Manual Burnham LE L7248

28 pages 0.82 mb
Download

Go to site of 28

Summary
  • Burnham LE L7248 - page 1

    81433010R18-1/08 As an ENERGY STAR ® Partner , U.S. Boiler Co., Inc. has determined that the LE1 red at the 0.60 GPH rate meets the ENERGY ST AR guidelines for Energy efciency established by the United States Environmental Protection Agency (EP A). Price - $3.00 D N A G N I T A R E P O , N O I T A L L A T S N I R O F S N O I T C U R T S N I ...

  • Burnham LE L7248 - page 2

    2 IMPOR T ANT INFORMA TION - PLEASE READ THIS P AGE CAREFULL Y 1. THIS BOILER HAS LIMITED W ARRANTIES, COPIES OF WHICH ARE PRINTED ON THE BACK COVER OF THIS MANUAL. 2. THIS BOILER IS SUIT ABLE FOR INST ALLA TION ON COMBUSTIBLE FLOORING. BOILER CAN NOT BE INST ALLED ON CARPETING. 3. ALL BOILERS MUST BE INST ALLED IN ACCORDANCE WITH NA TIONAL, ST A T ...

  • Burnham LE L7248 - page 3

    3 I. General Information I. General Infor mation .................................. 3 II. Installation I nstructions ............................ 5 III. Operating and Service Instructions .......... 12 T AbLE OF CONTENTS Figure 1: LE™ Packaged Boiler 1 . INSPECT SHIPMENT carefully for any signs of damage. A. ALL EQUIPMENT is carefully manufacture ...

  • Burnham LE L7248 - page 4

    4 3 . PROVIDE COMBUSTION AND VENTILA TION AIR. Local code provisions may apply and should be referenced. G N I N R A W r i a n o i t a l i t n e v d n a n o i t s u b m o c e t a u q e d A r e p o r p e r u s s a o t d e d i v o r p e b t s u m . n o i t s u b m o c A. Determine volume of space (boiler room). Rooms communicating directly with the s ...

  • Burnham LE L7248 - page 5

    5 II. Installation Instructions Figure 3: Hinge Installation & Assembly , LE Boiler 1. REMOVE CRA TE A. Remove all fasteners at crate skid. B. Lift outside container and remove all other inside protective spacers and bracing. Remove container containing Safety Relief V alve, Boiler Drain V alve and Pipe Fittings. 2. REMOV AL OF BOILER FROM SKID ...

  • Burnham LE L7248 - page 6

    6 Figure 4: Recommended W ater Piping for Zone V alve Zoned Heating Systems Figure 5: Recommended W ater Piping for Circulator Zoned Heating Systems ...

  • Burnham LE L7248 - page 7

    7 E. A hot water boiler installed above radiation level must be provided with a low water cutoff device as part of the installation. If a low water cut-off is required, it must be mount- ed in the system piping above the boiler . The minimum safe water level of a hot water boiler is just above the highest water containing cavity of the boiler; that ...

  • Burnham LE L7248 - page 8

    8 8. INST ALL SMOKEPIPE — The LE should be vented into a reclay tile-lined masonry chimney or a chimney constructed from T ype L V ent or a factory built chimney that complies with the T ype HT requirement, of UL103. The chimney and vent pipe shall have a sufcient draft at all times, to assure safe proper operation of the boiler . See Figur ...

  • Burnham LE L7248 - page 9

    9 : 2 E L B A T ) M P R 0 5 4 3 ( S T I N U E G A T S - E L G N I S S M E T S Y S E P I P - O W T " H " t f i L g n i b u T f o h t g n e L m u m i x a M " R " + " H " D O " 8 / 3 ) H P G 3 ( g n i b u T D O " 2 / 1 ) H P G 3 ( g n i b u T ' 0 ' 4 8 ' 0 0 1 ' 1 ' 8 7 ' 0 0 1 &apo ...

  • Burnham LE L7248 - page 10

    10 Figure 1 1B: Wiring Diagram for LE Boilers with Beckett AFG Burner , EC5000 Control, and Honeywell L4080B High Limit SEQUENCE OF OPERA TION Refer to EC5000 Manual for wiring and operation details. SEQUENCE OF OPERA TION A call for heat by the thermostat energizes the L7248C control which in turn energizes the R7184B primary control. The burner w ...

  • Burnham LE L7248 - page 11

    1 1 Figure 1 1C: Wiring Diagram for LE Boilers with Riello Burner ...

  • Burnham LE L7248 - page 12

    12 III. Operating and Service Instructions 1. AL W A YS INSPECT INST ALLA TION BEFORE ST AR TING BURNER. 2. FILL HEA TING SYSTEM WITH W A TER. NOTE: It is important to properly remove the oil and dirt from the system. CLEAN HEA TING SYSTEM If boiler water is dirty , refer to step 13 for proper cleaning instructions. A. Fill entire Heating System wi ...

  • Burnham LE L7248 - page 13

    13 Figure 12: L7248 Circuit Board Layout - Horizontal Mount E. DISPLA Y READOUT In the RUN mode, the Aquastat will ash "bt" (boiler temp) followed by the temperature (i.e., 220), followed by °F or °C. T o read boiler settings, press the I key to read the parameter of interest. For example, press I High Limit ( HL ) is displayed, foll ...

  • Burnham LE L7248 - page 14

    14 the burner output. The ZC output is ener gized. The controller continues to monitor the system and automatically restarts if the error condition clears. Refer to T able 4. The operating sequence for the L7248 is shown in T able 5. Figure 14: Setpoints and Differentials G. HIGH LIMIT CONTROLLER The High Limit opens and turns off the burner when t ...

  • Burnham LE L7248 - page 15

    15 T ABLE 6: BECKETT AFG BURNER C. Attach a plastic hose to fuel pump vent tting and provide a pan to catch the oil. D. REMOVE GAUGE POR T PLUG from fuel pump and install pressure gauge. E. REMOVE FLAME PLUG IN SWING DOOR. 8. ST AR T OIL BURNER A. Open vent tting on fuel pump. B. TURN ‘ON’ BURNER service switch and allow burner to run unt ...

  • Burnham LE L7248 - page 16

    16 Figure 16: Cad Cell Before pressing the reset button call your service- man immediately . N O I T U A C n e h w r e n r u b e h t t r a t s o t t p m e t t a t o n o D t i n u e h t n e h w , d e t a l u m u c c a s a h l i o s s e c x e n o i t s u b m o c e h t n e h w r o , r o p a v f o l l u f s i . t o h y r e v s i r e b m a h c 1 1 . CHE ...

  • Burnham LE L7248 - page 17

    17 B. Boiling Out of Boiler and System. The oil and grease which accumulate in a new hot water boiler can be washed out in the following manner . (1) Remove Safety Relief V alve using extreme care to avoid damaging it. (2) Partially ll boiler and add caustic soda or triso - dium phosphate. Add an appropriate amount of recommended boil out compou ...

  • Burnham LE L7248 - page 18

    18 Important Produc t Safety Informatio n Refractory Ceram ic Fiber Product Warning : The Repair Parts list designates parts that contain refracto ry ceramic fibers (RCF). RCF has been classified as a possible human carcinogen. When exposed to temperatures about 1805°F, su ch as during direct flame contact, RCF changes into crystalline silica, a k ...

  • Burnham LE L7248 - page 19

    19 H. COLD OIL — If the oil temperature approaching the fuel pump is 40°F or lower poor combustion or delayed ignition may result. Cold oil is harder to atomize at the nozzle. Thus, the spray droplets get larger and the ame shape gets longer . An outside fuel tank that is above grade or has fuel lines in a shallow bury is a good candidate for ...

  • Burnham LE L7248 - page 20

    20 IV . Boiler Cleaning G N I N R A W d e p p i u q e s r e l i o B . f f o d e n r u t h c t i w s e c i v r e s r e n r u b h t i w d e t e l p m o c e b t s u m g n i n a e l c r e l i o b l l A , e g a m a d y t r e p o r p e r e v e s e s u a c n a c h c i h w d r a z a h l a i t n e t o p a e v a h r o o d g n i w s r e n r u b h t i w o t h ...

  • Burnham LE L7248 - page 21

    21 V . Repair Parts All LE™ Series Repair Parts may be obtained through your local Burnham Wholesale distribu- tor . Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) ...

  • Burnham LE L7248 - page 22

    22 Figure 19: LE Boiler Jacket & Insulation ...

  • Burnham LE L7248 - page 23

    23 Figure 20: LE Bare Boiler Assembly ...

  • Burnham LE L7248 - page 24

    24 FIGURE 21: BECKETT AFG OIL BURNER REP AIR P ARTS For replacement oil burner parts, contact your wholesaler or the burner manufacturer: R.W . Beckett Co., P .O. Box 1289, Elyria, OH 44036 (440) 327-1060 (800) OIL BURN(645-2876) F AX (440) 327-1064 ...

  • Burnham LE L7248 - page 25

    25 L E D O M 1 E L 2 E L ) h p g ( e t a R g n i r i F 0 6 . 0 0 0 . 1 5 2 . 1 t t e k c e B . o N c e p S 1 1 6 4 B C B 2 1 6 4 B C B n o i t a n i b m o C e b u T r i A B M 0 5 G F A D M 0 5 G F A e p y T d a e H n o i t s u b m o C 1 L 1 V d n a B r i A A K B 2 9 4 3 r e t t u h S r i A K B 9 0 7 3 r e w o l B 9 9 9 2 t i K e l f f a B e t a R g ...

  • Burnham LE L7248 - page 26

    26 SER VICE RECORD DA TE SERVICE PERFORMED ...

  • Burnham LE L7248 - page 27

    27 VI. Low W ater Cut Off (L WCO) A 24 V AC L WCO is used primarily for gas red boilers where a 24 volt control circuit exists within the boiler . However , a 24 V AC L WCO can only be used if the boiler manufacturer has provided piping and wiring connections and instructions to allow for this application. How to T est Shut off fuel supply . Low ...

  • Burnham LE L7248 - page 28

    28 if the residential grade water boiler is used or operated over its rated capacity, is subjected to unauthorized modification, or is damaged as a result of being otherwise improperly operated or serviced including, but not limited to, damage from any of the following: operation with insufficient water, allowing the boiler to freeze, subjecting th ...

Manufacturer Burnham Category Boiler

Documents that we receive from a manufacturer of a Burnham LE L7248 can be divided into several groups. They are, among others:
- Burnham technical drawings
- LE L7248 manuals
- Burnham product data sheets
- information booklets
- or energy labels Burnham LE L7248
All of them are important, but the most important information from the point of view of use of the device are in the user manual Burnham LE L7248.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Burnham LE L7248, service manual, brief instructions and user manuals Burnham LE L7248. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Burnham LE L7248.

Similar manuals

A complete manual for the device Burnham LE L7248, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Burnham LE L7248 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Burnham LE L7248.

A complete Burnham manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Burnham LE L7248 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Burnham LE L7248, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Burnham LE L7248, that we can find in the current document
3. Tips how to use the basic functions of the device Burnham LE L7248 - which should help us in our first steps of using Burnham LE L7248
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Burnham LE L7248
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Burnham LE L7248 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Burnham LE L7248?

Use the form below

If you did not solve your problem by using a manual Burnham LE L7248, ask a question using the form below. If a user had a similar problem with Burnham LE L7248 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)