 ETHERNET MODEL 15 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shield connected to ch assis 20 RXAU X Receiv e data of auxiliar y RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1- Conf ...

  • Datalogic Scanning DS6300 - page 18

    DS6300 ETHERNET MODEL 16 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Remote Host DS6300 C-BOX 100 PG6000 CAB-601X *P. ...

  • Datalogic Scanning DS6300 - page 19

    DS6300 ETHERNET MODEL 17 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Remote Host Maste ...

  • Datalogic Scanning DS6300 - page 20

    DS6300 DEVICENET MODEL 18 DS6300-100-015 D EVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On LE D (Red ) 4 LCD Display 5 Main/Aux. I nter fac e 26-pin D- sub Male Connect or 1 Lonworks 9-pi n Female Connect or 2 DeviceNet 5-pin Male Co nnector 3 Avail ...

  • Datalogic Scanning DS6300 - page 21

    DS6300 DEVICENET MODEL 19 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 sta ndard Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperatur e -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) Ambient Light EAN/UPC (including ...

  • Datalogic Scanning DS6300 - page 22

    DS6300 DEVICENET MODEL 20 The details of the connector pins ar e indic ated in the following table: 26-pin D-Sub Connector Pi nout Pin Name Function Chassis - internally connecte d to GND 1 CHASSIS Cable shield connected to chassis 20 RXAU X Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referr ed to GN ...

  • Datalogic Scanning DS6300 - page 23

    DS6300 DEVICENET MODEL 21 Connectivity: Point-to-Point Lay out * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Pass Through Layout E N T < < E N T < < 1 2 Main Serial Interface A uxiliary Serial Interface * P.S. (Presence Sensor) connect ed to External T rigger/PS input. Remote Host DS6300 C-BOX 100 PG6000 CAB-601X *P ...

  • Datalogic Scanning DS6300 - page 24

    DS6300 DEVICENET MODEL 22 Local Lonw orks Network Fieldbus Small Synchronized Netw ork * P.S. (Presence Sensor) connect ed to External T rigger/PS input. ** C-BOX 100 modified to accept scanner p ower. *** T he Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Remote Host Mast ...

  • Datalogic Scanning DS6300 - page 25

    DS6300 OSCILLATING MIRROR MODEL 23 DS6300-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 Oscillating mirror models are used when coverage of a la rge reading area is re quired, mainly in picket fence applications. The DS6300 scanner mou nts a dedicated optic head with integr ated oscill ating mirror driven by a linear motor. ...

  • Datalogic Scanning DS6300 - page 26

    DS6300 OSCILLATING MIRROR MODEL 24 The mirror can be deflected up to 40°. Oscillation with resp ect to the output window median axis is as ymmetrical (see figure below). 40° 3 7 . 5 ° 0° - 2 . 5 ° Oscillating Mirror Maximum Aperture and Asymme try By configuring the oscill ating speed up to the ma ximum value of 19 Hz, raster emu lation can be ...

  • Datalogic Scanning DS6300 - page 27

    COMMON FEATURES 25 COMMON FEATURES C-BOX 100 Pinout for DS6300: The table below gives the pi nout of the C-BOX 100 termi nal block connectors. Use this pinout when the DS6300 reader is connected in a net work by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 VS 2, 4, 6 GND 7, 8 EARTH GROUND 20, 40 Reserved Inputs 27 EXT T ...

  • Datalogic Scanning DS6300 - page 28

    COMMON FEATURES 26 Mechanical Installation: The DS6300 read er can be positi oned and installe d in the best way possible as a resul t of the Step-A-Head TM feature. Thanks to the separ ation bet ween Head and Bas e, you can modi f y the orientation of the d ecoder base, and therefore display-keypad and connecto r panels, while keeping th e optic h ...

  • Datalogic Scanning DS6300 - page 29

    COMMON FEATURES 27 Typical Installations: Standard Installation The DS6300 scann er is mounted on the ST -237 106° mounti ng bracket which guarantees a built-in Skew angle ( S in the figure belo w) of 16° with respect to the frame plane (t ypically the Ske w angle should be bet ween 10° - 20°). This avoids the direct reflection of the laser lig ...

  • Datalogic Scanning DS6300 - page 30

    COMMON FEATURES 28 Focus Adjustment: The DS6300 provides a man ual adjustme nt of the optics to optimize the reading performance by cho osing the best focus between two extreme positions. The focus adju stment is continuous and not by step; thus, allo wing an optimum adjustment around the selected pos ition. T he relative focus positions range from ...

  • Datalogic Scanning DS6300 - page 31

    COMMON FEATURES 29 7) Use the ▲ ( up arrow) and ▼ (do wn arrow) key to select the “E xit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to it s current operating mode. Focus Adjustment Screw NOTE The reader display shows the focus positio n only when the laser bea m is activated. It is possible ...

  • Datalogic Scanning DS6300 - page 32

    COMMON FEATURES 30 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 8 9 11 13 15 17 5 7 8 10 11 13 0.30 8 10 12 14 16 18 6 7 9 10 12 13 0.33 9 11 13 14 16 18 6 8 9 11 12 14 0.38 10 11 13 15 17 19 7 8 10 11 13 14 0.50 12 13 15 17 19 21 8 9 11 12 14 15 0.72 16 17 19 21 22 24 10 11 13 14 ...

  • Datalogic Scanning DS6300 - page 33

    COMMON FEATURES 31 Reading Diagrams: In the following reading diagr ams (0,0) is the center of the laser beam output windo w. DS6300-100-0 XX – Resolution: 0. 20 mm/8 mils CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 4 2 0 6 (in) 06 1 2 (i n) 81 0 1 4 1 6 0 1 52 02 5 3 03 54 ...

  • Datalogic Scanning DS6300 - page 34

    COMMON FEATURES 32 Reading Diagrams: DS6300-100-0 XX – Resolution: 0. 38 mm/15 mils CONDITIONS Code = Inte rleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 4 2 0 6 (in) 0 12 18 (in) 14 16 20 22 0 30 35 40 45 50 55 (cm) 25 20 15 10 0 (cm) 5 -5 -10 -15 -20 -25 8 10 -8 -10 -6 -4 -2 60 65 26 24 28 30 Focus ...

  • Datalogic Scanning DS6300 - page 35

    COMMON FEATURES 33 Reading Diagrams: DS6300-105-0XX (Osc illating Mirror) – Resolutio n: 0.20 mm/8 m ils CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 4 2 0 6 (in) 06 1 2 (in) 81 0 1 4 1 6 0 1 5 2 02 53 03 54 04 5 5 0 (cm) 25 20 15 10 0 (cm) 5 -5 -10 -15 -20 -25 8 10 -8 -10 -6 ...

  • Datalogic Scanning DS6300 - page 36

    COMMON FEATURES 34 Reading Diagrams: DS6300-105-0XX (Osc illating Mirror) – Resolutio n: 0.38 mm/15 mils CONDITIONS Code = Inte rleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 4 2 0 6 (in) 0 10 16 (in) 12 14 18 20 0 25 30 35 40 45 50 (cm) 25 20 15 10 0 (cm) 5 -5 -10 -15 -20 -25 8 10 -8 -10 -6 -4 -2 55 ...

  • Datalogic Scanning DS6300 - page 37

    COMMON FEATURES 35 User Interface: RS232 PC-side conn ections 1 5 9 6 9-pin male conne ctor 13 25 14 1 25-pin male c onnector Pin Name Pin Name 2 RX 3 RX 3 TX 2 T X 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wirin g diagram shows a simp le test cable including po wer, external (push-button) trigger ...

  • Datalogic Scanning DS6300 - page 38

    COMMON FEATURES 36 Figure C Laser Safety Label 1 The scanner is classified as a Class 2 laser product accord ing to EN 60825-1 regulati ons and as a Class II laser product according to CDRH regulations. Disconnect the po wer supply when openin g the device during ma intenance or installatio n to avoid exposure to hazardous laser light. There is a s ...

  • Datalogic Scanning DS6300 - page 39

    DECLARATION OF CONFORMITY 07 Datalogic A utomation S.r.l. Via S. Vitalino 13 40012 - Lippo di Cal derara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS6300-XXX-XXX , Laser Scanner; e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono ...

Manufacturer Datalogic Scanning Category Scanner

Documents that we receive from a manufacturer of a Datalogic Scanning DS6300 can be divided into several groups. They are, among others:
- Datalogic Scanning technical drawings
- DS6300 manuals
- Datalogic Scanning product data sheets
- information booklets
- or energy labels Datalogic Scanning DS6300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Datalogic Scanning DS6300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Datalogic Scanning DS6300, service manual, brief instructions and user manuals Datalogic Scanning DS6300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Datalogic Scanning DS6300.

A complete manual for the device Datalogic Scanning DS6300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Datalogic Scanning DS6300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Datalogic Scanning DS6300.

A complete Datalogic Scanning manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Datalogic Scanning DS6300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Datalogic Scanning DS6300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Datalogic Scanning DS6300, that we can find in the current document
3. Tips how to use the basic functions of the device Datalogic Scanning DS6300 - which should help us in our first steps of using Datalogic Scanning DS6300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Datalogic Scanning DS6300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Datalogic Scanning DS6300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Datalogic Scanning DS6300?

Use the form below

If you did not solve your problem by using a manual Datalogic Scanning DS6300, ask a question using the form below. If a user had a similar problem with Datalogic Scanning DS6300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)